OMRON E5AN-C3HMP-500

Digital Temperature Controllers
E5AN
Compact and Intelligent Temperature
Controllers
• Depth of only 78 mm.
• Various temperature inputs: thermocouple, platinum resistance
thermometer, infrared temperature sensor, and analog inputs.
• Auto-tuning and self-tuning available. Auto-tuning is possible
even while self-tuning is being executed.
• Heating or heating/cooling control is available.
• Event input allows multiple SP selection and run/stop function.
• Water-resistant construction (NEMA4X: equivalent to IP66).
• Conforms to UL, CSA, and IEC safety standards as well as CE
marking.
96(W) x 96(H) x 78(D) mm
®
Model Number Structure
■ Model Number Legend
E5AN- @ @ @ M @ -500
1
2
3
4
5
4. Option Unit
M:
Option Unit can be mounted
5. Input type
TC: Thermocouple
P:
Platinum resistance thermometer
Temperature
Controller
1. Output type
R:
Relay
Q:
Voltage (for driving SSR)
C:
Current
2. Number of alarms
3:
Three alarms
3. Heater burnout alarm
Blank:Not available
H:
Available
Ordering Information
■ Standard Models
Size
1/4 DIN
96(W) x 96(H) x
78(D) mm
Power supply
voltage
100 to 240 VAC
24 VAC/VDC
No. of alarm
points
3
3
Control output
Relay
Heater burnout
alarm
Thermocouple model Platinum resistance
thermometer model
No
E5AN-R3MTC-500
Yes
E5AN-R3HMTC-500
E5AN-R3MP-500
E5AN-R3HMP-500
Voltage
(for driving SSR)
No
E5AN-Q3MTC-500
E5AN-Q3MP-500
Yes
E5AN-Q3HMTC-500
E5AN-Q3HMP-500
Current
No
E5AN-C3MTC-500
E5AN-C3MP-500
Relay
No
E5AN-R3MTC-500
E5AN-R3MP-500
Yes
E5AN-R3HMTC-500
E5AN-R3HMP-500
Voltage
(for driving SSR)
No
E5AN-Q3MTC-500
E5AN-Q3MP-500
Yes
E5AN-Q3HMTC-500
E5AN-Q3HMP-500
Current
No
E5AN-C3MTC-500
E5AN-C3MP-500
Note 1. A Current Transformer (CT) is not provided with the Unit. If using a heater burnout alarm, be sure to order one when ordering the E5AN.
2. When the heating and cooling function or the heater burnout alarm is used, one of the alarm outputs will be disabled for each function used.
3. Specify the power supply specifications when ordering.
Digital Temperature Controllers
E5AN
I-11
■ Option Units
The E5AN provides communication or event input functionality when
mounted with one of the following Option Units.
Name
Model
Function
Communication Unit
E53-AK01
RS-232C communication
E53-AK03
RS-485 communication
Event Input Unit
E53-AKB
Event input
■ Current Transformer (Sold
Separately)
Model
E54-CT1
E54-CT3
Hole diameter
5.8 dia.
12.0 dia.
■ Terminal Cover
E53-COV11
Model
Note: The Terminal Cover comes with the E5AN and does not have
to be purchased separately.
Specifications
■ Ratings
Supply voltage
100 to 240 VAC, 50/60 Hz
Operating voltage range
85% to 110% of rated supply voltage
Power consumption
9 VA
Sensor input
Thermocouple:
Platinum resistance thermometer:
Infrared temperature sensor:
Voltage input:
Control output
24 VAC, 50/60 Hz/24 VDC
5 VA/4 W
K, J, T, E, L, U, N, R, S, B
Pt100, JPt100
10 to 70°C, 60 to 120°C, 115 to 165°C, 160 to 260°C
0 to 50 mV
Relay output
SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations
Voltage output
12 VDC +15%/−20% (PNP), max. load current: 40 mA, with short-circuit protection circuit
Current output
4 to 20 mA DC, load: 600 Ω max., resolution: approx. 2,600
Alarm output
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations
Control method
2-PID or ON/OFF control
Setting method
Digital setting using front panel keys
Indication method
7-segment digital display and single-lighting indicator
Character height: PV: 15.0 mm; SV: 9.5 mm
Other functions
According to Controller model
Ambient temperature
−10 to 55°C (with no condensation or icing)
Ambient humidity
25% to 85%
Storage temperature
−25 to 65°C (with no condensation or icing)
I-12
Digital Temperature Controllers E5AN
■ Input Ranges
Platinum Resistance Thermometer Input/Thermocouple Input
Platinum resistance thermometer input
Input type
Platinum resistance thermometer
Temperature range
Name
1800
1700
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
−100
−200
Set value
Pt100
JPt100
850
500.0
−200
−199.9
0
1
500.0
100.0
100.0
0.0
0.0
−199.9
2
3
4
Thermocouple input
Input type
Set value
K
J
T
E
L
U
N
R
S
B
K10 to
70°C
Analog input
K60 to K115 to K160 to
120°C 165°C 260°C
1800
1700
1300
1300
850
0 to 50 mV
Usable in the
following
ranges by
scaling:
−1999 to 9999
or −199.9 to
999.9
1700
850
600
Temperature
Controller
Temperature range
Name
1800
1700
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
−100
−200
ES1A Infrared
Temperature Sensor
Thermocouple
500.0
400.0
400
400.0
400
400.0
260
120
165
0
0
0
0
12
13
14
15
70
100
−20.0
−20.0
0
−100
−200
−200
0
1
2
3
4
−100
−199.9
17
5
6
−200
−199.9
7
18
0
0
9
10
−200
8
11
16
Applicable standards by input type are as follows:
K, J, T, E, N, R, S, B: JIS C1602-1995
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985
JPt100: JIS C1604-1989, JIS C1606-1989
Pt100: JIS C1604-1997, IEC751
Shaded ranges indicate default settings.
