EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown PRODUCT FEATURES Datasheet General Description Features The EMC2113 is an SMBus compliant fan controller. The fan driver can be operated using two methods, each with two modes. The methods include an RPM-based Fan Speed Control Algorithm and a direct PWM drive setting. The modes include manually programming the desired settings or using the internal programmable temperature look-up table to select the desired setting based on measured temperature. — 4-wire fan compatible — Both Low and High frequency PWM The device includes high and low limits for all temperature channels as well as a hardware set critical temperature limit. This hardware set limit drives a dedicated system shutdown pin. Up to Three External Temperature Channels — — — — — Supports transistor model for 90nm - 45nm Intel CPUs Resistance Error Correction and Beta Compensation 1°C accurate (60°C to 125°C) 0.125°C resolution Programmable High and Low limits Hardware Programmable Thermal Shutdown Temperature — Cannot be altered by software — 65°C to 127°C Range — Dedicated system shutdown interrupt pin Finally, the device includes an open-drain, active low interrupt pin to flag temperature or fan control errors. Notebook Computers Projectors Graphics Cards Industrial and Networking Equipment Temperature Look-Up Table — Controls fan speed or PWM drive setting — Eight steps that incorporate up to four temperature zones simultaneously (user selectable) — Supports forced DTS or standard temperature data — Allows external PWM input (150Hz to 40kHz) RPM-based fan control algorithm — 2% accurate from 500 RPM to 16k RPM — Automatic Tachometer feedback The EMC2113 includes a temperature monitor that measures up to three (3) external diodes and the internal diode. The temperature monitors offer 1°C accuracy (for external diodes) with sophisticated features to reduce errors introduced by series resistance and beta variation of substrate thermal diode transistors commonly found in processors. Applications Programmable Fan Control circuit Internal Temperature Monitor — ±1°C accuracy — 0.125°C resolution 3.3V Supply Voltage Open drain interrupt pin SMBus 2.0 Interface — SMBus Alert compatible — Selectable SMBus Address via pull-up resistor and ADDR_SEL pin — Block Read and Write SMSC EMC2113 Available in 16-pin 4mm x 4mm QFN Lead-free RoHS Compliant package DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet ORDERING INFORMATION: ORDERING NUMBER EMC2113-1-AP-TR PACKAGE 16-pin 4mm x4mm QFN (Lead-free ROHS Compliant) FEATURES RPM-based Fan Speed Control Algorithm, High Frequency PWM driver, HW Thermal / Critical shutdown This product meets the halogen maximum concentration values per IEC61249-2-21 For RoHS compliance and environmental information, please visit www.smsc.com/rohs 80 ARKAY DRIVE, HAUPPAUGE, NY 11788 (631) 435-6000, FAX (631) 273-3123 Copyright © 2009 SMSC or its subsidiaries. All rights reserved. Circuit diagrams and other information relating to SMSC products are included as a means of illustrating typical applications. Consequently, complete information sufficient for construction purposes is not necessarily given. Although the information has been checked and is believed to be accurate, no responsibility is assumed for inaccuracies. SMSC reserves the right to make changes to specifications and product descriptions at any time without notice. Contact your local SMSC sales office to obtain the latest specifications before placing your product order. The provision of this information does not convey to the purchaser of the described semiconductor devices any licenses under any patent rights or other intellectual property rights of SMSC or others. All sales are expressly conditional on your agreement to the terms and conditions of the most recently dated version of SMSC's standard Terms of Sale Agreement dated before the date of your order (the "Terms of Sale Agreement"). The product may contain design defects or errors known as anomalies which may cause the product's functions to deviate from published specifications. Anomaly sheets are available upon request. SMSC products are not designed, intended, authorized or warranted for use in any life support or other application where product failure could cause or contribute to personal injury or severe property damage. Any and all such uses without prior written approval of an Officer of SMSC and further testing and/or modification will be fully at the risk of the customer. Copies of this document or other SMSC literature, as well as the Terms of Sale Agreement, may be obtained by visiting SMSC’s website at http://www.smsc.com. SMSC is a registered trademark of Standard Microsystems Corporation (“SMSC”). Product names and company names are the trademarks of their respective holders. SMSC DISCLAIMS AND EXCLUDES ANY AND ALL WARRANTIES, INCLUDING WITHOUT LIMITATION ANY AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND AGAINST INFRINGEMENT AND THE LIKE, AND ANY AND ALL WARRANTIES ARISING FROM ANY COURSE OF DEALING OR USAGE OF TRADE. IN NO EVENT SHALL SMSC BE LIABLE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES; OR FOR LOST DATA, PROFITS, SAVINGS OR REVENUES OF ANY KIND; REGARDLESS OF THE FORM OF ACTION, WHETHER BASED ON CONTRACT; TORT; NEGLIGENCE OF SMSC OR OTHERS; STRICT LIABILITY; BREACH OF WARRANTY; OR OTHERWISE; WHETHER OR NOT ANY REMEDY OF BUYER IS HELD TO HAVE FAILED OF ITS ESSENTIAL PURPOSE, AND WHETHER OR NOT SMSC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Revision 1.2 (10-08-09) 2 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table of Contents Chapter 1 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Chapter 2 Delta from EMC2103. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Chapter 3 Pin Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Chapter 4 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 4.1 4.2 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 SMBus Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Chapter 5 SMBus Slave Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.1 5.2 System Management Bus Interface Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.1 SMBus Start Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.2 SMBus Address and RD / WR Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.3 SMBus Data Bytes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.4 SMBus ACK and NACK Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.5 SMBus Stop Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.6 SMBus Time-out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.7 SMBus and I2C Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SMBus Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.1 Write Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.2 Read Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.3 Send Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.4 Receive Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.5 Block Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.6 Block Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.7 Alert Response Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 17 17 18 18 18 18 18 18 19 19 19 20 20 20 21 Chapter 6 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 6.10 6.11 6.12 Critical/Thermal Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1.1 SYS_SHDN Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1.2 SHDN_SEL Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1.3 TRIP_SET Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Control Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PWM Fan Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Control Look-Up Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.4.1 Programming the Look Up Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.4.2 DTS Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PWM Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RPM-Based Fan Speed Control Algorithm (FSC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.6.1 Programming the RPM-Based Fan Speed Control Algorithm . . . . . . . . . . . . . . . . . . . . . Tachometer Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.7.1 Stalled Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.7.2 Aging Fan or Invalid Drive Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spin Up Routine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ramp Rate Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Watchdog Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.10.1 Power Up Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.10.2 Continuous Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fault Queue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ALERT Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SMSC EMC2113 3 DATASHEET 23 23 24 24 26 27 27 29 29 29 30 30 30 31 31 31 32 33 33 34 34 34 Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 6.13 6.14 Temperature Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.13.1 Dynamic Averaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.13.2 Resistance Error Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.13.3 Beta Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.13.4 Ideality Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.13.5 Digital Averaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diode Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.14.1 Anti-Parallel Diodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.14.2 Diode Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 34 35 35 35 35 35 36 36 Chapter 7 Fan Control Register Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 7.10 7.11 7.12 7.13 7.14 7.15 7.16 7.17 7.18 7.19 7.20 7.21 7.22 7.23 7.24 7.25 7.26 7.27 7.28 7.29 7.30 7.31 7.32 7.33 7.34 7.35 7.36 7.37 7.38 7.39 7.40 Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1.1 Lock Entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature Data Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Critical/Thermal Shutdown Temperature Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pushed Temperature Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PWM Input Duty Cycle Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TRIP_SET Voltage Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ideality Factor Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Beta Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REC Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Critical Temperature Limit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration 2 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Status Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Status Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.14.1 Tcrit Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Enable Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Interrupt Enable Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PWM Driver Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PWM Driver Base Frequency Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Limit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PWM Input Duty Cycle High Limit Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Setting Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PWM Divide Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Configuration 1 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Configuration 2 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gain Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Spin Up Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Step Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Minimum Drive Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Valid TACH Count Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Drive Fail Band Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TACH Target Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TACH Reading Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Look Up Table Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Look Up Table Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Software Lock Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Features Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manufacturer ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revision Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revision 1.2 (10-08-09) 4 DATASHEET 37 43 44 45 45 46 46 46 48 49 50 50 51 53 53 54 54 54 55 56 56 57 57 58 58 58 60 62 62 64 64 65 65 66 66 67 68 70 70 71 72 72 SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Chapter 8 Typical Operating Curves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Chapter 9 Package Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 9.1 9.2 EMC2113 Package Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Package Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Appendix A Look Up Table Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 A.1 A.2 A.3 Example #1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.1.1 LUT Configuration Bit Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Example #2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.2.1 Fan Spin Up Configuration Bit Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.2.2 LUT Configuration - Bit Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Example #3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.3.1 LUT COnfiguration Bit Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SMSC EMC2113 5 DATASHEET 80 81 82 82 83 84 84 Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table of Figures Figure 1.1 Figure 3.1 Figure 5.1 Figure 6.1 Figure 6.2 Figure 6.3 Figure 6.4 Figure 6.5 Figure 6.6 Figure 9.1 Figure 9.2 Figure 9.3 Figure 9.4 EMC2113 Block Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 EMC2113-1 Pin Diagram (16-Pin QFN). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 SMBus Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 System Diagram for EMC2113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Block Diagram of Critical/Thermal Shutdown. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Fan Control Look-Up Table Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Spin Up Routine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Ramp Rate Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Diode Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 16-Pin QFN 4mm x 4mm Package Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 16-Pin QFN 4mm x 4mm PCB Footprint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 16-Pin QFN 4mm x 4mm Package Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 EMC2113 Package Markings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Revision 1.2 (10-08-09) 6 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet List of Tables Table 2.1 LUT Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 3.1 Pin Description for EMC2113-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 3.2 Pin Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 4.1 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 4.2 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 4.3 SMBus Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.1 ADDR_SEL Pin Decode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.2 Protocol Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.3 Write Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.4 Read Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.5 Send Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.6 Receive Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.7 Block Write Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.8 Block Read Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.9 Alert Response Address Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.1 SHDN_SEL Pin Decode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.2 TRIP_SET Resistor Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.3 Fan Controls Active for Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.4 Dynamic Averaging Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.1 EMC2113 Register Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.2 Temperature Data Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.3 Temperature Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.4 Critical/Thermal Shutdown Temperature Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.5 Critical/Thermal Shutdown Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.6 Pushed Temperature Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.7 PWM Duty Cycle Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.8 TRIP_SET Voltage Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.9 Ideality Factor Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.10 Ideality Factor Look-Up Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.11 Substrate Diode Ideality Factor Look-Up Table (BJT Model) . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.12 Beta Configuration Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.13 Beta Compensation Look Up Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.14 REC Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.15 Limit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.16 Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.17 Configuration 2 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.18 Fault Queue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.19 Conversion Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.20 Interrupt Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.21 Error Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.22 Fan Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.23 Interrupt Enable Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.24 Fan Interrupt Enable Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.25 PWM Driver Configuration Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.26 PWM Driver Base Frequency Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.27 PWM_BASEx[1:0] it Decode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.28 Limit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.29 PWM Duty Cycle High Limit Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.30 Fan Driver Setting Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.31 PWM Divide Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.32 Fan Configuration 1 Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.33 Range Decode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.34 Minimum Edges for Fan Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SMSC EMC2113 7 DATASHEET 10 11 12 13 14 15 17 19 19 19 19 20 20 20 21 24 25 27 34 37 44 44 45 45 45 46 46 46 47 47 48 48 49 50 50 51 52 52 53 53 54 54 55 56 56 56 57 57 58 58 58 59 59 Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.35 Update Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.36 Fan Configuration 2 Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.37 Derivative Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.38 Error Range Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.39 Gain Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.40 Gain Decode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.41 Fan Spin Up Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.42 DRIVE_FAIL_CNT[1:0] Bit Decode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.43 Spin Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.44 Spin Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.45 Fan Step Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.46 Minimum Fan Drive Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.47 Valid TACH Count Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.48 Fan Drive Fail Band Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.49 TACH Target Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.50 TACH Reading Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.51 Look Up Table Configuration Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.52 Look Up Table Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.53 Software Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.54 Product Features Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.55 ADDR_SEL[2:0] Encoding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.56 SHDN_SEL[2:0] Encoding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.57 Product ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.58 Manufacturer ID Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.59 Revision Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table A.1 Look Up Table Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table A.2 Look Up Table Example #1 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table