MEDER electronic DIP Series Molded DIP Reed Relays DESCRIPTION The DIP series is a very compact design having a low profile package and a high profile package. This series is compatible with all DIP relays. CHARACTERISTICS FEATURES • High resistance option available • Diode option available • Low profile package • Standard pin configurations • IC-pin compatible • 4.25 kVDC breakdown voltage for pin out 13 • UL approval DIMENSIONS All dimensions in mm [inches] www.meder.com 139 DIP Series MEDER electronic Molded DIP Reed Relays ORDER INFORMATION Part Number Example DIP12 - 1A75 - 13L 12 is the nominal voltage 1A is the contact form 75 is the switch model 13 is the pin out L is the option Series Nominal Voltage Contact Form Switch Model Pin Out Option () Version with magn. Shield DIP XX - XX XX - XX X 1A 72, 75 11, 13* 1B 72 19 2A 72 21 1C 90 51 05, 12, 15, 24 Options 05, 12,15. 24 *Selects 4-25 (3.0 kVRMS) breakdown voltage contact to coil. PIN OUT www.meder.com 140 L(M), D(Q),E(R), F(S) MEDER electronic DIP Series Molded DIP Reed Relays OPTIONS ( ) Versions with magnetic shield + + OPTIONS DEPENDENCE ON CASE SIZES Contact Form Package Size Options Pin Out L Low Profile 1A High Profile 11 X 13 X D E F M Q X X X R S X 11 X 13 X X X X X X 1B High Profile 19 X X 2A High Profile 21 X X X X X X X X X X X X X X X 1C Low Profile X 51 High Profile L D E F = = = = M Q = = R S = = No option With Diode between pin 2 and 6 (Pin 2 is positive) Internal shield on pin 9 With Diode between pin 2 and 6 (Pin 2 is positive) and Internal shield on pin 9 External magnetic shield External magnetic shield and diode between pin 2 and 6 (Pin 2 is positive) External magnetic shield and internal shield on pin 9 External magnetic shield and with diode between pin 2 and 6 (Pin 2 is positive) and internal shield on pin 9 www.meder.com 141 DIP Series MEDER electronic Molded DIP Reed Relays RELAY DATA Switch Model → Contact Form → All Data at 20° C Contact Ratings Conditions Switch 72 Form A / B Switch 75 Form A Switch 90 Form C Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Switching Power Any DC combination of V & A not to exceed their individual max.‘s 15 10 3 W Switching Voltage DC or peak AC 200 500 175 V Switching Current DC or peak AC 1.0 0.5 0.25 A Carry Current DC or peak AC 1.25 1.0 1.2 A Static Contact Resistance w/ 0.5 V & 10mA 150 200 150 mΩ Dynamic Contact Resistance Measured w/ 0.5 V & 50mA , 1.5 ms after closure 200 200 250 mΩ Insulation Resistance across Contacts 100 volts applied 1012 1012 1012 1012 109 1012 Ω Breakdown Voltage across Contact Across contacts Contact to coil 250 1500** 1500* 1500** 200 1500 VDC Operation Time incl. Bounce Measured w/ 100 % overdrive 0.5 0.5 0.7 ms Release Time Measured w/ no coil suppression 0.1 0.1 1.0 ms Capacitance at 10 kHz cross contact 0.2 2.0 0.4 2.0 1.0 3.0 pF 1000 500 100 106 Cycles Life Expectancies Switching 5 V - 10 mA DC only & <10 pF stray cap. For other load requirements please see our life test section on P. 112. Environmental Data Shock Resistance 1/2 sinus wave duration 11 ms 50 50 30 g Vibration Resistance From 10 - 2000 Hz 20 20 10 g Ambient Temperature 10°C/ minute max. allowable -20 70 -20 70 -20 70 o C Stock Temperature 10°C/ minute max. allowable -35 95 -35 95 -35 95 o C Soldering Temperature 5 sec. 260 o C 260 * 600 VDC with 5V coil, 1000 VDC with 12V coil. ** Selects Pin out 13 and 425 kVDC (3.0 kVRMS) breakdown voltage contact to coil. www.meder.com 142 260 MEDER electronic DIP Series Molded DIP Reed Relays COIL DATA Contact Form Switch Model All Data at 20 °C 1A 1B ** 2A 1C 72 75 72 72 90 Coil Voltage Coil Resistance Pull-in Voltage Drop-out Volage Nominal Coil Powe VDC Ω VDC VDC mW Nom. Max. Min. Typ. Max. Max. Min. Typ. 5 7.5 450 (180) 500 (200) 550 (220) 3.5 0.75 50 12 16 900 1000 1100 8.4 1.8 145 15 20 1800 2000 2200 10.5 2.2 115 24 30 1800 2000 2200 16.8 3.6 290 5 7.5 450 500 550 3.5 0.75 50 12 16 900 1000 1100 8.4 1.8 145 15 20 1800 2000 2200 10.5 2.2 115 24 30 1800 2000 2200 16.8 3.6 290 5 7.5 180 200 220 3.5 0.75 125 12 16 450 500 550 8.4 1.8 290 15 20 1800 2000 2200 10.5 2.2 115 24 30 1800 2000 2200 16.8 3.6 290 5 7.5 180 200 220 3.5 0.75 125 12 16 450 500 550 8.4 1.8 290 15 20 1800 2000 2200 10.5 2.2 115 24 30 1800 2000 2200 16.8 3.6 290 () For Switch 75. * The pull-in / drop-out voltage and coil resistance will change at rate of 0.4% per °C. ** Re-closure of Form B may occur if the max. coil voltage is exceeded. Coil polarity on Form B must be observed. Pin 2 is positive. www.meder.com 143