LITTELFUSE 196

MINIA
TURE FUSES
INIATURE
5x20mm / No. 196
This product is not recommended
for new designs. Please refer to
Littelfuse No. 219XA.
IEC 60127-2/VI, 250V
250V,, T
Specifications
Time-Current Characteristic
Packaging
Time Lag (T)
000: Bulk (1000 pcs.)
002: Bulk (20x10 pcs.)
043: With mounted holder - Tape/Reel (1250 pcs.)
on request
Standard
IEC 60127-2/VI
Approvals
Materials
VDE
SEMKO
cULus Recognized
BSI License
CCC
Tube:
End Caps:
Optional Holders:
Operating TTemperature
emperature
Features
-25ºC to +70ºC (consider de-rating)
Enhanced breaking capacity
Visual fault indication
Direct solderable or plug-in versions
Internationally approved
Worldwide availability
Dimensions (mm)
Glass
Nickel-plated brass
Nickel-plated caps
Tin-plated copper wires
Climatic Category
-25ºC/+70ºC/21 days (EN 60068-1..3)
Stock Conditions
+10ºC to +60ºC
relative humidity ≤ 75% yearly average,
without dew, maximum value for 30 days-95%
W ebLinks
Vibration Resistance
Further info see:
www.wickmanngroup.com
Further application info see fuseology:
www.wickmanngroup.com/download/
24 cycles at 15 min. each (EN 60068-6)
10 - 60Hz at 0.75mm amplitude
60 - 2000Hz at 10g acceleration
Solderability
260ºC, ≤ 3 sec. (Wave)
350ºC, ≤ 1 sec. (Hand)
fuseology.pdf
Optional Holders
Soldering Heat Resistance
260ºC, 10 sec. (IEC 60068-2-20)
Marking
, T, Current Rating, E, 250V, Approvals
only 125 mA up to 8 A
Unit Weight
1.1g (approx.)
2.1g (with leads)
Limits for Pre-arcing Time
2.75 x IRated
200ms ...10s
600ms ...10s
4 x IRated
10 x IRated
40ms ... 3s 10ms ... 300ms
150ms ... 3s 20ms ... 300ms
Permissible continuous operating current is ≤ 100
% at ambient temperature of 23ºC (73.4ºF).
100%
Rated
Amp
Voltage
Breaking
Voltage Drop Power Dissipation Melting Integral
Current
Code
Rating
Capacity
1.0 x IRated
1.5 x IRated
10 x IRated
max. (mV)
max. (W)
min. (A2s)
32mA
40mA
50mA
63mA
80mA
100mA
125mA
160mA
200mA
250mA
315mA
400mA
500mA
630mA
800mA
1.00A
1.25A
1.60A
2.00A
2.50A
3.15A
4.00A
5.00A
6.30A
8.00 A
Order
Information
050912
0032
0040
0050
0063
0080
0100
0125
0160
0200
0250
0315
0400
0500
0630
0800
1100
1125
1160
1200
1250
1315
1400
1500
1630
1800
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
Qty.
150A / 250VAC
50-60Hz
cos ϕ = 1.0
OrderNumber
WebSite
Europe Tel: +49 2302 662-107
www.wickmanngroup.com E-mail: [email protected]
Series
196
2500
1600
1500
1300
1100
1000
900
800
600
550
350
300
250
200
180
150
135
125
110
100
100
90
100
70
70
Amp Code
Americas Tel: +1 404 699-7820
E-mail: [email protected]
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.5
0.5
0.6
0.6
0.7
0.7
0.8
0.9
0.6
1.0
1.1
1.0
1.3
1.5
2.0
0.010
0.011
0.019
0.035
0.055
0.075
0.13
0.24
0.30
0.90
1.2
2.4
4.4
7.5
11
15
22
36
12
17
30
50
70
136
149.5
Packaging
Asia Tel: +852 26 14-1108
E-mail: [email protected]
Approvals
CCC
< 2 min
< 2 min
BSI
2.1 x IRated
cURus
> 1h
> 1h
SEMKO
1.5 x IRated
32mA ... 100mA
125mA ... 6.30A
VDE
Rated Current
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Specifications are subject
to change without notice
China Tel: +86 21 6432 5146
E-mail: [email protected]
MINIA
TURE FUSES
INIATURE
00
0,0
10
5x20mm / No. 196
I-t Characteristics
,00
10
(Min-Max Limit)
IEC 60127-2/VI
(32 ... 100mA)
IEC 60127-2/VI
(125mA ... 6.30A)
0
0
1,0
0
10
10
Time (sec.)
0
1
0.1
1
0.0
01
0.0
1
1.5
2
3
4
5
6
7 8 9 10
15
I Fault / I Rated
Contact WICKMANN for individual I-t curves
050912
WebSite
www.wickmann.com
Europe Tel: +49 2302 662-107
E-mail: [email protected]
Americas Tel: +1 404 699-7820
E-mail: [email protected]
Asia Tel: +852 26 14-1108
E-mail: [email protected]
China Tel: +86 21 6432 5146
E-mail: [email protected]