ETC 158247UH0.27A

The Reliable
Source
...
FERROPERM
for High Quality
Inductors
and
Transformers
INDUCTORS AND TRANSFORMERS
from FERROPERM UK Ltd.
FERROPERM offers a manufacturing capability for the
production of most types of high quality inductors and
transformers, including surface mounting types. Toroidal
types and wave-wound types are particular specialities.
Transformers are all produced as custom designs (see
page 16). Inductors are produced as custom designs
(see page 15) and in standard ranges which are
presented in this catalogue.
A highly flexible production facility ensures short lead
times on custom designs as well as standard products.
We can produce designs for your applications or we can
manufacture to your own designs.
Rather than trying to list all the types of inductors and
transformers FERROPERM can produce, it is easier to
list types not made:
1. ``Mains'' (50 or 60Hz) power transformers.
2. Inductors and transformers with any dimension larger
than about 300 mm.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
2
TYPE 1580
RADIO-FREQUENCY CHOKES
Core .................................................... Low-loss Iron Powder
Coating ................................................ Insulated with heat-shrink tube
Load on Terminals ............................... 2Kg max
Working Temperature .......................... -55 to +85°C ambient
Marking ............................................... Type and inductance
Inductance
Maximum Rdc Ω
Idc A
Fr MHz
D mm
µH (±10%)
@ 25ºC
@ 85ºC
Max
Typ
Max
10 *
16
25 *
40
50
63
80
100 *
125
160
200
250 *
315
400
500 *
0.3
0.7
0.9
1.3
1.6
1.7
1.9
2.0
2.3
2.6
3.0
3.4
3.9
4.5
5.2
0.4
0.9
1.1
1.7
2.0
2.2
2.4
2.6
2.9
3.3
3.8
4.3
4.9
5.6
6.5
0.9
0.6
0.6
0.5
0.5
0.5
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.2
0.2
36.0
32.0
27.0
18.0
16.0
14.0
13.0
10.0
10.0
9.0
8.0
7.0
5.5
5.0
5.5
8.0
8.0
8.0
8.0
8.0
8.5
8.5
8.5
8.5
9.0
9.0
9.0
9.0
9.0
9.0
* Preferred values
Idc max: Maximum Current at 85ºC ambient
For other temperatures use the "Load Ratings" curve 1 on page 17
To order these chokes please specify type 1580 and the inductance value.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
3
TYPE 1580 and 1580K
RADIO-FREQUENCY CHOKES
Core .................................................... Low-loss Iron Powder
Coating ................................................ 1580
None
1580K Insulated with heat-shrink tube
Load on Terminals ............................... 2Kg max
Working Temperature .......................... -55 to +85°C ambient
Marking ............................................... 1580
None
1580K Type and inductance
Inductance
Rdc Ω
µH (±10%)
Typ
1580
1580K
Typ
1580
1580K
1.0
2.5
5.0
10.0
11
19
32
47
0.22
0.16
0.12
0.12
0.16
0.12
0.09
0.09
3.3
2.0
1.4
1.0
8.5
10.0
11.0
14.0
10.0
11.5
12.5
16.0
Maximum Idc A
Fr MHz
Maximum D mm
Idc max: Maximum Current at 85ºC ambient
For other temperatures use the "Load Ratings" curves on page 17
Curve1for1580KandCurve2for1580
To order these chokes please specify the type number and the inductance value.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
4
TYPE 1582
RADIO-FREQUENCY CHOKES
Core .................................................... Thermoset Plastic up to 0.68µH
Low-loss Ferrite above 0.68µH
Coating ................................................ Moulded Polypropylene
Load on Terminals ............................... 2Kg max
Working Temperature .......................... -55 to +85°C ambient
Marking ............................................... Type, inductance and current
Inductance
Q
@
Fr MHz
Rdc Ω
Idc A
µH (±10%)
Typ
F MHz
Typ
Typ
Max
0.10
0.15
0.22
0.33
0.47
0.68
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
150
220
330
470
680
1000
65
65
55
55
55
45
45
65
60
50
50
60
50
55
65
85
70
65
65
80
80
80
80
85
85
