SENSORTECHNICS RXUM050D

RXU Series
Basic pressure sensors
FEATURES
· 0...25 mbar to 0...10 bar,
0...10 inch H2O to 0...150 psi,
differential, gage or absolute pressure
· High impedance bridge
· Low power consumption for battery
operation
· Sensortechnics PRO services
MEDIA COMPATIBILITY
To be used with non-corrosive, non-ionic working
fluids such as clean dry air, dry gases and the like.
EQUIVALENT CIRCUIT
SPECIFICATIONS
Maximum ratings
Supply voltage, VS
Button or
"N" package
+Vs
12 VDC
Temperature ranges
Operating
Storage
-40 to +85°C
-55 to +125°C
Output
Humidity limits (non-condensing)
0 to 100 %RH
-
Lead temperature (soldering 4 sec.)
Common-mode pressure
RXUM025D4/RXUH010D4
all others
+
250°C
50 psi
150 psi
DIP Package
+Vs
Output
+
E / 11707 / A
1/7
www.sensortechnics.com
RXU Series
Basic pressure sensors
PRESSURE SENSOR CHARACTERISTICS
(Vs = 5.0 ± 0.01 V, TA = 25 °C, common-mode pressure = 0 psig, pressure applied to P1 for Button, N and A2
housings, pressure applied to P2 for G2 and D4 housings)
Part number
Operating pressure
Proof pressure8
RXUM025...
RXUM050...
RXUM100...
RXUM250...
RXUB001...
RXUB002...
RXUB005...
RXUB010...
RXUH010...
RXUP001...
RXUP005...
RXUP015...
RXUP030...
RXUP100...
RXUP150...
0...25 mbar
0...50 mbar
0...100 mbar
0...250 mbar
0...1 bar
0...2 bar
0...5 bar
0...10 bar
0..10 inch H2O
0...1 psi
0...5 psi
0...15 psi
0...30 psi
0...100 psi
0...150 psi
500 mbar
1.4 bar
1.4 bar
1.4 bar
2 bar
4 bar
10 bar
14 bar
7 p si
2 0 p si
2 0 p si
3 0 p si
6 0 p si
1 5 0 p si
2 0 0 p si
Full-scale span1
Min.
Typ.
Max.
20 mV
10.9 mV
21.8 mV
36.3 mV
72.5 mV
72.5 mV
72.5 mV
72.5 mV
20 mV
15 mV
50 mV
75 mV
75 mV
100 mV
75 mV
45 mV
14.5 mV
29 mV
54.0 mV
105 mV
105 mV
105 mV
105 mV
45 mV
20 mV
75 mV
110 mV
110 mV
150 mV
110 mV
80 mV
18.1 mV
36.2 mV
72.5 mV
145 mV
145 mV
145 mV
145 mV
80 mV
25 mV
100 mV
150 mV
150 mV
200 mV
150 mV
Specification notes:
1. Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
2. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing
pressure. Linearity is the maximum deviation of measure output at constant temperature (25°C) from "Best Straight Line"
determined by three points, offset, full scale pressure and half full scale pressure.
3. Maximum difference in output at any pressure with the operating pressure range and temperature within 0°C to +70°C after:
a) 100 temperature cycles, 0°C to +70°C
b) 1.0 million pressure cycles, 0 psi to full scale span
4. Slope of the best straight line from 0°C and 70°C. For operation outside this temperature, contact Sensortechnics for more
specific applications information.
5. Response time for a 0 to full-scale span pressure step change.
6. Long term stability over a one year period .
7. This parameter is not 100 % tested. It is guaranteed by process design and tested on a sample basis only.
8. If the proof pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture.
Note: The proof pressure for the forward gage of all devices in the D4-package is the specified value or 100 psi, whatever is less.
9. The zero pressure offset is 0 mV Min, 20 mV Typ and 35 mV Max for part nos. RXU...G2 and RXU...D4.
E / 11707 / A
2/7
www.sensortechnics.com
RXU Series
Basic pressure sensors
PERFORMANCE CHARACTERISTICS
(Vs = 5.0 ± 0.01 V, TA = 25 °C, common-mode pressure = 0 psig, pressure applied to P1 for Button, N and A2
housings, pressure applied to P2 for G2 and D4 housings)
25 mbar/10 inch H2O devices
Characteristics
Zero pressure offset
Temperature effects
(0 to 70 °C)4,7
Min.
Typ.
Max.
Unit
-35
-20
±4
-2300
+750
±0.2
±0.5
±0.1
4.0
4.0
0.1
2
0
mV
µV/V/°C
Offset
Span
Bridge impedance
Combined linearity and hysteresis2
Repeatability3
Long term stability of offset and span6
Input impedance
Output impedance
Response time5
Position sensitivity
ppm/°C
±1.0
%FSS
mV
kΩ
ms
µV/V/g
All other devices
Characteristics
Zero pressure offset9
Temperature effects
(0 to 70 °C)4,7
Offset
Span
Bridge impedance
Combined linearity and hysteresis2
Repeatability3
Long term stability of offset and span6
Input impedance
Output impedance
Response time5
E / 11707 / A
Min.
