PANASONIC DS2Y-S-DC5V

DS2Y
Miniature Relay
DS2Y RELAYS
FEATURES
TYPICAL APPLICATIONS
1. 2 Form C contact
2. High sensitivity-200 mW nominal
operating power
3. High breakdown voltage
1500 V FCC surge between open
contacts
4. DIP-2C type matching 16 pin IC
socket
5. Sealed construction
1. Telecommunication equipment
2. Office equipment
3. Computer peripherals
4. Security alarm systems
5. Medical equipment
RoHS compliant
ORDERING INFORMATION
DS2Y-S
Operating function
Nil: Single side stable
Nominal coil voltage
DC 3, 5, 6, 9, 12, 24, 48 V
Note: UL/CSA approved type is standard.
TYPES
Contact arrangement
Nominal coil voltage
2 Form C
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
48V DC
Single side stable type
Part No.
DS2Y-S-DC3V
DS2Y-S-DC5V
DS2Y-S-DC6V
DS2Y-S-DC9V
DS2Y-S-DC12V
DS2Y-S-DC24V
DS2Y-S-DC48V
Standard packing: Tube: 50 pcs.; Case: 500 pcs.
ASCTB16E 201209-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
DS2Y
RATING
1. Coil data
Single side stable type
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
3V DC
66.7mA
45Ω
5V DC
6V DC
9V DC
12V DC
24V DC
48V DC
40mA
33.3mA
22.2mA
16.7mA
8.3mA
6.3mA
125Ω
180Ω
405Ω
720Ω
2,880Ω
7,680Ω
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
Nominal operating
power
Max. applied voltage
(at 50°C 122°F)
200mW
200%V of
nominal voltage
300mW
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Initial contact resistance, max.
Contact material
Max. switching power
Max. switching voltage
Max. switching current
Max. carrying current
Minimum operating power
Nominal operating power
Specifications
2 Form C
Max. 50 mΩ (By voltage drop 6 V DC 1A)
Ag+Au clad
60 W, 62.5 VA (resistive load)
220 V DC, 250 V AC
2A
3A
Approx. 98 mW (147 mW: 48 V)
Approx. 200 mW (300 mW: 48 V)
Insulation resistance (Initial)
Min. 100MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Between open contacts
Between contact sets
Between contact and coil
FCC surge breakdown voltage between contacts
and coil
Temperature rise (at 20°C 68°F)
Breakdown voltage
(Initial)
Electrical
characteristics
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Electrical
Shock resistance
Mechanical
characteristics
Expected life
Conditions
Conditions for operation, transport and storage*
Max. operating speed (at rated load)
Unit weight
750 Vrms for 1min. (Detection current: 10mA.)
1,000 Vrms for 1min. (Detection current: 10mA.)
1,000 Vrms for 1min. (Detection current: 10mA.)
1,500 V
Max. 65°C with nominal coil voltage across coil and at nominal switching capacity
Approx. 4 ms [approx. 3 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Approx. 3 ms [approx. 3 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Min. 490 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 108
5×105 (1 A 30 V DC), 105 (2 A 30 V DC)
Ambient temperature: –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
60 cpm
Approx. 4g .14oz
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (TX/TX-S/TX-D relay AgPd contact type are available for low level load switching [10V DC, 10mA max. level])
*2 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*3 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB16E 201209-T
DS2Y
REFERENCE DATA
1. Maximum switching capacity
2. Coil temperature rise (Single side stable)
3. Operate/release time for single side stable
(Without diode)
Tested sample: DS2Y-S-DC12V, 5 pcs.
Measured portion: Inside the coil
Ambient temperature: 21°C to 25°C 70°F to 77°F
Tested sample: DS2Y-S-DC12V, 10 pcs.
Ambient temperature: 20°C 68°F
1,000 V
5
Operate time
Release time
Temperature rise, °C
100 V
10 V
4
Time, ms
Contact voltage
3A
30
2A
0A
3
Mean value
Mean value
2
20
1
10 mA
10 µA
100 mA
100
1A
Switching current
0
110
Coil applied voltage, %V
4-(2) Influence of adjacent mounting
Tested sample: DS2Y-S-DC12V, 10 pcs.
Ambient temperature: 20°C 68°F
Tested sample: DS2Y-S-DC12V, 10 pcs.
Ambient temperature: 20°C 68°F
TEST METHOD
1. Apply nominal voltage to No. (1) and (3) DS2Y
relays.
2. Measure pick-up voltage and drop-out voltage of
No. (2) relay when inter-relay distance ( ) changes.
TEST METHOD
1. Apply nominal voltage to No. (1) and (3) DS2Y
relays.
2. Measure pick-up voltage and drop-out voltage of
No. (2) relay when inter-relay distance ( ) changes.
(1)
OFF
10
(2)
(3)
OFF
Pick-up/Drop-out voltage, V
Pick-up/Drop-out voltage, V
4-(1) Influence of adjacent mounting
8
ON
ON
Pick-up voltage
6
OFF
OFF
4
Drop-out voltage
ON
ON
80
100
120
Coil applied voltage, %V
10
2
(1)
OFF
(2)
(3)
OFF
8
Pick-up voltage
ON
ON
OFF
OFF
ON
ON
6
4
Drop-out voltage
2
0
0
5
10
15
.197 .394 .591
Inter-relay distance, mm inch
DIMENSIONS (mm inch)
5
10
15
.197 .394 .591
Inter-relay distance, mm inch
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
Single side stable
CAD Data
External dimensions
PC board pattern (Copper-side view)
(Deenergized position)
8-0.9 dia.
8-.035 dia.
9.9
.390
20
.787
2.54
.100
9.3
.366
5.08 5.08
.200 .200
7.62
.300
2.0
.078
0.6
.024
5.6
.220
7.62
.300
9
11
13
N.O. N.C. COM
16
–
N.O. N.C. COM
8
6
4
+
1
2.54
.100
0.6
.024
0.6
.024
Schematic (Bottom view)
3.4
.134
7.62
.300
0.3
.012
matching 16 pin IC socket
Tolerance: ±0.1 ±.004
Direction indication*
*A polarity bar shows the relay direction.
General tolerance: ±0.3 ±.012
For general cautions for use,
please refer to the “Cautions for
use of Signal Relays” or “General
Application Guidelines”.
ASCTB16E 201209-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/