ES1A models with a temperature range of 160°C to 260°C have been discontinued.
Digital Temperature Controllers
E5AN
I-13
■ Characteristics
Indication accuracy
Thermocouple:
(±0.5% of indicated value or ±1°C, whichever greater) ±1 digit max. (see note)
Platinum resistance thermometer:
(±0.5% of indicated value or ±1°C, whichever greater) ±1 digit max.
Analog input: ±0.5% FS±1 digit max.
CT input: ±5% FS±1 digit max.
Hysteresis
0.1 to 999.9 EU (in units of 0.1 EU)
Proportional band (P)
0.1 to 999.9 EU (in units of 0.1 EU)
Integral time (I)
0 to 3999 s (in units of 1 s)
Derivative time (D)
0 to 3999 s (in units of 1 s)
Control period
1 to 99 s (in units of 1 s)
Manual reset value
0.0% to 100.0% (in units of 0.1%)
Alarm setting range
−1999 to 9999 (decimal point position depends on input type)
Sampling period
500 ms
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
2000 VAC, 50 or 60 Hz for 1min (between different charging terminals)
Vibration resistance
10 to 55 Hz, 10 m/s2 for 2 hours each in X, Y and Z directions
Shock resistance
300 m/s2, 3 times each in 3 axes, 6 directions (relay: 100 m/s2)
Weight
Approx. 310 g
Degree of protection
Front panel: NEMA4X for indoor use (equivalent to IP66), rear case: IP20, terminals: IP00
Memory protection
EEPROM (non-volatile memory) (number of writes: 100,000)
EMC
Emission Enclosure:
Emission AC Mains:
Immunity ESD:
Approved standards
UL3121-1, CSA22.2 No. 142, E.B.1402C
Conforms to EN50081-2, EN50082-2, EN61010-1 (IEC61010-1)
Conforms to VDE0106/part 100 (Finger Protection), when the terminal cover is mounted.
Mounting bracket: Approx. 60 g
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:
ENV50140:
10 V/m (amplitude modulated, 80 MHz to
1 GHz) (level 3)
10 V/m (pulse modulated, 900 MHz)
Immunity Conducted Disturbance: ENV50141:
10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
EN61000-4-4: 2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Note: The indication of K thermocouples in the −200 to 1300°C range, and T and N thermocouples at a temperature of −100°C or less, and U and
L thermocouples at any temperature is ±2°C±1 digit maximum. The indication of B thermocouples at a temperature of 400°C or less is unrestricted.
The indication of R and S thermocouples at a temperature of 200°C or less is ±3°C±1 digit maximum.
■ Communications Specifications
Transmission path connection
RS-485:
Multiple points
RS-232C: Point-to-point
Communications method (see note 1)
RS-485 (two-wire, half duplex)/RS-232C
Synchronization method
Start-stop synchronization
Baud rate
1,200/2,400/4,800/9,600/19,200 bps
Transmission code
ASCII
Data bit length (see note 2)
7 or 8 bits
Stop bit length (see note 2)
1 or 2 bits
Error detection
Vertical parity (none, even, odd)
Frame check sequence (FCS): with SYSWAY
Block check character (BCC): with CompoWay/F
Flow control
Not available
Interface (see note 1)
RS-485/RS-232C
Retry function
Not available
Communications buffer
40 bytes
Note 1. RS-232C communications are only supported for the E5AN and E5EN models.
2. The baud rate, data bit length, stop bit length, or vertical parity can be individually set using the communications setting level.