A.3 Fan Speed Control Table Example #1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table A.4 Fan Speed Determination for Example #1 (using settings in Table A.3) . . . . . . . . . . . . . . . . . Table A.5 Look Up Table Example #2 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table A.6 Fan Speed Control Table Example #2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table A.7 Fan Speed Determination for Example #2 (using settings in Table A.6) . . . . . . . . . . . . . . . . . Table A.8 Look Up Table Example #3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table A.9 Fan Speed Control Table Example #3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table A.10 Fan Speed Determination for Example #2 (using settings in Table A.9) . . . . . . . . . . . . . . . . . Revision 1.2 (10-08-09) 8 DATASHEET 60 60 61 61 62 62 62 62 63 64 64 64 65 65 66 66 67 68 70 70 70 71 71 72 72 80 81 81 82 82 83 84 84 85 85 SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet GND Thermal Shutdown Logic External Temp Diodes Antiparallel Diode VDD SHDN_SEL TRIP_SET DP1 DN1 DP2/DN3 DN2/DP3 SYS_SHDN Chapter 1 Block Diagram Analog Mux Temp Limit Registers 11 bit Σ Δ ADC Temp Registers Internal Temp Diode ADDR_SEL SMBus Slave Interface SMCLK SMDATA ALERT Configuration PWM TACH PWM driver Lookup Table / RPM Control Tach PWM Detect PWM_IN Figure 1.1 EMC2113 Block Diagram SMSC EMC2113 9 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Chapter 2 Delta from EMC2103 The EMC2113 is compatible with the EMC2103-2 with the following changes: Removed two GPIOs - Pins 4 and 5 of the EMC2103-2 were GPIO pins. These have been removed. Added PWM Input functionality - This functionality allows the user to drive a PWM input into the EMC2113. The duty cycle of the PWM represents a temperature value and can be used as an input to the Fan Control Look Up Table. Added ADDR_SEL functionality - This functionality allows the user to choose one of six SMBus address options. Updated Hysteresis within Look Up Table - The Fan Control Look Up Table in the EMC2113 allows the user to program a different hysteresis value to apply to each temperature input channel instead of a single hysteresis value that applies to all temperature input channels. Updated input muxing for the Look Up Table - The Fan Control Look Up Table has more options over which temperature channel is used for fan control. Updated HW set shutdown functionality to include option for Internal diode Added control to disable Ramp Rate control if one or more temperatures exceed the high limit Added SMBus Block Read and Write capability Table 2.1 LUT Options TEMPERATURE INPUT EMC2113 OPTIONS Temperature Column 1 External Diode 1 -or- Pushed Temperature 1 Temperature Column 2 External Diode 2 Temperature Column 3 External Diode 3 -or- Pushed Temperature 1 Temperature Column 4 Internal Diode -or- Pushed Temperature 2 Revision 1.2 (10-08-09) 10 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet VDD 3 PWM_IN 4 14 TRIP_SET 13 SHDN_SEL 11 PWM EMC2113 16-pin QFN 10 TACH 9 ADDR_SEL SMCLK SMDATA 8 2 SYS_SHDN 7 DP1 12 GND ALERT 6 1 5 DN1 15 DN2 / DP3 16 DP2 / DN3 Chapter 3 Pin Layout Figure 3.1 EMC2113-1 Pin Diagram (16-Pin QFN) Table 3.1 Pin Description for EMC2113-1 PIN NUMBER PIN NAME PIN FUNCTION PIN TYPE 1 DN1 Negative (cathode) analog input for External Diode 1 AIO 2 DP1 Positive (anode) analog input for External Diode 1 AIO 3 VDD Power Supply Power 4 PWM_IN PWM input signal from host DI (5V) 5 ADDR_SEL Address Select Input AIO 6 ALERT Active low SMBus slave interrupt - requires external pull-up resistor. OD (5V) 7 SYS_SHDN Active low Critical/Thermal Shutdown output requires external pull-up resistor OD (5V) SMSC EMC2113 11 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 3.1 Pin Description for EMC2113-1 (continued) PIN NUMBER PIN NAME PIN FUNCTION PIN TYPE 8 SMDATA SMBus data input/output - requires external pull-up resistor DIOD (5V) 9 SMCLK SMBus clock input - requires external pull-up resistor DI (5V) 10 TACH Tachometer input for the Fan DI (5V) PWM - Open Drain PWM drive output for the Fan (default) OD (5V) PWM - Push Pull PWM drive output for the fan DO 11 PWM 12 GND Ground Power 13 SHDN_SEL Selects the hardware shutdown channel and operating mode AIO 14 TRIP_SET Voltage input to set the Critical/Thermal Shutdown threshold AIO DN2 - Negative (cathode) connection for External Diode 2 AIO DP3 - Positive (anode) connection for External Diode 3 AIO DP2 - Positive (anode connection for External Diode 2 AIO DN3 - Negative (cathode) connection for External Diode 3 AIO 15 DN2 / DP3 16 DP2 / DN3 The pin types are described in detail below. All pins labelled with (5V) are 5V tolerant. Note: For all 5V tolerant pins that require a pull-up resistor, the pull-up voltage cannot exceed 3.6V when the device is unpowered. Table 3.2 Pin Types PIN TYPE Power DI DESCRIPTION This pin is used to supply power or ground to the device. Digital Input - this pin is used as a digital input. This pin is 5V tolerant. AIO Analog Input / Output - this pin is used as an I/O for analog signals. DO Push / Pull Digital Output - this pin is used as a digital output. It can both source and sink current. DIO Digital Input / Output this pin is used as a digital I/O. It can both source and sink current. OD Open Drain Digital Output - this pin is used as a digital output. It is open drain and requires a pull-up resistor. This pin is 5V tolerant. Revision 1.2 (10-08-09) 12 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Chapter 4 Electrical Characteristics Table 4.1 Absolute Maximum Ratings Voltage on 5V tolerant pins (VPULLUP) -0.3 to 5.5 V Voltage on 5V tolerant pins (|VPULLUP - VDD|) See Note 4.1 0 to 3.6 V Voltage on VDD pin -0.3 to 4 V Voltage on any other pin to GND -0.3 to VDD + 0.3 V Package Power Dissipation 0.8W up to TA = 85°C W Junction to Ambient (θJA) 50 °C/W Operating Ambient Temperature Range -40 to 125 °C Storage Temperature Range -55 to 150 °C ESD Rating, All Pins, HBM 2000 V Note: Stresses above those listed could cause permanent damage to the device. This is a stress rating only and functional operation of the device at any other condition above those indicated in the operation sections of this specification is not implied. When powering this device from laboratory or system power supplies, it is important that the Absolute Maximum Ratings not be exceeded or device failure can result. Some power supplies exhibit voltage spikes on their outputs when the AC power is switched on or off. In addition, voltage transients on the AC power line may appear on the DC output. If this possibility exists, it is suggested that a clamp circuit be used. Note: All voltages are relative to ground. Note: θJA numbers are based on a recommended four 12 mil vias connecting the thermal pad to PCB ground. Note 4.1 SMSC EMC2113 For the 5V tolerant pins that have a pull-up resistor, the pull-up voltage must not exceed 3.6V when the EMC2113 is unpowered. 13 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 4.1 Electrical Specifications Table 4.2 Electrical Specifications VDD = 3V to 3.6V, TA = -40°C to 125°C, all Typical values at TA = 27°C unless otherwise noted. CHARACTERISTIC SYMBOL MIN TYP MAX UNIT CONDITIONS DC Power Supply Voltage Supply Current VDD 3 3.3 3.6 V 1.1 1.5 mA 4 Conversions/second, Fan Driver active at maximum PWM frequency, Dynamic Averaging Enabled 0.7 1.1 mA 1 Conversion/second, Fan Driver not active, Dynamic Averaging Disabled IDD First Conversion Ready tCONV_T 150 300 ms Time after power up before all channels updated SMBus Delay tSMB_D 10 15 ms Time before SMBus communications should be sent by host External Temperature Monitors Temperature Accuracy Temperature Resolution ±0.5 ±1 °C 60°C < TDIODE < 125°C 30°C < TA < 100°C ±1 ±2 °C -40°C < TDIODE < 125°C 0.125 Diode decoupling capacitor CFILTER 2200 Resistance Error Corrected RSERIES 100 °C 2700 pF Connected across external diode, CPU, GPU, or AMD diode Ohm Sum of series resistance in both DP and DN lines Internal Temperature Monitor Temperature Accuracy TA Temperature Resolution ±0.5 ±1 °C ±1 ±2 °C 0.125 40°C < TA < 100°C °C RPM-Based Fan Controller Tachometer Range TACH RPM Control Accuracy ΔTACH 480 ±1 16000 RPM ±2 % PWM Fan Driver PWM Resolution PWM PWM Duty Cycle DUTY Revision 1.2 (10-08-09) 256 0 Steps 100 14 DATASHEET % SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 4.2 Electrical Specifications (continued) VDD = 3V to 3.6V, TA = -40°C to 125°C, all Typical values at TA = 27°C unless otherwise noted. CHARACTERISTIC SYMBOL MIN TYP MAX UNIT CONDITIONS PWM Input Detection PWM Frequency fPWM_IN 150 40k Hz TRIP_SET Measurement TRIP_SET Decode Accuracy VTRIP ±0.5 ±1 °C TRIP_SET Decode Accuracy VTRIP ±1 ±2 °C 1% resistor connected to ground 5% resistor connected to ground Digital I/O pins Input High Voltage VIH Input Low Voltage VIL Output High Voltage VOH Output Low Voltage VOL 0.4 V 8 mA current sink Leakage Current ILEAK ±5 uA ALERT and SYS_SHDN pins Device powered or unpowered TA < 85°C 4.2 2.0 V 0.8 V VDD 0.4 8 mA current drive V SMBus Electrical Specifications Table 4.3 SMBus Electrical Specifications VDD= 3V to 3.6V, TA = -40°C to 125°C Typical values are at TA = 27°C unless otherwise noted. CHARACTERISTIC SYMBOL MIN TYP MAX UNITS CONDITIONS SMBus Interface Input High/Low Current Input Capacitance IIH / IIL CIN 4 ±5 uA 10 pF Device powered or unpowered TA < 85°C SMBus Timing Clock Frequency fSMB 10 400 kHz 50 ns Spike Suppression tSP Bus free time Start to Stop tBUF 1.3 us Setup Time: Start tSU:STA 0.6 us Setup Time: Stop tSU:STP 0.6 us Data Hold Time tHD:DAT 0.6 6 us Data Setup Time tSU:DAT 0.6 72 us SMSC EMC2113 15 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 4.3 SMBus Electrical Specifications (continued) VDD= 3V to 3.6V, TA = -40°C to 125°C Typical values are at TA = 27°C unless otherwise noted. CHARACTERISTIC SYMBOL MIN Clock Low Period tLOW 1.3 us Clock High Period tHIGH 0.6 us Clock/Data Fall time tFALL 300 ns Min = 20+0.1CLOAD ns Clock/Data Rise time tRISE 300 ns Min = 20+0.1CLOAD ns CLOAD 400 pF Total per bus line Capacitive Load Revision 1.2 (10-08-09) TYP MAX 16 DATASHEET UNITS CONDITIONS SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Chapter 5 SMBus Slave Interface The EMC2113 communicates with a host controller, such as an SMSC SIO, through the SMBus. The SMBus is a two-wire serial communication protocol between a computer host and its peripheral devices. 5.1 System Management Bus Interface Protocol The EMC2113 contains an SMBus slave interface. A detailed timing diagram is shown in Figure 5.1, "SMBus Timing Diagram". Stretching of the SMCLK signal is supported, however the EMC2113 will not stretch the clock signal. TLOW THIGH THD:STA TSU:STO TRISE SMCLK THD:STA TFALL THD:DAT TSU:STA TSU:DAT SMDATA TBUF P S S S - Start Condition P - Stop Condition P Figure 5.1 SMBus Timing Diagram 5.1.1 SMBus Start Bit The SMBus Start bit is defined as a transition of the SMBus Data line from a logic ‘1’ state to a logic ‘0’ state while the SMBus Clock line is in a logic ‘1’ state. 5.1.2 SMBus Address and RD / WR Bit The SMBus Address Byte consists of the 7-bit slave address followed by the RD / WR indicator bit. If this RD / WR bit is a logic ‘0’, then the host device is writing data to the slave device. If this RD / WR bit is a logic ‘1’, then the host device is reading data from the slave device. The EMC2113 SMBus slave address is determined via the pull-up resistor connected to the ADDR_SEL pin as shown Table 5.1, "ADDR_SEL Pin Decode". Table 5.1 ADDR_SEL Pin Decode SMSC EMC2113 PULL-UP RESISTOR VALUE FAN CONTROL ADDRESS 4.7k Ohm ±5% 0101_100(r/w) 6.8k Ohm ±5% 0101_101(r/w) 10k Ohm ±5% 0101_110(r/w) 15k Ohm ±5% 1001_100(r/w) 17 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 5.1 ADDR_SEL Pin Decode (continued) 5.1.3 PULL-UP RESISTOR VALUE FAN CONTROL ADDRESS 22k Ohm ±5% 1001_101(r/w) 33k Ohm ±5% 1001_000(r/w) SMBus Data Bytes All SMBus Data bytes are sent most significant bit first and composed of 8-bits of information. 5.1.4 SMBus ACK and NACK Bits The SMBus slave will acknowledge all data bytes that it receives. This is done by the slave device pulling the SMBus Data line low after the 8th bit of each byte that is transmitted. The Host will NACK (not acknowledge) the last data byte to be received from the slave by holding the SMBus data line high after the 8th data bit has been sent. 5.1.5 SMBus Stop Bit The SMBus Stop bit is defined as a transition of the SMBus Data line from a logic ‘0’ state to a logic ‘1’ state while the SMBus clock line is in a logic ‘1’ state. When the EMC2113 detects an SMBus Stop bit, and it has been communicating with the SMBus protocol, it will reset its slave interface and prepare to receive further communications. 5.1.6 SMBus Time-out The EMC2113 includes an SMBus time-out feature. Following a 30ms period of inactivity on the SMBus, the device will time-out and reset the SMBus interface. The SMBus timeout defaults to enabled and can be disabled by setting the DIS_TO bit (see Section 7.12, "Configuration 2 Register"). 5.1.7 SMBus and I2C Compliance The major difference between SMBus and I2C devices is highlighted here. For complete compliance information refer to the SMBus 2.0 specification. 1. Minimum frequency for SMBus communications is 10kHz. 2. The slave protocol will reset if the clock is held low longer than 30ms. 3. The slave protocol will reset if both the clock and the data line are high for longer than 150us (idle condition). 4. I2C devices do not support the Alert Response Address functionality (which is optional for SMBus). 5.2 SMBus Protocols The EMC2113 slave interface is SMBus 2.0 compatible and support Send Byte, Read Byte, Receive Byte, Write Byte, Block Read Byte, Block Write Byte, and the Alert Response Address as valid protocols. These protocols are used as shown below. All of the below protocols use the convention in Table 5.2, "Protocol Format". For the Slave Address fields, the value of YYYY_YYY represents the programmed SMBus address. Revision 1.2 (10-08-09) 18 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 5.2 Protocol Format DATA SENT TO DEVICE DATA SENT TO THE HOST # of bits sent 5.2.1 # of bits sent Write Byte The Write Byte is used to write one byte of data to the registers as shown below Table 5.3. Table 5.3 Write Byte Protocol START SLAVE ADDRESS WR ACK REGISTER ADDRESS ACK REGISTER DATA ACK STOP 1 -> 0 YYYY_YYY 0 0 0 -> 1 0 XXh 0 0 -> 1 5.2.2 Read Byte The Read Byte protocol is used to read one byte of data from the registers as shown in Table 5.4. Table 5.4 Read Byte Protocol START SLAVE ADDRESS WR ACK REGISTER ADDRESS ACK START SLAVE ADDRESS RD ACK REGISTER DATA NACK STOP 1 -> 0 YYYY_YYY 0 0 XXh 0 1 -> 0 YYYY_YYY 1 0 XXh 1 0 -> 1 5.2.3 Send Byte The Send Byte protocol is used to set the internal address register pointer to the correct address location. No data is transferred during the Send Byte protocol as shown in Table 5.5. Table 5.5 Send Byte Protocol START SLAVE ADDRESS WR ACK REGISTER ADDRESS ACK STOP 1 -> 0 YYYY_YYY 0 0 XXh 1 0 -> 1 SMSC EMC2113 19 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 5.2.4 Receive Byte The Receive Byte protocol is used to read data from a register when the internal register address pointer is known to be at the right location (e.g. set via Send Byte). This is used for consecutive reads of the same register as shown in Table 5.6. Table 5.6 Receive Byte Protocol START SLAVE ADDRESS RD ACK REGISTER DATA NACK STOP 1 -> 0 YYYY_YYY 1 0 XXh 1 0 -> 1 5.2.5 Block Write The Block Write is used to write multiple data bytes to a group of contiguous registers as shown in Table 5.7. It is an extension of the Write Byte Protocol. Table 5.7 Block Write Protocol START SLAVE ADDRESS WR ACK REGISTER ADDRESS ACK REGISTER DATA ACK 1 ->0 YYYY_YYY 0 0 XXh 0 XXh 0 REGISTER DATA ACK REGISTER DATA ACK ... REGISTER DATA ACK STOP XXh 0 XXh 0 ... XXh 0 0 -> 1 5.2.6 Block Read The Block Read is used to read multiple data bytes from a group of contiguous registers as shown in Table 5.8. It is an extension of the Read Byte Protocol. Table 5.8 Block Read Protocol START SLAVE ADDRESS WR ACK REGISTER ADDRESS ACK START SLAVE ADDRESS RD ACK REGISTER DATA 1->0 YYYY_YYY 0 0 XXh 0 1 ->0 YYYY_YYY 1 0 XXh ACK REGISTER DATA ACK REGISTER DATA ACK REGISTER DATA ACK ... REGISTER DATA NACK STOP 0 XXh 0 XXh 0 XXh 0 ... XXh 1 0 -> 1 Revision 1.2 (10-08-09) 20 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 5.2.7 Alert Response Address The ALERT output can be used as a processor interrupt or as an SMBus Alert when configured to operate as an interrupt. When it detects that the ALERT pin is asserted, the host will send the Alert Response Address (ARA) to the general address of 0001_100b. All devices with active interrupts will respond with their slave address as shown in Table 5.9. Table 5.9 Alert Response Address Protocol START ALERT RESPONSE ADDRESS RD ACK DEVICE ADDRESS NACK STOP 1 -> 0 0001_100 1 0 YYYY_YYY 1 0 -> 1 The EMC2113 slave interface will respond to the ARA in the following way if the ALERT pin is asserted. 1. Send Slave Address and verify that full slave address was sent (i.e. the SMBus communication from the device was not prematurely stopped due to a bus contention event). 2. Set the MASK bit to clear the ALERT pin. SMSC EMC2113 21 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Chapter 6 Product Description The EMC2113 is an SMBus compliant fan controller with up to three (3) external and one (1) internal temperature channels. The fan driver can be operated using two methods, each with two modes. The methods include an RPM-based Fan Speed Control Algorithm and a direct PWM drive setting. The modes include manually programming the desired settings or using the internal programmable temperature look-up table to select the desired setting based on measured temperature. The temperature monitors offer 1°C accuracy (for external diodes) with sophisticated features to reduce errors introduced by series resistance and beta variation of substrate thermal diode transistors commonly found in processors (including support of the BJT or transistor model for a CPU diode). The EMC2113 allows the user to program temperatures generated from external sources to control the fan speed. This functionality also supports DTS data from the CPU. By pushing DTS or standard temperature values into dedicated registers, the external temperature readings can be used in conjunction with the external diode(s) and internal diode to control the fan speed. The EMC2113 also allows the user to input a PWM input signal on the PWM_IN pin that is used as an input to the Fan Speed Control Look Up Table. The EMC2113 includes a hardware programmable temperature limit and dedicated system shutdown output for thermal protection of critical circuitry. Figure 6.1 shows a system diagram of the EMC2113. VDD VDD ADDR_SEL VDD DP1 HOST DN1 SM CLK SM Bus In terfa ce SM DATA O ptio na l A n tipa ra llel D iod e E M C 21 1 3 DP2 / DN3 ALERT P W M _ IN DN2 / DP3 PW M 1 .5 V F a n D rive C ircu itry TACH VDD 1 .2k SYS_SHDN VDD T R IP _S E T GND SHDN _SEL Figure 6.1 System Diagram for EMC2113 Revision 1.2 (10-08-09) 22 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 6.1 Critical/Thermal Shutdown The EMC2113 provides a hardware Critical/Thermal Shutdown function for systems. Figure 6.2 is a block diagram of this Critical/Thermal Shutdown function. The Critical/Thermal Shutdown function accepts configuration information from the pullup resistor of the SHDN_SEL pin. The analog portion of the Critical/Thermal Shutdown function monitors the hardware determined shutdown channel. This measured temperature is then compared with TRIP_SET point. This TRIP_SET point is set by the system designer with a single external resistor. The SYS_SHDN is asserted when the indicated temperature meets or exceeds the temperature threshold (TTRIP) established by the TRIP_SET input pin for a number of consecutive measurements defined by the fault queue. Each of the software programmed temperature limits can be optionally configured to act as inputs to the Critical/Thermal Shutdown independent of the hardware shutdown operation. When configured to operate this way, the SYS_SHDN pin will be asserted when the temperature meets or exceeds the programmed Tcrit Limit for the enabled channel (see Section 7.10). Critical Shutdown Logic S/W Set Sensor Internal Temp S/W SHUTDOWN S/W Set Sensor External 1 Temp Configuration Registers Temperature Conversion and Tcrit. Registers S/W Set Sensor External 2 Temp SMBus Config. S/W_SHUTDOWN S/W Set Sensor External 3 Temp PIN Decode External Diode 1 SHDN_SEL H/W SHUTDOWN External Diode 2 Temperature Conversion Internal Diode VREF H/W_SHUTDOWN Voltage Conversion TRIP_SET SYS_SHDN Figure 6.2 Block Diagram of Critical/Thermal Shutdown 6.1.1 SYS_SHDN Pin The SYS_SHDN pin is an active low dedicated system interrupt. This pin is asserted low when: 1. The programmed temperature channel (see Section 6.1.2) exceeds the hardware set limit (see Section 6.1.3). 