25
25
25
25
25
15
15
8.0
8.0
8.0
8.0
8.0
8.0
2.5
2.5
2.5
2.5
2.5
1.5
0.8
0.8
0.8
0.8
0.8
0.8
>400
>400
>400
350
320
290
190
155
130
110
95
85
65
55
45
35
20
16
14
9.5
8.0
9.5
6.5
5.0
3.0
0.025
0.035
0.045
0.055
0.07
0.09
0.04
0.05
0.06
0.07
0.12
0.22
0.35
0.6
1.1
2.0
2.5
3.0
4.0
5.8
7.3
12
20
24
30
3.0
2.5
2.0
2.0
1.7
1.5
2.2
2.0
1.8
1.7
1.3
1.0
0.75
0.6
0.43
0.3
0.27
0.25
0.22
0.23
0.2
1.16
0.12
0.11
0.1
Idc max: Maximum Current at 85ºC ambient
For other temperatures use the "Load Ratings" curve 2 on page 17
To order these chokes please specify type 1582 and the inductance value.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
5
TYPE 1583
RADIO-FREQUENCY CHOKES
Core .................................................... Low-loss Ferrite
Coating ................................................ Moulded Polypropylene
Load on Terminals ............................... 2Kg max
Working Temperature .......................... -55 to +85°C ambient
Marking ............................................... Type, inductance and current
Inductance
Q
@
Fr MHz
Rdc Ω
Idc A
µH (±10%)
Typ
F MHz
Typ
Typ
Max
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
150
220
330
470
680
1000
90
85
75
55
40
40
50
50
50
60
80
100
60
70
70
75
80
80
70
8.0
8.0
8.0
8.0
8.0
8.0
8.0
2.5
2.5
2.5
2.5
2.5
0.8
0.8
0.8
0.8
0.8
0.8
0.5
200
160
140
120
100
85
70
55
45
35
32
25
15
12
11
8
8
6
5
0.015
0.02
0.025
0.035
0.04
0.07
0.16
0.32
0.54
0.85
1.5
2.7
1.8
3.6
4.3
8.3
10
16
20
3.0
3.0
3.0
3.0
2.7
2.0
1.25
1.0
0.75
0.6
0.45
0.3
0.4
0.3
0.25
0.2
0.17
0.14
0.12
Idc max: Maximum Current at 85ºC ambient
For other temperatures use the "Load Ratings" curve 2 on page 17
To order these chokes please specify type 1583 and the inductance value.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
6
TYPE 1585
INTERFERENCE SUPPRESSION CHOKES
INS (insulated) types only have axial leads: see top drawing.
LAC (lacquered) types can have axial or radial leads:
see top drawing for axial style
see bottom drawing for radial style
Core .................................................... Ferrite
Coating (LAC types) ............................ Polyurethane Lacquer
Coating (INS types) ............................. Insulated with heat-shrink tube
Working Temperature ......................... -55 to +85°C ambient
Marking (LAC types) ............................ None
Marking (INS types) ............................. Type, inductance and current
Idc max: Maximum Current at 85ºC ambient
For other temperatures use the "Load Ratings" curves on page 17
Curve1forINStypesandCurve2forLACtypes
For dimensions see next page
To order these chokes please specify type 1585 and the inductance value, current rating and
type.
e.g. "1585 10µH 3A LAC"
or
"1585 25µH 6A INS"
Axial leads will be supplied unless radial are specified. Radial are only available on LAC types.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
7
TYPE 1585
INTERFERENCE SUPPRESSION CHOKES
Inductance
µH (±20%)
4
6
10
15
25
3
4
6
10
15
25
50
100
500
1000
4
6
10
15
25
LAC
2
4
6
10
15
25
4
6
10
15
25
Maximum Idc A
4
6
8
Rdc mΩ
Fr MHz
INS
Typ
Typ
D
×
L
d
1.5
35
38
43
70
110
140
110
90
65
45
3
3
3
5
6
×
×
×
×
×
11
15
30
20
20
0.35
0.4
0.4
0.4
0.35
2
18
20
38
50
68
130
95
70
45
45
3
3
5
6
7
×
×
×
×
×
15
20
20
20
22
0.5
0.5
0.5
0.5
0.5
13
20
25
37
45
60
90
200
350
110
90
70
55
40
3
2.5
1
0.6
3.5
5.5
6.5
7.5
7.5
10.5
10.5
14
15.5
×
×
×
×
×
×
×
×
×
20
20
20
22
30
22
22
40
42
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
4
10
13
16
20
25
100
80
70
55
45
6
7
8
8
8
×
×
×
×
×
20
20
22
30
35
0.8
0.8
0.8
0.8
0.8
6
8
9.5
12
15
19
110
80
65
55
45
7.5
8.5
8.5
8.5
8.5
×
×
×
×
×
20
22
30
35
40
0.95
0.95
0.95
0.95
0.95
3
Dimensions in mm *
* D & L are maximum dimensions for LAC types. Please add 1mm to D and 5mm to L for maximum
dimensions for INS types.
