GPSEMI GC140R

Green Power Solutions srl
Via Greto di Cornigliano 6R - 16152 Genova , Italy
Phone: +39-010-659 1869
Fax: +39-010-659 1870
Web: www.gpsemi.it
E-mail: [email protected]
GC140…R
BAR CLAMP FOR HOCKEY PUK DEVICES
Clamping total thikness of assembly from
15mm to 105mm
Pre-loaded to the specific clamping
force (35 ÷ 45 kN)
Maximum device diameter: 124mm
Surface passivation to provide extra protection
Hexagon head bolt partially
threaded M10x1.5, UNI5931, 8.8 steel
Various lengths of bolts and insulators
Round shaped clamping head for optimal clamping
force application
Four styles available
User friendly clamping force indicator
UL94 certified insulation material
Parameter
Weight
Clamping Force*
Unit
g
kN
Types
Testing
conditions
Values
Notes
Min
GC140S…R
GC140B…R
35
GC140…40R
GC140…45R
40
45
± 10%
VRMS
Insulating Material
*
3000
E121562
Max. working temperature
°C
Creepage distance:
mm
Clearance distance:
mm
Storage temperature
°C
110
-30
49.4
40.0
110
-40
mm
UL94 V-1 Flame class rating
1.5
mm
UL94 V-0 Flame class rating
8.00
mm
CSA Flammability
1.00
Other clamping forces available: contact factory

** Noryl is a registered trade mark of General Electric
Document GC140…R
1 min
Noryl  ∗∗
UL File
Flammability
Max
2050
2450
GC140…35R
Clamping Force tolerance
Insulation Voltage
Typ
1980
2380
GC140…R
BAR CLAMP FOR HOCKEY PUK DEVICES
ORDERING INFORMATION TABLE
GC140
Clamps can be ordered using the following part numbering system
(1) Construction type:
B
N
A
B
40
(1)
(2)
(3)
(4)
(5)
R
B = with double bar
S = with single bar
(2) Insulator position:
N = upper side
R = lower side
(3) Insulator code:
(4) Bolt code:
(5) Clamping force (in kN):
see table below
K
35
K
A (100mm long)
40
45
Type GC140BN…R: suggested insulator/bolt types
Allowed clearance S
S' Min[mm]**
K: Total thickness of the assembly to be clamped
Insulator choice
Bolt choice
(3)
(4)
Bolt Length [mm]
T [mm]
A
100
A
180
195
66
A
100
B
190
205
61
76
A
100
C
200
215
71
86
A
100
D
210
225
81
96
A
100
E
220
235
91
106
A
100
F
230
245
SMax [mm]
41
56
51
Type GC140BR…R: suggested insulator/bolt types
Allowed clearance S
Insulator choice
S' Min[mm]**
S Min [mm]
Bolt choice
(3)
Ins. Lenght [mm]
(4)
Bolt Length [mm]
T [mm]
41
56
A
100
A
180
195
51
66
A
100
B
190
205
61
76
A
100
C
200
215
71
86
A
100
D
210
225
81
96
A
100
E
220
235
91
106
A
100
F
230
245
Bolt choice
Max height
S Min [mm]
SMax [mm]
(3)
Ins. Lenght [mm]
(4)
Bolt Length [mm]
T [mm]
66
81
A
100
A
180
195
76
91
A
100
B
190
205
86
101
A
100
C
200
215
96
111
A
100
D
210
225
106
121
A
100
E
220
235
116
131
A
100
F
230
245
Type GC140SR…R: suggested insulator/bolt types
Allowed clearance S
Insulator choice
S' Min[mm]**
Max height
SMax [mm]
Type GC140SN…R: suggested insulator/bolt types
Allowed clearance S
Insulator choice
S' Min[mm]**
Max height
Ins. Length [mm]
S Min [mm]
Bolt choice
Max height
S Min [mm]
SMax [mm]
(3)
Ins. Lenght [mm]
(4)
Bolt Length [mm]
T [mm]
66
81
A
100
A
180
195
76
91
A
100
B
190
205
86
101
A
100
C
200
215
96
111
A
100
D
210
225
106
121
A
100
E
220
235
116
131
A
100
F
230
245
Document GC140…R
BAR CLAMP FOR HOCKEY PUK DEVICES
GC140…R
100
84.5
BAR CLAMP OUTLINES
S
125
30
25
125
140
GC140BN...R
25
25
170
GC140BR...R
15
4
84.5
98
170
125
125
S
S
Ø15
30
15,3
Ø25
25
140
GC140SN...R
GC140SR...R
Dimensions in mm - Tolerances according to ISO 2768 MK
Document GC140…R