2. Any of the measured temperature channels meet or exceed their programmed TCRIT limits and have been linked to the SYS_SHDN pin (see Section 7.10). 3. Any of the measured temperature channels meet or exceed their programmed High limits and have been linked to the SYS_SHDN pin (see Section 7.11). SMSC EMC2113 23 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet When the SYS_SHDN pin is asserted, it will remain asserted until the measured temperatures drop below the respective limits minus the hysteresis. At this point, the pin will be released automatically. 6.1.2 SHDN_SEL Pin The EMC2113 has a ‘strappable’ input (SHDN_SEL) allowing for configuration of the hardware Critical/Thermal Shutdown input channel. The pull-up resistor used on this pin identifies which configuration setting is used as shown in Table 6.1, "SHDN_SEL Pin Decode". . Table 6.1 SHDN_SEL Pin Decode PULL UP RESISTOR MODE / DIODE CHANNEL < 4.7k Ohm EXTERNAL DIODE 1 CONFIG EXTERNAL DIODE 2 CONFIG AMD CPU on External Diode 1 Beta Compensation disabled REC disabled Beta and REC controls are locked Beta Compensation enabled (auto) REC enabled Beta and REC controls are not locked 6.8k Ohm 2N3904 on External Diode 1 Beta Compensation disabled REC enabled Beta and REC controls are locked Beta Compensation enabled (auto) REC enabled Beta and REC controls are not locked 10k Ohm Intel CPU or 2N3904 on External Diode 1 Beta Compensation enabled (auto) REC enabled Beta and REC controls are locked Beta Compensation enabled (auto) REC enabled Beta and REC controls are not locked 15k Ohm Internal Diode Beta Compensation enabled (auto) REC enabled Beta and REC controls are not locked Beta Compensation enabled (auto) REC enabled Beta and REC controls are not locked 22k Ohm Intel CPU or 2N3904 on External Diode 2 Beta Compensation enabled (auto) REC enabled Beta and REC controls are not locked Beta Compensation enabled (auto) REC enabled Beta and REC controls are locked > 33k Ohm Intel CPU or 2N3904 on External Diode 1 Beta Compensation enabled (auto) REC enabled Beta and REC controls are not locked Beta Compensation enabled (auto) REC enabled Beta and REC controls are not locked APPLICATION NOTE: The SHDN_SEL pin decode settings with Beta Compensation enabled (auto) will support a diode connected 2N3904 diode normally. 6.1.3 TRIP_SET Pin The EMC2113’s TRIP_SET pin is an analog input to the Critical/Thermal Shutdown block which sets the Thermal Shutdown temperature. The system designer creates a voltage level at the input through a simple resistor connected to GND as shown in Figure 6.2, "Block Diagram of Critical/Thermal Shutdown". The value of this resistor is used to create an input voltage on the TRIP_SET pin which is translated into a temperature ranging from 65°C to 127°C. APPLICATION NOTE: Current only flows when the TRIP_SET pin is being monitored. At all other times, the internal reference voltage is removed and the TRIP_SET pin will be pulled down to ground. Revision 1.2 (10-08-09) 24 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet APPLICATION NOTE: The TRIP_SET pin circuitry is designed to use a 1% resistor externally. Using a 1% resistor will result in the Thermal / Critical Shutdown temperature being decoded correctly. If a 5% resistor is used, then the Thermal / Critical Shutdown temperature may be decoded with as much as ±1°C error. Table 6.2 TRIP_SET Resistor Setting TTRIP (°C) RSET (1%) TTRIP (°C) RSET (1%) 65 0.0 97 1240 66 28.7 98 1330 67 48.7 99 1400 68 69.8 100 1500 69 90.9 101 1580 70 113 102 1690 71 137 103 1820 72 158 104 1960 73 182 105 2050 74 210 106 2210 75 237 107 2370 76 261 108 2550 77 294 109 2740 78 324. 110 2940 79 348 111 3160 80 383 112 3480 81 412 113 3740 82 453 114 4120 83 487 115 4530 84 523 116 4990 85 562 117 5490 86 604 118 6040 87 649 119 6810 88 698 120 7870 89 750 121 9090 90 787 122 10700 91 845 123 12700 92 909 124 15800 93 953 125 20500 SMSC EMC2113 25 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 6.2 TRIP_SET Resistor Setting (continued) 6.2 TTRIP (°C) RSET (1%) TTRIP (°C) RSET (1%) 94 1020 126 29400 95 1100 127 49900 96 1150 65 Open Fan Control Modes of Operation The EMC2113 has four modes of operation for the fan driver. Each mode uses Ramp Rate control and the Spin Up Routine. 1. PWM Setting Mode - in this mode of operation, the user directly controls the PWM duty cycle setting. Updating the Fan Driver Setting Register (see Section 7.22, "Fan Setting Registers") will instantly update the fan drive. The driver uses the Spin Up Routine and has user definable ramp rate controls. This is the default mode. The PWM Setting Mode is enabled by clearing both the EN_ALGO bit in the Fan Configuration Register (see Section 7.24) and the LUT_LOCK bit in the Look Up Table Configuration Register (see Section 7.34). Whenever the PWM Setting Mode is enabled, the current drive will be changed to what was last written into the Fan Driver Setting Register. The Ramp Rate is controlled by the settings of the Max Step register (see Section 7.28) and Update Period controls (Section 7.24) and must be enabled via the EN_RRC bit (see Section 7.25). 2. Fan Speed Control Mode (FSC) - in this mode of operation, the user determines a fan speed and the drive setting is automatically updated to achieve this target speed. The algorithm uses the Spin Up Routine and has user definable ramp rate controls. This mode is enabled by clearing the LUT_LOCK bit in the Look Up Table (LUT) Configuration Register and setting the EN_ALGO bit in the Fan Configuration Register. 3. Using the Look Up Table with Fan Drive Settings (PWM Setting w/ LUT Mode) - In this mode of operation, the user programs the Look Up Table with PWM duty cycle settings and corresponding temperature thresholds. The fan drive is set based on the measured temperatures and the corresponding drive settings. The fan driver uses the Spin Up Routine and has user definable ramp rate controls. This mode is enabled by programming the Look Up Table then setting the LUT_LOCK bit while the EN_ALGO bit is set to ‘0’. The RPM / PWM bit in the Look Up Table Configuration Register MUST be set to ‘1’ or the PWM drive settings will be incorrectly set. 4. Using the Look Up Table with Fan Speed Control algorithm (FSC w/ LUT Mode)- In this mode of operation, the user programs the Look Up Table with fan speed target values and corresponding temperature thresholds. The TACH Target Register will be set based on the measured temperatures and the corresponding target settings. The PWM drive settings will be determined automatically based on the RPM-based Fan Speed Control Algorithm. PWM drive settings will be determined automatically based on the RPM-based Fan Speed Control Algorithm This mode is enabled by programming the Look Up Table then setting the LUT_LOCK bit while the EN_ALGO bit is set to ‘1’. The RPM / PWM bit in the Look Up Table Configuration Register MUST be set to ‘0’ or the TACH Target values will be incorrectly set. APPLICATION NOTE: It is important that the TACH Target settings are in the proper format when using the RPMbased Fan Speed Control Algorithm. Revision 1.2 (10-08-09) 26 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 6.3 Fan Controls Active for Operating Mode DIRECT PWM SETTING MODE FSC MODE Fan Driver Setting (read / write) Fan Driver Setting (read only) Fan Driver Setting (read only) Fan Driver Setting (read only) EDGES[1:0] EDGES[1:0] (Fan Configuration) EDGES[1:0] EDGES[1:0] - RANGE[1:0] (Fan Configuration) - RANGE[1:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) LEVEL (Spin Up Configuration) LEVEL (Spin Up Configuration) LEVEL (Spin Up Configuration) LEVEL (Spin Up Configuration) SPINUP_TIME[1:0] (Spin Up Configuration) SPINUP_TIME[1:0] (Spin Up Configuration) SPINUP_TIME[1:0] (Spin Up Configuration) SPINUP_TIME[1:0] (Spin Up Configuration) Fan Max Step Fan Max Step Fan Max Step Fan Max Step - Fan Minimum Drive Valid TACH Count Valid TACH Count Valid TACH Count Valid TACH Count - TACH Target (read / write) - TACH Target (read only) TACH Reading TACH Reading TACH Reading TACH Reading - - Look Up Table Drive / Temperature Settings (read only) Look up Table Drive / Temperature Settings (read only) - DRIVE_FAIL_CNT [1:0] (Spin Up Configuration) + Fan Drive Fail Band - DRIVE_FAIL_CNT [1:0] (Spin Up Configuration) + Fan Drive Fail Band 6.3 DIRECT PWM SETTING W/ LUT MODE FSC W/ LUT MODE Fan Minimum Drive PWM Fan Driver The EMC2113 supports a high or low frequency PWM driver. The output can be configured as either push-pull or open drain and the frequency ranges from 9.5Hz to 26kHz in four programmable frequency bands. The PWM frequency range is coarsely adjusted via the PWM Base Frequency register (Section 7.19) with a fine tune adjustment performed via the PWM Divider registers (see Section 7.23). General PWM operation is governed by the PWM Configuration register (see Section 7.18). 6.4 Fan Control Look-Up Table The EMC2113 uses a look-up table to apply a user-programmable fan control profile based on measured temperature to the fan driver. In this look-up table, each temperature channel is allowed to control the fan drive output independently (or jointly) by programming up to eight pairs of temperature and drive setting entries. The Look Up Table supports external data pushed into the device by the Host in either DTS or standard format. Each of the four temperature channels used by the Look Up table is generated from measured temperature sensors on the EMC2113 or from an external source. SMSC EMC2113 27 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet The user programs the look-up table based on the desired operation. If the RPM-based Fan Speed Control Algorithm is to be used (see Section 6.6, "RPM-Based Fan Speed Control Algorithm (FSC)"), then the user must program a fan speed target for each temperature setting of interest. Alternately, if the RPM-based Fan Speed Control Algorithm is not to be used, then the user must program a PWM setting for each temperature setting of interest. If the measured temperature on the External Diode channel meets or exceeds any of the temperature thresholds for any of the channels, the fan output will be automatically set to the desired setting corresponding to the exceeded temperature. In cases where multiple temperature channel thresholds are exceeded, the highest fan drive setting will take precedence. Figure 6.3, "Fan Control Look-Up Table Example" shows an example of this behavior using a single channel. When the measured temperature drops to a point below a lower threshold minus the hysteresis value, the fan output will be set to the corresponding lower set point. To turn the fan off, there are 2 methods: The first is to set the Temps1-4 Setting 1 values (+ hysteresis) above the temperatures desired for the fan to turn off. When the temperatures fall below Temps1-4 (out of the LUT) by the hysteresis amount, the fan drive will be set to 0. The second is to set the Drive 1 value to 0% (or 0RPM) as well as the Temp 1-4 values to the temperatures (+ hysteresis) at which the fan should turn off. This method will reduce the effective amount of fan drive settings to 7. Fan Setting Temp S6 T6 T6 - Hyst S5 T5 T5 - Hyst S4 T4 T4 - Hyst Averaged Temperature T3 T3 - Hyst S3 Fan Setting S2 T2 T2 - Hyst T1 Measurement taken S1 Time Figure 6.3 Fan Control Look-Up Table Example Revision 1.2 (10-08-09) 28 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 6.4.1 Programming the Look Up Table When the Look Up Table is used, it must be loaded and configured correctly based on the system requirements. The following steps outline the procedure. 1. Determine whether the Look Up Table will drive a PWM duty cycle or a tachometer target value and set the RPM / PWM bit in the Fan LUT Configuration Register (see Section 7.34, "Look Up Table Configuration Register"). 2. Determine which measurement channels (up to four) are to be used with the Look Up Table and set the TEMP1_CFG, TEMP3_CFG and TEMP4_CFG bits accordingly in the Fan LUT Configuration Register. 3. For each step to be used in the LUT, set the Fan Setting (either PWM or TACH Target as set by the RPM / PWM bit). If a setting is not used, then set it to FFh (if a PWM) or 00h (if a TACH Target). Load the lowest settings first in ascending order (i.e. Fan Setting 1 is the lowest setting greater than “off”. Fan Setting 2 is the next highest setting, etc.). See Section 7.35, "Look Up Table Registers". 4. For each step to be used in the LUT, set each of the measurement channel thresholds. These values must be set in the same data format that the data is presented. If DTS is to be used, then the format should be in temperature with a maximum threshold of 100°C (64h). If a measurement channel is not used, then set the threshold at FFh. 5. Update the threshold hysteresis to be smaller than the smallest table step. 6. Configure the RPM-based Fan Speed Control Algorithm if it is to be used. See Section 7.24, "Fan Configuration 1 Register" for more details. 7. Set the LUT_LOCK bit to enable the Look Up Table and begin fan control in the Fan LUT Configuration Register. 6.4.2 DTS Support The EMC2113 supports DTS (Intel’s Digital Temperature Sensor) data in the Fan Control Look Up Table. Intel’s DTS data is a positive number that represents the processor’s relative temperature below a fixed value called TCONTROL which is generally equal to 100°C for Intel Mobile processors. For example, a DTS value of 10°C means that the actual processor temperature is 10°C below TCONTROL or equal to 90°C. Either or both of the Pushed Temperature Registers can be written with DTS data and used to control the fan driver. When DTS data is entered, then the USE_DTS_Fx bit must be set in the Fan LUT Configuration register. Once this bit is set, the DTS data entered is automatically subtracted from a value of 100°C. This delta value is then used in the Look Up Table as standard temperature data. APPLICATION NOTE: The device is designed with the assumption that TCONTROL is 100°C. As such, all DTS related conversions are done based on this value including Look Up Table comparisons. If TCONTROL is adjusted (i.e. TCONTROL is shifted to 105°C), then all of the Look Up Table thresholds should be adjusted by a value equal to TCONTROL - 100°C. 6.5 PWM Input The EMC2113 supports a PWM input that is used as an input to the fan speed control Look Up Table. This is controlled by the PUSH1_CFG bit and either the TEMP1_CFG or TEMP3_CFG bits in the Look Up Table Configuration register (see Section 7.34). When a signal is driven into the PWM_IN pin, then the device will automatically calculate the duty cycle of the input signal (provided that the frequency is within the specified range). This value is stored in the PWM Input Duty Cycle register and may be used as an input to the Look Up Table. APPLICATION NOTE: The PWM Input duty cycle value is a unit-less value that does not correspond to specific temperature values. When used in the Fan Control LUT, It is compared against unit-less 7bit values that represent PWM duty cycle thresholds to control the desired fan speed. SMSC EMC2113 29 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet This functionality is always active. If the pin does not transition, then it will assume 100% duty cycle or 0% duty cycle based on the pin voltage. The data range required by the Look Up Table is 0 to 127 so 100% duty cycle corresponds to 127 and 0% corresponds to 0. The duty cycle measured on the PWM_IN pin is compared against a user programmed PWM High Limit. If the measured duty cycle meets or exceeds this value, then it may cause the ALERT pin to be asserted (default operation is to mask this event from asserting the ALERT pin). 6.6 RPM-Based Fan Speed Control Algorithm (FSC) The EMC2113 includes an RPM-based Fan Speed Control Algorithm. This fan control algorithm uses Proportional, Integral, and Derivative terms to automatically approach and maintain the system’s desired fan speed to an accuracy directly proportional to the accuracy of the clock source. The desired tachometer count is set by the user inputting the desired number of 32.768KHz cycles that occur per fan revolution. This is done either manually or by programming the Temperature LookUp Table. The user may change the target count at any time. The user may also set the target count to FFh in order to disable the fan driver for lower current operation. For example, if a desired RPM rate for a 2-pole fan is 3000 RPM then the user would input the hexidecimal equivalent of 1296 (51h in the TACH Target Register). This number represents the number of 32.768KHz cycles that would occur during the time it takes the fan to complete a single revolution when it is spinning at 3000RPMs. The EMC2113’s RPM-based Fan Speed Control Algorithm has programmable configuration settings for parameters such as ramp-rate control and spin up conditions. The fan driver automatically detects and attempts to alleviate a stalled/stuck fan condition while also asserting the ALERT pin. The EMC2113 works with fans that operate up to 16,000 RPMs and provide a valid tachometer signal. 6.6.1 Programming the RPM-Based Fan Speed Control Algorithm The RPM-based Fan Speed Control Algorithm powers-up disabled. The following registers control the algorithm. The EMC2113 fan control registers are pre-loaded with defaults that will work for a wide variety of fans so only the TACH Target Register is required to set a fan speed. The other fan control registers can be used to fine-tune the algorithm behavior based on application requirements. Note that steps 1 - 7 are optional and need only be performed if the default settings do not provide the desired fan response. 1. Set the Valid TACH Count Register to maximum number of tach counts to indicate the fan is spinning. 2. Set the Spin Up Configuration Register to the Spin Up Level and Spin Time desired. 3. Set the Fan Step Register to the desired step size. 4. Set the Fan Minimum Drive Register to the minimum drive value that will maintain fan operation. 5. Set the Update Time and Edges options in the Fan Configuration Register. 6. Set the TACH Target Register to the desired tachometer count. 7. Enable the RPM-based Fan Speed Control Algorithm by setting the EN_ALGO bit. 6.7 Tachometer Measurement The tachometer measurement circuitry is used in conjunction with the RPM-based Fan Speed Control Algorithm to update the fan driver output. Additionally, it can be used in Direct Setting mode as a diagnostic for host based fan control. Revision 1.2 (10-08-09) 30 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet The EMC2113 monitors the TACH signal in real time. It constantly updates the tachometer measurement by reporting the number of clocks between a user programmed number of edges on the TACH signal (see Table 7.34, "Minimum Edges for Fan Rotation"). Using the Tach Period Measurement method provides fast response times for the RPM-based Fan Speed Control Algorithm and the data is presented as a count value that represents the fan RPM period. When this method is used, all fan target values must be input as a count value for proper operation. APPLICATION NOTE: The Tach Period Measurement method works independently of the drive settings. If the device is put into Direct Setting and the fan drive is set at a level that is lower than the fan can operate (including zero drive), then the tachometer measurement may signal a Stalled Fan condition and assert an interrupt. 6.7.1 Stalled Fan A Stalled fan is detected if the tach counter exceeds the user-programmable Valid TACH Count setting. The EMC2113 will flag the fan as stalled and trigger an interrupt. If the RPM-based Fan Speed Control Algorithm is enabled, the algorithm will automatically attempt to restart the fan until it detects a valid tachometer level or is disabled. The FAN_STALL Status bit indicates that a stalled fan was detected. This bit is checked conditionally depending on the mode of operation. 