P-DUKE FEC40

FEATURES
• 40 WATTS MAXIMUM OUTPUT POWER
• OUTPUT CURRENT UP TO 10A
• STANDARD 2” X 2” X 0.4” PACKAGE
• HIGH EFFICIENCY UP TO 88%
• 4:1 ULTRA WIDE INPUT VOLTAGE RANGE
• SIX-SIDED CONTINUOUS SHIELD
• FIXED SWITCHING FREQUENCY
• CE MARK MEETS 2006/95/EC, 93/68/EEC AND 2004/108/EC
• UL60950-1, EN60950-1 AND IEC60950-1 LICENSED
• ISO9001 CERTIFIED MANUFACTURING FACILITIES
• COMPLIANT TO RoHS EU DIRECTIVE 2002/95/EC
APPLICATIONS
Wireless Network
Telecom/Datacom
Industry Control System
Measurement Equipment
Semiconductor Equipment
OPTIONS
Negative logic Remove On/Off
DESCRIPTION
The FEC40W series offer 40 watts of output power from a 2.00 x 2.00 x 0.4
inch package. The FEC40W series with 4:1 ultra wide input voltage of
9-36VDC and 18-75VDC and features 1600VDC of isolation, short-circuit and
over-voltage protection.
T E C H N I C A L S P E C I F I C AT I O N
All specifications are typical at nominal input, full load and 25ºC otherwise noted
INPUT SPECIFICATIONS
OUTPUT SPECIFICATIONS
Output power
Voltage accuracy
40 Watts, max.
FL and nominal Vin
Single / Dual
± 1%
Minimum load (Note 6)
See Table
Voltage adjustability (Note 7) Single and Dual output
± 10%
Line regulation
LL to HL at Full Load
± 0.2%
Load regulation
(Note 8)
Single
Min. Load to Full Load
Dual
Single/Dual
Load cross regulation (Note 9)
± 0.5%
± 1%
Dual
± 5%
±0.02% / ºC, max.
Temperature coefficient
Transient response recovery time
25% load step change
250μS
3.3V output
5V output
Over voltage protection 12V output
Zener diode clamp
15V output
±12V output
±15V output
Over load protection
3.9VDC
6.2VDC
15VDC
18VDC
±15VDC
±18VDC
% of FL at nominal input
Short circuit protection
150%, max.
Hiccup, automatics recovery
GENERAL SPECIFICATIONS
Case grounding
See table
Input to Output
Input(Output) to Case
1600VDC, min.
1600VDC, min.
Connect case to –Vin
with decoupling Y Cap
9
Isolation resistance
Switching frequency
-40ºC ~ +50ºC (without derating)
+50ºC ~ +105ºC (with derating)
Operating ambient temperature
Thermal impedance
(Note 11)
110ºC, typ.
Without Heat-sink
With Heat-sink
9.2ºC/Watt
7.6ºC/Watt
300KHz, typ.
Relative humidity
FR4 PCB
Epoxy (UL94-V0)
2.00 X 2.00 X 0.40 Inch
(50.8 X 50.8 X 10.2 mm)
60g (2.11oz)
BELLCORE TR-NWT-000332
MIL-HDBK-217F
Over temperature protection
MIL-STD-810F
Base material
Weight
-55ºC ~ +125ºC
MIL-STD-810F
IEC60950-1, UL60950-1, EN60950-1
Potting material
+105ºC
Storage temperature range
Vibration
Nickel-coated copper
MTBF (Note 1)
ENVIRONMENTAL SPECIFICATIONS
Thermal shock
Case material
Dimensions
Input filter
Input surge voltage
24V input
100mS max
48V input
Input reflected ripple current Nominal Vin and full load
Nominal Vin and
Power up
Start up time
constant resistive load Remote ON/OFF
24V input
Start-up voltage
48V input
24V input
Shutdown voltage
48V input
Remote ON/OFF (Note 10)
Positive logic (standard)
DC-DC ON
Open or 3V < Vr < 12V
DC-DC OFF
Short or 0V < Vr < 1.2V
Negative logic (option)
DC-DC ON
Short or 0V < Vr < 1.2V
DC-DC OFF
Open or 3V < Vr < 12V
Input current of remote control pin Nominal Vin
-0.5mA ~ +0.5mA
24 Vin
10mA
Remote off state input current
48 Vin
5mA
2500pF, max.
10 ohms, min.
Isolation capacitance
Approvals and standard
9 – 36VDC
18 – 75VDC
Pi type
50VDC
100VDC
20mAp-p
20mS, max.
20mS, max.
