VER:04 1 / 3 • OFFER SINGLE AND DUAL OUTPUT • 30 WATTS MAXIMUM OUTPUT POWER • 2:1 WIDE INPUT VOLTAGE RANGE • INTERNATIONAL SAFETY STANDARD APPROVAL • SIX-SIDED CONTINUOUS SHIELD • HIGH EFFICIENCY UP TO 90% • STANDARD 2” x 1.6” x 0.4” PACKAGE • FIXED SWITCHING FREQUENCY The FEC30 series offer 30 Watts of output power from a 2 x 1.6 x 0.4 inch package. The FEC30 series with 2:1 wide input voltage of 9-18VDC,18-36VDC and 36-75VDC and features 1600VDC of isolation, short-circuit and over-voltage protection,as well as six sided shielding. A safety approval to EN60950-1 and UL60950-1. All models are particularly suited to telecommunications, industrial, mobile telecom and test equipment applications. UL E193009 TUV CB CE MARK T E C H N I C A L S P E C I F I C AT I O N All specifications are typical at nominal input, full load and 25ºC otherwise noted GENERAL SPECIFICATIONS OUTPUT SPECIFICATIONS Output power Voltage accuracy 30 Watts max Efficiency Full load and nominal Vin Single/Dual Voltage adjustability Minimum load Single/Dual Line regulation LL to HL at Full Load Load regulation 10% to 100% FL Single Dual Single Dual Cross regulation (Dual) Asymmetrical load 25% / 100% FL 20MHz bandwidth Ripple and noise (Measured with a 104pF/50V MLCC) Transient response recovery time 25% load step change 1.5V output 1.8V output 2.5V output Over voltage protection 3.3V output Zener diode clamp 5V output 12V output 15V output 1000pF, max 300KHz, typ IEC60950-1, UL60950-1, EN60950-1 Nickel-coated copper Non-conductive black plastic Epoxy (UL94-V0) 2.00 X 1.60 X 0.40 Inch (50.8 X 40.6 X 10.2 mm) 300uS Dimensions 150%,max Maximum case temperature 100ºC Hiccup, automatics recovery Storage temperature range -55ºC ~ +105ºC Over temperature protection 12V nominal input 24V nominal input 48V nominal input 12V input DC-DC ON DC-DC OFF 24V input DC-DC ON DC-DC OFF 48V input DC-DC ON DC-DC OFF 9 – 18VDC 18 – 36VDC 36 – 75VDC 9VDC 8VDC 17.8VDC 16VDC 36VDC 33VDC 115ºC, typ Nature convection 10ºC/Watt Thermal impedance (Note 4) Nature convection with heat-sink 8.24ºC/Watt Thermal shock Vibration MIL-STD-810D 10~55Hz, 10G, 30minutes along X,Y and Z Relative humidity 5% to 95% RH EMC CHARACTERISTICS(Note 5) L-C type Conducted emissions 5V/ms,max Input voltage variation dv/dt (Complies with ETS300 132 part 4.4) Radiated emissions 12V input 36VDC ESD Input surge voltage 24V input 50VDC 100mS max 48V input 100VDC Radiated immunity Input reflected ripple (Note1) Nominal Vin and full load 30mAp-p Fast transient Nominal Vin and Power up 25mS typ Start up time constant resistive load Remote ON/OFF 25mS typ Surge Remote ON/OFF (Note 2) (Positive logic) DC-DC ON Open or 3.5V < Vr < 12V Conducted immunity DC-DC OFF Short or 0V < Vr < 1.2V Remote off input current Nominal Vin 2.5mA Input filter 9 10 ohms, min See table Base material INPUT SPECIFICATIONS Under voltage lockout 1600VDC, min 3.9V Weight 48g (1.69oz) 3.9V 6 3.9V MTBF (Note 3) 1.535 x 10 hrs 3.9V 6.2V ENVIRONMENTAL SPECIFICATIONS 15V -40ºC ~ +85ºC (with derating) 18V Operating temperature range % of FL at nominal input Short circuit protection Input voltage range See table Input to Output Input (Output) to Case ±0.02% / ºC, max Potting material Temperature coefficient Over load protection ± 1% Isolation voltage ± 10% Isolation resistance 0% Isolation capacitance ± 0.2% ± 0.5% Switching frequency ± 0.5% Approvals and standard ± 1% ± 5% Case material EN55022 Class A EN55022 Class A EN61000-4-2 Perf. Criteria B EN61000-4-3 Perf. Criteria A EN61000-4-4 Perf. Criteria B EN61000-4-5 Perf. Criteria B EN61000-4-6 Perf. Criteria A VER:04 Model Number Input Range Output Voltage Output Current FEC30-12S1P5 FEC30-12S1P8 FEC30-12S2P5 