6.7.2 When the Direct Setting Mode or Direct Setting with LUT Mode are enabled, the FAN_STALL interrupt will be masked for the duration of the programmed Spin Up Time (see Table 7.44, "Spin Time"). This is to allow the fan opportunity to reach a valid speed without generating unnecessary interrupts. In Direct Setting Mode or Direct Setting with LUT Mode, whenever the drive value is changed from 00h, the FAN_STALL interrupt will be masked for the duration of the programmed Spin Up Time to allow the fan opportunity to reach a valid speed without generating unnecessary interrupts. In Direct Setting Mode or Direct Setting w/ LUT Mode, and the tachometer measurement is using the Tach Period Measurement method, then whenever the TACH Reading Register value exceeds the Valid TACH Count Register setting, the FAN_STALL status bit will be set. When using the RPM-based Fan Speed Control Algorithm (either FSC Mode or LUT with FSC Mode), the stalled fan condition is checked whenever the Update Time is met and the fan drive setting is updated. It is not a continuous check. Aging Fan or Invalid Drive Detection The EMC2113 contains circuitry that detects that the programmed fan speed can be reached by the fan. If the target fan speed cannot be reached within a user defined band of tach counts at maximum drive then the DRIVE_FAIL status bit is set and the ALERT pin is asserted. This is useful to detect aging fan conditions (where the fan’s natural maximum speed degrades over time) or incorrect fan speed settings. 6.8 Spin Up Routine The EMC2113 also contains programmable circuitry to control the spin up behavior of the fan driver to ensure proper fan operation. The Spin Up Routine is initiated under the following conditions when the Tach Period Measurement method of tach measurement is used: This applies to both the RPMbased Fan Speed Control Algorithm mode, or Direct Setting mode (with or without the Look Up Table - when enabled). 1. The TACH Target Register value changes from a value of FFh to a value that is less than the Valid TACH Count (see Section 7.30, "Valid TACH Count Register"). 2. The RPM-based Fan Speed Control Algorithm’s measured TACH Reading Register value is greater than the Valid TACH Count setting. SMSC EMC2113 31 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet When the Spin Up Routine is operating, the fan driver is set to full scale (optional) for one quarter of the total user defined spin up time. For the remaining spin up time, the fan driver output is set to a user defined level (30% through 65% drive). After the Spin Up Routine has finished, the EMC2113 measures the TACH signal. If the measured TACH Reading Register value is higher than the Valid TACH Count Register setting, the FAN_SPIN status bit is set and the Spin Up Routine will automatically attempt to restart the fan. Figure 6.4, "Spin Up Routine" shows an example of the Spin Up Routine in response to a programmed fan speed change based on the first condition above. 100% (optional) 30% through 65% Fan Step New Target Count Algorithm controlled drive Prev Target Count = FFh ¼ of Spin Up Time Update Time Spin Up Time Check TACH Target Count Changed Target Count Reached Figure 6.4 Spin Up Routine 6.9 Ramp Rate Control The PWM output drive can be configured with automatic ramp rate control. If the RPM-based Fan Speed Control Algorithm is used, then this ramp rate control is automatically used based on the fan control derivative option settings. The user programs a maximum step size for the PWM setting and an update time. The update time varies from 100ms to 1.6s while the PWM maximum step can vary from 1 PWM count to 31 PWM counts. When a new PWM duty cycle value is entered (either directly, as a result of the FSC Algorithm adjusting the output PWM to meet the programmed TACH Target value, or as a result of the ramp rate control circuitry), the delta from the next PWM and the previous PWM is determined. If this delta is greater than the maximum fan step settings, then the PWM is adjusted by the maximum fan step settings. The PWM duty cycle is adjusted (and the delta recalculated) every 100ms to 1.6s as determined by the Update Time until the target PWM setting is reached. See Figure 6.5, "Ramp Rate Control". Revision 1.2 (10-08-09) 32 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Next Desired Setting Max Step Max Step Previous Setting Update Time Update Time Setting Changed Figure 6.5 Ramp Rate Control 6.10 Watchdog Timer The EMC2113 contains an internal Watchdog Timer for the fan driver. The Watchdog timer monitors the SMBus traffic for signs of activity and works in two different modes based upon device operation. These modes are Power Up Operation and Continuous Operation as described below. For either mode of operation, if four (4) seconds elapse without activity detected by the host, then the watchdog will be triggered and the following will occur: 1. The WATCH status bit will be set which will cause the ALERT pin to be asserted. 2. The fan driver will be set to full scale drive. It will remain at full scale drive until it is disabled. APPLICATION NOTE: When the Watchdog timer is activated the Fan Speed Control Algorithm is automatically disabled. Disabling the Watchdog will not automatically set the fan drive nor re-activate the Fan Speed Control Algorithm. This must be done manually. 6.10.1 Power Up Operation The Watchdog Timer only starts immediately after power-up and once it has been triggered or deactivated will not restart although it can be configured to operate in Continuous operation. In the Power Up Operation, the Watchdog Timer is disabled by any of the following actions: 1. Writing the Fan Setting Register will disable the Watchdog Timer. 2. Enabling the RPM-based Fan Speed Control Algorithm by setting the EN_ALGO bit will disable the Watchdog Timer. The fan driver will be set based on the RPM-based Fan Speed Control Algorithm. 3. Changing the Watchdog operating mode by setting the WD_EN bit. Writing any other configuration registers will not disable the Watchdog Timer upon power up. SMSC EMC2113 33 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 6.10.2 Continuous Operation When configured to operate in Continuous Operation, the Watchdog timer will start immediately. It can be disabled by any access (read or write) to the SMBus register set. Upon completion of SMBus activity, the Watchdog timer is reset and restarted. 6.11 Fault Queue The EMC2113 contains a programmable fault queue on all fault conditions. The fault queue defines how many consecutive out-of-limit conditions must be reported before the corresponding status bit is set (and the ALERT pin asserted). 6.12 ALERT Pin The ALERT pin acts as an active low open drain interrupt that flags several conditions. It will be asserted low when: 1. The FSC Algorithm detects a stalled fan. 2. The measured temperature meets or exceeds its programmed high limit or drops below its programmed low limit. 3. A diode fault is detected. 4. The PWM input duty cycle has exceeded its programmed limit. Once asserted, the ALERT pin will remain asserted until the status bits have been cleared or the MASK bit has been set. 6.13 Temperature Monitoring The EMC2113 can monitor the temperature of up to three (3) externally connected diodes as well as the internal or ambient temperature. Each channel is configured with Resistance Error Correction, BJT Transistor model support, and Averaging enabled or disabled based on user settings and system requirements. All temperature channels offer 1°C accuracy and 0.125°C resolution. 6.13.1 Dynamic Averaging The EMC2113 supports dynamic averaging. When enabled, this feature changes the conversion time for all channels based on the selected conversion rate. This essentially increases the averaging factor as shown in Table 6.4, "Dynamic Averaging Behavior". The benefits of Dynamic Averaging are improved noise rejection due to the longer integration time as well as less random variation on the temperature measurement. Table 6.4 Dynamic Averaging Behavior AVERAGING FACTOR (RELATIVE TO 11-BIT CONVERSI0N) CONVERSION RATE DYNAMIC AVERAGING ENABLED DYNAMIC AVERAGING DISABLED 1 / sec 8x 1x 2 / sec 4x 1x 4 / sec 2x 1x Continuous 1x 1x Revision 1.2 (10-08-09) 34 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 6.13.2 Resistance Error Correction The EMC2113 includes active Resistance Error Correction to remove the effect of up to 100 ohms of series resistance. Without this automatic feature, voltage developed across the parasitic resistance in the remote diode path causes the temperature to read higher than the true temperature is. The error induced by parasitic resistance is approximately +0.7°C per ohm. Sources of parasitic resistance include bulk resistance in the remote temperature transistor junctions, series resistance in the CPU, and resistance in the printed circuit board traces and package leads. Resistance error correction in the EMC2113 eliminates the need to characterize and compensate for parasitic resistance in the remote diode path. 6.13.3 Beta Compensation The forward current gain, or beta, of a transistor is not constant as emitter currents change. As well, it is not constant over changes in temperature. The variation in beta causes an error in temperature reading that is proportional to absolute temperature. This correction is done by implementing the BJT or transistor model for temperature measurement. For discrete transistors configured with the collector and base shorted together, the beta is generally sufficiently high such that the percent change in beta variation is very small. For example, a 10% variation in beta for two forced emitter currents with a transistor whose ideal beta is 50 would contribute approximately 0.25°C error at 100°C. However for substrate transistors where the base-emitter junction is used for temperature measurement and the collector is tied to the substrate, the proportional beta variation will cause large error. For example, a 10% variation in beta for two forced emitter currents with a transistor whose ideal beta is 0.5 would contribute approximately 8.25°C error at 100°C. The Beta Compensation circuitry in the EMC2113 corrects for this beta variation to eliminate any error which would normally be induced. It automatically detects the appropriate beta setting to use. 6.13.4 Ideality Configuration The EMC2113 is designed for external diodes with an ideality factor of 1.008. Not all external diodes, processor or discrete, will have this exact value. This variation of the ideality factor introduces error in the temperature measurement which must be corrected for. This correction is typically done using programmable offset registers. Since an ideality factor mismatch introduces an error that is a function of temperature, this correction is only accurate within a small range of temperatures. To provide maximum flexibility to the user, the EMC2113 provides a register for each external diode where the ideality factor of the diode used may be programmed to eliminate errors across all temperatures. APPLICATION NOTE: When monitoring a substrate transistor or CPU diode and beta compensation is enabled, the Ideality Factor should not be adjusted. Beta Compensation automatically corrects for most ideality errors. 6.13.5 Digital Averaging The external diode channels support a 4x digital averaging filter. Every cycle, this filter updates the temperature data based an a running average of the last 4 measured temperature values. The digital averaging reduces temperature flickering and increases temperature measurement stability. The digital averaging can be disabled by setting the DIS_AVG bit in the Configuration 2 Register (see Section 7.25, "Fan Configuration 2 Register"). 6.14 Diode Connections The External Diode 1 channel can support a diode-connected transistor (such as a 2N3904) or a substrate transistor requiring the BJT or transistor model (such as those found in a CPU or GPU) as shown in Figure 6.6, "Diode Connections". The External Diode 2 channel supports any diode connection shown or it can be configured to operate in anti-parallel diode (APD) mode. When configured in APD mode, a third temperature channel is SMSC EMC2113 35 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet available that shares the DP2 and DN2 pins. When in this mode, both the external diode 2 channel and external diode 3 channel thermal diodes must be connected as diodes. Diode 3 to DP to DP to DN Local Ground Typical remote Typical remote substrate transistor discrete PNP transistor i.e. CPU substrate PNP i.e. 2N3906 to DN Typical remote discrete NPN transistor i.e. 2N3904 Diode 2 to DP to DP / DN to DN to DN / DP Anti-parallel diodes using discrete NPN transistors Figure 6.6 Diode Connections 6.14.1 Anti-Parallel Diodes The EMC2113 supports connecting two external diodes to the DN2 / DP3 and DP2 / DN3 pins. This second diode is connected in an anti-parallel configuration with respect to the first diode. When the the External Diode 2 channel is measured, the anti-parallel diode will be reverse biased. Likewise, when the External Diode 3 channel is measured, the first diode will be reverse biased. CPU diodes should not be used with anti-parallel diode connections. 6.14.2 Diode Faults The EMC2113 actively detects an open and short condition on each measurement channel. When a diode fault is detected, the temperature data MSByte is forced to a value of 80h and the FAULT bit is set in the Status Register. When the External Diode 2 channel is configured to operate in APD mode, the circuitry will detect independent open fault conditions; however, a short condition will be shared between the External Diode 2 and External Diode 3 channels. Revision 1.2 (10-08-09) 36 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Chapter 7 Fan Control Register Set 7.1 Register Map The following registers are accessible through the SMBus Interface. All register bits marked as ‘-’ will always read ‘0’. A write to these bits will have no effect. Table 7.1 EMC2113 Register Set ADDR R/W REGISTER NAME DEFAULT VALUE LOCK PAGE Stores the integer data of the Internal Diode 00h No Page 44 Stores the fractional data of the Internal Diode 00h No Page 44 FUNCTION Temperature Registers 00h R Internal Temp Reading High Byte 01h R Internal Temp Reading Low Byte 02h R External Diode 1 Temp Reading High Byte Stores the integer data of External Diode 1 00h No Page 44 03h R External Diode 1 Temp Reading Low Byte Stores the fractional data of External Diode 1 00h No Page 44 04h R External Diode 2 Temp Reading High Byte Stores the integer data of External Diode 2 00h No Page 44 05h R External Diode 2 Temp Reading Low Byte Stores the fractional data of External Diode 2 00h No Page 44 06h R External Diode 3 Temp Reading High Byte Stores the integer data of External Diode 3 00h No Page 44 07h R External Diode 3 Temp Reading Low Byte Stores the fractional data of External Diode 3 00h No Page 44 0Ah R Critical/Thermal Shutdown Temperature Stores the calculated Critical/Thermal Shutdown temperature high limit derived from TRIP_SET pin voltage N/A No Page 45 0Ch R/W Pushed Temperature 1 Stores the integer data for Pushed Temperature 1 to drive the LUT 00h No Page 45 0Dh R/W Pushed Temperature 2 Stores the integer data for Pushed Temperature 2 to drive the LUT 00h No Page 45 0Fh R PWM Input Duty Cycle Stores the calculated duty cycle on the PWM pin 00h No Page 46 10h R TRIP_SET Voltage Stores the measured voltage on the TRIP_SET pin FFh No Page 46 SMSC EMC2113 37 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.1 EMC2113 Register Set (continued) ADDR REGISTER NAME R/W FUNCTION DEFAULT VALUE LOCK PAGE Diode Configuration 11h R/W External Diode 1 Ideality Register Stores the Ideality Factor used for External Diode 1 12h SWL Page 46 12h R/W External Diode 2 Ideality Register Stores the Ideality factor used for External Diode 2 12h SWL Page 46 13h R/W External Diode 3 Ideality Register Stores the Ideality factor used for External Diode 3 12h SWL 14h R/W External Diode 1 Beta Configuration Configures the beta compensation settings for External Diode 1 10h SWL Page 48 15h R/W External Diode 2 Beta Configuration Configures the beta compensation settings for External Diode 2 10h SWL Page 48 17h R/W External Diode REC Configuration Configures the Resistance Error Correction functionality for all external diodes 07h SWL Page 49 Page 46 Critical Temperature Limit Registers 19h R/W once External Diode 1 Tcrit Limit Stores the critical temperature limit for External Diode 1 64h (100°C) Write Once Page 50 1Ah R/W once External Diode 2 Tcrit Limit Stores the critical temperature limit for External Diode 2 64h (100°C) Write Once Page 50 1Bh R/W once External Diode 3 Tcrit Limit Stores the critical temperature limit for External Diode 3 64h (100°C) Write Once Page 50 1Dh R/W once Internal Diode Tcrit Limit Stores the critical temperature limit for the Internal Diode 64h (100°C) Write Once Page 50 Stores the status bits for all temperature channel tcrit limits 00h No Page 53 Configuration and control 1Fh R Tcrit Status 20h R/W Configuration Configures the Thermal / Critical Shutdown masking options 00h SWL Page 50 21h R/W Configuration 2 Controls the conversion rate for monitoring of all channels 0Eh SWL Page 51 23h R Interrupt Status Stores the status bits for temperature channels 00h No Page 53 24h R-C High Limit Status Stores the status bits for all temperature channel high limits 00h No Page 53 25h R-C Low Limit Status Stores the status bits for all temperature channel low limits 00h No Page 53 26h R-C Diode Fault Stores the status bits for all temperature channel diode faults 00h No Page 53 27h R-C Fan Status Stores the status bits for the RPMbased Fan Speed Control Algorithm 00h No Page 54 28h R/W Interrupt Enable Register Controls the masking of interrupts on all temperature channels 00h No Page 54 Revision 1.2 (10-08-09) 38 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.1 EMC2113 Register Set (continued) REGISTER NAME FUNCTION R/W Fan Interrupt Enable Register 2Ah R/W PWM Driver Config 2Bh R/W PWM Driver Base Frequency ADDR R/W 29h DEFAULT VALUE LOCK PAGE Controls the masking of interrupts for the Fan Driver 00h No Page 55 Configures the PWM driver 00h No Page 56 Controls the base frequency of the PWM driver 00h No Page 56 Temperature High Limit Registers 30h R/W External Diode 1 Temp High Limit High limit for External Diode 1 55h (+85°C) SWL Page 57 31h R/W External Diode 2 Temp High Limit High limit for External Diode 2 55h (+85°C) SWL Page 57 32h R/W External Diode 3 Temp High Limit High limit for External Diode 3 55h (+85°C) SWL Page 57 34h R/W Internal Diode High Limit High Limit for Internal Diode 55h (85°C) SWL Page 57 Temperature Low Limit Registers 38h R/W External Diode 1 Temp Low Limit Low Limit for External Diode 1 00h (0°C) SWL Page 57 39h R/W External Diode 2 Temp Low Limit Low Limit for External Diode 2 00h (0°C) SWL Page 57 3Ah R/W External Diode 3 Temp Low Limit Low Limit for External Diode 3 00h (0°C) SWL Page 57 3Ch R/W Internal Diode Low Limit Low Limit for Internal Diode 00h (0°C) SWL Page 57 7Fh SWL Page 57 PWM Input Duty Cycle Limit 3Dh R/W PWM Input Duty Cycle High Limit Stores the high limit for the PWM input Duty Cycle Fan Control Registers 40h R/W Fan Setting Always displays the most recent fan driver input setting for Fan. If the RPM-based Fan Speed Control Algorithm is disabled, allows direct user control of the fan driver. 