ETC ET2010/1

ET2010/-
Features
www.oxleygroup.com
Electronic Elapsed Time Indicator and Event Counter ET2010/This chapter contains product information for the Electronic Elapsed Time Indicator and Event Counter
ET2010/-.
Features
• Total electronic circuitry.
• Hours and/or events in a single package.
• EEPROM non-volatile memory.
• 10 years data retention.
• Printed circuit board mounting.
• Remote interrogation with hand-held reader.
• Nuclear survivability.
For ordering information see page 16.
Description
The Oxley Electronic Elapsed Time Indicator Type ET2010 is a PCB mounting device designed to record
both elapsed time and events. It is encapsulated in a low profile, board mounting package and ideal for
incorporation into equipment where individual Printed Circuit Board monitoring is required. The small
package size is highly suitable for systems where space is at a premium.
The ET2010 is available in 8 different versions, offering varying combinations of resolution and capacity. It
is equipped with a synchronous output data signal which may be simply interfaced to an LCD display;
alternatively the Oxley ET/HHR/3A hand-held reader may be used. For details of LCD driver circuitry,
please contact the Technical Sales Department.
4.57
1.5
7.62 mm
6 mm
Ø1
2.54
2.54
27.4 mm
Ø 0.7
13.4 mm
22.86 mm (0.9")
Pin 1
Oxley UK, Email [email protected]
Tel: +44 (0) 1229 582621
Fax: +44 (0) 1229 585090
13
Oxley Inc. USA, Email [email protected]
Tel: (203) 488 1033
Fax: (203) 481 6971
ET2010/-
Description
www.oxleygroup.com
Output Waveforms
LOAD
T CLK
= 0.9766 ms
CLK
DATA
LOAD
DATA
LOAD
CLK
DATA
Ratings
Supply voltage
18 V d.c. to 33 V d.c. (DEF STAN 61-5 Part 6 compatible)
Supply current
600 µA max at 5 V d.c., 15 mA at 30 V d.c.
Timing accuracy
± 0.1%
Event signal
TTL compatible
Event pulse width
0.1 µs to 8.0 ms
Event pulse frequency
50 Hz max
Data retention
10 year min at 25°C
Operating temperature
-55°C to +90°C
Storage temperature
-55°C to +100°C
Note: For 4.5 V d.c. to 10 V d.c. operation use the Vcc (+5 V) pin. For 18 V d.c. to 33 V d.c. operation use the
+28 V pin. Supply voltages between 10 V d.c. and 18 V d.c. may be used providing an external resistor
is also connected. For further information please contact the Technical Sales Department.
Oxley UK, Email [email protected]
Tel: +44 (0) 1229 582621
Fax: +44 (0) 1229 585090
14
Oxley Inc. USA, Email [email protected]
Tel: (203) 488 1033
Fax: (203) 481 6971
ET2010/-
www.oxleygroup.com
Environmental Standards
Pin Details
PIN
DETAILS
+28 V Positive supply (18 V d.c. to 33 V d.c.). This pin is compatible with supplies as defined by DEF STAN
61-5 Part 6 (Pin 1).
CLK
Asynchronous clock pin for use with LCD display driver or Oxley ET/HHR/3A hand-held reader
(Pin 2).
EVEN TTL compatible input for use when TTL event counting EETI’s are used. This pin is internally pulled
T
down to 0 V using a 100 KΩ resistor and may be left unconnected when not required (Pin 8).
LCD Asynchronous data pin for use with LCD display driver or Oxley ET/HHR/3A hand-held reader (Pin 9).
0V
Power supply common. Used in conjunction with either +28 V or Vcc (+5 V) (Pin 10).
Vcc
Positive supply (4.5 V d.c. to 10 V d.c.). Supplies exceeding this limit may be connected by inserting a
(+5 V) series resistor (Pin 11).
LOAD Asynchronous data load pin for connection to LCD display driver or Oxley ET/ HHR/3A (Pin 12).
N.C
No connection (Pin 19).
Vaux Positive supply connection for cold reads. Providing no supply is present at either +28 V or Vcc (+5 V)
powering the device by this pin will inhibit all counting or timing functions. The voltage at this pin must
be within the range 4.8 V d.c. to 6 V d.c. (Pin 20).
Environmental Standards
TEST
Bump
Shock
NEAREST EQUIVALENT MIL-STD-202
METHOD (except where stated)
SPECIFICATION
IEC 68-2-29, 4000 Bumps, 40 g
DEF STAN 07-55 200 g, 3 ms, 1/2 Sine Wave,
18 shocks total
IEC 68-2-6, 10-2000 Hz 20 g
IEC 68-2-3, -55/90/21
Vibration
Damp heat
(steady state)
Change of temp. IEC 68-2-14, Ta = 55°C, Tb = 90°C, TI = 30
mins
No equivalent
Method 213-2 Comp I, 00 g, 6 ms, sawtooth
Method 20K Cond D, 10-200 Hz 20 g
Method 103 Cond B, 96 hours
Method 107 Cond A
Nuclear Hardness
Maximum combined neutron & gamma ionising dose = 1550 cGy (Si)
Maximum neutron fluence 10 12 n/cm/cm
Hand-held Reader
A hand-held reader (ET/HHR/3A) to display the recorded data, is available to interface with the ET2000
series EETIs. The reader is battery powered, capable of interrogating the device without incrementing the
data stored within, and has no requirement for the host equipment to be energised. When active, the
reader automatically recognises the type of EETI connected and correctly formats the information.
Oxley UK, Email [email protected]
Tel: +44 (0) 1229 582621
Fax: +44 (0) 1229 585090
15
Oxley Inc. USA, Email [email protected]
Tel: (203) 488 1033
Fax: (203) 481 6971
ET2010/-
www.oxleygroup.com
Suggested Circuit Configura-
Suggested Circuit Configurations
ET 2010/ - 4.5 V to 10 V d.c. Operation
Positive
TTL
Common
1
2
2
1
8
9
1
1
1
+5 V
LOA
D
OXLEY
ET/HHR/3
DAT
ET 2010/ - 18 V to 33 V d.c. Operation
Positive
TTL
Common
1
2
2
1
8
9
1
1
1
+5 V
LOA
D
OXLEY
ET/HHR/3
DAT
Ordering Information
Type Number
Resolution (hours)
Capacity (hours)
Event Capacity
ET2010/1
1.0
999,999
-
ET2010/2
0.1
99,999.9
-
ET2010/5A
1.0
999,999
106 TTL
ET2010/5B
1.0
999,999
106 POWER UP
ET2010/6A
0.1
99,999.9
106 TTL
ET2010/6B
0.1
99,999.9
106 POWER UP
ET2010/7A
0.01
9,999.99
106 TTL
ET2010/7B
0.01
9,999.99
106 POWER UP
When ordering please specify type number and quantity.
Oxley UK, Email [email protected]
Tel: +44 (0) 1229 582621
Fax: +44 (0) 1229 585090
16
Oxley Inc. USA, Email [email protected]
Tel: (203) 488 1033
Fax: (203) 481 6971