HONEYWELL-ACC 19CPSIPG4K

19 mm Series
Low Cost, Stainless Steel,
Isolated Pressure Sensors
DESCRIPTION
They feature a variety of pressure connections to allow use in
Honeywell’s stainless steel 19C, 19U, and 19 Vacuum Gage
a wide range of OEM (Original Equipment Manufacturer)
Series sensors were developed for pressure applications that
equipment. The 19U Series is uncompensated for applications
involve measurement of hostile media in harsh environments
that use their own specialized circuit designs.
compatible with 316 stainless steel. The special Vacuum Gage
The 19C and 19U Series sensors are rugged and reliable
Series sensors are specifically designed for applications that
transducers for use in a wide variety of pressure sensing
can be exposed to vacuum.
applications where corrosive liquids or gases are monitored.
The 19C Series are calibrated and temperature compensated.
They are available for use with either a constant voltage or
current source.
FEATURES
POTENTIAL APPLICATIONS
•
Low cost
•
Industrial controls
•
Rugged, isolated stainless steel package
•
Process control systems
•
Small size
•
Industrial automation and flow control
•
Reliable semiconductor technology
•
Pressure calibrators
•
Calibrated and temperature compensated
•
Absolute and gage pressures
•
Vacuum compatible, isolated sensors
•
0 psi to 3 psi to, 0 psi to 500 psi
19 mm Series
PRESSURE SENSOR CHARACTERISTICS (All Devices)
Environmental Specifications
Compensated temperature range
Operating temperature range
Storage temperature range
Vibration
Shock
Life
Insulation resistance
0 °C to 82 °C [32 °F to 180 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
10 G at 20 Hz to 2000 Hz
100 G for 11 ms
1 million cycles min.
100 mΩ at 50 Vdc
Maximum Ratings
Voltage version “K”
Voltage version “L”
supply voltage VS = +15 Vdc
supply current IS = +2.0 mA
PRESSURE RANGE SPECIFICATIONS (19C, 19U)
Catalog Listing
19(C,U) 003P G (1…9) (K/L)
19(C,U) 005P G (1…9) (K/L)
19(C,U) 010P G (1…9) (K/L)
19(C,U) 015P (A,G,V) (1…9) (K/L)
19(C,U) 030P (A,G,V) (1…9) (K/L)
19(C,U) 050P (A,G,V) (1…9) (K/L)
19(C,U) 100P (A,G,V) (1…9) (K/L)
19(C,U) 200P (A,G,V) (1…9) (K/L)
19(C,U) 300P (A,G,V) (1…9) (K/L)
19(C,U) 500P (A,G,V) (1…9) (K/L)
Pressure Range
0 psig to 3 psig
0 psig to 5 psig
0 psig to 10 psig
0 psi to 15 psi
0 psi to 30 psi
0 psi to 50 psi
0 psi to 100 psi
0 psi to 200 psi
0 psi to 300 psi
0 psi to 500 psi
19C SERIES PERFORMANCE CHARACTERISTICS
www.honeywell.com/sensing
(7)
Burst Pressure
15 psig
25 psig
50 psig
75 psi
150 psi
250 psi
500 psi
1000 psi
1500 psi
2400 psi
(8)
(1)
Characteristic
Zero pressure offset
(2)
Full-scale span
(2)
Full-scale span (3 psi and 5 psi “K” units only)
(3)
Pressure non-linearity
(3)
Pressure hysteresis
Repeatability
(4)
Temp. effect on span
(4)
Temp. effect on offset
(4)
Temp. effect on span (0 psi to 3 psi and 0 psi to 5 psi only)
(4)
Temp. effect on offset (0 psi to 3 psi and 0 psi to 5 psi only)
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F])
(5)
Long-term stability of offset and span
(6)
Response time
(9)
Common mode voltage (voltage version “K”)
Input impedance (current version “L”)
Input impedance (voltage version “K”)
Output resistance
2
Proof Pressure
9 psig
15 psig
30 psig
45 psi
90 psi
150 psi
300 psi
600 psi
900 psi
1200 psi
Minimum
-2
98
48
–
–
–
–
–
–
–
–
–
–
0.5
2.0
8.0
3.0
Typical
0
100
50
±0.1
±0.015
±0.010
±0.5
±0.5
–
–
±0.1
±0.1
0.1
1.3
4.5
25
4.5
Maximum
2
102
52
±0.25
±0.030
±0.030
±1.0
±1.0
±2.0
±2.0
±0.3
±0.3
–
2.0
8.0
50
6.0
Unit
mV
mV
mV
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
ms
Vdc
kΩ
kΩ
kΩ
Low Cost, Stainless Steel, Pressure Sensors
19U SERIES PERFORMANCE CHARACTERISTICS
(1)
Characteristic
Zero pressure offset
(2)
Full-scale span
(2)
Full-scale span (3 psi and 5 psi only)
(3)
Pressure non-linearity
(3)
Pressure hysteresis
Repeatability
(10)
Temp. coefficient of resistance (0 °C to 82 °C [32 °F to 180 °F])
(10)
Temp. coefficient of offset (0 °C to 82 °C [32 °F to 180 °F])
(10)
Temp. coefficient of span (0 °C to 82 °C [32 °F to 180 °F])
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F])
(5)
Long-term stability of offset and span
(6)
Response time
Input resistance
Output resistance
Minimum
-7.5
30
20
–
–
–
2700
–
360
–
–
–
4.00
4.00
Typical
1.0
40
30
±0.1
±0.015
±0.010
3420
30
720
±0.1
±0.1
±0.1
4.75
4.75
19C VACUUM GAGE COMPENSATED SERIES PERFORMANCE CHARACTERISTICS
Characteristic
Zero pressure offset (at 0 psig)
(2)
Full-scale span (0 psig to positive full-scale)
(3)
Pressure non-linearity
(3)
Pressure hysteresis
Repeatability
(4)
Temp. effect on span
(4)
Temp. effect on offset
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F])
(5)
Long-term stability of offset and span
(6)
Response time
(9)
Common mode voltage (voltage version “K”)
Input impedance (current version “L”)
Input impedance (voltage version “K”)
Output resistance
Minimum
-2
98
–
–
–
–
–
–
–
–
0.5
1.5
8.0
3.0
Minimum
