ETC HF8509-324

HF8509
HIGH POWER LATCHING RELAY
Features
• 60
A switching capabilities
• 4KV
dielectric coil to contacts
• Heavy
load up to 15000VA
• SPST
configurations
File No.:CH0013854-99
COIL
CONTACT DATA
1A
Contact Arrangement
Initial Contact
Resistance
Single Coil: 1.0W
Double Coil: 2.0W
50m (at 1A 24VDC)
AgCdO
Contact Material
General Purpose Power Relays HF8509
Contact Rating
(Res. Load)
Coil power
60A 250VAC 50A 250VAC 40A 250VAC
5000 OPS
10000 OPS 100000 OPS
Max. switching voltage
250VAC
Max. switching current
60A
Max. switching power
COIL DATA
Nominal Pick-up
Pulse
Voltage Voltage
Duration
VDC VDC(max.) ms (min.)
5
3.5
50
24
6
4.2
50
35
9
6.3
50
15000VA
Mechanical life
1 x 106 OPS
Electrical life
1 x 105 OPS
Coil Resistance
80
Single
Coil
12
8.4
50
145
24
16.8
50
575
48
33.6
50
2270
5
3.5
50
2 x 12
6
4.2
50
2 x 17.5
9
6.3
50
12
8.4
50
2 x 72
24
16.8
50
2 x 285
48
33.6
50
2 x 1135
CHARACTERISTICS
Initial Insulation Resistance
Dielectric Between coil and Contacts
Strength
Between open contacts
1000M , 500 VDC
4000VAC, 1min.
1500VAC, 1min.
Creepage Distance
8mm
Operate time (at nomi. Volt.)
20ms
Release time (at nomi. Volt.)
Shock Resistance
Vibration Resistance
Humidity
20ms
Functional
98m/s2
Destructive
980m/s2
DA:1.5mm, 10 to 55Hz
98%, +40
Ambient temperature
Termination
-40
to +70
PCB & QC
Unit weight
Approx. 33g
Construction
Sealed & Dust Cover
HONGFA RELAY
ISO9001/QS9000/ISO14000 CERTIFIED
146
Double
Coil
Notes:When requiring other nominal voltage, special order allowed.
2 x 40
ORDERING INFORMATION
HF8509-1 /
012
S
HF8509-1: Single Coil
HF8509-2: Single Coil HF8509-3: Double Coil
Type
Coil voltage
Structure
5, 6, 9, 12, 24, 48VDC
Nil: Unsealed
S: Sealed
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Outline Dimensions
PCB layout
19.08
21.59
25.4
21.59
25.4
2.8
2.8
2.8
General Purpose Power Relays HF8509
3.5
Ø1.2
Ø1.2
16
9
19.08
25.4
Mounting Terminal
Ø3.5
Ø1.2
0.64x0.64
5.08
5.08
HF8509-1
2.54
2.54
HF8509-2
2.54
HF8509-3
38
Mounting Terminal
Mounting Terminal
Mounting Terminal
SET Polarity
RESET
Polarity
SET Polarity
0.8
8
SET Coil
(the contact close)
RESET
(the contact open)
CONTACT: 60A 250VAC
8.8
30
HF8509-1
COIL: 12VDCX
RESET Polarity
HF8509-1
HF8509-2
HF8509-3
1
The solder direction of
twisted copper wire(A to I)
C
G
B
A
D
H
E
F
I
Notes: W e l d i n g p i c t u r e s f o r H F 8 5 0 9 w i t h
twisting copper wire. Please show welding style
( A to I ) and the length of wires when ordering.
Please mark the length of each wire from left to
right if the length is different.
147