STMICROELECTRONICS HCF40100BM1

HCC/HCF40100B
32-STAGE STATIC LEFT/RIGHT SHIFT REGISTER
..
..
..
.
..
..
FULLY STATIC OPERATION
SHIFT LEFT/SHIFT RIGHT CAPABILITY
MULTIPLE PACKAGE CASCADING
RECIRCULATE CAPABILITY
LIFO OR FIFO CAPABILITY
STANDARDIZED SYMMETRICAL OUTPUT
CHARACTERISTICS
QUIESCENT CURRENT SPECIFIED AT 20V
FOR HCC DEVICE
5V, 10V, AND 15V PARAMETRIC RATINGS
INPUT CURRENT OF 100nA AT 18V AND 25°C
FOR HCC DEVICE
100% TESTED FOR QUIESCENT CURRENT
MEETS ALL REQUIREMENTS OF JEDEC TENo
TATIVE STANDARD N . 13A, ”STANDARD
SPECIFICATIONS FOR DESCRIPTION OF ”B”
SERIES CMOS DEVICES”
DESCRIPTION
The HCC40100B (extended temperature range)
and HCF40100B (intermediate temperature range)
are monolithic integrated circuits, available in 16lead dual in-line plastic or ceramic package and
plastic micro package. The HCC/HCF40100B is a
32-stage shift register containing 32 D-type masterslave flip-flops. The data present at the SHIFTRIGHT INPUT is transferred into the first register
stage synchronously with the positive CLOCK edge,
provided the LEFT/RIGHT CONTROL is at a low
level, the RECIRCULATE CONTROL is at a high
level, and the CLOCK INHIBIT is low. If the
LEFT/RIGHT CONTROL is at a high level and the
RECIRCULATE CONTROL is also high, data at the
SHIFT-LEFT INPUT is transferred into the 32nd register stage synchronously with the positive CLOCK
transition, provided the CLOCK INHIBIT is low. The
state of the LEFT/RIGHT CONTROL, RECIRCULATE CONTROL, and CLOCK INHIBIT should not
be changed when the CLOCK is high. Data is shifted
one stage left or one stage right depending on the
state of the LEFT/RIGHT CONTROL, synchronously with the positive CLOCK edge. Data clocked
into the first or 32nd register states is available at the
SHIFT-LEFT or SHIFT-RIGHT OUTPUT respectively, on the next negative CLOCK transition (see
Data Transfer Table). No shifting occurs on the positive CLOCK edge if the CLOCK INHIBIT line is at a
high level. With the RECIRCULATE CONTROL low,
June 1989
data in the 32nd stage is shifted into the first stage
when the LEFT/RIGHT CONTROL is low and from
the 1st stage to the 32nd stage when the
LEFT/RIGHT CONTROL is high.
EY
(Plastic Package)
M1
(Micro Package)
F
(Ceramic Frit Seal Package)
C1
(Plastic Chip Carrier)
ORDER CODES :
HCC40100BF
HCF40100BM1
HCF40100BEY HCF40100BC1
PIN CONNECTIONS
1/13
HCC/HCF40100B
FUNCTIONAL DIAGRAM
ABSOLUTE MAXIMUM RATINGS
Symbol
V DD *
Parameter
Supply Voltage : HC C Types
H C F Types
Value
Unit
– 0.5 to + 20
– 0.5 to + 18
V
V
Vi
Input Voltage
– 0.5 to V DD + 0.5
V
II
DC Input Current (any one input)
± 10
mA
Total Power Dissipation (per package)
Dissipation per Output Transistor
for T o p = Full Package-temperature Range
200
mW
100
mW
Pto t
T op
Operating Temperature : HCC Types
H CF Types
– 55 to + 125
– 40 to + 85
°C
°C
T stg
Storage Temperature
– 65 to + 150
°C
Stresses above those listed under ”Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress
rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for external periods may affect device
reliability.
RECOMMENDED OPERATING CONDITIONS
Symbol
V DD
VI
Top
2/13
Parameter
Supply Voltage : HC C Types
H CF Types
Input Voltage
Operating Temperature : HCC Types
H CF Types
Value
Unit
3 to + 18
3 to + 15
V
V
0 to V DD
V
– 55 to + 125
– 40 to + 85
°C
°C
HCC/HCF40100B
LOGIC DIAGRAM
3/13
HCC/HCF40100B
TRUTH TABLES
CONTROL
Left/Right Control
Clock
Inhibit
Recirculate
Control
Action
Input Bit Origin
1
0
1
Shift Left
Shift Left Input
1
0
0
Shift Left
Stage 1
0
0
1
Shift Right
Shift Right Input
0
0
0
Shift Right
Stage 32
X
1
X
No Shift
–
DATA TRANSFER
Initial State
Clock
Resulting State
Internal
Stage Q
Output
D ata Input
Clock Inhibit
Internal Stage
Level Change
0
0
X
X
0
0
–
–/
–\
–
–
/
–
–\
–
X
NC
NC
1
0
X
X
0
1
X
1
1
0 = Low level
1 = High level
* For Shift-Right Mode
Data Input = SHIFT-RIGHT INPUT (Pin 11)
Internal Stage = Stage 1 (Q1)
Output = SHIFT-LEFT OUTPUT (Pin 4).