Typ.
Max.
Unit
-35
-20
±4
-2150
+750
±0.2
±0.5
±0.1
4.1
4.1
0.1
0
mV
µV/V/°C
-2550
+690
-1900
+810
±0.5
ppm/°C
%FSS
mV
kΩ
ms
3/7
www.sensortechnics.com
RXU Series
Basic pressure sensors
PHYSICAL DIMENSIONS
Button package
third angle projection
mass: 1 g
dimensions in mm (inches)
Colour codes for Button housing
Colour dot 1
Yellow
Green
Light blue
Purple
Orange
Dark brown
Red
E / 11707 / A
Pressure range
25 mbar, 10 "H2O
50 mbar, 100 mbar, 1 psi
250 mbar, 5 psi
1 bar, 15 psi
2 bar, 30 psi
5 bar, 100 psi
10 bar, 150 psi
Colour dot 2
Gold
Series
RXU
4/7
www.sensortechnics.com
RXU Series
Basic pressure sensors
PHYSICAL DIMENSIONS (cont.)
N package
third angle projection
mass: 5 g
dimensions in mm (inches)
DIP package, single port
Ø 2.67
(0.105) TYP
2 ° draft
13.97
(0.550)
11.94
(0.470)
8.00
(0.315)
13.84
(0.545)
Ø 0.64 (0.025)
vent hole
(gage devices only)
1.91
(0.075)
15.2
(0.60) NOM
0.25
(0.010)
TYP
2.79
(0.110) TYP
6.00
(0.24) NOM
0.51
(0.020) TYP
2.54
(0.100) TYP
third angle projection
mass: 1 g
E / 11707 / A
dimensions in mm (inches)
5/7
www.sensortechnics.com
RXU Series
Basic pressure sensors
PHYSICAL DIMENSIONS (cont.)
DIP package, dual port
3.6
(0.14)
Ø 2.29
(0.090) TYP
2 ° draft
3.43
(0.135)
13.97
(0.550)
7.62
(0.300) TYP
9.65
7.24
(0.380)
(0.285)
6.4
(0.25)
11.94
(0.470)
4.3
(0.17) TYP
15.2
(0.60) NOM
0.25
(0.010)
TYP
0.51
(0.020) TYP
2.79
(0.110) TYP
2.54
(0.100) TYP
third angle projection
mass: 1 g
dimensions in mm (inches)
ELECTRICAL CONNECTION
RXU...(Button) and
RXU...N
RXU...A2
out P1
1
+Vs
P1
+Vs
P2
GND
out +
4
RXU...D4
Pin 1 identified by
chamfered corner
Pin 1 identified by
chamfered corner
Pin 1 identification tab
GND 1
out + 2
+VS 3
out - 4
RXU...G2
+Vs
+Vs
4
1 out +
out +
GND
GND
out -
out -
+Vs
1
P1
P2
4
+Vs
Vent hole
The polarity indicated is for pressure applied to
E / 11707 / A
RXU...(Button), ...N, ...A2 :
RXU...G2, ...D4
:
P1 (forward gage)
P2 (backward gage)
6/7
www.sensortechnics.com
RXU Series
Basic pressure sensors
ORDERING INFORMATION - AVAILABLE LISTINGS
Note:
Preferred listings are highlighted in grey
Pressure range
Absolute pressure
Button package
N p ackag e
DIP single port
0...1 bar
RXUB001A
-
-
0...2 bar
-
RXUB002AN
-
0...5 bar
RXUB005A
-
-
0...10 bar
RXUB010A
-
-
0...15 psi
RXUP015A
-
-
0...30 psi
-
RXUP030AN
-
0...100 psi
RXUP100A
-
-
0...150 psi
RXUP150A
-
-
Pressure range
Gage and differential/gage pressure
Button package
N p ackag e
DIP single port
DIP dual port
0...50 mbar
RXUM050D
RXUM050DN
RXUM050G2
RXUM050D4
0...100 mbar
RXUM100D
RXUM100DN
RXUM100G2
RXUM100D4
0...250 mbar
-
-
RXUM250G2
-
RXUB001D
-
-
-
0...25 mbar
0...1 bar
-
0...2 bar
-
-
-
RXUB002D4
0...5 bar
RXUB005D
RXUB005DN
RXUB005G2
RXUB005D4
0...10 bar
RXUB010D
0...10 inch H20
RXUH010D4
0...1 psi
RXUP001D
RXUP001DN
RXUP001G2
0...5 psi
-
-
RXUP005G2
RXUP001D4
-
0...15 psi
RXUP015D
-
-
-
0...30 psi
-
-
-
RXUP030D4
0...100 psi
RXUP100D
RXUP100DN
RXUP100G2
RXUP100D4
0...150 psi
RXUP150D
-
-
-
Sensortechnics PRO services:
· Extended guarantee period of 2 years
· Improved performance characteristics
· Custom product modifications and adaptations even for small quantities
· Advanced logistics models for supply inventory and short delivery times
· Technical support through application engineers on the phone or at your site
· Fastest possible technical response for design and QA engineers
... plus other services on request
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11707 / A
7/7
www.sensortechnics.com