HONEYWELL HIH-4031-001S

HIH-4030/31 Series
Humidity Sensors
DESCRIPTION
The HIH-4030/4031 Series delivers instrumentation-quality RH
Honeywell has expanded our HIH Series to include an SMD
(Relative Humidity) sensing performance in a competitively
(Surface Mount Device) product line: the new HIH 4030/4031.
priced, solderable SMD.
The HIH 4030/4031 complements our existing line of non-SMD
humidity sensors. SMD packaging on tape and reel allows for
The HIH-4030 is a covered integrated circuit humidity sensor.
use in high volume, automated pick and place manufacturing,
The HIH-4031 is a covered, condensation-resistant, integrated
eliminating lead misalignment to printed circuit board through-
circuit humidity sensor that is factory-fitted with a hydrophobic
hole.
filter allowing it to be used in condensing environments
including industrial, medical and commercial applications.
The HIH-4030/4031 Series Humidity Sensors are designed
specifically for high volume OEM (Original Equipment
The RH sensor uses a laser trimmed, thermoset polymer
Manufacturer) users.
capacitive sensing element with on-chip integrated signal
conditioning.
Direct input to a controller or other device is made possible by
this sensor’s near linear voltage output. With a typical current
The sensing element's multilayer construction provides
draw of only 200 μA, the HIH-4030/4031 Series is often ideally
excellent resistance to most application hazards such as
suited for low drain, battery operated systems.
condensation, dust, dirt, oils and common environmental
chemicals.
Tight sensor interchangeability reduces or eliminates OEM
production calibration costs. Individual sensor calibration data
Sample packs are available. See order guide.
is available.
FEATURES
POTENTIAL APPLICATIONS
•
Tape and reel packaging allows for use in high volume pick
•
Refrigeration equipment
and place manufacturing (1,000 units per tape and reel)
•
HVAC (Heating, Ventilation and Air Conditioning)
•
Molded thermoset plastic housing
•
Near linear voltage output vs %RH
•
Medical equipment
•
Laser trimmed interchangeability
•
Drying
•
Low power design
•
Metrology
•
Enhanced accuracy
•
Battery-powered systems
•
Fast response time
•
OEM assemblies
•
Stable, low drift performance
•
Chemically resistant
equipment
HIH-4030/31 Series
TABLE 1. PERFORMANCE SPECIFICATIONS (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.)
Parameter
Minimum
Typical
Maximum
Unit
Specific
Note
–
–
–
1
–
–
–
–
2
3
4
–
Interchangeability (first order curve)
–
–
–
–
0% RH to 59% RH
-5
5
% RH
–
60% RH to 100% RH
-8
8
% RH
–
Accuracy (best fit straight line)
-3.5
–
+3.5
% RH
Hysterisis
3
% RH
–
–
Repeatability
±0.5
% RH
–
–
Settling time
70
ms
–
–
Response time (1/e in slow moving air)
5
s
–
–
Stability (at 50% RH in a year)
±1.2
%
RH
–
–
Stability (at 50% RH in a year)
±0.5
% RH
–
–
Voltage supply
4
5.8
Vdc
–
Current supply
200
500
μA
–
st
Voltage output (1 order curve fit)
VOUT=(VSUPPLY)(0.0062(sensor RH) + 0.16), typical at 25 ºC
Temperature compensation
True RH = (Sensor RH)/(1.0546 – 0.00216T), T in ºC
Output voltage temp. coefficient at 50% RH, 5 V
mV/ºC
–
-4
–
–
Operating temperature
-40[-40]
See Figure 1.
85[185]
ºC[ºF]
–
Operating humidity (HIH-4030)
0
See Figure 1.
100
% RH
5
Operating humidity (HIH-4031)
0
See Figure 1.
100
% RH
–
Storage temperature
-50[-58]
125[257]
ºC[ºF]
–
–
Storage humidity
See Figure 2.
% RH
5
Specific Notes:
General Notes:
1. Can only be achieved with the supplied slope and offset. For
• Sensor is ratiometric to supply voltage.
HIH-4030/31-003 catalog listings only.
