Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: [email protected] GC140…R BAR CLAMP FOR HOCKEY PUK DEVICES Clamping total thikness of assembly from 15mm to 105mm Pre-loaded to the specific clamping force (35 ÷ 45 kN) Maximum device diameter: 124mm Surface passivation to provide extra protection Hexagon head bolt partially threaded M10x1.5, UNI5931, 8.8 steel Various lengths of bolts and insulators Round shaped clamping head for optimal clamping force application Four styles available User friendly clamping force indicator UL94 certified insulation material Parameter Weight Clamping Force* Unit g kN Types Testing conditions Values Notes Min GC140S…R GC140B…R 35 GC140…40R GC140…45R 40 45 ± 10% VRMS Insulating Material * 3000 E121562 Max. working temperature °C Creepage distance: mm Clearance distance: mm Storage temperature °C 110 -30 49.4 40.0 110 -40 mm UL94 V-1 Flame class rating 1.5 mm UL94 V-0 Flame class rating 8.00 mm CSA Flammability 1.00 Other clamping forces available: contact factory ** Noryl is a registered trade mark of General Electric Document GC140…R 1 min Noryl ∗∗ UL File Flammability Max 2050 2450 GC140…35R Clamping Force tolerance Insulation Voltage Typ 1980 2380 GC140…R BAR CLAMP FOR HOCKEY PUK DEVICES ORDERING INFORMATION TABLE GC140 Clamps can be ordered using the following part numbering system (1) Construction type: B N A B 40 (1) (2) (3) (4) (5) R B = with double bar S = with single bar (2) Insulator position: N = upper side R = lower side (3) Insulator code: (4) Bolt code: (5) Clamping force (in kN): see table below K 35 K A (100mm long) 40 45 Type GC140BN…R: suggested insulator/bolt types Allowed clearance S S' Min[mm]** K: Total thickness of the assembly to be clamped Insulator choice Bolt choice (3) (4) Bolt Length [mm] T [mm] A 100 A 180 195 66 A 100 B 190 205 61 76 A 100 C 200 215 71 86 A 100 D 210 225 81 96 A 100 E 220 235 91 106 A 100 F 230 245 SMax [mm] 41 56 51 Type GC140BR…R: suggested insulator/bolt types Allowed clearance S Insulator choice S' Min[mm]** S Min [mm] Bolt choice (3) Ins. Lenght [mm] (4) Bolt Length [mm] T [mm] 41 56 A 100 A 180 195 51 66 A 100 B 190 205 61 76 A 100 C 200 215 71 86 A 100 D 210 225 81 96 A 100 E 220 235 91 106 A 100 F 230 245 Bolt choice Max height S Min [mm] SMax [mm] (3) Ins. Lenght [mm] (4) Bolt Length [mm] T [mm] 66 81 A 100 A 180 195 76 91 A 100 B 190 205 86 101 A 100 C 200 215 96 111 A 100 D 210 225 106 121 A 100 E 220 235 116 131 A 100 F 230 245 Type GC140SR…R: suggested insulator/bolt types Allowed clearance S Insulator choice S' Min[mm]** Max height SMax [mm] Type GC140SN…R: suggested insulator/bolt types Allowed clearance S Insulator choice S' Min[mm]** Max height Ins. Length [mm] S Min [mm] Bolt choice Max height S Min [mm] SMax [mm] (3) Ins. Lenght [mm] (4) Bolt Length [mm] T [mm] 66 81 A 100 A 180 195 76 91 A 100 B 190 205 86 101 A 100 C 200 215 96 111 A 100 D 210 225 106 121 A 100 E 220 235 116 131 A 100 F 230 245 Document GC140…R BAR CLAMP FOR HOCKEY PUK DEVICES GC140…R 100 84.5 BAR CLAMP OUTLINES S 125 30 25 125 140 GC140BN...R 25 25 170 GC140BR...R 15 4 84.5 98 170 125 125 S S Ø15 30 15,3 Ø25 25 140 GC140SN...R GC140SR...R Dimensions in mm - Tolerances according to ISO 2768 MK Document GC140…R