MA-COM HC-1

3.5 kV Kilovac HC-1
Kilovac HC-3
No Load Switching
Features:
Make & Break Load Switching
HC-1
• Widely used for RF applications
• Vacuum dielectric for low leakage current
applications
• Copper contacts for high current capability
• Not designed for power switching
• Meets requirements of MIL-R-83725
• QPL version available, M83725/5-001
HC-3
• Tungsten contacts for long life when power
switching
• Vacuum dielectric for power switching low
current loads
Kilovac HC-5
Features:
Make Only Load Switching
• Gas-filled for “make only” power switching
• SF-6 gas filled for capacitive discharge
applications
PRODUCT SPECIFICATIONS
HC-1
Unit
HC-3
HC-5
Nominal, Volts dc
12
26.5
115
Contact Arrangement ..........................................................
SPDT
SPDT
SPDT
Pickup, Volts dc, Maximum
8
16
80
Contact Form ........................................................................
C
C
C
Drop-Out, Volts dc
5
5
5
Coil Resistance (Ohms ±10%)
Part Number
Test Voltage (dc or 60Hz) ...................................................
kV Peak
Rated Operating Voltage .....................................................
kV Peak
COIL DATA
3.5
3.5
3.5
2.5 MHz ...........................................................................
2.5
-
-
16 MHz ............................................................................
2
-
-
32 MHz ............................................................................
1.5
-
-
dc or 60 Hz .....................................................................
25
18
8
2.5 MHz ...........................................................................
14
-
-
16 MHz ............................................................................
9
-
-
32 MHz ............................................................................
7
-
-
Coil Hi-Pot (V RMS, 60 Hz) ...........................................
500
500
500
Between Open Contacts .................................................
2
-
-
Open Contacts to Ground ..............................................
2.5
-
-
Contact Capacitance ............................................................
80
1 - 10 5 - 50
335
6000
Ratings listed are for 25°C, sea level conditions
dc or 60 Hz .....................................................................
Continuous Carry Current , Maximum ...............................
.5 - 5
Amps
PART NUMBER SELECTION
Sample Part No.
HC Model
1
3
5
Coil Voltage
Blank = 26.5Vdc
/12Vdc = 12Vdc
/115Vdc = 115Vdc
1
/12Vdc
pF
Contact Resistance, Maximum ...........................................
Ohms
0.01
0.02
0.50*
Operate Time, Maximum .....................................................
ms
6
6
6
Release Time, Maximum .....................................................
ms
6
6
6
Shock, 11 ms 1/2 Sine ........................................................
G's Peak
50
50
50
Vibration, 10 G’s Peak .........................................................
Hz
55-2000
55-2000
55-2000
Operating Ambient Temperature Range ............................
o
C
-55 to +125
-55 to +125
-55 to +125
Mechanical Life (Operations x 106) ....................................
cycles
2
2
1
Weight, Nominal ..................................................................
oz
1
1
1
* Contact resistance for gas-filled relays is measured at 28 Vdc, 1 amp
25
CII Technologies / P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail [email protected] / website www.ciitech.com