00h No Page 58 41h R/W PWM Divide Stores the divide ratio to set the frequency for the Fan 01h No Page 58 42h R/W Fan Configuration 1 Sets configuration values for the RPM-based Fan Speed Control Algorithm for the Fan 2Bh No Page 58 43h R/W Fan Configuration 2 Sets additional configuration values for the Fan driver 28h SWL Page 60 45h R/W Gain Holds the gain terms used by the RPM-based Fan Speed Control Algorithm for the Fan 2Ah SWL Page 62 SMSC EMC2113 39 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.1 EMC2113 Register Set (continued) REGISTER NAME FUNCTION DEFAULT VALUE LOCK PAGE R/W Fan Spin Up Configuration Sets the configuration values for Spin Up Routine of the Fan driver 19h SWL Page 62 47h R/W Fan Step Sets the maximum change per update for the Fan 10h SWL Page 64 48h R/W Fan Minimum Drive 66h (40%) SWL Page 64 49h R/W Fan Valid TACH Count Holds the minimum tachometer reading that indicates the fan is spinning properly F5h SWL Page 65 4Ah R/W Fan Drive Fail Band Low Byte Stores the number of Tach counts used to determine how the actual fan speed must match the target fan speed at full scale drive 00h SWL Page 65 4Bh R/W Fan Drive Fail Band High Byte 00h SWL 4Ch R/W TACH Target Low Byte Holds the target tachometer reading low byte for the Fan F8h No Page 66 4Dh R/W TACH Target High Byte Holds the target tachometer reading high byte for the Fan FFh No Page 66 4Eh R TACH Reading High Byte Holds the tachometer reading high byte for the Fan FFh No Page 66 4Fh R TACH Reading Low Byte Holds the tachometer reading low byte for the Fan F8h No Page 66 ADDR R/W 46h Sets the minimum drive value for the the Fan driver Look Up Table (LUT) 50h R/W LUT Configuration Stores and controls the configuration for the LUT 00h No Page 67 51h R/W LUT Drive 1 Stores the lowest programmed drive setting for the LUT FBh LUT Lock Page 68 52h R/W LUT Temp 1 Setting 1 Stores the threshold level for the External Diode 1 channel that is associated with the Drive 1 value 7Fh (127°C) LUT Lock Page 68 53h R/W LUT Temp 2 Setting 1 Stores the threshold level for the External Diode 2 channel that is associated with the Drive 1 value 7Fh (127°C) LUT Lock Page 68 54h R/W LUT Temp 3 Setting 1 Stores the threshold level for the External Diode 3 channel (or Pushed Temp 1 temp) that is associated with the Drive 1 value 7Fh (127°C) LUT Lock Page 68 55h R/W LUT Temp 4 Setting 1 Stores the threshold level for the Internal Diode channel (or Pushed Temp 2 temp) that is associated with the Drive 1 value 7Fh (127°C) LUT Lock Page 68 56h R/W LUT Drive 2 Stores the second programmed drive setting for the LUT E6h LUT Lock Page 68 57h R/W LUT Temp 1 Setting 2 Stores the threshold level for the External Diode 1 channel that is associated with the Drive 2 value 7Fh (127°C) LUT Lock Page 68 Revision 1.2 (10-08-09) 40 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.1 EMC2113 Register Set (continued) REGISTER NAME DEFAULT VALUE LOCK PAGE Stores the threshold level for the External Diode 2 channel that is associated with the Drive 2 value 7Fh (127°C) LUT Lock Page 68 LUT Temp 3 Setting 2 Stores the threshold level for the External Diode 3 channel (or Pushed Temp 1 temp) that is associated with the Drive 2 value 7Fh (127°C) LUT Lock Page 68 R/W LUT Temp 4 Setting 2 Stores the threshold level for the Internal Diode channel (or Pushed Temp 2 temp) that is associated with the Drive 2 value 7Fh (127°C) LUT Lock Page 68 5Bh R/W LUT Drive 3 Stores the third programmed drive setting for the LUT D1h LUT Lock Page 68 5Ch R/W LUT Temp 1 Setting 3 Stores the threshold level for the External Diode 1 channel that is associated with the Drive 3 value 7Fh (127°C) LUT Lock Page 68 5Dh R/W LUT Temp 2 Setting 3 Stores the threshold level for the External Diode 2 channel that is associated with the Drive 3 value 7Fh (127°C) LUT Lock Page 68 5Eh R/W LUT Temp 3 Setting 3 Stores the threshold level for the External Diode 3 channel (or Pushed Temp 1 temp) that is associated with the Drive 3 value 7Fh (127°C) LUT Lock Page 68 5Fh R/W LUT Temp 4 Setting 3 Stores the threshold level for the Internal Diode channel (or Pushed Temp 2 temp) that is associated with the Drive 3 value 7Fh (127°C) LUT Lock Page 68 60h R/W LUT Drive 4 Stores the fourth programmed drive setting for the LUT BCh LUT Lock Page 68 61h R/W LUT Temp 1 Setting 4 Stores the threshold level for the External Diode 1channel that is associated with the Drive 4 value 7Fh (127°C) LUT Lock Page 68 62h R/W LUT Temp 2 Setting 4 Stores the threshold level for the External Diode 2 channel that is associated with the Drive 4 value 7Fh (127°C) LUT Lock Page 68 63h R/W LUT Temp 3 Setting 4 Stores the threshold level for the External Diode 3 channel (or Pushed Temp 1 temp) that is associated with the Drive 4 value 7Fh (127°C) LUT Lock Page 68 64h R/W LUT Temp 4 Setting 4 Stores the threshold level for the Internal Diode channel (or Pushed Temp 2 temp) that is associated with the Drive 4 value 7Fh (127°C) LUT Lock Page 68 65h R/W LUT Drive 5 Stores the fifth programmed drive setting for the LUT A7h LUT Lock Page 68 66h R/W LUT Temp 1 Setting 5 Stores the threshold level for the External Diode 1 channel that is associated with the Drive 5 value 7Fh (127°C) LUT Lock Page 68 ADDR R/W 58h R/W LUT Temp 2 Setting 2 59h R/W 5Ah SMSC EMC2113 FUNCTION 41 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.1 EMC2113 Register Set (continued) REGISTER NAME DEFAULT VALUE LOCK PAGE Stores the threshold level for the External Diode 2 channel that is associated with the Drive 5 value 7Fh (127°C) LUT Lock Page 68 LUT Temp 3 Setting 5 Stores the threshold level for the External Diode 3 channel (or Pushed Temp 1 temp) that is associated with the Drive 5 value 7Fh (127°C) LUT Lock Page 68 R/W LUT Temp 4 Setting 5 Stores the threshold level for the Internal Diode channel (or Pushed Temp 2 temp) that is associated with the Drive 5 value 7Fh (127°C) LUT Lock Page 68 6Ah R/W LUT Drive 6 Stores the sixth programmed drive setting for the LUT 92h LUT Lock Page 68 6Bh R/W LUT Temp 1 Setting 6 Stores the threshold level for the External Diode 1 channel that is associated with the Drive 6 value 7Fh (127°C) LUT Lock Page 68 6Ch R/W LUT Temp 2 Setting 6 Stores the threshold level for the External Diode 2 channel that is associated with the Drive 6 value 7Fh (127°C) LUT Lock Page 68 6Dh R/W LUT Temp 3 Setting 6 Stores the threshold level for the External Diode 3 channel (or Pushed Temp 1 temp) that is associated with the Drive 6 value 7Fh (127°C) LUT Lock Page 68 6Eh R/W LUT Temp 4 Setting 6 Stores the threshold level for the Internal Diode channel (or Pushed Temp 2 temp) that is associated with the Drive 6 value 7Fh (127°C) LUT Lock Page 68 6Fh R/W LUT Drive 7 Stores the seventh programmed drive setting for the LUT 92h LUT Lock Page 68 70h R/W LUT Temp 1 Setting 7 Stores the threshold level for the External Diode 1 channel that is associated with the Drive 7 value 7Fh (127°C) LUT Lock Page 68 71h R/W LUT Temp 2 Setting 7 Stores the threshold level for the External Diode 2 channel that is associated with the Drive 7 value 7Fh (127°C) LUT Lock Page 68 72h R/W LUT Temp 3 Setting 7 Stores the threshold level for the External Diode 3 channel (or Pushed Temp 1 temp) that is associated with the Drive 7 value 7Fh (127°C) LUT Lock Page 68 73h R/W LUT Temp 4 Setting 7 Stores the threshold level for the Internal Diode channel (or Pushed Temp 2 temp) that is associated with the Drive 7 value 7Fh (127°C) LUT Lock Page 68 74h R/W LUT Drive 8 Stores the highest programmed drive setting for the LUT 92h LUT Lock Page 68 75h R/W LUT Temp 1 Setting 8 Stores the threshold level for the External Diode 1 channel that is associated with the Drive 8 value 7Fh (127°C) LUT Lock Page 68 ADDR R/W 67h R/W LUT Temp 2 Setting 5 68h R/W 69h Revision 1.2 (10-08-09) FUNCTION 42 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.1 EMC2113 Register Set (continued) REGISTER NAME DEFAULT VALUE LOCK PAGE Stores the threshold level for the External Diode 2 channel that is associated with the Drive 8 value 7Fh (127°C) LUT Lock Page 68 LUT Temp 3 Setting 8 Stores the threshold level for the External Diode 3 channel (or Pushed Temp 1 temp) that is associated with the Drive 8 value 7Fh (127°C) LUT Lock Page 68 R/W LUT Temp 4 Setting 8 Stores the threshold level for the Internal Diode channel (or Pushed Temp 2 temp) that is associated with the Drive 8 value 7Fh (127°C) LUT Lock Page 68 79h R/W LUT Temp 1 Hysteresis Stores the hysteresis that is used in the LUT for the Temp 1 Settings 0Ah (10°C) LUT Lock Page 68 7Ah R/W LUT Temp 2 Hysteresis Stores the hysteresis that is used in the LUT for the Temp 2 Settings 0Ah (10°C) LUT Lock Page 68 7Bh R/W LUT Temp 3 Hysteresis Stores the hysteresis that is used in the LUT for the Temp 3 Settings 0Ah (10°C) LUT Lock Page 68 7Ch R/W LUT Temp 4 Hysteresis Stores the hysteresis that is used in the LUT for the Temp 4 Settings 0Ah (10°C) LUT Lock Page 68 7Dh R/W LUT Configuration Stores and controls the configuration for the LUT 00h No Page 67 00h SWL Page 70 Indicates which pin selected options are enabled 00h No Page 70 Stores the unique Product ID 2Eh No Page 71 Manufacturer ID 5Dh No Page 72 Revision 81h No Page 72 ADDR R/W 76h R/W LUT Temp 2 Setting 8 77h R/W 78h FUNCTION Lock Register EFh R/W Software Lock Locks all SWL registers Revision Registers FCh R Product Features FDh R Product ID FEh R Manufacturer ID FFh R Revision During Power-On-Reset (POR), the default values are stored in the registers. A POR is initiated when power is first applied to the part and the voltage on the VDD supply surpasses the POR level as specified in the electrical characteristics. Any reads to undefined registers will return 00h. Writes to undefined registers will not have an effect. 7.1.1 Lock Entries The Lock Column describes the locking mechanism, if any, used for individual registers. All SWL registers are Software Locked and therefore made read-only when the LOCK bit is set. SMSC EMC2113 43 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 7.2 Temperature Data Registers Table 7.2 Temperature Data Registers ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 00h R Internal Diode High Byte Sign 64 32 16 8 4 2 1 00h 01h R Internal Diode Low Byte 0.5 0.25 0.125 - - - - - 00h 64 32 16 8 4 2 1 00h R External Diode 1 High Byte Sign 02h 0.25 0.125 - - - - - 00h R External Diode 1 Low Byte 0.5 03h 64 32 16 8 4 2 1 00h R External Diode 2 High Byte Sign 04h 0.25 0.125 - - - - - 00h R External Diode 2 Low Byte 0.5 05h 64 32 16 8 4 2 1 00h R External Diode 3 High Byte Sign 06h 0.25 0.125 - - - - - 00h R External Diode 3 Low Byte 0.5 07h The temperature measurement range is from -64°C to +127.875°C. The data format is a signed two’s complement number as shown in Table 7.3, "Temperature Data Format". Table 7.3 Temperature Data Format TEMPERATURE (°C) BINARY HEX (AS READ BY REGISTERS) Diode Fault 1000_0000_000b 80_00h -63.875 1100_0000_001b C0_20h -63 1100_0001_000b C1_00h -1 1111_1111_000b FF_00h -0.125 1111_1111_111b FF_E0h 0 0000_0000_000b 00_00h 0.125 0000_0000_001b 00_20h 1 0000_0001_000b 01_00h 63 0011_1111_000b 3F_00h 64 0100_0000_000b 40_00h Revision 1.2 (10-08-09) 44 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.3 Temperature Data Format (continued) 7.3 TEMPERATURE (°C) BINARY HEX (AS READ BY REGISTERS) 65 0100_0001_000b 41_00h 127 0111_1111_000b 7F_00h 127.875 0111_1111_111b 7F_E0h Critical/Thermal Shutdown Temperature Register Table 7.4 Critical/Thermal Shutdown Temperature Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 0Ah R Critical/Thermal Shutdown Temperature 128 64 32 16 8 4 2 1 7Fh (+127°C) The Critical/Thermal Shutdown Temperature Register is a read-only register that stores the Voltage Programmable Threshold temperature used in the Thermal / Critical Shutdown circuitry. The contents of the register reflect the calculated temperature determined by the voltage on the TRIP_SET pin (see Section 6.1.2, "SHDN_SEL Pin"). The data format is shown in Table 7.5, "Critical/Thermal Shutdown Data Format". Table 7.5 Critical/Thermal Shutdown Data Format 7.4 TEMPERATURE (°C) BINARY HEX 0 0000_0000b 00h 1 0000_0001b 01h 63 0011_1111b 3Fh 64 0100_0000b 40h 65 0100_0001b 41h 127 0111_1111b 7Fh Pushed Temperature Registers Table 7.6 Pushed Temperature Registers ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 0Ch R/W Pushed / Polled Temperature 1 Sign 64 32 16 8 4 2 1 00h 0Dh R/W Pushed / Polled Temperature 2 Sign 64 32 16 8 4 2 1 00h SMSC EMC2113 45 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet The Pushed Temperature Registers store user programmed temperature values or temperature values polled from one or more slave devices. This temperature can be used by the look-up table to update the fan control algorithm. Data written in these registers is not compared against any limits and must match the data format shown in Table 7.3, "Temperature Data Format". 7.5 PWM Input Duty Cycle Register Table 7.7 PWM Duty Cycle Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 0Fh R PWM Input Duty Cycle - 64 32 16 8 4 2 1 00h The PWM Input Duty Cycle register stores the calculated duty cycle of the signal on the PWM_IN pin. The value is stored as an 7-bit PWM setting ranging from 0 to 127 and represents the duty cycle as shown in Equation [1]. When used by the Fan Control Look Up Table (LUT), the 7-bit PWM Input Duty Cycle register setting is used as a temperature input and compared against the programmed thresholds. VALUE PWM Duty Cycle = ⎛ ---------------------⎞ × 100% ⎝ 128 ⎠ 7.6 [1] TRIP_SET Voltage Register Table 7.8 TRIP_SET Voltage Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 10h R TRIP_SET Voltage 750.0 375.0 187.5 93.75 46.88 23.43 11.72 5.86 FFh The TRIP_SET Voltage Register stores data that is measured on the TRIP_SET Voltage input. Each bit weight represents mV of resolution so that the final voltage can be determined by adding the weighting of the set bits together. 7.7 Ideality Factor Registers Table 7.9 Ideality Factor Registers ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 11h R/W External Diode 1 Ideality 0 0 0 1 0 B2 B1 B0 12h 12h R/W External Diode 2 Ideality 0 0 0 1 0 B2 B1 B0 12h 13h R/W External Diode 3 Ideality 0 0 0 1 0 B2 B1 B0 12h Revision 1.2 (10-08-09) 46 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet These registers store the ideality factors that are applied to the external diodes. Beta Compensation and Resistance Error Correction automatically correct for most diode ideality errors, therefore it is not recommended that these settings be updated without consulting SMSC. For CPU substrate transistors that require the BJT transistor model, the ideality factor behaves slightly differently than for discrete diode-connected transistors. Refer to Table 7.11, "Substrate Diode Ideality Factor Look-Up Table (BJT Model)" when using a CPU substrate transistor. Only the lower three bits can be written. Writing to any other bit will be ignored. The Ideality Factor Registers are software locked. Table 7.10 Ideality Factor Look-Up Table SETTING FACTOR 10h 1.0053 11h 1.0066 12h 1.0080 13h 1.0093 14h 1.0106 15h 1.0119 16h 1.0133 17h 1.0146 Table 7.11 Substrate Diode Ideality Factor Look-Up Table (BJT Model) SETTING FACTOR 10h 0.9973 11h 0.9986 12h 1.0000 13h 1.0013 14h 1.0026 15h 1.0039 16h 1.0053 17h 1.0066 APPLICATION NOTE: When measuring a 65nm Intel CPUs, the Ideality Setting should be the default 12h. When measuring 45nm Intel CPUs, the Ideality Setting should be 15h. SMSC EMC2113 47 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 7.8 Beta Configuration Register Table 7.12 Beta Configuration Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 14h R/W External Diode 1 Beta Configuration - - - AUT O1 - BETA1[2:0] 10h 15h R/W External Diode 2 Beta Configuration - - - AUT O2 - BETA2[2:0] 10h The Beta Configuration Register controls advanced temperature measurement features of the External Diode channels. If External Diode 1 is selected as the hardware shutdown measurement channel (see Section 6.1, "Critical/Thermal Shutdown") then the External Diode 1 Beta register will be read only. If the internal diode is selected, then this register can be written normally. Likewise, if the External Diode 2 channel is selected then this register can be written normally. Finally, if External Diode 2 is selected as the hardware shutdown measurement channel, then the External Diode 2 Beta Configuration Register will be read only. The External Diode 3 channel beta configuration will always be set at 07h (disabled / diode mode). Writing to a read only register will have no affect. The data will be ignored. Bit 4 - AUTOx - Enables the Automatic Beta detection algorithm for the External Diode X channel. ‘0’ - The Automatic Beta detection algorithm is disabled. The BETAx[2:0] bit settings will be used to control the beta compensation circuitry. ‘1’ (default) - The Automatic Beta detection algorithm is enabled. The circuitry will automatically detect the transistor type and beta values and configure the BETAx[2:0] bits for optimal performance. Bits 2 - 0 - BETAx[2:0] - hold a value that corresponds to a range of betas that the Beta Compensation circuitry can compensate for. These three bits will always show the current beta setting used by the circuitry. If the AUTO bit is set (default), then these bits may be overwritten with every temperature conversion. If the AUTO bit is not set, then the value of these bits is used to drive the beta compensation circuitry. In this case, these bits should be set with a value corresponding to the lowest expected value of beta for the PNP transistor being used as a temperature sensing device. See Table 7.13, "Beta Compensation Look Up Table" for supported beta ranges. A value of 111b indicates that the beta compensation circuitry is disabled. In this condition, the diode channels will function with default current levels and will not automatically adjust for beta variation. This mode is used when measuring a discrete 2N3904 transistor or AMD thermal diode. The Beta Configuration Registers are Software Locked. Table 7.13 Beta Compensation Look Up Table BETAX[2:0] 2 1 0 MINIMUM BETA 0 0 0 < 0.08 0 0 1 < 0.111 Revision 1.2 (10-08-09) 48 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.13 Beta Compensation Look Up Table (continued) BETAX[2:0] 7.9 2 1 0 MINIMUM BETA 0 1 0 < 0.176 0 1 1 < 0.29 1 0 0 < 0.48 1 0 1 < 0.9 1 1 0 < 2.33 1 1 1 Disabled REC Configuration Register Table 7.14 REC Configuration Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 17h R/W REC Configuration - - - - - REC3 REC2 REC1 07h The REC Configuration Register determines whether Resistance Error Correction is used for each external diode channel. Bit 2 - REC3 - Controls the Resistance Error Correction functionality of External Diode 3 ‘0’ - the REC functionality for External Diode 3 is disabled ‘1’ (default) - the REC functionality for External Diode 3 is enabled. Bit 1 - REC2 - Controls the Resistance Error Correction functionality of External Diode 2. ‘0’ - the REC functionality for External Diode 2 is disabled ‘1’ (default) - the REC functionality for External Diode 2 is enabled. Bit 0 - REC1 - Indicates the Resistance Error Correction functionality of External Diode 1. If External Diode 1 is selected as the hardware shutdown channel then this bit is read only. ‘0’ - the REC functionality for External Diode 1 is disabled ‘1’ (default) - the REC functionality for External Diode 1 is enabled. The REC Configuration Register is software locked. SMSC EMC2113 49 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 7.10 Critical Temperature Limit Registers Table 7.15 Limit Registers ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 19h R/W once External Diode 1 Tcrit Limit Sign 64 32 16 8 4 2 1 64h (+100°C) 1Ah R/W once External Diode 2 Tcrit Limit Sign 64 32 16 8 4 2 1 64h (+100°C) 1Bh R/W once External Diode 3 Tcrit Limit Sign 64 32 16 8 4 2 1 64h (+100°C) 1Dh R/W once Internal Diode Tcrit Limit Sign 64 32 16 8 4 2 1 64h (+100°C) The Critical Temperature Limit Registers store the Critical Temperature Limit. At power up, none of the respective channels are linked to the SYS_SHDN pin or the Hardware set Thermal/Critical Shutdown circuitry. Whenever one of the registers is updated, two things occur. First, the register is locked so that it cannot be updated again without a power on reset. Second, the respective temperature channel is linked to the SYS_SHDN pin and the Hardware set Thermal/Critical Shutdown Circuitry. At this point, if the measured temperature channel meets or exceeds the critical limit, the SYS_SHDN pin will be asserted, the appropriate bit set in the Tcrit Status Register, and the TCRIT bit in the Interrupt Status Register will be set. 7.11 Configuration Register Table 7.16 Configuration Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 20h R/W Configuration MASK WD_EN - - SYS3 SYS2 SYS1 APD 00h The Configuration Register controls the basic functionality of the EMC2113. The bits are described below. Bit 7 - MASK - Blocks the ALERT pin from being asserted. ‘0’ (default) - The ALERT pin is unmasked. If any bit in either status register is set, the ALERT pin will be asserted (unless individually masked via the Mask Register) ‘1’ - The ALERT pin is masked and will not be asserted. Bit 6 - WD_EN - Enables the Watchdog timer to operate in Continuous Mode. ‘0’ (default) - The Watchdog timer does not operate continuously. It will function upon power up and at no other time. ‘1’ - The Watchdog timer operates continuously as described in Section 6.10.2, "Continuous Operation". Bit 3 - SYS3 - Enables the high temperature limit for the External Diode 3 channel to trigger the Critical/Thermal Shutdown circuitry (see Section 6.1, "Critical/Thermal Shutdown"). ‘0’ (default) - the External Diode 3 channel high limit will not be linked to the SYS_SHDN pin. If the temperature meets or exceeds the limit, the ALERT pin will be asserted normally. Revision 1.2 (10-08-09) 50 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet ‘1’ - the External Diode 3 channel high limit will be linked to the SYS_SHDN pin. If the temperature meets or exceeds the limit then the SYS_SHDN pin will be asserted. The SYS_SHDN pin will be released when the temperature drops below the high limit. The ALERT pin will be asserted normally. Bit 2 - SYS2 - Enables the high temperature limit for the External Diode 2 channel to trigger the Critical/Thermal Shutdown circuitry (see Section 6.1). ‘0’ (default) - the External Diode 2 channel high limit will not be linked to the SYS_SHDN pin. If the temperature meets or exceeds the limit, the ALERT pin will be asserted normally. ‘1’ - the External Diode 2 channel high limit will be linked to the SYS_SHDN pin. If the temperature meets or exceeds the limit then the SYS_SHDN pin will be asserted. The ALERT pin will be asserted normally. Bit 1 - SYS1 - Enables the high temperature limit for the External Diode 1 channel to trigger the Critical/Thermal Shutdown circuitry (see Section 6.1). ‘0’ (default) - The External Diode 1 channel high limit will not be linked to the SYS_SHDN pin. If the temperature meets or exceeds the limit, the ALERT pin will be asserted normally. ‘1’ - The External Diode 1 channel high limit will be linked to the SYS_SHDN pin. If the temperature meets or exceeds the limit then the SYS_SHDN pin will be asserted. The ALERT pin will be asserted normally. Bit 0 - APD - This bit enables the Anti-parallel diode functionality on the External Diode 3 pins (DP3 and DN3). ‘0’ (default) - The Anti-parallel diode functionality is disabled. The External Diode 2 channel can be configured for any type of diode ‘1’ - The Anti-parallel diode functionality is enabled. Both the External Diode 2 and 3 channels are configured to support a diode or diode connected transistor (such as a 2N3904). APPLICATION NOTE: When the APD diode is enabled, there will be a delay of a full temperature update before any comparisons and functionality associated with the External Diode 3 channel will be implemented. This includes the SYS3 bit operation, limit comparisons, and look up table comparisons. The Configuration Register is software locked. 