ETC HFM1300-331

HFM1300
Ethernet Receiver
FIBER-86.TIF
FEATURES
• -34 dBm to -11 dBm sensitivity
• Differential data outputs (ECL compatible)
• Signal Quality Detect and Packet Detect outputs
(open collector)
• Adjustable signal quality detect level

• ST interface
• 500 Ω output drive capability
• Monolithic design - less board space, high
reliability
• Singlemode version
DESCRIPTION
The HFM1300 Ethernet fiber optic receiver module is
designed for use in computer LAN (10 Mb/s Ethernet)
applications. The 16 pin DIP module is intended for use
in applications such as IEEE 802.3 10BASEFA and
FOIRL signal standards in reasonable operating
environment. A PIN photodiode plus pre-amp is
mounted in the fiber optic connector for maximum
shielding, and provides amplification and
current-to-voltage conversion. The post-amp IC provides
final amplification to the logic output levels (see BLOCK
DIAGRAM). Signal Quality Detect, Packet Detect and
Differential Data outputs in both ST and SMA versions
are available. Differential ECL compatible data
minimizes pulse width distortion and allows capacitive
coupling to ECL logic. The HFM1300 has a 500 Ω
output drive capability on each data output. An internally
regulated power supply increases power supply
rejection.
Case ground is separated from circuit ground, allowing
feedthrough mounting of the barrel.
REF.
FIBER-26.DIM
APPLICATION
Average-to-peak input level monitoring aids in the
generation of the signal quality logic signal (SQ) when
the input level is adequate for 10-10 BER. The open
collector output timing response of SQ is intended to
meet 802.3 requirements over -32 dBm to -11 dBm
average power levels. An additional current source
output (SQLED) is available to drive an external LED
indicator (LED ON indicates poor signal quality). If this
output is not used, it should be tied to +12 V.
OUTLINE DIMENSIONS in inches
Notes
1.
ST is a registered trademark of AT & T.
Resistor Radj adjusts the SQ threshold upward. A 70 µA
current from this node to ground increases the threshold
by 1 dB of optical power. Radj’s high side is at 4.3 V
(nominal).
548
Honeywell reserves the right to make
changes in order to improve design and
supply the best products possible.
HFM1300
Ethernet Receiver
APPLICATION (continued)
The open collector output (PKT) indicates presence of a
valid Ethernet packet. This output goes low following the
first two data edges that are 200 ns or less apart at the
start of a packet. It returns high before the end of the
first half cycle of a valid 1 MHz idle signal.
The HFM1300 is designed to operate with a 12 V supply
(normally present in FOIRL interfaces and personal
computer backplanes). The module requires a minimum
+8.5 V total voltage. If a +12 V supply is not available,
+5 V to VCC pin and -5 V to GND pin will operate the
module. Since the outputs are typically AC coupled, this
voltage shift is generally not a problem.
The HONEYWELL HFM1300 module is designed to
work with SINGLEMODE fibers. Final testing is
performed with 10 m 9/125 µm fiber.
Honeywell reserves the right to make
changes in order to improve design and
supply the best products possible.
549
HFM1300
Ethernet Receiver
ELECTRO-OPTICAL CHARACTERISTICS (Over 0 to 70°C, VCC = 11.25 to 15.75 VDC unless otherwise noted)
PARAMETER
Data Rate
Input Power
Supply Current
Propagation Delay
Jitter (uncorrelated)
Pulse Width Distortion
SYMBOL
MIN
-34
32
28
0.35
Signal Quality Detect (SQ)
3.0
Delay of Packet Start
End of Packet Delay
Optical Idle Signal
Frequency
Duty Cycle
Output (Out1/Out2)
Load
Output Swing
-11
43
40
0.5
4.0
UNITS
Mbd
dBm
mA
ns
ns
ns
4.0
20.0
dBm
average
µs
µs
TEST CONDITIONS
Manchester coding
Average power (10-10 BER)
Excluding SQ, SQLED, PKT
RMS, -32 dBm average input
SQ Low, -11 dBm average
input
Threshold for 10-10 BER
PIN > -32 dBm average
PIN < -11 dBm average
Bit times @ 10 Mbd (with
< 20 pF and 4 kΩ load)
2.0
4.0
0.85
45
500
1.0
SQ/PKT VOL
SQLED Sink Current
1.0
1.25
55
1.6
+1000
0.4
12.0
ABSOLUTE MAXIMUM RATINGS
(25°C Free-Air Temperature unless otherwise noted)
8.5 to 15.75 V
-40 to +85°C
Notes
Stresses greater than those listed under "Absolute Maximum
Ratings" may cause permanent damage to the device. This is a
stress rating only and functional operation of the device at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods of time may
affect reliability.
550
MAX
-35
Delay Time (acceptable level)
Delay Time (unacceptable level)
Packet Detection (PKT)
Supply voltage (VCC)
Temperature
TYP
10
MHz
%
Ω
V
ppm/°C
V
mA
PKT signal detection
Peak to peak
Over temperature
IOL ≤ 3 mA
RECOMMENDED OPERATING CONDITIONS
Supply voltage (VCC)
Temperature
11.25 to 12.75 V
0 to +70°C
ORDER GUIDE
Description
Fiber optic Ethernet receiver, 16 pin
DIP ST package
Catalog Listing
HFM1300-331
Honeywell reserves the right to make
changes in order to improve design and
supply the best products possible.
HFM1300
Ethernet Receiver
BLOCK DIAGRAM
CABLE ORDERING INFORMATION
HOC 0009 - 150 m
Core Dia. 9 µm
Length in meters
Any length (full meters only) up to 1000 m, terminated
with ST Type - connectors is available.
Other Fiber Optic cables on request.
FIBER--9.SCH
CAUTION: The inherent design of this component
causes it to be sensitive to electrostatic discharge
(ESD). To prevent ESD-induced damage and/or
degradation to equipment, take normal ESD
precautions when handling this product.
RADJ = 10 kΩ TO 40 kΩ IF HIGHER THRESHOLD (SQ)IS
NEEDED
SQ Transition Delay vs Power
Fig. 2
Spectral Responsivity
FIBER-73.GRA
Fig. 1
FIBER-74.GRA
FIBER-12.CIR
TYPICAL CIRCUIT CONFIGURATION
All Performance Curves Show Typical Values
Honeywell reserves the right to make
changes in order to improve design and
supply the best products possible.
551