I-14
Digital Temperature Controllers E5AN
■ Current Transformer (Sold Separately) Ratings
Dielectric strength
1,000 VAC (1 min)
Vibration resistance
50 Hz 98 m/s2
Weight
E54-CT1: Approx. 11.5 g
E54-CT3: Approx. 50 g
Accessories (E54-CT3 only)
Armature (2)
Plug (2)
■ Heater Burnout Alarm Specifications
Max. heater current
Single-phase AC: 50 A (see note 1)
Input current readout accuracy
±5%FS±1 digit max.
Heater burnout alarm setting range
0.0 to 50.0 A (0.1 A units) (see note 2)
Min. detection ON time
190 ms (see note 3)
Note 1. When heater burnout is detected on a 3-phase heater, use the K2CU-F@@A-@GS (with gate input terminal).
2. When the set value is “00 A,” the heater burnout alarm will always be OFF. When the set value is “50.0 A,” the heater burnout alarm will
always be ON.
3. When the control output ON time is less than 190 ms, heater burnout detection and heater current measurement will not be carried out.
■ Engineering Data
Electrical Life Expectancy Curve for Relays (Reference Values)
Life expectancy (×104 operations)
500
300
E5AN, E5EN
250 VAC, 30 VDC
(resistive load)
cosφ = 1
100
50
30
10
5
E5CN
250 VAC, 30 VDC
(resistive load)
cosφ = 1
3
1
0
1
2
3
4
5
6
Temperature
Controller
Switching current (A)
E54-CT1
Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)
Output voltage (Eo) V (r.m.s.)
Maximum continuous heater current: 50 A (50/60 Hz)
Number of windings: 400±2
Winding resistance: 18±2 Ω
100 V 50 Hz
∞
1 kΩ
10
Distortion
factor 10%
1
3%
1%
100 mV
100 Ω
10
RL = 10 Ω
1
100 µV
10
1
10
100 mA
1
10
100 1,000 A
Thru-current (Io) A (r.m.s.)
Digital Temperature Controllers
E5AN
I-15
E54-CT3
Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)
Output voltage (Eo) V (r.m.s.)
Maximum continuous heater current: 120 A (50/60 Hz)
(Maximum continuous heater current for an OMRON Temperature Controller is 50 A.)
Number of windings: 400±2
Winding resistance: 8±0.8 Ω
100 V 50 Hz
∞
1 kΩ
500 Ω
10
Distortion
factor 10%
3%
1%
1
100 mV
100 Ω
50 Ω
10
RL = 10 Ω
1
100 µV
10
1
10
100 mA
1
10
100 1,000 A
Thru-current (Io) A (r.m.s.)
Wiring Terminals
• The voltage output (control output) is not electrically insulated from
the internal circuits. When using a grounding thermocouple, do not
connect the control output terminals to the ground. If the control
output terminals are connected to the ground, errors will occur in
the measured temperature values as a result of leakage current.
• Standard insulation is applied to the power supply I/O sections. If
reinforced insulation is required, connect the input and output terminals to a device without any exposed current-carrying parts or to
a device with standard insulation suitable for the maximum operating voltage of the power supply I/O section.
Event input
Contact inputs
Current output
Voltage output
4 DC to 20 mA
12 VDC
40 mA
Relay output
Communications
Non-contact input
Input power supply
Control output 1
Heater burnout
detection input
ALM3/Control
output 2
Alarm output
ALM2
ALM1/Heater
burnout
Note: Two input power supplies are available: 100 to 240 VAC or 24 VDC.
I-16
Digital Temperature Controllers E5AN
Analog input
RS-232C
RS-485
11 ←SD
11 ←B (+)
12 ←RD
12 ←A (−)
13 ←SG
13 ←Do not use
Nomenclature
Temperature
unit
Operation
indicators
No.1 display
No.2 display
Up key
Level key
Down key
Mode key
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Panel Cutouts
Group Mounted
(96 × number of units -3.5) +1.0
0
Temperature
Controller
120 min.
Mounted Separately
Group mounting does
not allow waterproofing.
• Recommended panel thickness is 1 to 8 mm.
• Group mounting is not possible in the vertical
direction. (Maintain the specified mounting
space between Controllers when they are
group mounted.)
• To mount the E5AN so that it is waterproof,
apply the waterproof packing to the E5AN.
• When two or more E5ANs are mounted, make
sure that the surrounding temperature does
not exceed the allowable operating
temperature specified in the specifications.
Digital Temperature Controllers
E5AN
I-17
Current Transformer (Sold Separately)
Terminal Cover
E54-CT1
E53-COV11
E54-CT3
2.36 dia.
5.8 dia.
6.5 dia.
92.3
40 x 40
Two, 3.5 dia.
13
12 dia.
Two, M3 (depth: 4)
6.5
10.5
8
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
I-18
Digital Temperature Controllers E5AN