Dimension d values are nominal wire diameters.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
8
TYPE 15EC24
GENERAL PURPOSE INDUCTORS
Core .................................................... Ferrite
Coating ................................................ Epoxy
Insulation withstand voltage ................. 250V a.c.
Load on Terminals ............................... 1Kg max
Working Temperature .......................... -55 to +85°C ambient
Marking ............................................... Standard colour banding
(Base unit 1µH)
Inductance
Q
@
Fr MHz
Rdc Ω
Idc mA
µH
Min
F MHz
Min
Max
Max
0.22 ±20%
0.47 ±20%
1.0 ±10%
2.2 ±10%
4.7 ±10%
10 ±10%
22 ±10%
47 ±10%
100 ±10%
220 ±10%
470 ±10%
1000 ±10%
40
40
40
50
45
40
50
60
60
60
60
60
25.2
25.2
25.2
7.96
7.96
7.96
2.52
2.52
2.52
0.796
0.796
0.796
380
300
180
110
50
22
13
8.5
5.5
4.0
2.5
1.1
0.08
0.1
0.15
0.25
0.35
0.72
1.2
2.3
3.5
5.7
11.6
30
1150
1000
815
630
530
370
385
205
165
130
90
60
To order these chokes please specify type 15EC24 and the inductance value.
Certain other inductance values are available to special order. Please contact our Sales Office
with your requirements.
Examples of colour banding:1st Fig
UK3
2nd Fig
Multiplier
Tolerance
15EC24 u47M Yellow
Purple
Silver
Black
15EC24 m22K Red
Red
Brown
Silver
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
9
TYPE 15EC36
GENERAL PURPOSE INDUCTORS
Core .................................................... Ferrite
Coating ................................................ Epoxy
Insulation withstand voltage ................. 250V a.c.
Load on Terminals ............................... 1Kg max
Working Temperature .......................... -55 to +85°C ambient
Marking ............................................... Standard colour banding
(Base unit 1µH)
Inductance
Q
@
Fr MHz
Rdc Ω
Idc mA
µH
Min
F MHz
Min
Max
Max
0.22 ±20%
0.47 ±20%
1.0 ±10%
2.2 ±10%
4.7 ±10%
10 ±10%
22 ±10%
47 ±10%
100 ±10%
220 ±10%
470 ±10%
1000 ±10%
25
25
45
55
70
85
60
45
30
70
60
50
25.2
25.2
25.2
7.96
7.96
7.96
2.52
2.52
2.52
0.796
0.796
0.796
380
250
157
110
80
45
9.9
6.3
4.8
3.0
2.3
1.4
0.21
0.36
0.19
0.28
0.39
0.58
0.84
1.22
1.8
5.1
7.7
14
880
650
920
750
620
500
410
340
275
155
126
100
To order these chokes please specify type 15EC36 and the inductance value.
Certain other inductance values are available to special order. Please contact our Sales Office
with your requirements.