7.12 Configuration 2 Register Table 7.17 Configuration 2 Register ADDR R/W REGISTER B7 B6 B5 B4 21h R/W Config 2 - DIS_ DYN DIS_ TO DIS_ AVG B3 B2 QUEUE[1:0] B1 B0 CONV[1:0] DEFAULT 0Eh The Configuration 2 Register controls conversion rate of the temperature monitoring as well as the fault queue. Bit 6 - DIS_DYN - Disables the Dynamic Averaging Feature. ‘0’ (default) - The Dynamic Averaging function is enabled. The conversion time for all temperature channels is scaled based on the chosen conversion rate to maximize accuracy and immunity to random temperature measurement variation. ‘1’ - The Dynamic Averaging function is disabled. The conversion time for all temperature channels is fixed regardless of the chosen conversion rate. SMSC EMC2113 51 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Bit 5 - DIS_TO - Disables the SMBus timeout function. ‘0’ (default) - The SMBus timeout function is enabled. ‘1’ - The SMBus timeout function is disabled allowing the device to be fully I2C compliant. Bit 4 - DIS_AVG - Disables digital averaging of the External Diode channels. ‘0’ (default) - The External Diode channels have digital averaging enabled. The temperature data is the average of the previous four measurements. ‘1’ - The External Diode channels have digital averaging disabled. The temperature data is the last measured data. Bits 3-2 - QUEUE[1:0] - Determines the number of consecutive out of limit conditions that are necessary to trigger an interrupt. Each measurement channel has a separate fault queue associated with the high limit, low limit, and diode fault condition. APPLICATION NOTE: If the fault queue for any channel is currently active (i.e. an out of limit condition has been detected and caused the fault queue to increment) then changing the settings will not take effect until the fault queue is zeroed. This occurs by the ALERT pin asserting or the out of limit condition being removed. Table 7.18 Fault Queue QUEUE[1:0] 1 0 NUMBER OF CONSECUTIVE OUT OF LIMIT CONDITIONS 0 0 1 (disabled) 0 1 2 1 0 3 1 1 4 (default) Bit 1 - 0 - CONV[1:0] - determines the conversion rate of the temperature monitoring. This conversion rate does not affect the fan driver. The supply current from VDD_3V is nominally dependent upon the conversion rate and the average current will increase as the conversion rate increases. Table 7.19 Conversion Rate CONV[1:0] 1 0 CONVERSION RATE 0 0 1 / sec 0 1 2 / sec 1 0 4 / sec (default) 1 1 Continuous The Configuration 2 Register is software locked. Revision 1.2 (10-08-09) 52 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 7.13 Interrupt Status Register Table 7.20 Interrupt Status Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 23h R Interrupt Status Register PWM - TCRIT - FAN HIGH LOW FAULT 00h The Interrupt Status Register reports the operating condition of the EMC2113. If any of the bits are set to a logic ‘1’ (other than TCRIT) then the ALERT pin will be asserted low if the corresponding channel is enabled. Reading from the status register clears the PWM bit. The other bits are cleared automatically when the corresponding register is read. If there are no set status bits, then the ALERT pin will be released. The bits that cause the ALERT pin to be asserted can be masked based on the channel they are associated with unless stated otherwise. Bit 7 - PWM - This bit indicates that the PWM input duty cycle (on the PWM pin) meets or exceeds the high limit. This bit is cleared when the register is read. Bit 5 - TCRIT - This bit is set to ‘1’ if any bit in the Tcrit Status Register is set. This bit is automatically cleared when the Tcrit Status Register is read and the bits are cleared. Bit 3 - FAN - This bit is set to ‘1’ if any bit in the Fan Status Register is set. This bit is automatically cleared when the Fan Status Register is read and the bits are cleared. Bit 2 - HIGH - This bit is set to ‘1’ if any bit in the High Status Register is set. This bit is automatically cleared when the High Status Register is read and the bits are cleared. Bit 1- LOW - This bit is set to ‘1’ if any bit in the Low Status Register is set. This bit is automatically cleared when the Low Status Register is read and the bits are cleared. Bit 0 - FAULT - This bit is set to ‘1’ if any bit in the Diode Fault Register is set. This bit is automatically cleared when the Diode Fault Register is read and the bits are cleared. 7.14 Error Status Registers Table 7.21 Error Status Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 1Fh R-C Tcrit Status HWS - - - EXT3_ TCRIT EXT2_ TCRIT EXT1_ TCRIT INT_ TCRIT 00h 24h R-C High Status - - - - EXT3_ HI EXT2_ HI EXT1_ HI INT_HI 00h 25h R-C Low Status - - - - EXT3_ LO EXT2_ LO EXT1_ LO INT_LO 00h 26h R-C Diode Fault - - - - EXT3_ FLT EXT2_ FLT EXT1_ FLT - 00h The Error Status Registers report the specific error condition for all measurement channels with limits. If any bit is set in the High, Low, or Diode Fault Status register, the corresponding High, Low, or Fault bit is set in the Interrupt Status Register. SMSC EMC2113 53 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Reading the Interrupt Status Register does not clear the Error Status bit. Reading from any Error Status Register that has bits set will clear the register and the corresponding bit in the Interrupt Status Register if the error condition has been removed. If the error condition is persistent, reading the Error Status Registers will have no effect. 7.14.1 Tcrit Status Register The Tcrit Status Register stores which software enabled temperature channel has caused the SYS_SHDN pin to be asserted. Each of the temperature channels must be associated with the SYS_SHDN pin before they can be set (see Section 7.10, "Critical Temperature Limit Registers"). Once the SYS_SHDN pin is asserted, it will be released when the temperature drops below the threshold level; however, the individual status bit will not be cleared until read. Bit 7 - HWS - This bit is set if the hardware set temperature channel caused the SYS_SHDN pin to be asserted. 7.15 Fan Status Register Table 7.22 Fan Status Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 27h R-C Fan Status Register WATCH - DRIVE_ FAIL - - - FAN_ SPIN FAN_ STALL 00h The Fan Status Register contains the status bits associated with each fan driver. Bit 7 - WATCH - This bit is asserted ‘1’ if the Watchdog timer has expired (see Section 6.10, "Watchdog Timer"). Bit 5 - DRIVE_FAIL - Indicates that the RPM-based Fan Speed Control Algorithm cannot drive the Fan to the desired target setting at maximum drive. This bit can be masked from asserting the ALERT pin. ‘0’ - The RPM-based Fan Speed Control Algorithm can drive Fan to the desired target setting. ‘1’ - The RPM-based Fan Speed Control Algorithm cannot drive Fan to the desired target setting at maximum drive. Bit 1- FAN_SPIN - This bit is asserted ‘1’ if the Spin up Routine for the Fan cannot detect a valid tachometer reading within its maximum time window. This bit can be masked from asserting the ALERT pin. Bit 0 - FAN_STALL - This bit is asserted ‘1’ if the tachometer measurement on the Fan detects a stalled fan. This bit can be masked from asserting the ALERT pin. 7.16 Interrupt Enable Register Table 7.23 Interrupt Enable Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 28h R/W Interrupt Enable PWM_ INT_ EN - - - EXT3_ INT_ EN EXT2_ INT_ EN EXT1_ INT_ EN INT_ INT_ EN 00h The Interrupt Enable Register controls the masking for each temperature channel. When a channel is masked, it will not cause the ALERT pin to be asserted when an error condition is detected. Revision 1.2 (10-08-09) 54 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Bit 7 - PWM_INT_EN - Allows the PWM input to assert the ALERT pin. ‘0’ (default) - The ALERT pin will not be asserted if the PWM input duty cycle meets or exceeds its high limit. ‘1’ - The ALERT pin will be asserted if the PWM input duty cycle meets or exceeds its high limit. Bit 3 - EXT3_INT_EN - Allows the External Diode 3 to assert the ALERT pin. ‘0’ (default) - The ALERT pin will not be asserted for any error condition associated with External Diode 3 channel. ‘1’ - The ALERT pin will be asserted for an error condition associated with External Diode 3 channel. Bit 2 - EXT2_INT_EN - Allows the External Diode 2 to assert the ALERT pin. ‘0’ (default) - The ALERT pin will not be asserted for any error condition associated with External Diode 2 channel. ‘1’ - The ALERT pin will be asserted for an error condition associated with External Diode 2 channel. Bit 1 - EXT1_INT_EN - Allows the External Diode 1 to assert the ALERT pin. ‘0’ (default) - The ALERT pin will not be asserted for any error condition associated with External Diode 1 channel. ‘1’ - The ALERT pin will be asserted for an error condition associated with External Diode 1 channel. Bit 0 - INT_INT_EN - Allows the Internal Diode to assert the ALERT pin. 7.17 ‘0’ (default) - The ALERT pin will not be asserted for any error condition associated with the Internal Diode. ‘1’ - The ALERT pin will be asserted for an error condition associated with the Internal Diode. Fan Interrupt Enable Register Table 7.24 Fan Interrupt Enable Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 29h R/W Fan Interrupt Enable - - - - - - SPIN_ INT_EN STALL_ INT_EN 00h The Fan Interrupt Enable Register controls the masking for errors generated by the Fan Driver. When a channel is masked, it will not cause the ALERT pin to be asserted when an error condition is detected. Bit 1 - SPIN_INT_EN - Allows the FAN_SPIN bit to assert the ALERT pin. ‘0’ (default) - the FAN_SPIN bit will not assert the ALERT pin though it will still update the Status Register normally. ‘1’ - the FAN_SPIN bit will assert the ALERT pin. Bit 0 - STALL_INT_EN - Allows the FAN_STALL bit or DRIVE_FAIL bit to assert the ALERT pin. ‘0’ (default) - the FAN_STALL bit or DRIVE_FAIL bit will not assert the ALERT pin though will still update the Status Register normally. ‘1’ - the FAN_STALL bit will assert the ALERT pin. SMSC EMC2113 55 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 7.18 PWM Driver Configuration Register Table 7.25 PWM Driver Configuration Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 2Ah R/W PWM Driver Config - - - PWM_ OT - - - POLARITY 00h The PWM Driver Configuration Register controls the output type and polarity of the PWM fan drive output. Bit 4 - PWM_OT - Determines the output type for the PWM pin. ‘0’ (default) - The PWM pin is configured as an open drain output. ‘1’ - The PWM pin is configured as a push-pull output. Bit 0 - POLARITY - Determines the polarity of the PWM pin. 7.19 ‘0’ (default) - the Polarity of the PWM output driver is normal. A drive setting of 00h will cause the output to be set at 0% duty cycle and a drive setting of FFh will cause the output to be set at 100% duty cycle. ‘1’ - The Polarity of the PWM output driver is inverted. A drive setting of 00h will cause the output to be set at 100% duty cycle and a drive setting of FFh will cause the output to be set at 0% duty cycle. PWM Driver Base Frequency Register Table 7.26 PWM Driver Base Frequency Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 2Bh R/W PWM Driver Base Frequency - - - - - - B1 B0 DEFAULT PWM_BASE[1:0] 00h The PWM Driver Base Frequency Register controls base frequency of the PWM driver output. Bits 1-0 - PWM_BASE[1:0] - Determines the base frequency of the PWM output driver. Table 7.27 PWM_BASEx[1:0] it Decode PWM_BASE[1:0] 1 0 BASE FREQUENCY 0 0 26.00kHz (default) 0 1 19.531kHz 1 0 4,882Hz 1 1 2,441Hz Revision 1.2 (10-08-09) 56 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 7.20 Limit Registers Table 7.28 Limit Registers ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 30h R/W External Diode 1 High Limit Sign 64 32 16 8 4 2 1 55h (+85°C) 31h R/W External Diode 2 High Limit Sign 64 32 16 8 4 2 1 55h (+85°C) 32h R/W External Diode 3 High Limit Sign 64 32 16 8 4 2 1 55h (+85°C) 34h R/W Internal Diode High Limit Sign 64 32 16 8 4 2 1 55h (+85°C) 38h R/W External Diode 1 Low Limit Sign 64 32 16 8 4 2 1 00h (0°C) 39h R/W External Diode 2 Low Limit Sign 64 32 16 8 4 2 1 00h (0°C) 3Ah R/W External Diode 3 Low Limit Sign 64 32 16 8 4 2 1 00h (0°C) 3Ch R/W Internal Diode Low Limit Sign 64 32 16 8 4 2 1 00h (0°C) The EMC2113 contains high limits for all temperature channels. If any measurement meets or exceeds the high limit then the appropriate status bit is set and the ALERT pin is asserted (if enabled). Additionally, the EMC2113 contains low limits for all temperature channels. If the temperature channel drops below the low limit, then the appropriate status bit is set and the ALERT pin is asserted (if enabled). All Limit Registers are Software Locked. 7.21 PWM Input Duty Cycle High Limit Register Table 7.29 PWM Duty Cycle High Limit Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 3Dh R/W PWM Input Duty Cycle High Limit - 64 32 16 8 4 2 1 7Fh The PWM Duty Cycle High Limit register stores a high limit on the Duty Cycle input on the PWM pin. The data format for the register is the same as the PWM Input Duty Cycle register (see Section 7.5, "PWM Input Duty Cycle Register") and it is compared at the sampling rate of the PWM Input duty cycle. If the PWM Input Duty Cycle meets or exceeds this limit, then the PWM status bit is set (see Section 7.13, "Interrupt Status Register") and the ALERT pin is asserted. This is treated as a temperature limit by the Fan Control circuitry. SMSC EMC2113 57 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 7.22 Fan Setting Registers Table 7.30 Fan Driver Setting Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 40h R/W Fan Setting 128 64 32 16 8 4 2 1 00h The Fan Setting Register always displays the current setting of the Fan Driver. Reading from the register will report the current fan speed setting of the fan driver regardless of the operating mode. Therefore it is possible that reading from this register will not report data that was previously written into this register. While the RPM-based Fan Speed Control Algorithm and/or the Look Up Table are active, then the register is read only. Writing to the register will have no effect and the data will not be stored. If both the RPM-based Fan Control Algorithm and the Look Up Table are disabled, then the register will be set with the previous value that was used. The register is read / write and writing to this register will affect the fan speed. The contents of the register represent the weighting of each bit in determining the final duty cycle. The output drive for a PWM output is given by Equation [2]. VALUE Drive = ⎛ ---------------------⎞ × 100% ⎝ 255 ⎠ 7.23 [2] PWM Divide Register Table 7.31 PWM Divide Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 41h R/W PWM Divide 128 64 32 16 8 4 2 1 01h The PWM Divide Register determines the final frequency of the PWM driver. The driver base frequency is divided by the value of the PWM Divide Register to determine the final frequency. The duty cycle settings are not affected by these settings, only the final frequency of the PWM driver. A value of 00h will be decoded as 01h. The final PWM frequency is derived as the base frequency divided by the value of this register as shown in Equation [3]. PWM base freqeuncy f PWM = --------------------------------------------------------------PWM Divide Setting 7.24 [3] Fan Configuration 1 Register Table 7.32 Fan Configuration 1 Register ADDR R/W REGISTER B7 42h R/W Fan Configuration 1 EN_ ALGO Revision 1.2 (10-08-09) B6 B5 RANGE[1:0] B4 B3 EDGES[1:0] 58 DATASHEET B2 B1 B0 UPDATE[2:0] DEFAULT 2Bh SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet The Fan Configuration 1 Register controls the general operation of the RPM-based Fan Speed Control Algorithm used on the PWM pin. Bit 7 - EN_ALGO - enables the RPM-based Fan Speed Control Algorithm. Based on the setting of the RPM / PWM bit, this bit is automatically set or cleared when the LUT_LOCK bit is set (see Section 7.34, "Look Up Table Configuration Register"). ‘0’ - (default) the control circuitry is disabled and the fan driver output is determined by the Fan Driver Setting Register. ‘1’ - the control circuitry is enabled and the Fan Driver output will be automatically updated to maintain the programmed fan speed as indicated by the TACH Target Register. Bits 6- 5 - RANGE[1:0] - Adjusts the range of reported and programmed tachometer reading values. The RANGE bits determine the weighting of all TACH values (including the Valid TACH Count, TACH Target, and TACH reading) as shown in Table 7.33, "Range Decode". Table 7.33 Range Decode RANGE[1:0] 1 0 REPORTED MINIMUM RPM TACH COUNT MULTIPLIER 0 0 500 1 0 1 1000 (default) 2 1 0 2000 4 1 1 4000 8 Bits 4-3 - EDGES[1:0] - determines the minimum number of edges that must be detected on the TACH signal to determine a single rotation. A typical fan measured 5 edges (for a 2-pole fan). For more accurate tachometer measurement, the minimum number of edges measured may be increased. Increasing the number of edges measured with respect to the number of poles of the fan will cause the TACH Reading registers to indicate a fan speed that is higher or lower than the actual speed. In order for the FSC Algorithm to operate correctly, the TACH Target must be updated by the user to accommodate this shift. The Effective Tach Multiplier shown in Table 7.34, "Minimum Edges for Fan Rotation" is used as a direct multiplier term that is applied to the Actual RPM to achieve the Reported RPM. It should only be applied if the number of edges measured does not match the number of edges expected based on the number of poles of the fan (which is fixed for any given fan). Contact SMSC for recommended settings when using fans with more or less than 2 poles. Table 7.34 Minimum Edges for Fan Rotation EDGES[1:0] EFFECTIVE TACH MULTIPLIER (BASED ON 2 POLE FANS) 1 0 MINIMUM TACH EDGES 0 0 3 1 pole 0 1 5 2 poles (default) 1 0 7 3 poles 1.5 1 1 9 4 poles 2 NUMBER OF FAN POLES 0.5 1 Bit 2-0 - UPDATE - determines the base time between fan driver updates. The Update Time, along with the Fan Step Register, is used to control the ramp rate of the drive response to provide a cleaner SMSC EMC2113 59 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet transition of the actual fan operation as the desired fan speed changes. The Update Time is set as shown in Table 7.35. Table 7.35 Update Time UPDATE[2:0] 7.25 2 1 0 UPDATE TIME 0 0 0 100ms 0 0 1 200ms 0 1 0 300ms 0 1 1 400ms (default) 1 0 0 500ms 1 0 1 800ms 1 1 0 1200ms 1 1 1 1600ms Fan Configuration 2 Register Table 7.36 Fan Configuration 2 Register ADDR R/W REGISTER B7 B6 B5 43h R/W Fan Configuration 2 TEMP_ RR EN_ RRC GLITCH_ EN B4 B3 DER_OPT [1:0] B2 B1 ERR_RNG:0] B0 DEFAULT - 28h The Fan Configuration 2 Register controls the tachometer measurement and advanced features of the RPM-based Fan Speed Control Algorithm. Bit 7 - TEMP_RR - Overrides max step controls for the FSC algorithm when any temperature exceeds its respective high limit. ‘0’ (default) - All ramp rate control circuitry works at all times for the FSC algorithm or as determined by the EN_RRC bit for manual mode. ‘1’ - If any measured temperature or the PWM Input Duty cycle meets or exceeds its respective high limit, then the Fan Max Step register settings are not used and the FSC algorithm acts as if the Max Step settings were at 3Fh. The device will continue to operate in this way until all temperatures (and the PWM input duty cycle) have dropped below the respective high limit. Bit 6 - EN_RRC - Enables ramp rate control when the fan driver is operated in the Direct Setting mode or the Direct Setting with LUT mode. ‘0’ (default) - Ramp rate control is disabled. When the fan driver is operating in Direct Setting mode or Direct Setting with LUT mode, the PWM setting will instantly transition to the next programmed setting. ‘1’ - Ramp rate control is enabled. When the fan driver is operating in Direct Setting mode or Direct Setting with LUT mode, the PWM setting will follow the ramp rate controls as determined by the Fan Step and Update Time settings. The maximum PWM step is capped at the Fan Step setting and is updated based on the Update Time as given by Table 7.35. Revision 1.2 (10-08-09) 60 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Bit 5 - GLITCH_EN - Disables the low pass glitch filter that removes high frequency noise injected on the TACH pin. ‘0’ - The glitch filter is disabled. ‘1’ (default) - The glitch filter is enabled. Bits 4 - 3 - DER_OPT[1:0] - Control some of the advanced options that affect the derivative portion of the RPM-based Fan Speed Control Algorithm as shown in Table 7.37, "Derivative Options". Table 7.37 Derivative Options DER_OPT[1:0] 1 0 OPERATION 0 0 No derivative terms used 0 1 Basic derivative. The derivative of the error from the current drive setting and the target is added to the iterative Fan Drive setting (in addition to proportional and integral terms - default) 1 0 Step derivative. The derivative of the error from the current drive setting and the target is added to the iterative Fan Drive setting and is not capped by the maximum Fan Step Register setting. 