-7.5
30
–
–
–
2700
–
360
–
–
–
4.00
4.00
Unit
mV/V
mV/V
mV/V
%FSS
%FSS
%FSS
ppm/°C
μV/V/°C
ppm/°C
%FSS
%FSS
ms
kΩ
kΩ
Maximum
2
102
±0.25
±0.030
±0.030
±1.0
±1.0
±0.3
±0.3
–
2.0
8.0
50
6.0
Unit
mV
mV
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
ms
Vdc
kΩ
kΩ
kΩ
Maximum
7.5
60
±0.25
±0.030
±0.030
4500
–
1620
±0.3
±0.3
–
6.0
6.0
Unit
mV/V
mV/V
%FSS
%FSS
%FSS
ppm/°C
•V/V/°C
V/V/°C
ppm/°C
%FSS
%FSS
ms
kΩ
kΩ
(1)
Typical
0
100
±0.1
±0.015
±0.010
±0.5
±0.5
±0.1
±0.1
0.1
1.3
4.5
25
4.5
19U VACUUM GAGE UNCOMPENSATED SERIES PERFORMANCE CHARACTERISTICS
Characteristic
Zero pressure offset
(2)
Full-scale span (0 psig to positive full-scale)
(3)
Pressure non-linearity
(3)
Pressure hysteresis
Repeatability
(10)
Temp. coefficient of resistance (0 °C to 82 °C [32 °F to 180 °F])
(10)
Temp. coefficient of offset (0 °C to 82 °C [32 °F to 180 °F])
(10)
Temp. coefficient of span (0 °C to 82 °C [32 °F to 180 °F])
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F])
(5)
Long-term stability of offset and span
(6)
Response time
Input resistance
Output resistance
Maximum
7.5
60
40
±0.25
±0.030
±0.030
4500
–
1620
±0.3
±0.3
–
6.0
6.0
(1)
Typical
1.0
40
±0.1
±0.015
±0.010
3420
30
720
±0.1
±0.1
±0.1
4.75
4.75
Honeywell Sensing and Control
3
19 mm Series
Notes:
1. Reference conditions (unless otherwise noted): TA = 25 °C [77 °F]; 19C Supply VS = 10 Vdc ±0.01 Vdc or
IS = 1.5 mA ±0.0015 mA; 19U Supply VS = 5 Vdc ±0.01 Vdc or I = 1.0 mA ±0.0015 mA.
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operation pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F]
reading.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10% to 90% rise time.
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
9. Common mode voltage as measured from output to ground. For higher levels of common mode voltage, contact factory.
10. The error band resulting from a maximum deviation of a transducer’s output parameter (offset, span, or resistance) as
temperature is varied 25 °C [77 °F] to any other temperature within the specified range (0 °C to 82 °C [32 °F to 180 °F]). This
parameter is not 100% tested and is guaranteed by process design and tested on a sample basis only. Temperature
coefficient of span is evaluated using a 1 mA constant current excitation source.
PHYSICAL DIMENSIONS (For reference only: mm [in].)
Package 1 (see note): Cell Package
Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to ±0.006 in between the upper and lower portions of the
sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-concentricity).
Package 2: Flush Mount Package
Package 3: Flush Mount with Flange
4 Honeywell • Sensing and Control
Low Cost, Stainless Steel, Pressure Sensors
Package 4: Male 1/8-27 NPT
Package 5: Male 1/4-18 NPT
Honeywell Sensing and Control
5
19 mm Series
Package 6: Male 7/16 UNF
Package 7: Male 1/4 BSPP
Package 8: Euro Ring (See note)
Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to ±0.006 in between the upper and lower
portions of the sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-concentricity).
6 Honeywell • Sensing and Control
Low Cost, Stainless Steel, Pressure Sensors
Package 9: VCR Gland (Female nut)
ORDERING INFORMATION
Honeywell Sensing and Control
7
WARNING
WARNING
PERSONAL INJURY
MISUSE OF DOCUMENTATION
DO NOT USE these products as safety or emergency stop
•
devices or in any other application where failure of the
The information presented in this product sheet is for
reference only. Do not use this document as a product
product could result in personal injury.
installation guide.
Failure to comply with these instructions could result in
death or serious injury.
•
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
death or serious injury.
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
SALES AND SERVICE
by Honeywell in writing; please refer to your order
Honeywell serves its customers through a worldwide network
acknowledgement or consult your local sales office for specific
of sales offices, representatives and distributors. For
warranty details. If warranted goods are returned to Honeywell
application assistance, current specifications, pricing or name
during the period of coverage, Honeywell will repair or replace,
of the nearest Authorized Distributor, contact your local sales
at its option, without charge those items it finds defective. The
office or:
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
E-mail: [email protected]
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
Internet: www.honeywell.com/sensing
Phone and Fax:
While we provide application assistance personally, through
Asia Pacific
+65 6445-3033 Fax
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
+65 6355-2828
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
application.
Latin America +1-305-805-8188
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 55422
www.honeywell.com/sensing
009132-3-EN IL50 GLO Printed in USA