Examples of colour banding:1st Fig
UK3
2nd Fig
Multiplier
Tolerance
15EC36 u47M Yellow
Purple
Silver
Black
15EC35 m22K Red
Red
Brown
Silver
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
10
TYPE 1588
RADIO-FREQUENCY CHOKES
Core .................................................... Thermoset Plastic up to 1.0µH
Low-loss Ferrite above 1.0µH
Coating ................................................ Polyurethane Lacquer
Load on Terminals ............................... 2Kg max
Working Temperature .......................... -55 to +85°C ambient
Marking ............................................... Type and inductance
Inductance
Q
@
Fr MHz
Rdc Ω
Idc A
µH (±10%)
Typ
F MHz
Typ
Typ
Max
0.1
0.15
0.22
0.33
0.47
0.68
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
50
50
50
50
50
50
50
70
70
60
65
70
70
60
50
60
65
70
70
25
25
25
25
25
25
25
8.0
8.0
8.0
8.0
8.0
8.0
2.5
2.5
2.5
2.5
2.5
2.5
680
600
510
410
330
280
250
150
125
100
85
70
60
45
35
25
21
17
13
0.1
0.13
0.16
0.18
0.28
0.3
0.42
0.25
0.3
0.35
0.5
1.1
1.8
2.6
5
6.2
7.5
8.5
11.5
1.3
1.1
1.0
0.9
0.8
0.75
0.65
0.8
0.75
0.7
0.6
0.4
0.3
0.25
0.18
0.16
0.15
0.14
0.12
Idc max: Maximum Current at 85ºC ambient
For other temperatures use the "Load Ratings" curve 2 on page 17
To order these chokes please specify type 1588 and the inductance value.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
11
Type 1586
INTERFERENCE SUPPRESSION CHOKES
Core ....................................
Ferrite.
Coating ...............................
Insulated with heat-shrink tube.
Working Temperature .........
-55 to +85 °C ambient.
Marking ..............................
Type, inductance and current.
Inductance
Idc max.
Rdc Typ.
Fr Typ.
Dimensions
uH (±20%)
A
milliOhms
MHz
D×L
5.6
8
17
83
8 × 26
10
5
35
65
7.5 × 26
15
4
50
55
7.3 × 26
33
3.5
70
7
11 × 26
68
3
100
5
11 × 26
100
2.5
150
3.5
10 × 26
150
1.8
300
2.5
9.8 × 26
330
1.4
500
2
11 × 26
680
1
1000
1.1
10 × 26
1000
0.8
1500
0.85
9.8 × 26
1500
0.7
2000
0.79
10.3 × 26
3300
0.5
4000
0.46
10.6 × 26
6800
0.35
8000
0.36
10.8 × 26
10000
0.3
12000
0.25
9.8 × 26
Imax: Maximum current at 40 °C ambient.
For other temperatures use the ``Load Ratings'' curve 3 shown on page 17.
To order these chokes please specify type 1586, the inductance value and the current
rating. e.g. ``1586 10µH 5A''.
Dimension are in mm and are nominal values.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
12
Types 15SC137, 177, 178,
COMMON MODE SUPPRESSION CHOKES
Type
I max *
Rdc Typ.
Number
(min.) mH
A
mOhms
15 SC 137
10
2
150
15 SC 177
2.2
4
44
15 SC 178
1.1
6
21
15 SC 179
0.6
8
11
Insertion Loss up to 50 MHz ..................
> 20 dB typical
Insertion Loss up to 1 GHz ....................
> 10 dB typical
Insulation Test ......................................
3kV dc.
Core ......................................................
Toroidal Ferrite
Working Temperature ...........................
-55°C to +85°C
Double Insulated
common mode
choke for
interference
suppression of
incoming mains
supplies.
These chokes are
sometimes called
current compensated chokes.
To order these chokes please specify the type number.
* For other temperatures use the ``Load Ratings'' curve 2 on page 17.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
13
Types 15SC 216, 217, 218, 219, 63, 108
SINGLE LINE SUPPRESSION CHOKES
D
50 min.
5 min.
H
Single line chokes for suppression in mains supply lines in
equipment utilising SCRs or Triacs phase angle control
applications. e.g. Light dimmers or motor speed controllers.
Core ....................................
Iron Dust.
Terminations .......................
Wire ended.
Working Temperature .........
-55 to +85 °C ambient.
Marking ...................... ........
None.
Type
Inductance
* I max.
Rdc Typ.
Dimensions
number
mH-20+80%
A
Ohms
D×H
15 SC 216
4
0.4
1.8
20 × 8
15 SC 217
4
1
0.9
25 × 10
15 SC 218
2.9
1.6
0.5
30 × 15
15 SC 219
2.4
2
0.4
32 × 16
15 SC 63
0.8
5
0.15
45 × 17
15 SC 108
0.8
10
0.06
54 × 23
All chokes are supplied with 50mm minimum lead length of which at least 5mm is
solder-dipped.
Note that type 15 SC 108 is bifilar wound with two wires. These must be connected in
parallel for correct operation.
* Imax = Maximum current at 40 °C ambient. For other temperatures use the ''Load
Ratings'' curve 2 on page 17
To order these chokes please specify the type number.