1 1 Both the basic derivative and the step derivative are used effectively causing the derivative term to have double the effect of the derivative term. Bit 2 - 1 - ERR_RNG[1:0] - Control some of the advanced options that affect the error window. When the measured fan speed is within the programmed error window around the target speed, then the fan drive setting is not updated. The algorithm will continue to monitor the fan speed and calculate necessary drive setting changes based on the error; however, these changes are ignored. Table 7.38 Error Range Options ERR_RNG[1:0] 1 0 OPERATION 0 0 0 RPM (default) 0 1 50 RPM 1 0 100 RPM 1 1 200 RPM The Fan Configuration 2 Register is Software Locked. SMSC EMC2113 61 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 7.26 Gain Register Table 7.39 Gain Register ADDR R/W REGISTER B7 B6 45h R/W Gain Register - - B5 B4 GAIND[1:0] B3 B2 GAINI[1:0] B1 B0 DEFAULT GAINP[1:0] 2Ah The Gain Register stores the gain terms used by the proportional and integral portions of the RPMbased Fan Speed Control Algorithm. These terms will affect the FSC closed loop acquisition, overshoot, and settling as would be expected in a classic PID system. Table 7.40 Gain Decode GAIND OR GAINP OR GAINI [1:0] 7.27 1 0 RESPECTIVE GAIN FACTOR 0 0 1x 0 1 2x 1 0 4x (default) 1 1 8x Fan Spin Up Configuration Register Table 7.41 Fan Spin Up Configuration Register ADDR R/W REGISTER B7 46h R/W Fan Spin Up Configuration B6 DRIVE_FAIL_ CNT [1:0] B5 NOK ICK B4 B3 B2 SPIN_LVL[2:0] B1 B0 DEFAULT SPINUP_TIME [1:0] 19h The Fan Spin Up Configuration Register controls the settings of Spin Up Routine. Bit 7 - 6 - DRIVE_FAIL_CNT[1:0] - Determines how many update cycles are used for the Drive Fail detection function as shown in Table 7.42, "DRIVE_FAIL_CNT[1:0] Bit Decode". This circuitry determines whether the fan can be driven to the desired tach target. Table 7.42 DRIVE_FAIL_CNT[1:0] Bit Decode DRIVE_FAIL_CNT[1:0] 1 0 0 0 Disabled - the Drive Fail detection circuitry is disabled (default) 0 1 16 - the Drive Fail detection circuitry will count for 16 update periods Revision 1.2 (10-08-09) NUMBER OF UPDATE PERIODS 62 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.42 DRIVE_FAIL_CNT[1:0] Bit Decode (continued) DRIVE_FAIL_CNT[1:0] 1 0 NUMBER OF UPDATE PERIODS 1 0 32 - the Drive Fail detection circuitry will count for 32 update periods 1 1 64 - the Drive Fail detection circuitry will count for 64 update periods Bit 5 - NOKICK - Determines if the Spin Up Routine will drive the fan to 100% duty cycle for 1/4 of the programmed spin up time before driving it at the programmed level. ‘0’ (default) - The Spin Up Routine will drive the PWM to 100% for 1/4 of the programmed spin up time before reverting to the programmed spin level. ‘1’ - The Spin Up Routine will not drive the PWM to 100%. It will set the drive at the programmed spin level for the entire duration of the programmed spin up time. Bits 4 - 2 - SPIN_LVL[2:0] - Determines the final drive level that is used by the Spin Up Routine as shown in Table 7.43, "Spin Level". Table 7.43 Spin Level SPIN_LVL[2:0] 2 1 0 SPIN UP DRIVE LEVEL 0 0 0 30% 0 0 1 35% 0 1 0 40% 0 1 1 45% 1 0 0 50% 1 0 1 55% 1 1 0 60% (default) 1 1 1 65% Bit 1 -0 - SPINUP_TIME[1:0] - determines the maximum Spin Time that the Spin Up Routine will run for (see Section 6.8, "Spin Up Routine"). If a valid tachometer measurement is not detected before the Spin Time has elapsed, then an interrupt will be generated. When the RPM-based Fan Speed Control Algorithm is active, the fan driver will attempt to re-start the fan immediately after the end of the last spin up attempt. The Spin Time is set as shown in Table 7.44. SMSC EMC2113 63 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.44 Spin Time SPINUP_TIME[1:0] 1 0 TOTAL SPIN UP TIME 0 0 250 ms 0 1 500 ms (default) 1 0 1 sec 1 1 2 sec The Fan Spin Up Configuration Register is software locked. 7.28 Fan Step Register Table 7.45 Fan Step Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 47h R/W Fan Max Step - - 32 16 8 4 2 1 10h The Fan Step Register, along with the Update Time, control the ramp rate of the fan driver response. The value of the registers represents the maximum step size each fan driver will take between update times (see Section 7.24, "Fan Configuration 1 Register"). All modes of operation have the options to use the Fan Step Register (and update times) for ramp rate control based on the Fan Configuration 2 Register settings. The Fan Speed Control Algorithm will always use the Fan Step Register settings (but see application note below). The Fan Step Register is software locked. 7.29 Fan Minimum Drive Register Table 7.46 Minimum Fan Drive Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 48h R/W Fan Minimum Drive 128 64 32 16 8 4 2 1 66h (40%) The Fan Minimum Drive Register stores the minimum drive setting for the RPM-based Fan Speed Control Algorithm. This register is not used if the FSC is not active. The RPM-based Fan Speed Control Algorithm will not drive the fan at a level lower than the minimum drive unless the target TACH Target is set at FFh. (See Section 7.32, "TACH Target Register".) During normal operation, if the fan stops for any reason (including low drive), the RPM-based Fan Speed Control Algorithm will attempt to restart the fan. Setting the Fan Minimum Drive Registers to a setting that will maintain fan operation is a useful way to avoid potential fan oscillations as the control circuitry attempts to drive it at a level that cannot support fan operation. The Fan Minimum Drive Register is software locked. Revision 1.2 (10-08-09) 64 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 7.30 Valid TACH Count Register Table 7.47 Valid TACH Count Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 49h R/W Valid TACH Count 4096 2048 1024 512 256 128 64 32 F5h The Valid TACH Count Register store the maximum TACH Reading Register value to indicate that the the fan is spinning properly. The value is referenced at the end of the Spin Up Routine to determine if the fan has started operating and decide if the device needs to retry. See Equation [5] for translating the count to an RPM. If the TACH Reading Register value exceeds the Valid TACH Count Register (indicating that the Fan RPM is below the threshold set by this count), then a stalled fan is detected. In this condition, the algorithm will automatically begin its Spin Up Routine. APPLICATION NOTE: The automatic invoking of the Spin Up Routine only applies if the Fan Speed Control Algorithm is used. If the FSC is disabled, then the device will only invoke the Spin Up Routine when the PWM setting changes from 00h. If a TACH Target setting is set above the Valid TACH Count setting, then that setting will be ignored and the algorithm will use the current fan drive setting. The Valid TACH Count Register is software locked. 7.31 Fan Drive Fail Band Registers Table 7.48 Fan Drive Fail Band Registers ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 4Ah R/W Fan Drive Fail Band Low Byte 16 8 4 2 1 - - - 00h 4Bh R/W Fan Drive Fail Band High Byte 4096 2048 1024 512 256 128 64 32 00h The Fan Drive Fail Band Registers store the number of tach counts used by the Fan Drive Fail detection circuitry. This circuitry is activated when the fan drive setting high byte is at FFh. When it is enabled, the actual measured fan speed is compared against the target fan speed. This circuitry is used to indicate that the target fan speed at full drive is higher than the fan is actually capable of reaching. If the measured fan speed does not exceed the target fan speed minus the Fan Drive Fail Band Register settings for a period of time longer than set by the DRIVE_FAIL_CNTx[1:0] bits then the DRIVE_FAIL status bit will be set and an interrupt generated. SMSC EMC2113 65 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 7.32 TACH Target Register Table 7.49 TACH Target Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 4Ch R/W Fan TACH Target Low Byte 16 8 4 2 1 - - - F8h 4Dh R/W TACH Target 4096 2048 1024 512 256 128 64 32 FFh The TACH Target Register holds the target tachometer value that is maintained by the RPM-based Fan Speed Control Algorithm. The value in the TACH Target Register will always reflect the current TACH Target value. If the Look Up Table is active and configured to operate in RPM Mode, then this register will be read only. Writing to this register will have no affect and the data will not be stored. If the algorithm is enabled then setting the TACH Target Register to FFh will disable the fan driver (set the PWM duty cycle to 0%). Setting the TACH Target to any other value (from a setting of FFh) will cause the algorithm to invoke the Spin Up Routine after which it will function normally. 7.33 TACH Reading Register Table 7.50 TACH Reading Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 4Eh R Fan TACH 4096 2048 1024 512 256 128 64 32 FFh 4Fh R Fan TACH Low Byte 16 8 4 2 1 - - - F8h The TACH Reading Register contents describe the current tachometer reading for the fan. By default, the data represents the fan speed as the number of 32kHz clock periods that occur for a single revolution of the fan. Equation [4] shows the detailed conversion from TACH measurement (COUNT) to RPM while Equation [5] shows the simplified translation of TACH Reading Register count to RPM assuming a 2-pole fan, measuring 5 edges, with a frequency of 32.768kHz. These equations are solved and tabulated for ease of use in AN17.4 RPM to TACH Counts Conversion. Revision 1.2 (10-08-09) 66 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet where: poles = number of poles of the fan (typically 2) 1 (n – 1) RPM = -------------------- × ---------------------------------- × 1,966,080 ( poles ) 1 COUNT × ----m n = number of edges measured (typically 5) m = the multiplier defined by the RANGE bits 3,932,160 × m RPM = -------------------------------------COUNT 7.34 [4] [5] COUNT = TACH Reading Register value (in decimal) Look Up Table Configuration Register Table 7.51 Look Up Table Configuration Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT R/W LUT Configuration USE_ DTS_P1 USE_ DTS_P2 LUT LOCK RPM / PWM PUSH1_ CFG TEMP1_ CFG TEMP3_ CFG TEMP4_ CFG 00h 50h 7Dh The Look Up Table Configuration Register controls the setup information for the temperature to fan drive look up table. APPLICATION NOTE: This register is duplicated at 50h as well as 7Dh for ease of programming using block write mode. Example: Set register 50h to unlock the table and register 7Dh to lock the table. The External Diode 2 channel is always used as the Temperature 2 input to the Fan Control Look Up Table. Bit 7 - USE_DTS_P1 - This bit determines whether the Pushed Temperature 1 Register is using DTS data. ‘0’ (default) - The Pushed Temperature 1 Register is not using DTS data. The contents of the Pushed Temperature 1 registers are standard temperature data. ‘1’ - The Pushed Temperature 1 Register is loaded with DTS data. The contents of this register are automatically subtracted from a fixed value of 100°C before being compared to the Look Up Table threshold levels. Bit 6 - USE_DTS_P2 - This bit determines whether the Pushed Temperature 2 Register is using DTS data. ‘0’ (default) - The Pushed Temperature 2 Register is not using DTS data. The contents of this register are standard 2’s complement temperature data. ‘1’ - The Pushed Temperature 2 Register is loaded with DTS data. The contents of this register are automatically subtracted from a fixed value of 100°C before being compared to the Look Up Table threshold levels. Bit 5 - LUT_LOCK - This bit locks updating the Look Up Table entries and determines whether the look up table is being used. SMSC EMC2113 ‘0’ (default) - The Look Up Table entries can be updated normally. The Look Up Table will not be used while the Look Up Table entries are unlocked. During this condition, the PWM output will not change states regardless of temperature or tachometer variation. 67 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet ‘1’ - The Look Up Table entries are locked and cannot be updated. The Look Up Table is fully active and will be used based on the loaded values. The PWM output will be updated depending on the temperature and / or TACH variations. APPLICATION NOTE: When the LUT_LOCK bit is set at a logic ‘0’, the PWM drive setting will be set at whatever value was last used by the RPM-based Fan Speed Control Algorithm or the Look Up Table. Bit 4 - RPM / PWM - This bit selects the data format for the LUT drive settings. ‘0’ (default) - The Look Up Table drive settings are RPM TACH count values for use by the RPMbased Fan Speed Control Algorithm. The Look Up Table drive settings should be loaded highest value to lowest value (to coincide with the inversion between TACH counts and actual RPM). ‘1’ - The Look Up Table drive settings are PWM duty cycle values and are used directly. The drive settings should be loaded lowest value to highest value. Bit 3 - PUSH1_CFG - Determines whether the PWM Input duty cycle is used instead of the Pushed 1 Temperature data when the TEMP1_CFG bit is set. ‘0’ (default) - The Pushed Temperature 1 register can be written via the SMBus and will hold a temperature value. The PWM Input Duty cycle is not used. ‘1’ - If the TEMP1_CFG or TEMP3_CFG bit is set, the PWM Input Duty cycle will be used. The Pushed Temperature 1 register can be written via the SMBus and will hold a temperature value but will not be used. APPLICATION NOTE: If the Pushed Temperature 1 data is configured to hold the PWM input duty cycle and is used in the Look Up Table, then the Look Up Table threshold levels must be programmed in the same format as the PWM input duty cycle - see Section 7.5 and Section 7.35. Bit 2 - TEMP1_CFG - Determine the temperature channel that is used for the Temperature 1 inputs to the Look Up Table. ‘0’ (default) - The External Diode 1 channel is used by the Fan Look Up Table. ‘1’ - Either the data written into the Pushed Temperature 1 Register or the data in the PWM Input Duty Cycle register is used by the Fan Look Up table as determined by the PUSH1_CFG bit. Bit 1 - TEMP3_CFG - Determine the temperature channel that is used for the Temperature 3 inputs to the Look Up Table. ‘0’ (default) - The External Diode 3 channel is used by the Fan Look Up Table (if enabled). ‘1’ - Either the data written into the Pushed Temperature 1 Register or the data in the PWM Input Duty Cycle register is used by the Fan Look Up table as determined by the PUSH1_CFG bit. Bit 0 - TEMP4_CFG - Determine the temperature channel that is used for the Temperature 4 inputs to the Look Up Table. 7.35 ‘0’ (default) -The Internal diode channel is used by the Fan Look Up Table. ‘1’ - The data written into the Pushed Temperature 2 Register is used by the Fan Look Up Table. Look Up Table Registers Table 7.52 Look Up Table Registers ADDR R/W REGISTER 51h R/W LUT Drive Setting 1 Revision 1.2 (10-08-09) RPM / PWM B7 B6 B5 B4 B3 B2 B1 B0 ‘0’ 4096 2048 1024 512 256 128 64 32 ‘1’ 128 64 32 16 8 4 2 1 DEFAULT FBh 68 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.52 Look Up Table Registers (continued) RPM / PWM B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT LUT Temp 1 Setting 1 X - 64 32 16 8 4 2 1 7Fh (127°C) R/W LUT Temp 2 Setting 1 X - 64 32 16 8 4 2 1 7Fh (127°C) 54h R/W LUT Temp 3 Setting 1 X - 64 32 16 8 4 2 1 7Fh (127°C) 55h R/W LUT Temp 4 Setting 1 X - 64 32 16 8 4 2 1 7Fh (127°C) ... ... ... ... ... ... ... ... ... ... ... ... ... 4096 2048 1024 512 256 128 64 32 R/W LUT Drive Setting 8 ‘0’ 74h ‘1’ 128 64 32 16 8 4 2 1 ADDR R/W REGISTER 52h R/W 53h 92h 75h R/W LUT Temp 1Setting 8 X - 64 32 16 8 4 2 1 7Fh (127°C) 76h R/W LUT Temp 2 Setting 8 X - 64 32 16 8 4 2 1 7Fh (127°C) 77h R/W LUT Temp 3 Setting 8 X - 64 32 16 8 4 2 1 7Fh (127°C) 78h R/W LUT Temp 4 Setting 8 X - 64 32 16 8 4 2 1 7Fh (127°C) 79h R/W LUT Temp 1 Hysteresis X - - - 16 8 4 2 1 0Ah (10°C) 7Ah R/W LUT Temp 2 Hysteresis X - - - 16 8 4 2 1 0Ah (10°C) 7Bh R/W LUT Temp 3 Hysteresis X - - - 16 8 4 2 1 0Ah (10°C) 7Ch R/W LUT Temp 4 Hysteresis X - - - 16 8 4 2 1 0Ah (10°C) The Look Up Table Registers hold the 40 entries of the Look Up Table that control the drive of the PWM. As the temperature channels are updated, the measured value for each channel is compared against the respective entries in the Look Up Table and the associated drive setting is loaded into an internal shadow register and stored. The bit weighting for temperature inputs represents °C and is compared against the measured data. Note that the LUT entry does not include a sign bit. The Look Up Table does not support negative temperature values and the MSBit should not be set for a temperature input. APPLICATION NOTE: When the PWM Input Duty cycle values are used, then the bit weighting represents a unitless threshold that does not corresponded to specific temperature values. It is used to drive the fan speed based on external temperatures known to a separate microcontroller driving the PWM_IN pin. Each temperature channel threshold for a single “column” shares the same hysteresis value; however, each temperature input has a different hysteresis value. When the measured temperature for any of the channels meets or exceeds the programmed threshold, the drive setting associated with that threshold is used. The temperature must drop below the threshold minus the hysteresis value before the drive setting will be set to the previous value. SMSC EMC2113 69 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet If the RPM-based Fan Speed Control Algorithm is used, the TACH Target is updated after every conversion. It is always set to the minimum TACH Target that is stored by the Look Up Table. The PWM duty cycle is updated based on the RPM-based Fan Speed Control Algorithm configuration settings. If the RPM-based Fan Speed Control Algorithm is not used, then the output PWM duty cycle is updated after every conversion. It is set to the maximum duty cycle that is stored by the Look Up Table. If the measured temperature reading on all channels is less than the lowest threshold setting minus the appropriate hysteresis setting, then the Fan driver will be set to 0% duty cycle and the fan will be disabled. 7.36 Software Lock Register Table 7.53 Software Lock ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT EFh R/W Software Lock - - - - - - - LOCK 00h The Software Lock Register controls the software locking of critical registers. This register is software locked. Bit 0 - LOCK - this bit acts on all registers that are designated SWL. When this bit is set, the locked registers become read only and cannot be updated. 