9VDC
18VDC
8VDC
16VDC
Maximum case temperature
Efficiency
Isolation voltage
24V nominal input
48V nominal input
Input voltage range
6
1.105 x 10 hrs
5
1.511 x 10 hrs
5% to 95% RH
EMC CHARACTERISTICS
EMI (Note 12)
EN55022
Class A
ESD
EN61000-4-2
Air ± 8KV
Contact ± 6KV
Radiated immunity
EN61000-4-3
10 V/m
Perf. Criteria A
Fast transient (Note 13) EN61000-4-4
± 2KV
Perf. Criteria B
Surge (Note 13)
EN61000-4-5
± 1KV
Perf. Criteria A
Conducted immunity
EN61000-4-6
10 Vr.m.s
Perf. Criteria A
Page 1 of 3
Perf. Criteria A
Issued Date:2008/06/12
Model
Number
Input
Range
Output
Voltage
FEC40-24S3P3W
FEC40-24S05W
FEC40-24S12W
FEC40-24S15W
FEC40-24D12W
FEC40-24D15W
FEC40-48S3P3W
FEC40-48S05W
FEC40-48S12W
FEC40-48S15W
FEC40-48D12W
FEC40-48D15W
9 – 36 VDC
9 – 36 VDC
9 – 36 VDC
9 – 36 VDC
9 – 36 VDC
9 – 36 VDC
18 – 75 VDC
18 – 75 VDC
18 – 75 VDC
18 – 75 VDC
18 – 75 VDC
18 – 75 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
± 12 VDC
± 15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
± 12 VDC
± 15 VDC
Output Current
Input Current
Output(4)
Ripple
& Noise No load(3) Full load(2)
Min. load Full load
0mA
0mA
50mA
50mA
±65 mA
±50 mA
0mA
0mA
50mA
50mA
±65 mA
±60 mA
10000mA
8000mA
3333mA
2666mA
± 1667mA
± 1333mA
10000mA
8000mA
3333mA
2666mA
± 1667mA
± 1333mA
50mVp-p
50mVp-p
75mVp-p
75mVp-p
120mVp-p
150mVp-p
50mVp-p
50mVp-p
75mVp-p
75mVp-p
120mVp-p
150mVp-p
80mA
100mA
50mA
50mA
60mA
70mA
60mA
65mA
30mA
30mA
30mA
30mA
Eff (4)
(%)
Capacitor (5)
Load max
86
87
87
87
86
86
86
88
87
87
86
86
25750μF
13600μF
2360μF
1510μF
± 1200μF
± 750μF
25750μF
13600μF
2360μF
1510μF
± 1200μF
± 750μF
1677mA
2008mA
2008mA
2008mA
2032mA
2032mA
838mA
992mA
1004mA
1004mA
1016mA
1016mA
Note
11.
12.
13.
FEC40-48S05W Derating Curve
With Heatsink (Note
)
(Note611)
FEC40-48S05W Derating CurveWith
120
120
OUTPUT POWER(%)
8.
9.
10.
100
80
60
40
20
100
80
60
40
20
0
0
-40
-20
0
20
40
55 60
80
100
-40
120
-20
0
Ambient Temperature(℃)
FEC40-48S05W
Efficiency VS Input voltage
90
88
86
84
82
80
18
24
30
36
42
48
54
INPUT VOLTAGE(V)
20
40
55 60 64
80
100
120
Ambient Temperature(℃)
EFFICIENCY(%)
7.
OUTPUT POWER (%)
2.
3.
4.
5.
6.
BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40ºC.
MIL-HDBK-217F Notice2 @Ta=25 ºC, Full load(Ground, Benign, controlled environment).
Maximum value at nominal input voltage and full load.
Typical value at nominal input voltage and no load.
Typical value at nominal input voltage and full load.
Test by minimum Vin and constant resistive load.
The output requires minimum loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices,
however they may not meet all listed specification.
For the single output: Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +sense should be
connected to its corresponding +OUTPUT and likewise the -sense should be connected to its corresponding –OUTPUT.
Load regulation for dual output : Min load to 100% load balanced on all outputs.
Cross regulation for dual output : asymmetrical load 25% / 100% FL
The ON/OFF pin voltage is referenced to –Vin
To order negative logic ON/OFF control add the suffix-N (Ex: FEC40-24S05W-N).
Heat sink is optional and P/N:7G-0026C-F.
The FEC40W series can meet EN55022 Class A with parallel an external capacitor to the input pins.
Recommend : 24Vin : N/A
48Vin :2.2μF/100V*2 PCS 1812 MLCC.
An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220μF/100V, ESR 48mΩ.
EFFICIENCY(%)
1.
60
66
72
95
90
85
80
75
70
65
60
55
50
45
FEC40-48S05W
Efficiency VS Output Load
10
20
30
40
50
60
70
80
90
100
OUTPUT LOAD (% of Full Load)
Page 2 of 3
Issued Date:2008/06/12
Recommended Filter for EN55022 Class B Compliance
The components used in the above figure, together with the
manufacturers’ part numbers for these components, are as
1. All dimensions in Inches (mm)
Tolerance: X.XX±0.02 (X.X±0.5)
X.XXX±0.01 (X.XX±0.25)
2. Pin pitch tolerance ±0.01(0.25)
3. Pin dimension tolerance ±0.004 (0.1)
PIN CONNECTION
PIN
1
2
3
4
5
6
7
8
SINGLE
+INPUT
-INPUT
CTRL
-SENSE
+SENSE
+OUTPUT
-OUTPUT
TRIM
DUAL
+INPUT
-INPUT
CTRL
+OUTPUT
COM
COM
-OUTPUT
TRIM
follows:
C1
FEC4024xxxW
FEC4048xxxW
C2
C3
C4
C5 & C6
L1
450μH
1000pF/2KV Common
4.7μF/50V
4.7μF/50V
N/A
N/A
Choke
1812 MLCC
1812 MLCC
MLCC
PMT-048
830μH
2.2μF/100V 2.2μF/100V 2.2μF/100V 2.2μF/100V 1000pF/2KV Common
1812 MLCC 1812 MLCC 1812 MLCC 1812 MLCC
MLCC
Choke
PMT-053
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by
using the method shown below.
( ) for dual output trim
TRIM UP
TRIM DOWN
4(7)
8(8)
RU
8(8)
RD
5(4)
Recommended EN55022 Class B Filter Circuit Layout
Page 3 of 3
Issued Date:2008/06/12