Dimension are in mm and are nominal values.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
14
CUSTOM INDUCTORS
from FERROPERM UK Ltd.
If you already have inductor designs, we will be pleased to quote for their manufacture. Just send us your drawings!
If you would like us to design inductors to meet your requirements, please send us
the following information. If you do not have all the information available, please just
give what you can.
1.
Specify the application. (For example, Energy Storage Choke for a Switched
Mode Power Supply). Please give as much information as you can.
2.
Specify the maximum dimensions of the space you have available for the
inductor.
3.
Specify if you require surface mounting or through-hole mounting.
4.
If you have a preference for a particular hardware design (for example rod or
toroidal), please state it.
5.
Specify your estimated requirements of quantities and delivery dates both for
short term and long term. This is important because it may influence what hardware
is specified for the design.
6.
If you have a target or maximum price level, please state it.
7.
Specify maximum average direct current flow.
8.
Specify maximum peak current flow.
9.
Sketch or describe any alternating current waveform (other than interference
current). If the waveform is variable, please specify the extremes.
FOR ENERGY STORAGE CHOKES (INDUCTORS):
10.
Specify inductance and widest acceptable tolerance at near zero current, at
maximum average current and at maximum peak current.
FOR ALL OTHER INDUCTORS:
10.
EITHER specify inductance and widest acceptable tolerance
OR specify minimum required impedance at particular frequencies or sketch
a
graph of minimum required impedance
versus frequency.
11.
Specify if common mode (current compensated) design is required.
(Examples of common mode chokes are shown on page 13.)
12.
Specify maximum working voltage between windings if common mode.
13.
If this working voltage is a.c., please specify the frequency.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
15
CUSTOM TRANSFORMERS
from FERROPERM UK Ltd.
If you already have transformer designs, we will be pleased to quote for their
manufacture. Just send us your drawings!
If you would like us to design transformers to meet your requirements, please send
us the following information. If you do not have all the information available, please
just give what you can.
1.
Specify the application. (For example, Switched Mode Power Supply (SMPS)
in an instrument). Please give as much information as you can.
2.
Indicate by a schematic or describe how the transformer is driven and used.
(For example, push-pull FET drive in a SMPS). Please give as much information as
you can.
3.
Draw a schematic of all windings with turns ratios and widest acceptable
tolerance of turns ratios. Indicate polarity of windings where it is important. For
windings with one or more taps between the ends, please make clear what turns
ratios are required for each section of the winding!
4.
Specify what voltage isolation requirements there are between all windings.
5.
Draw or describe the voltage waveform which will be applied to the primary
winding. If the waveform is variable, please specify the extremes.
6.
Specify maximum working currents to be drawn from all secondary windings.
7.
If occasional overload conditions have to be met, please specify these
seperately.
8.
Specify the maximum dimensions of the space you have available for the
transformer.
9.
Specify if you require surface mounting or through-hole mounting.
10.
If you have a preference for a particular hardware design (for example ETD,
RM or toroidal), please state it.
11.
Specify your estimated requirements of quantities and delivery dates both for
short term and long term. This is important because it may influence what hardware
is specified for the design.
12.
UK3
If you have a target or maximum price level, please state it.
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
16
INDUCTORS AND TRANSFORMERS
from FERROPERM UK Ltd.
Whilst every care was taken to avoid any mistakes in the compilation of this
catalogue, no responsibility can be assumed for any errors which may have
occured in it.
In line with Ferroperm's policy of continual development, Ferroperm
reserves the right to alter specifications of any products without notice.
UK3
Ferroperm UK Ltd. Wrexham. LL14 6HA. Tel +44 1978 823 990 Fax +44 1978 810 128
17
The Reliable
Source
..
FERROPERM
. . . serving
the
electronics
industry
Other products from Ferroperm include . . .
Filtered Sub-D Connectors
Soft magnetic Ferrites & Iron Dust Cores
Hard magnetic Ferrites
Piezo Electric Ceramics
Thin Film Optical Interference Filters
FERROPERM UK LTD.
Vauxhall Industrial Estate,
Ruabon, Wrexham,
Clwyd LL14 6HA.
United Kingdom.
Phone +44 1978 823 990
Fax +44 1978 810 128
Catch us on the web at
http://www.ferroperm.co.uk
Email us on
[email protected]