VISHAY DCMKP880-200

DCMKP
Vishay ESTA
Capacitors for Power Electronics (PEC) - Cylindrical
FEATURES
•
•
•
•
•
•
High impulse current rating up to 10 kA
Low self-inductance of < 100 nH
High reliability and life expectancy
Withstands heavy duty shock and vibration
Non-polar dielectric
Dry, resin filled
APPLICATIONS
• DC linking and DC filtering in industry and traction
converters
• DC linking in low-power drives
• Impulse discharge capacitors for magnetizing and
welding
• Replacement of aluminum electrolytic capacitors (lower
capacitance, higher currents)
QUICK REFERENCE DATA
DESCRIPTION
Rated DC voltage min.
Rated DC voltage max.
Capacitance min.
Capacitance max.
Technology
Dissipation factor (tan 0)
Capacitance tolerance
VALUE
880 V
1000 V
30 μF
2235 μF
Metallized polypropylene
< 2 x 10-4
±5%
min. - 40 °C
max. + 80 °C
< 100 nH
200 000 h at UNDC and < 60 °C hotspot
200 FIT
Terminal/terminal = 1.5 x UNDC, 10 s
Terminal/case = 2 x UNDC + 1000 VAC, 60 s
Aluminum
Resin polyurethane, UL 94 V-0
IEC 61071-1, IEC 61881 and EN 61071-1
Operating temperature (hot spot)
Inductance
Lifetime expectancy
Reliability
Test voltage
Casing material
Filling
Standards
DIMENSIONS in millimeters
A
M8
A = 32 mm
A = 50 mm
H
D ≤ 84.4 mm
D = 116 mm
9.5 ± 0.5
30 ± 1
D
0
15.8 - 1
M12
Drawing 1
www.vishay.com
14
For technical questions, contact: [email protected]
Document Number: 13039
Revision: 15-Feb-11
DCMKP
Capacitors for Power Electronics
(PEC) - Cylindrical
Vishay ESTA
TYPE DESCRIPTION
TYPE
CN
RS
VOLTAGE
Rth
DCMKP
[μF]
V
[m]
[K/W]
DC
...-...IBR
DCMKP 880, UNDC = 880 V, VAC = 220 VRMS
880-200
200
880
3.4
15.0
880-270
270
880
4.4
11.7
880-370
370
880
2.2
12.8
880-510
510
880
2.8
9.8
DCMKP 1.1, UNDC = 1100 V, VAC = 275 VRMS
1.1-130
130
1100
3.9
14.9
1.1-175
175
1100
5.2
11.6
1.1-240
240
1100
2.5
12.7
1.1-280
280
1100
7.7
7.7
1.1-330
330
1100
3.2
9.8
1.1-525
525
1100
4.5
6.5
1.1-1000
1000
1100
2.9
5.4
DCMKP 1.3, UNDC = 1300 V, VAC = 325 VRMS
1.3-90
90
1300
4.6
15.0
1.3-120
120
1300
6.0
11.7
1.3-165
165
1300
2.9
12.8
1.3-195
195
1300
9.0
7.7
1.3-230
230
1300
3.6
9.8
1.3-365
365
1300
5.1
6.5
1.3-710
710
1300
3.2
5.4
DCMKP 1.55, UNDC = 1550 V, VAC = 385 VRMS
1.55-65
65
1550
5.2
15.1
1.55-90
90
1550
6.8
11.6
1.55-120
120
1550
3.2
12.9
1.55-145
145
1550
10.3
7.7
1.55-165
165
1550
4.1
9.9
1.55-265
265
1550
5.9
6.6
1.55-520
520
1550
3.6
5.4
DCMKP 1.75, UNDC = 1750 V, VAC = 440 VRMS
1.75-50
50
1750
5.7
15.0
1.75-65
65
1750
7.6
11.6
1.75-90
90
1750
3.5
12.9
1.75-110
110
1750
11.5
7.7
1.75-125
125
1750
4.5
9.9
1.75-200
200
1750
6.6
6.6
1.75-390
390
1750
3.9
5.5
DCMKP 2.0, UNDC = 2000 V, VAC = 500 VRMS
2.0-35
35
2000
6.4
15.2
2.0-50
50
2000
8.4
11.6
2.0-70
70
2000
3.8
12.8
2.0-85
85
2000
12.9
7.8
2.0-110
110
2000
5.0
9.9
2.0-160
160
2000
7.2
6.6
2.0-310
310
2000
4.3
5.5
DCMKP 2.2, UNDC= 2200 V, VAC = 550 VRMS
2.2-30
30
2200
7.0
15.1
2.2-40
40
2200
9.2
11.6
2.2-55
55
2200
4.1
12.9
2.2-70
70
2200
14.2
7.8
2.2-80
80
2200
5.4
9.9
2.2-130
130
2200
8.0
6.6
2.2-250
250
2200
4.7
5.5
IMAX.
