PANASONIC ACNH3112

CN-H (ACNH)
HIGH LOAD RELAY
FOR SMART J/B
CN-H RELAYS (ACNH)
FEATURES
TYPICAL APPLICATIONS
• Best space savings in its class.
• Large capacity switching despite
small size. Can replace micro ISO
terminal type relays.
• Terminals for PC board pattern
designs are easily allocated.
• Sealed type
Head lamp, Fog lamp, Fan motor, EPS,
Defogger, Seat heater, etc.
RoHS compliant
ORDERING INFORMATION
ACNH
Contact arrangement
3: 1 Form A
Pick-up voltage
1: Max. 5.5V DC
2: Max. 6.5V DC
Coil voltage (DC)
12: 12V
TYPES
Contact arrangement
Nominal coil voltage
1 Form A
12V DC
Pick-up voltage (at 20°C 68°F)
Max. 6.5 V DC (Initial)
Max. 5.5 V DC (Initial)
Part No.
ACNH3212
ACNH3112
Standard packing; Carton (tube): 50 pcs.; Case: 1,000 pcs.
RATING
1. Coil data
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
12 V DC
Max. 6.5 V DC
(Initial)
Max. 5.5 V DC
(Initial)
Min. 1.0 V DC
(Initial)
Min. 0.8 V DC
(Initial)
Panasonic Corporation
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
37.5 mA
320Ω
450 mW
53.3 mA
225Ω
640 mW
Usable voltage range
10 to 16 V DC
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB223E 201208-T
CN-H (ACNH)
2. Specifications
Characteristics
Contact
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Specifications
1 Form A
Typ5mΩ (By voltage drop 6 V DC 1 A)
Ag alloy (Cadmium free)
30A 14V DC
<450mW>
35A/1 h, 45A/2 min. at 20°C 68°F
30A/1 h, 40A/2 min. at 85°C 185°F
25A/1 h, 35A/2 min. at 110°C 230°F
<640mW>
30A/1 h, 40A/2 min. at 20°C 68°F
25A/1 h, 35A/2 min. at 85°C 185°F
20A/1 h, 30A/2 min. at 110°C 230°F
20A 14V DC (450mW) at 110°C 230°F, 15A 14V DC (640mW) at 110°C 230°F
450 mW (for pick-up voltage max. 6.5 V DC), 640 mW (for pick-up voltage max. 5.5 V DC)
1A 14V DC
Max. carrying current
Rating
Continuous carrying current
Nominal operating power
Min. switching capacity (resistive load)*1
Insulation resistance (Initial)
Electrical
characteristics
Mechanical
characteristics
Min. 100 MΩ (at 500V DC, Measurement at same location as “Breakdown voltage” section.)
Between open contacts
Between contacts and coil
Operate time (at nominal voltage)
Release time (at nominal voltage)
Functional
Shock resistance
Destructive
Functional
Vibration resistance
Destructive
Breakdown voltage
(Initial)
Mechanical
Expected life
Conditions
Electrical
Conditions for operation, transport and storage
Mass
500 Vrms for 1 min. (Detection current: 10mA)
500 Vrms for 1 min. (Detection current: 10mA)
Max. 10ms (at 20°C 68°F, excluding contact bounce time) (Initial)
Max. 10ms (at 20°C 68°F) (Initial) (without protective element)
Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)
10 Hz to 100 Hz, Min. 44.1m/s2 {4.5G} (Detection time: 10µs)
10 Hz to 500 Hz, Min. 44.1m/s2 {4.5G}
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 cpm)
<Resistive load>
Min. 105 (at nominal switching capacity, operating frequency: 1s ON, 1s OFF)
<Motor load>
Min. 3×105 (at inrush 84 A, steady 18 A, 14 V DC operating frequency: ON 2s, OFF 5s)
<Lamp load>
Min. 2×105 (at inrush 84 A, steady 12 A, 14 V DC operating frequency: ON 1s, OFF 14s)
Ambient temperature: –40°C to +110°C –40°F to +230°F
Humidity: 2% R.H. to 85% R.H. (Not freezing and condensing at low temperature)
Approx. 9 g .32 oz
Note: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
REFERENCE DATA
1-(1). Coil temperature rise
1-(2). Coil temperature rise
Sample: ACNH3212, 3pcs
Measured portion: Inside the coil
Contact carrying current: 10A, 20A, 30A
Ambient temperature: 25°C 77°F
Sample: ACNH3212, 3pcs
Measured portion: Inside the coil
Contact carrying current: 10A, 20A
Ambient temperature: 110°C 230°F
20
Temperature rise, °C
100
30A
80
20A
60
10A
40
Coil applied voltage, VDC
120
120
Temperature rise, °C
2. Ambient temperature and operating voltage
range
100
80
60
20A
40
10A
20
0
10
Operating voltage range
15
10
Pick-up voltage: ACNH3212
(cold start)
5
Pick-up voltage: ACNH3112
(cold start)
20
12
14
16
18
0
10
Coil applied voltage, V
ASCTB223E 201208-T
Panasonic Corporation
12
14
16
18
Coil applied voltage, V
Automation Controls Business Unit
0
-40 -20
0
20
40
60
80 100 110 120
Ambient temperature, °C
industrial.panasonic.com/ac/e/
CN-H (ACNH)
3-(1). Distribution of pick-up and drop-out
voltage
3-(2). Distribution of pick-up and drop-out
voltage
Sample: ACNH3212, 20pcs.