X= Don’t Care.
0
NC
NC
0
1
NC
NC
1
NC = No change.
For Shift-left Mode
Data input = SHIFT LEFT INPUT (Pin 6)
Internal Stage = Stage 32 (Q32)
Output = SHIFT-RIGHT OUTPUT (Pin 12).
STATIC ELECTRICAL CHARACTERISTICS (over recommended operating conditions)
Test Conditions
Symbol
IL
V OH
V OL
Parameter
Quiescent
Current
Output High
Voltage
Output Low
Voltage
VI
(V)
VO
(V)
Value
|I O | V D D
T L o w*
25 °C
T Hi g h *
(µA) (V) Min. Max. Min. Typ. Max. Min. Max.
0/ 5
5
5
0.04
5
150
HCC 0/10
Types 0/15
10
10
0.04
10
300
15
20
0.04
20
600
0/20
20
100
0.08
100
3000
0/ 5
HCF
0/10
Types
0/15
5
20
0.04
20
150
10
40
0.04
40
300
15
80
0.04
80
600
0/ 5
<1
5
4.95
4.95
4.95
0/10
<1
10
9.95
9.95
9.95
0/15
<1
15
14.95
5/0
<1
5
0.05
0.05
0.05
10/0
<1
10
0.05
0.05
0.05
15/0
<1
15
0.05
0.05
0.05
14.95
µA
V
14.95
* TLo w = – 55°C for HCC device : – 40°C for HCF device.
* THigh = + 125°C for HCC device : + 85°C for HCF device.
The Noise Margin for both ”1” and ”0” level is : 1V min. with VDD = 5V, 2V min. with VDD = 10V, 2.5 V min. with VDD = 15V.
4/13
Unit
V
HCC/HCF40100B
STATIC ELECTRICAL CHARACTERISTICS (continued)
Test Conditions
Symbol
V IH
V IL
I OH
I OL
Parameter
VI
(V)
Input High
Voltage
Input Low
Voltage
Output
Drive
Current
Output
Sink
Current
CI
Input
Leakage
Current
|I O | V D D
T L o w*
25 °C
T Hi g h *
(µA) (V) Min. Max. Min. Typ. Max. Min. Max.
0.5/4.5
<1
5
3.5
3.5
3.5
1/9
<1
10
7
7
7
1.5/13.5 < 1
15
11
11
11
<1
5
1.5
1.5
1.5
9/1
<1
10
3
3
3
13.5/1.5 < 1
15
4
2.5
5
– 2
HCC 0/ 5
Types 0/10
4.6
5
9.5
0/15
13.5
0/ 5
0/ 5
HCF
Types 0/10
0/15
0/ 5
HCC
0/10
Types
0/15
0/ 5
HCC 0/18
Types
– 1.15
– 0.64
– 0.51 – 1
– 0.36
10
– 1.6
– 1.3 – 2.6
– 0.9
15
– 4.2
– 3.4 – 6.8
– 2.4
2.5
5
– 1.53
– 1.36 – 3.2
– 1.1
4.6
5
– 0.52
– 0.44 – 1
– 0.36
9.5
10
– 1.3
– 1.1 – 2.6
– 0.9
13.5
15
– 3.6
– 3.0 – 6.8
– 2.4
0.4
5
0.64
0.51
1
0.36
0.5
10
1.6
1.3
2.6
0.9
1.5
15
4.2
3.4
6.8
2.4
0.4
5
0.52
0.44
1
0.36
0.5
10
1.3
1.1
2.6
0.9
1.5
15
3.6
3.0
6.8
2.4
18
± 0.1
±10
–5
15
± 0.3
±10
–5
V
4
– 1.6 – 3.2
± 0.1
mA
mA
± 1
µA
Any Input
HCF 0/15
Types
Input Capacitance
4
Unit
V
4.5/0.5
0/ 5
HCF
0/10
Types
0/15
I IH , I IL
VO
(V)
Value
Any Input
5
± 0.3
± 1
7.5
pF
* TLo w = – 55°C for HCC device : – 40°C for HCF device.
* THigh = + 125°C for HCC device : + 85°C for HCF device.
The Noise Margin for both ”1” and ”0” level is : 1V min. with VDD = 5V, 2V min. with VDD = 10V, 2.5 V min. with VDD = 15V.
DYNAMIC ELECTRICAL CHARACTERISTICS (T amb = 25°C, C L = 50pF, R L = 200kΩ,
typical temperature coefficient for all V DD values is 0.3%/°C, all input rise and fall time = 20ns)
Symbol
t PL H,
t P HL
t T HL ,
tTLH
Parameter
Propagation Delay Time
Clock to Shift Left/Right Output
Transition Time
Test Conditions
Value
V D D (V) Min.