[A]
IP
[kA]
Î
[kA]
HEIGHT
[mm]
D
[mm]
34.0
35.0
46.0
48.0
0.75
0.73
1.38
1.39
2.25
2.21
4.15
4.18
105
130
105
130
64
64
84
84
0.4
0.4
0.6
0.7
9
9
4
4
1
1
1
1
32.0
32.0
43.0
31.0
44.0
46.0
62.0
0.60
0.60
1.12
0.60
1.12
1.68
2.14
1.82
1.80
3.37
1.80
3.37
5.05
6.42
105
130
105
185
130
185
185
64
64
84
64
84
84
116
0.3
0.4
0.6
0.5
0.7
1.3
1.9
9
9
4
9
4
4
4
1
1
1
1
1
1
1
29.0
29.0
40.0
30.0
41.0
42.0
59.0
0.50
0.94
1.91
0.50
0.93
2.05
3.83
1.50
2.82
5.75
1.50
2.80
6.16
11.5
105
130
105
185
130
185
185
64
64
84
64
84
84
116
0.3
0.7
2.1
0.6
0.7
1.3
1.9
9
9
4
9
4
4
4
1
1
1
1
1
1
1
28.0
28.0
38.0
28.0
39.0
39.0
56.0
0.43
0.43
0.78
0.43
0.79
0.79
1.70
1.29
1.29
2.34
1.29
2.37
2.38
5.12
105
130
105
185
130
185
185
64
64
84
64
84
84
116
0.4
0.6
0.6
0.6
0.7
1.0
1.2
9
9
4
9
4
4
4
1
1
1
1
1
1
1
26.0
26.0
36.0
26.0
37.0
37.0
53.0
0.37
0.36
0.69
0.37
0.70
0.69
1.46
0.13
1.09
2.09
1.13
2.10
2.08
4.40
105
130
105
185
130
185
185
64
64
84
64
84
84
116
0.3
0.4
0.6
0.5
0.8
1.0
2.1
9
9
4
9
4
4
4
1
1
1
1
1
1
1
25.0
25.0
35.0
25.0
35.0
36.0
51.0
0.30
0.31
0.60
0.33
0.62
0.62
1.18
0.90
0.94
1.82
0.99
1.87
1.87
3.56
105
130
105
185
130
185
185
64
64
84
64
84
84
116
0.4
0.4
0.6
0.5
0.8
1.0
1.9
9
9
4
9
4
4
4
1
1
1
1
1
1
1
24.0
24.0
33.0
24.0
34.0
34.0
49.0
0.29
0.27
0.53
0.30
0.56
0.56
1.08
0.87
0.83
1.59
0.91
1.68
1.69
3.25
105
130
105
185
130
185
185
64
64
84
64
84
84
116
0.3
0.4
0.6
0.5
0.8
0.9
2.1
9
9
4
9
4
4
4
1
1
1
1
1
1
1
WEIGHT PACKAGING DRAWING
[kg]
UNIT
NO.
Note
• Other voltage, current and capacitance values are available on request
Document Number: 13039
Revision: 15-Feb-11
For technical questions, contact: [email protected]
www.vishay.com
15
Legal Disclaimer Notice
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 11-Mar-11
www.vishay.com
1