FEC30-12S3P3 FEC30-12S05 FEC30-12S12 FEC30-12S15 FEC30-12D12 FEC30-12D15 FEC30-24S1P5 FEC30-24S1P8 FEC30-24S2P5 FEC30-24S3P3 FEC30-24S05 FEC30-24S12 FEC30-24S15 FEC30-24D12 FEC30-24D15 FEC30-48S1P5 FEC30-48S1P8 FEC30-48S2P5 FEC30-48S3P3 FEC30-48S05 FEC30-48S12 FEC30-48S15 FEC30-48D12 FEC30-48D15 9-18 VDC 9-18 VDC 9-18 VDC 9-18 VDC 9-18 VDC 9-18 VDC 9-18 VDC 9-18 VDC 9-18 VDC 18 – 36 VDC 18 – 36 VDC 18 – 36 VDC 18 – 36 VDC 18 – 36 VDC 18 – 36 VDC 18 – 36 VDC 18 – 36 VDC 18 – 36 VDC 36 – 75 VDC 36 – 75 VDC 36 – 75 VDC 36 – 75 VDC 36 – 75 VDC 36 – 75 VDC 36 – 75 VDC 36 – 75 VDC 36 – 75 VDC 1.5 VDC 1.8VDC 2.5VDC 3.3 VDC 5 VDC 12 VDC 15VDC ±12 VDC ±15 VDC 1.5 VDC 1.8 VDC 2.5 VDC 3.3 VDC 5 VDC 12 VDC 15 VDC ±12 VDC ±15 VDC 1.5 VDC 1.8 VDC 2.5 VDC 3.3 VDC 5 VDC 12 VDC 15 VDC ±12 VDC ±15 VDC 6000mA 6000mA 6000mA 6000mA 6000mA 2500mA 2000mA ±1250mA ±1000mA 6000mA 6000mA 6000mA 6000mA 6000mA 2500mA 2000mA ±1250mA ±1000mA 6000mA 6000mA 6000mA 6000mA 6000mA 2500mA 2000mA ±1250mA ±1000mA Output Ripple&Noise Input Current (6) Eff (7) (%) Capacitor (8) Load max 50mVp-p 50mVp-p 50mVp-p 50mVp-p 50mVp-p 75 mVp-p 75 mVp-p 100 mVp-p 100 mVp-p 50mVp-p 50mVp-p 50mVp-p 50mVp-p 50mVp-p 75 mVp-p 75 mVp-p 100 mVp-p 100 mVp-p 50mVp-p 50mVp-p 50mVp-p 50mVp-p 50mVp-p 75 mVp-p 75 mVp-p 100 mVp-p 100 mVp-p 1014mA 1169mA 1582mA 2037mA 3012mA 2976mA 2976mA 3012mA 3012mA 493mA 580mA 780mA 1010mA 1490mA 1470mA 1470mA 1488mA 1488mA 244mA 290mA 390mA 500mA 740mA 730mA 730mA 744mA 744mA 78 81 83 85 87 88 88 87 87 80 82 84 86 88 89 89 88 88 81 83 85 87 89 90 90 88 88 85800uF 65000uF 33000uF 19500uF 10200uF 3240uF 1100uF ±1020uF ±675uF 85800uF 65000uF 33000uF 19500uF 10200uF 3300uF 1100uF ±1020uF ±675uF 85800uF 65000uF 33000uF 19500uF 10200uF 3300uF 1100uF ±1020uF ±675uF Note 2. 3. 4. 5. 6. 7. 8. Please add an external filter at converter input terminals when measuring input reflected ripple, as figure 1. L: Simulated source impedance of 12uH. C: Nippon chemi-con KMF series, 220μF/100V. The ON/OFF control pin voltage is referenced to negative input BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment) Heat sink is optional and P/N: 7G-0011A. An external filter capacitor is required for EMC testing. The capacitor should be capable of handing 1A ripple current for 12V/24V/48V models. Power mate suggest: C: Nippon chemi-con KMF series, 220μF/100V, ESR 90mΩ. Maximum value at nominal input voltage and full load. Typical value at nominal input voltage and full load. Test by minimum Vin and constant resistive load. FEC30-48S05 Derating Curve without Heat-Sink OUTPUT POWER (%) 1. 100 75 50 Nature convection 25 0 -40 -25 -10 0 50 60 70 80 90 100 AMBIENT TEMPERATURE (ºC) Figure 1 40 45 50 55 60 INPUT VOLTAGE (V) 65 70 75 90 89 88 87 86 85 84 80 78 76 74 OUTPUT POWER (%) 92 91 90 89 88 87 86 85 84 83 82 36 FEC30-48S05 (Note 5) Derating Curve with Heat-Sink FEC30-48S05 Efficiency VS Output load EFFICIENCY (%) EFFICIENCY (%) FEC30-48S05 Efficiency VS Input voltage 1 2 2 3 OUTPUT LOAD (A) 4 5 6 100 75 50 Nature convection 25 0 -40 -25 -10 0 50 60 70 80 90 100 AMBIENT TEMPERATURE (ºC) / 3 VER:04 DIA. 0.04(1.0) 1.60 (40.6) 0.60 (15.2) 0.70 (17.8) 0.40 (10.2) 0.20 (5.1) 2 1 1.80 (45.7) 2.00 (50.8) 4 Bottom View PIN CONNECTION PIN SINGLE DUAL 1 2 4 5 6 7 8 + INPUT - INPUT CTRL NO PIN + OUTPUT - OUTPUT TRIM + INPUT - INPUT CTRL + OUTPUT COMMON - OUTPUT TRIM EXTERNAL OUTPUT TRIMMING 8 7 6 5 0.40 (10.2) 0.40 (10.2) 0.70 (17.8) 0.50 (12.7) 1. All dimensions in Inches (mm) Tolerance x.xx±0.02(x.x±0.5) 2. Pin pitch tolerance ±0.014(±0.35) Output can be externally trimmed by using the method shown below. ( ) for dual output trim 0.22 (5.6) TRIM UP TRIM DOWN 7(7) 8(8) RU 8(8) RD 6(5) 3 / 3