Typ.
Max.
5
360
720
10
165
330
15
115
230
5
100
200
10
50
100
15
40
80
Unit
ns
ns
5/13
HCC/HCF40100B
DYNAMIC ELECTRICAL CHARACTERISTICS (continued)
Symbol
tsetup
thold
tW
tW
fCL
Parameter
Data Setup Time
Data Hold Time
Clock Input Pulse Width Low
Level
Clock Input Pulse Width High
Level
Maximum Clock Input Frequency
WAVEFORMS
6/13
Test Conditions
Value
V DD (V) Min.
Typ.
5
100
50
10
20
10
15
10
5
5
275
170
10
100
75
15
75
50
5
450
225
10
230
115
15
190
95
5
280
140
10
150
75
15
140
70
5
1
2
10
2.5
5
15
3
6
Max.
Unit
ns
ns
ns
ns
MHz
HCC/HCF40100B
Output Low (sink) Current Characteristics.
Output High (source) Current Characteristics.
Typical Propagation Delay Time (clock to shift left
right) vs. Load Capacitance.
Typical Transition Time vs. Load Capacitance.
Typical Dynamic Power Dissipation vs. Clock Frequency .
7/13
HCC/HCF40100B
TEST CIRCUITS
Quiescent Device Current.
Input Leakage Current.
8/13
Input Voltage.
HCC/HCF40100B
Plastic DIP16 (0.25) MECHANICAL DATA
mm
DIM.
MIN.
a1
0.51
B
0.77
TYP.
inch
MAX.
MIN.
TYP.
MAX.
0.020
1.65
0.030
0.065
b
0.5
0.020
b1
0.25
0.010
D
20
0.787
E
8.5
0.335
e
2.54
0.100
e3
17.78
0.700
F
7.1
0.280
I
5.1
0.201
L
Z
3.3
0.130
1.27
0.050
P001C
9/13
HCC/HCF40100B
Ceramic DIP16/1 MECHANICAL DATA
mm
DIM.
MIN.
TYP.
inch
MAX.
MIN.
TYP.
MAX.
A
20
0.787
B
7
0.276
D
E
3.3
0.130
0.38
e3
0.015
17.78
0.700
F
2.29
2.79
0.090
0.110
G
0.4
0.55
0.016
0.022
H
1.17
1.52
0.046
0.060
L
0.22
0.31
0.009
0.012
M
0.51
1.27
0.020
0.050
N
P
Q
10.3
7.8
8.05
5.08
0.406
0.307
0.317
0.200
P053D
10/13
HCC/HCF40100B
SO16 (Narrow) MECHANICAL DATA
mm
DIM.
MIN.
TYP.
A
a1
inch
MAX.
MIN.
TYP.
1.75
0.1
0.068
0.2
a2
MAX.
0.004
0.007
1.65
0.064
b
0.35
0.46
0.013
0.018
b1
0.19
0.25
0.007
0.010
C
0.5
0.019
c1
45° (typ.)
D
9.8
E
5.8
10
0.385
6.2
0.228
0.393
0.244
e
1.27
0.050
e3
8.89
0.350
F
3.8
4.0
0.149
0.157
G
4.6
5.3
0.181
0.208
L
0.5
1.27
0.019
0.050
M
S
0.62
0.024
8° (max.)
P013H
11/13
HCC/HCF40100B
PLCC20 MECHANICAL DATA
mm
DIM.
MIN.
TYP.
inch
MAX.
MIN.
TYP.
MAX.
A
9.78
10.03
0.385
0.395
B
8.89
9.04
0.350
0.356
D
4.2
4.57
0.165
0.180
d1
2.54
0.100
d2
0.56
0.022
E
7.37
8.38
0.290
0.330
e
1.27
0.050
e3
5.08
0.200
F
0.38
0.015
G
0.101
0.004
M
1.27
0.050
M1
1.14
0.045
P027A
12/13
HCC/HCF40100B
Information furnished is believed to be accurate and reliable. However, SGS-THOMSON Microelectronics assumes no responsability for the
consequences of use of such information nor for any infringement of patents or other rights of third parties which may results from its use. No
license is granted by implication or otherwise under any patent or patent rights of SGS-THOMSON Microelectronics. Specifications mentioned
in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied.
SGS-THOMSON Microelectronics products are not authorized for use ascritical components in life support devices or systems without express
written approval of SGS-THOMSON Microelectonics.
 1994 SGS-THOMSON Microelectronics - All Rights Reserved
SGS-THOMSON Microelectronics GROUP OF COMPANIES
Australia - Brazil - France - Germany - Hong Kong - Italy - Japan - Korea - Malaysia - Malta - Morocco - The Netherlands Singapore - Spain - Sweden - Switzerland - Taiwan - Thailand - United Kingdom - U.S.A
13/13