7.37 ‘0’ (default) - all SWL registers can be updated normally. ‘1’ - all SWL registers cannot be updated and a hard-reset is required to unlock them. Product Features Register Table 7.54 Product Features Register ADDR R/W REGISTER B7 B6 FCh R Product Features - - B5 B4 B3 ADDR_SEL[2:0] B2 B1 B0 DEFAULT SHDN_SEL[2:0] 00h The Product Features Register indicates which pin selected functionality is enabled. Bits 5-3 - ADDR_SEL[2:0] - Indicates the address that is decoded by the ADDR_SEL pin as shown in Table 7.55, "ADDR_SEL[2:0] Encoding". Table 7.55 ADDR_SEL[2:0] Encoding ADDR_SEL[2:0] 2 1 0 SMBUS ADDRESS 0 0 0 0101_100(r/w) 0 0 1 0101_101(r/w) 0 1 0 0101_110(r/w) Revision 1.2 (10-08-09) 70 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table 7.55 ADDR_SEL[2:0] Encoding (continued) ADDR_SEL[2:0] 2 1 0 SMBUS ADDRESS 0 1 1 1001_100(r/w) 1 0 0 1001_101(r/w) 1 0 1 1001_000(r/w) Bits 2-0 - SHDN_SEL[2:0] - Indicate the functionality enabled by the SHDN_SEL pin as shown in Table 7.56, "SHDN_SEL[2:0] Encoding". Table 7.56 SHDN_SEL[2:0] Encoding SHDN_SEL[2:0] 2 1 0 0 0 0 External Diode 1 Simple Mode - Beta compensation disabled, REC disabled recommended for AMD CPU diodes none 0 0 1 External Diode 1 Diode Mode - Beta compensation disabled, REC enabled none 0 1 0 External Diode 1 Transistor Mode - Beta compensation enabled, REC enabled - recommended for Intel 45nm and 65mn CPU diodes none 0 1 1 Internal Diode Transistor Mode - Beta compensation enabled, REC enabled none 1 0 0 External Diode 2 Transistor Mode - Beta compensation enabled, REC enabled none 1 0 1 External Diode 1 Transistor Mode - Beta compensation enabled, REC enabled none 7.38 DIODE MODE OTHER FEATURES Product ID Register Table 7.57 Product ID Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT FDh R Product ID Register 0 0 1 0 0 1 0 0 2Eh The Product ID Register contains a unique 8-bit word that identifies the product. SMSC EMC2113 71 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 7.39 Manufacturer ID Register Table 7.58 Manufacturer ID Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT FEh R Manufacturer ID 0 1 0 1 1 1 0 1 5Dh The Manufacturer ID Register contains an 8-bit word that identifies SMSC. 7.40 Revision Register Table 7.59 Revision Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT FFh R Revision 1 0 0 0 0 0 0 1 81h The Revision Register contains an 8-bit word that identifies the die revision. Revision 1.2 (10-08-09) 72 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Chapter 8 Typical Operating Curves The following Typical Operating Curves are included: Supply Current vs. Temperature Supply Current vs. Supply Voltage Temperature Error vs. Series Resistance Temperature Error vs. Ambient Temperature Temperature Error vs. Supply Voltage Fan TACH Accuracy vs. Temperature Fan TACH Accuracy vs. Supply Voltage PWM Output Frequency vs. Supply Voltage PWM Output Frequency vs. Temperature FSC Operation Look Up Table operation - PWM / Direct Drive Supply Current vs. Temperature VDD = 3.3V 1400 1400 1200 1200 4 / sec w/ Dynamic Averaging 4/ sec w/ dynamic averaging 1000 1000 Supply Current (uA) Supply Current (uA) Supply Current vs. Supply Voltage TA = 25°C 800 1/ sec w/o dynamic averaging 600 400 800 1 / sec w/o Dynamic Averaging 600 400 200 200 0 2.95 0 -50 0 50 Ambient Temperature (°C) 100 80 0.7 70 0.6 60 0.5 50 0.4 40 0.3 30 REC Enabled 0.2 20 0.1 10 0 0 40 80 120 0 160 3.55 3.65 0.3 0.2 0.1 0 -0.1 -0.2 -0.3 -0.4 -0.5 -50 Series Resistance (ohm) SMSC EMC2113 3.45 0.4 Temperature Error (°C) 0.8 3.35 0.5 Temperature Error (°C) – REC Disabled Temperature Error (°C) - REC Enabled 90 REC Disabled 3.25 Temperature Measurement Error vs. Ambient Temperature 100 0.9 3.15 Supply Voltage (V) Temperature Measurement Accuracy vs. Series Resistance 1 3.05 150 0 50 100 150 Ambient Temperature (°C) 73 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Tachometer Measurement Accuracy vs. Temperature Temperature Measurement Error vs. Supply Voltage 0.5 0.5 0.4 Tachometer Accuracy (%) 0.4 Temperature Error (°C) 0.3 0.2 0.1 0 -0.1 -0.2 -0.3 -0.4 -0.5 2.95 0.3 0.2 0.1 0 -0.1 -0.2 -0.3 -0.4 3.05 3.15 3.25 3.35 3.45 3.55 -0.5 -50 3.65 0 100 150 Tachometer Measurement Accuracy vs. Supply Voltage PWM Output Drive Frequency Variation vs. Ambient Temperature 1.4 0.5 Base = 26kHz, Divide = 0 0.4 1.2 Tachometer Accuracy (%) Normalized Drive Frequency 50 Ambient Temperature (°C) Supply voltage (V) 1 Base = 2441Hz, Divide = 128 = 19Hz 0.8 0.6 0.4 0.2 0.3 0.2 0.1 0 -0.1 -0.2 -0.3 -0.4 0 -50 0 50 100 -0.5 2.95 150 Ambient Temperature (°C) Revision 1.2 (10-08-09) 74 DATASHEET 3.05 3.15 3.25 3.35 Supply Voltage (V) 3.45 3.55 3.65 SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet PWM Output Drive Frequency Variation vs. Supply Voltage 1.4 Normalized Drive Frequency 1.2 FSC Algorithm PWM Ramping Update Time = 200ms; Max Step = 16 PWM counts RPM Target from 0 RPM -> 8000 RPM @ time t = 0 Base = 2441Hz, Divide = 128 = 19Hz 1 0.8 PWM Output Base = 26kHz, Divide = 0 0.6 0.4 10x Zoom on PWM Output 0.2 0 2.95 3.05 3.15 3.25 3.35 3.45 3.55 3.65 Spin Up Routine Ends – begins normal operation Update Time ends, PWM duty cycle changed Supply Voltage (V) Update Time ends, PWM duty cycle changed Duty Cycle Measured FSC Algorithm Spin Up Routine FSC Algorithm Spin Up Routine – NoKick Spin Time = 1.0s; Spin Level = 55%; Updated Time = 200ms; RPM Target from 0 RPM -> 8000 RPM @ time t = 0 Spin Time = 1.0s; Spin Level = 50%; UpdateTime = 200ms; RPM Target from 0 RPM -> 8000 RPM @ time t = 0 PWM Output PWM Output 10x Zoom on PWM Output 10x Zoom on PWM Output t=0 SMSC EMC2113 Duty Cycle Measured = 53.8% t=0 75 DATASHEET Duty Cycle Measured = 50% Revision 1.2 (10-08-09) Revision 1.2 (10-08-09) Datasheet PWM_IN LUT Programmed: PUSH_CFG = ‘1’, TEMP1_CFG = ‘1’; Temp 1 Threshold 1 = 50%; Temp 2 – 4 Threshold 1 = FFh; Setting 1 = 0% Temp 1 Threshold 2 = 55%; Temp 2 – 4 Threshold 2 = FFh; Setting 2 = 30% Temp 1 Threshold 3 = 65%; Temp 3 – 4 Threshold 3 = FFh; Setting 3 = 70% Temp 1 Threshold 4 = 75%; Temp 3 – 4 Threshold 4 = FFh; Setting 4 = 95% Hysteresis = 5 76 DATASHEET PWM Drive SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Look Up Table Operation RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Chapter 9 Package Drawing 9.1 EMC2113 Package Information Figure 9.1 16-Pin QFN 4mm x 4mm Package Dimensions Figure 9.2 16-Pin QFN 4mm x 4mm PCB Footprint SMSC EMC2113 77 DATASHEET Revision 1.2 (10-08-09) 78 DATASHEET RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Revision 1.2 (10-08-09) SMSC EMC2113 Figure 9.3 16-Pin QFN 4mm x 4mm Package Drawing RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 9.2 Package Markings TOP 0.41 LINE: 1 – SMSC Logo without circled (R) symbol LINE: 2 – Device Number LINE: 3 – Last 7 digits of Lot Number LINE: 4 – Revision and Country Code (RCC) 2 1 1 3 - 1 1 2 3 4 5 6 a RCC e3 3x 0.56 PB-FREE/GREEN SYMBOL (Matte Sn) PIN 1 LINES 1 to 3: CENTER HORIZONTAL ALIGNMENT LINE 4: LEFT HORIZONTAL ALIGNMENT BOTTOM BOTTOM MARKING NOT ALLOWED Figure 9.4 EMC2113 Package Markings SMSC EMC2113 79 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Appendix A Look Up Table Operation The EMC2113 uses a look-up table to apply a user-programmable fan control profile based on measured temperature to the fan driver. In this look-up table, each temperature channel is allowed to control the fan drive output independently (or jointly) by programming up to eight pairs of temperature and drive setting entries. The user programs the look-up table based on the desired operation. If the RPM-based Fan Speed Control Algorithm is to be used (see Section 6.6), then the user must program an RPM target for each temperature setting of interest. Alternately, if the RPM-based Fan Speed Control Algorithm is not to be used, then the user must program a drive setting for each temperature setting of interest. If the measured temperature on the External Diode channel meets or exceeds any of the temperature thresholds for any of the channels, the fan output will be automatically set to the desired setting corresponding to the exceeded temperature. In cases where multiple temperature channel thresholds are exceeded, the highest fan drive setting will take precedence. When the measured temperature drops to a point below a lower threshold minus the hysteresis value, the fan output will be set to the corresponding lower set point. The following sections show examples of how the Look Up Table is used and configured. Each Look Up Table Example uses the Fan 1 Look Up Table Registers configured as shown in Table A.1. Table A.1 Look Up Table Format STEP TEMP 1 TEMP 2 TEMP 3 TEMP 4 LUT DRIVE 1 LUT Temp 1 Setting 1 (52h) LUT Temp 2 Setting 1 (53h) LUT Temp 3 Setting 1 (54h) LUT Temp 4 Setting 1 (55h) LUT Drive Setting 1 (51h) 2 LUT Temp 1 Setting 2 (57h) LUT Temp 2 Setting 2 (58h) LUT Temp 3 Setting 2 (59h) LUT Temp 4 Setting 2 (5Ah) LUT Drive Setting 2 (56h) 3 LUT Temp 1 Setting 3 (5Ch) LUT Temp 2 Setting 3 (5Dh) LUT Temp 3 Setting 3 (5Eh) LUT Temp 4 Setting 3 (5Fh) LUT Drive Setting 3 (5Bh) 4 LUT Temp 1 Setting 4 (61h) LUT Temp 2 Setting 4 (62h) LUT Temp 3 Setting 4 (63h) LUT Temp 4 Setting 4 (64h) LUT Drive Setting 4 (60h) 5 LUT Temp 1 Setting 5 (66h) LUT Temp 2 Setting 5 (67h) LUT Temp 3 Setting 5 (68h) LUT Temp 4 Setting 5 (69h) LUT Drive Setting 5 (65h) 6 LUT Temp 1 Setting 6 (6Bh) LUT Temp 2 Setting 6 (6Ch) LUT Temp 3 Setting 6 (6Dh) LUT Temp 4 Setting 6 (6Eh) LUT Drive Setting 6 (6Ah) 7 LUT Temp 1 Setting 7 (70h) LUT Temp 2 Setting 7 (71h) LUT Temp 3 Setting 7 (72h) LUT Temp 4 Setting 7 (73h) LUT Drive Setting 7 (6Fh) 8 LUT Temp 1 Setting 8 (75h) LUT Temp 2 Setting 8 (76h) LUT Temp 3 Setting 8 (77h) LUT Temp 4 Setting 8 (78h) LUT Drive Setting 8 (74h) A.1 Example #1 This example does not use the RPM-based Fan Speed Control Algorithm. Instead, the Look Up Table is configured to directly set a PWM setting based on the temperature of four of its measured inputs. The configuration is set as shown in Table A.2, "Look Up Table Example #1 Configuration". Once configured, the Look Up Table is loaded as shown in Section Table A.3, "Fan Speed Control Table Example #1". Table A.4 shows three temperature configurations using the settings in Table A.3 and the final PWM output drive setting that the Look Up Table will select. Revision 1.2 (10-08-09) 80 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table A.2 Look Up Table Example #1 Configuration ADDR REGISTER 50h LUT Configuration A.1.1 B7 B6 B5 B4 B3 B2 B1 B0 SETTING USE_ DTS_F1 USE_ DTS_F2 LUT_ LOCK RPM / PWM PUSH1_ CFG TEMP1_ CFG TEMP3_ CFG TEMP4_ CFG C0h 0 0 1 1 0 0 0 0 LUT Configuration Bit Description Bit 7 - USE_DTS_F1 = ‘0b’ tells the circuitry that the Forced Temperature 1 register data is not in DTS format. Bit 6 - USE_DTS_F2 = ‘0b’ tells the circuitry that the Forced Temperature 2 register data is not in DTS format. Bit 5 - LUT_LOCK = ‘1b’ tells the circuitry that the LUT is programmed and is active. This bit must be set for the LUT to function. Bit 4 - RPM / PWM = ‘1b’ tells the Look Up Table that the FSC algorithm is not used and that the LUT target values will be PWM drive settings instead of TACH Target settings. Bit 3 - PUSH1_CFG = ‘0b’ tells the circuitry that the LUT should referenced the Forced Temperature data instead of the PWM Input Duty Cycle data. This is the default setting. Bit 2 - TEMP1_CFG = ‘0b’ tells the LUT to reference the External Diode 1 data instead of Forced Temperature 1 data. This is the default setting. Bit 1 - TEMP3_CFG = ‘0b’ tells the LUT to reference the External Diode 3 data instead of Forced Temperature 1 data. This is the default setting. Bit 0 - TEMP4_CFG = ‘0b’ tells the LUT to reference the Internal Diode data instead of Forced Temperature 2 data. This is the default setting. Table A.3 Fan Speed Control Table Example #1 FAN SPEED STEP # EXTERNAL DIODE 1 TEMPERATURE (CPU) EXTERNAL DIODE 2 TEMPERATURE (GPU) EXTERNAL DIODE 3 TEMPERATURE (SKIN) INTERNAL DIODE TEMPERATURE (AMBIENT) PWM SETTINGS 1 35oC 60oC 30oC 40oC 0% 2 40oC 70oC 35oC 45oC 30% 3 50oC 75oC 40oC 50oC 40% 4 60oC 80oC 45oC 55oC 50% 5 70oC 85oC 50oC 60oC 60% 6 80oC 90oC 55oC 65oC 70% 7 90oC 95oC 60oC 70oC 80% 8 100oC 100oC 65oC 75oC 100% Note: The values shown in Table A.3 are example settings. All the cells in the look-up table are programmable via SMBus. SMSC EMC2113 81 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table A.4 Fan Speed Determination for Example #1 (using settings in Table A.3) EXTERNAL DIODE 1 TEMPERATURE (CPU) EXTERNAL DIODE 2 TEMPERATURE (GPU) EXTERNAL DIODE 3 TEMPERATURE (SKIN) INTERNAL DIODE TEMPERATURE (AMBIENT) Example 1: 82°C 82°C 48°C 58°C 70% (CPU temp requires highest drive) Example 2: 82C° 97°C 62°C 58°C 80% (GPU and Skin require highest drive) Example 3: 82°C 97°C 62°C 75°C 100% (Internal temp requires highest drive) A.2 PWM RESULT Example #2 This example uses the RPM-based Fan Speed Control Algorithm. The Spin Level (used by the Spin Up Routine) should be changed to 40% drive for a total Spin Time of 1 second. For all other RPM configuration settings, the default conditions are used. For control inputs, it uses the External Diode 1 channel normally, the External Diode 2 channel normally, and both Pushed Temperature registers in DTS format. The configuration is set as shown in Table A.5, "Look Up Table Example #2 Configuration" while Table A.6, "Fan Speed Control Table Example #2" shows how the table is loaded. Note that when using DTS data, the USE_DTS_F1 and / or USE_DTS_F2 bits should be set. The Pushed Temperature Registers are loaded with the normal DTS values as received by the processor. When the DTS value is used by the Look Up Table, the value that is stored in the Pushed Temperature Register is subtracted from a fixed temperature of 100°C. This resultant value is then compared against the Look Up Table thresholds normally. When programming the Look Up Table, it is necessary to take this translation into account or else incorrect settings may be selected. Table A.5 Look Up Table Example #2 Configuration ADDR REGISTER 46h Fan Spin Up Configuration 50h LUT Configuration A.2.1 B7 B6 DRIVE_FAIL_CNT [1:0] B5 B4 NOKICK B3 B2 SPIN_LVL[2:0] B1 B0 SETTING SPINUP_TIME [1:0] 0Ah 0 0 0 0 1 0 1 0 USE_ DTS_F1 USE_ DTS_F2 LUT_ LOCK RPM / PWM PUSH1_ CFG TEMP1_ CFG TEMP3_ CFG TEMP4_ CFG 1 1 1 0 0 0 1 1 Fan Spin Up Configuration Bit Description Bits 7-6 - DRIVE_FAIL_CNT[1:0] = ‘00b’ tells the circuitry that the drive fail detection circuitry is not enabled. This is the default setting. Bit 5 - NOKICK = ‘0b’ tells the circuitry that if than Spin Up Routine is invoked, it will drive to 100% duty cycle for 25% of the spin up time. This is the default setting. Bits 4-2 - SPIN_LVL[2:0] = ‘010b’ tells the circuitry that if the Spin Up Routine is invoked, it should run at 40% drive. Revision 1.2 (10-08-09) 82 DATASHEET SMSC EMC2113 E5h RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Bits 1-0 - SPINUP_TIME[1:0] = ‘10b’ tells the circuitry that if the Spin Up Routine is invoked, it will run at 100% duty cycle for 250ms and at 40% duty cycle for 750ms for a total spin up time of 1s. A.2.2 LUT Configuration - Bit Description 7 - USE_DTS_F1 = ‘1b’ tells the circuitry that the data in the Pushed Temperature 1 register is in DTS format which means that the value in the register is equal to 100C - CPU Temp. Bit 6 - USE_DTS_F2 = ‘1b’ tells the circuitry that the data in the Pushed Temperature 1 register is in DTS format which means that the value in the register is equal to 100°C - CPU temp. Bit 5 - LUT_LOCK = ‘1b’ tells the circuitry that the LUT is programmed and is active. This bit must be set for the LUT to function. Bit 4 - RPM_PWM = ‘0b’ tells the LUT circuitry that the FSC algorithm is active and that the LUT values are TACH Target settings. This is the default setting. Bit 3 - PUSH1_CFG = ‘0b’ tells the circuitry that the LUT should referenced the Forced Temperature data instead of the PWM Input Duty Cycle data. This is the default setting. Bit 2 - TEMP1_CFG = ‘0b’ tells the LUT to reference the External Diode 1 data instead of Forced Temperature 1 data. Bit 1 - TEMP3_CFG = ‘1’b tells the Look Up Table to reference the Forced Temperature 1 data instead of the External Diode 3 data. Bit 0- TEMP4_CFG = ‘1b’ tells the Look Up Table to reference the Forced Temperature 2 data instead of the Internal Diode data. Table A.6 Fan Speed Control Table Example #2 FAN SPEED STEP # EXTERNAL DIODE 1 TEMPERATURE (CPU) EXTERNAL DIODE 2 TEMPERATURE (GPU) PUSHED TEMPERATURE SETTING (DTS1) PUSHED TEMPERATURE SETTING (DTS2) TACH TARGET HIGH BYTE 1 35oC 65oC 50oC 40oC EFh (1028 RPM) 2 40oC 75oC 55oC 45oC A3h (1508 RPM) 3 50oC 85oC 60oC 50oC 7Ah (2014 RPM) 4 60oC 90oC 65oC 55oC 62h (2508 RPM) 5 70oC 95oC 70oC 60oC 52h (2997 RPM) 6 80oC 100oC 75oC 65oC 3Dh (4029 RPM) 7 90oC 105oC 80oC 80oC 31h (5016 RPM) 8 100oC 110oC 85oC 100oC 29h (5994 RPM) Note: The values shown in Table A.6 are example settings. All the cells in the look-up table are programmable via SMBus. SMSC EMC2113 83 DATASHEET Revision 1.2 (10-08-09) RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Table A.7 Fan Speed Determination for Example #2 (using settings in Table A.6) EXTERNAL DIODE 1 TEMPERATURE (CPU) EXTERNAL DIODE 2 TEMPERATURE (GPU) Example 1: 75°C Example 2: Example 3: A.3 PUSHED TEMPERATURE (DTS1) PUSHED TEMPERATURE (DTS2) 75°C 35°C (translated as 65°C) 50°C (translated as 50°C) 52h (2997 RPM) CPU requires highest target 75°C 90°C 15°C (translated as 85°C) 20°C (translated as 80°C) 29h (5994 RPM) DTS1 requires highest target 75°C 97.25°C 30°C (translated as 70°C) 5°C (translated as 95°C) 31h (5016 RPM) DTS2 requires highest target PWM RESULT Example #3 This example uses the RPM-based Fan Speed Control Algorithm with default settings. For control inputs, it uses the External Diode 1 channel normally, the External Diode 2 channel normally, the PWM input instead of External Diode 3, and the Internal Diode. The configuration is set as shown in Table A.8 while Table A.9 shows how the table is loaded. Table A.8 Look Up Table Example #3 Configuration ADDR REGISTER 90h LUT Configuration A.3.1 B7 B6 B5 B4 B3 B2 B1 B0 SETTING USE_ DTS_F1 USE_ DTS_F2 LUT_ LOCK RPM / PWM PUSH1_ CFG TEMP1_ CFG TEMP3_ CFG TEMP4_ CFG 2Ah 0 0 1 0 1 0 1 0 LUT COnfiguration Bit Description Bit 7 - USE_DTS_F1 = ‘0b’ tells the circuitry that the Forced Temperature 1 register data is not in DTS format. Bit 6 - USE_DTS_F2 = ‘0b’ tells the circuitry that the Forced Temperature 2 register data is not in DTS format. Bit 5 - LUT_LOCK = ‘1b’ tells the circuitry that the LUT is programmed and is active. This bit must be set for the LUT to function. Bit 4 - RPM_PWM = ‘0b’ tells the LUT circuitry that the FSC algorithm is active and that the LUT values are TACH Target settings. This is the default setting. Bit 3 - PUSH1_CFG = ‘1b’ tells the Look Up Table to reference the PWM Input Duty Cycle instead of the Pushed Temperature 1 register. Bit 2 - TEMP1_CFG = ‘0b’ tells the LUT to reference the External Diode 1 data instead of Forced Temperature 1 data. This is the default setting. Revision 1.2 (10-08-09) 84 DATASHEET SMSC EMC2113 RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet Bit 1 - TEMP3_CFG = ‘1b’ tells the Look Up Table to reference Pushed Temperature 1 instead of External Diode 3, except that PUSH1_CFG re-directs the logic to reference the PWM Input Duty Cycle register instead. Bit 0 - TEMP4_CFG = ‘0b’ tells the LUT to reference the Internal Diode data instead of Forced Temperature 2 data. This is the default setting. Table A.9 Fan Speed Control Table Example #3 FAN SPEED STEP # EXTERNAL DIODE 1 TEMPERATURE (CPU) EXTERNAL DIODE 2 TEMPERATURE (GPU) 1 35oC 65oC 20% Duty Cycle (1Ah) 40oC EFh (1028 RPM) 2 40oC 75oC 30% Duty Cycle (26h) 45oC A3h (1508 RPM) 3 50oC 85oC 40% Duty Cycle (33h) 50oC 7Ah (2014 RPM) 4 60oC 90oC 50% Duty Cycle (40h) 55oC 62h (2508 RPM) 5 70oC 95oC 60% Duty Cycle (4Dh) 60oC 52h (2997 RPM) 6 80oC 100oC 70% Duty Cycle (5Ah) 65oC 3Dh (4029 RPM) 7 90oC 105oC 80% Duty Cycle (66h) 80oC 31h (5016 RPM) 8 100oC 110oC 90% Duty Cycle (73h) 100oC 29h (5994 RPM) PWM DUTY CYCLE TACH TARGET INTERNAL DIODE Note: The values shown in Table A.9 are example settings. All the cells in the look-up table are programmable via SMBus. Table A.10 Fan Speed Determination for Example #2 (using settings in Table A.9) EXTERNAL DIODE 1 TEMPERATURE (CPU) EXTERNAL DIODE 2 TEMPERATURE (GPU) PWM INPUT DUTY CYCLE INTERNAL DIODE PWM RESULT Example 1: 75°C 75°C 45% Duty Cycle 50°C 52h (2997 RPM) CPU requires highest target Example 2: 75°C 90°C 85% Duty Cycle 70°C 31h (5016 RPM) PWM requires highest target Example 3: 75°C 97.25°C 75% Duty Cycle 95°C 31h (5016 RPM) DTS2 requires highest target SMSC EMC2113 85 DATASHEET Revision 1.2 (10-08-09)