Sample: ACNH3112, 20pcs.
20
20
Pick-up voltage
Drop-out voltage
Pick-up voltage
Drop-out voltage
15
Quantity, n
Quantity, n
15
10
10
5
5
0
0
0
0
1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
Voltage, V
1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
Voltage, V
4-(1). Distribution of operate and release time
4-(2). Distribution of operate and release time
Sample: ACNH3212, 20pcs.
Sample: ACNH3112, 20pcs.
20
20
Operate time
Release time
Operate time
Release time
15
Quantity, n
Quantity, n
15
10
5
10
5
0
0
0
0
1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
Time, ms
1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
Time, ms
5. Electrical life test (Resistive load)
14V DC
7
6
5
Change of contact resistance
30
Contact welding: 0 time
Miscontact: 0 time
Max.
x
Min.
Pick-up voltage
4
3
Max.
x
Min.
2
Contact resistance, mΩ
Circuit:
Change of pick-up and drop-out voltage
Pick-up and drop-out voltage, V
Sample: ACNH3212, 6pcs.
Load: Resistive load (NO side: 30A 14V DC)
Operating frequency: ON 1s, OFF 1s
Ambient temperature: Room temperature
15
10
5
1
5
No. of operations, × 104
20
Max.
Drop-out voltage
0
0
25
0
0
10
x
Min.
5
No. of operations, × 104
10
6-(1). Electrical life test (Motor load)
Change of pick-up and drop-out voltage
Circuit:
14V DC
M
Pick-up and drop-out voltage, V
7
6
Change of contact resistance
30
Contact welding: 0 time
Miscontact: 0 time
5
Pick-up voltage
Max.
x
Min.
4
3
Max.
x
Min.
2
Panasonic Corporation
Automation Controls Business Unit
20
15
10
5
1
15
No. of operations, × 104
25
Max.
Drop-out voltage
0
0
Contact resistance, mΩ
Sample: ACNH3212, 3pcs.
Load: inrush: 84A/steady: 18A,
radiator fan actual load (motor free)
Operating frequency: ON 2s, OFF 5s
Ambient temperature: 110°C 230°F
30
0
0
industrial.panasonic.com/ac/e/
x
Min.
15
No. of operations, × 104
30
ASCTB223E 201208-T
CN-H (ACNH)
6-(2). Electrical life test (Lamp load)
Change of pick-up and drop-out voltage
Sample: ACNH3212, 6pcs.
Load: 60W×2, inrush: 84A/steady: 12A
Operating frequency: ON 1s, OFF 14s
Ambient temperature: Room temperature
Pick-up and drop-out voltage, V
7
60W
60W
30
Max.
6
Contact resistance, mΩ
Circuit:
14V DC
Change of contact resistance
x
Min.
Pick-up voltage
5
4
Contact welding: 0 time
Miscontact: 0 time
3
Max.
x
Min.
2
Drop-out voltage
25
20
15
10
0
0
Max.
x
Min.
5
1
10
No. of operations, × 104
0
0
20
10
No. of operations, × 104
20
DIMENSIONS (mm inch)
External dimensions
PC board pattern (Bottom view)
17.0
.669
10.6
.417
2×1.6+0.1
0 dia. (hole)
2×.063+.004
dia. (hole)
0
2×1.6+0.1
0 dia. (hole)
2×.063+.004
dia. (hole)
0
1.7+0.1
0 dia. (hole)
.067+.004
dia. (hole)
0
3.0
.118
6.4 5.6
.252 .220
18.3
.720
Max. 1.0
Max. .039
A
1.2
.047
14.95
.589
0.4
.016
Tolerance: ±0.1 ±.004
3.5
.138
0.32
.013
1.2
.047
0.6
.024
1.2
.047
Schematic (Bottom view)
Pre-soldering
COM
COM
0.3
.012
5.5
14.95 .217
.589
1.1
.043
NO
Coil
3.0
.118
6.4 5.6
.252 .220
5.5
.217
Dimension:
Max. 1mm .039 inch:
1 to 3mm .039 to .118 inch:
Min. 3mm .118 inch:
Coil
General tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
* Dimensions (thickness and width) of terminal is measured before pre-soldering.
Intervals between terminals is measured at A surface level.
NOTES
Usage, transport and storage
conditions
1) Ambient temperature, humidity, and
atmospheric pressure during usage,
transport, and storage of the relay:
(1) Temperature:
–40 to +110°C –40 to +230°F
(2) Humidity: 2 to 85% RH
(Avoid freezing and condensation.)
(3) Atmospheric pressure: 86 to 106 kPa
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
(Temperature and humidity range for
usage, transport, and storage)
Humidity, %RH
85
Tolerance range
(Avoid freezing
when used at
temperatures
lower than
0°C 32°F) 5
2
–40
–40
(Avoid
condensation
when used at
temperatures
higher than
0°C 32°F)
0
+32
Temperature, °C °F
85
+185
110
+230
For general cautions for use, please refer to the “CAUTIONS FOR USE OF AUTOMOTIVE RELAYS”
ASCTB223E 201208-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/