This document was generated on 06/07/2010 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Description: 1120005030 Active BradCommunications™ Direct-Link™ PCU-ETHIO Ethernet card for EtherNet/IP Scanner/Adapter, PCI 3.3/ 5V bus, RoHS compliant Documents: Drawing (PDF) RoHS Certificate of Compliance (PDF) General Product Family Series Approvals Communication Speed Mounting Style Product Name Protocol Type Network Interface 112000 CE 10 / 100 Mbaud (Auto) N/A Direct-Link® EtherNet/IP PC Card EU RoHS China RoHS ELV and RoHS Compliant REACH SVHC Not Reviewed Halogen-Free Status Not Reviewed Need more information on product environmental compliance? Email [email protected] For a multiple part number RoHS Certificate of Compliance, click here Please visit the Contact Us section for any non-product compliance questions. Physical Channels Interface Network Connection Type Packaging Type Processor Temperature Range - Operating 1 Ethernet Ethernet: RJ45 Carton AMD SC520 0°C to +65°C Search Parts in this Series 112000Series Electrical Current - Maximum Input EMC Supply Voltage 5.5W EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, EN 61000-6-2 N/A Material Info Old Part Number DRL-EIP-PCU Reference - Drawing Numbers Sales Drawing E-112000-5030 This document was generated on 06/07/2010 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION BradCommunications™ applicomIO® Ethernet network interface cards provide powerful and reliable data acquisition for PC-based control and visualization applications. applicomIO® PCU-ETHIO Features Best Choice for controlling I/O over EtherNet/IP • Protocols: EtherNet/IP Master/Scanner EtherNet/IP Adapter • Reliable solution based on embedded protocol technology for powerful data throughput • Single-time development of API for whatever fieldbus used • “User-friendly” engineering tools for configuration and diagnostics • Remote connection through Ethernet port (for embedded system platform) • Application watchdog • Automatic I/O mapping for easy configuration • I/O exchange up to 14 Kbytes Typical Application LINUX Overview Some of the world’s most demanding high-speed control and automation applications run on standard PCs using BradCommunications™ applicomIO® fieldbus interface cards. Dedicated DCS and PLC systems have been eliminated in favor of open platforms running PC-based control systems. The benefits include: Reduced material costs Reduced development times More flexible and customizable systems Reduced field-support costs applicomIO products are design so industrial applications can be designed independently of the fieldbus used. OEMs, system integrators and end-users can take advantage of developing standard control applications as well as selecting the fieldbus connectivity required from the applicomIO product range. applicomIO products consist of a fieldbus card and engineering tools which quickly and easily setup communication. EVERYTHING is included for a successful implementation at a lower cost. • Panel PC visualization system applicomIO provides connectivity support for all popular fieldbuses including EtherNet/IP, PROFINET IO, Modbus TCP, PROFIBUS, DeviceNet and CANopen. Our cards are developed in compliance with the technical specifications of industrial organizations and comply with the applicable industrial standards. applicomIO supports up to 8 cards in a single PC and can run on various operating systems including Windows 32-bits, Linux as well as real-time OS such as VxWorks, QNX, and VenturCom RTX. Supported OS Particularly, the applicomIO® PCU-ETHIO network interface card provides high-speed deterministic communication to exchange data with industrial devices through EtherNet/IP messaging. The built-in processor handles all the protocol management to offer reliable and outstanding performance. • PC-Based Control • Robotic application Standard package • Windows 32-bit (XP , 2000, 2003 Server), VenturCom RTX Free Download • Windows XP Embedded, QNX, VxWorks, Linux, Phar Lap ETS, DOS The software package includes a common development library for all fieldbuses supported. The process data is exchanged with the control application through a shared memory where inputs/outputs are automatically mapped. To monitor the communication between the card and the control application, the library includes a watchdog feature to automatically detect software blocking. ARE YOU LOOKING FOR A REAL TURNKEY SOLUTION? applicomIO® configuration software console provides a standardized and user-friendly environment for quick development of communication applications without the worry of knowing industrial communication protocols. The console saves time during the commissioning phase by offering features such as automatic device detection, user configuration management, diagnostic information, etc. The product includes: Fieldbus interface card Engineering console for configuration and diagnostics Data Servers (OPC DA v3.0 & v2.05, Wonderware DAServer and FastDDE/SuiteLink) Development Libraries: Windows (DLL), NI (LabView), VenturCom (RTX) Static library for non-windows OS (VxWorks, QNX, Linux, etc) applicomIO® PCU-ETHIO Software tools Hardware specifications applicomIO® software tools enable fast integration of the fieldbus into your control application. No matter the fieldbus; the console remains the same. - Configuration Console - Bus interface PCI rev 2.2, 32-bit, 33 MHz, PCI Universal 3.3V/5V keying, PCI-X compatible Processor AMD SC520 - 133 MHz Memory SDRAM: 16 Mbytes Flash: 4 Mbytes Interruption Hardware Plug&Play DPRAM Address Hardware Plug&Play (32 Kbytes used per card) Dimensions (L x W) 168mm x 107mm (6.61" x 4.21") Consumption 5.5 W Operating Temperature 0º C (32º F) ↔ +65º C (149º F) Storage Temperature -40º C (-40º F) ↔ +85º C (185º F) Discrete Input 1x Opto-coupled Discrete Output 1x "WatchDog" (dry contact) EMC Compliance EN55022 Class B, EN61000-6-2, EN61000-3-2, EN61000-3-3 RoHS Compliance YES 1 Ethernet port - Device Properties - - Online Actions - Port type Ethernet port IEEE 802.3 for industrial applications Connector type BaseT (RJ45) Speed 10/100 Mbps (Auto-negotiation) LED indicators 4 LEDs - TX, RX, Link, 100 Mbps Remote Access Also usable for remote and diagnostic configuration Protocols supported Protocol Specifications EtherNet/IP EtherNet/IP - Explicit Msg and Implicit Msg (I/O Control) I/O Master/Scanner and Slave according to EtherNet/IP specifications Up to 128 simultaneous CIP based connections EtherNet/IP Devices supported: Generic and Rockwell I/O through EDS files (FlexIO, CompactLogix, etc) IP address settings configurable via the console or DHCP/BOOTP server Client DNS Supported ODVA Conformance Tested Ordering information #SAP Part Number Product description 1120005030 DRL-EIP-PCU BradCommunications™ Direct-Link™ PCU-ETHIO Ethernet card for EtherNet/IP Scanner/Adapter, PCI 3.3/ 5V bus Also available - Diagnostic and Test tools - 1120005029 DRL-EMB-PCU 1120005031 DRL-EPN-PCU To contact us: www.woodhead.com BradCommunications™ Direct-Link™ PCU-ETHIO Ethernet card for Modbus TCP/UDP Client, PCI 3.3/ 5V bus BradCommunications™ Direct-Link™ PCU-ETHIO Ethernet card for PROFINET IO-Controller & IO-Device, PCI 3.3/ 5V bus Reference Number: DW2008254 Date Published: October 2008 North America: US: + 1 800 225 7724 – Canada: +1 519 725 5136 Europe: France: +33 2 32 96 04 20 – Germany: +49 7252 94 96 0– Italy: +39 010 59 30 77 – United: Kingdom +44 1495 356300 Asia: Shanghai, China: +86 21-5835-9885 - Tianjin, China: +86 22-23321717 Singapore: +65 6268-6868 – Yamato, Japan: +81 46-265-2428 – Nagoya, Japan: +81 52-221-5950 Brad and applicomIO are registered trademarks and BradCommunications and Direct-Link are trademarks of Molex © 2008 Molex Incorporated.