• Extended exposure to >90% RH causes a reversible
2. Includes testing outside of recommended operating zone.
shift of 3% RH.
3. Includes testing for recommended operating zone only.
• Sensor is light sensitive. For best performance, shield
4. Device is calibrated at 5 Vdc and 25 ºC.
sensor from bright light.
5. Non-condensing environment. When liquid water falls on the
humidity sensor die, output goes to a low rail condition
indicating no humidity.
FACTORY CALIBRATION DATA
HIH-4030/31 Sensors may be ordered with a calibration and
data printout. See Table 2 and the order guide on the back
page.
TABLE 2. EXAMPLE DATA PRINTOUT
Model
HIH-4030-003
Channel
92
Wafer
030996M
MRP
337313
Calculated values at 5 V
0.958 V
VOUT at 0% RH
3.268 V
VOUT at 75.3% RH
Linear output for 3.5% RH
accuracy at 25 °C
Zero offset
0.958 V
Slope
30.680 mV/%RH
Sensor RH
(VOUT - zero offset)/slope
(VOUT - 0.958)/0.0307
Ratiometric response for
0% RH to 100% RH
VOUT
VSUPPLY (0.1915 to 0.8130)
2
www.honeywell.com/sensing
Humidity Sensors
FIGURE 1. OPERATING ENVIRONMENT (Non-condensing environment for HIH-4030 catalog listings only.)
FIGURE 2. STORAGE ENVIRONMENT (Non-condensing environment for HIH-4030 catalog listings only.)
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
-40
-20
Recommended storage zone
0
20
40
60
80
100
120
140
Temperature ºC
Honeywell Sensing and Control
3
HIH-4030/31 Series
FIGURE 3. TYPICAL OUTPUT VOLTAGE VS RELATIVE HUMIDITY (At 25 ºC and 5 V.)
4
3.5
Output Voltage (Vdc)
3
2.5
Sensor Response
Sensor Response
Best Linear Fit
2
1.5
1
0.5
0
20
40
60
80
100
Relative Humidity (%RH)
FIGURE 4. TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (At 0 ºC, 70 ºC and 5 V.)
4.5
4
3.5
Output Voltage (Vdc)
3
2.5
0C
70 C
2
1.5
1
0.5
0
0
10
20
30
40
50
60
Relative Humidity (%)
4
www.honeywell.com/sensing
70
80
90
100
Humidity Sensors
FIGURE 5. HIH-4030 MOUNTING DIMENSIONS (For reference only. mm/[in])
Honeywell Sensing and Control
5
HIH-4030/31 Series
FIGURE 6. HIH-4031 MOUNTING DIMENSIONS (For reference only. mm/[in])
FIGURE 7. HIH-4031 PCB LANDING PATTERN (For reference only. mm/[in])
6
www.honeywell.com/sensing
Humidity Sensors
FIGURE 8. TAPE AND REEL DIMENSIONS (For reference only. mm/[in])
3,99
[0.157]
DIA. 1,50
[0.059]
2,01
[0.079]
2,64
[0.104]
1,75
[0.069]
3,91
[0.154]
11,51
[0.453]
24,00
[0.945]
2,64
[0.076]
22,25
[0.876]
DIA. 1,50
[0.059]
8,00
[0.315]
0,343
[0.0135]
FIGURE 9. TYPICAL APPLICATION CIRCUIT
ORDER GUIDE
Catalog Listing
HIH-4030-001
HIH-4030-003
HIH-4031-001
HIH-4031-003
HIH-4030-001S
HIH-4030-003S
HIH-4031-001S
HIH-4031-003S
Description
Covered integrated circuit humidity sensor, SMD, 1000 units on tape and reel
Covered integrated circuit humidity sensor, SMD, calibration and data printout, 1000 units on tape and reel
Covered, filtered integrated circuit humidity sensor, SMD, 1000 units on tape and reel
Covered, filtered integrated circuit humidity sensor, SMD, calibration and data printout, 1000 units on tape
and reel
Sample pack: covered integrated circuit humidity sensor, SMD, five units on tape
Sample pack: covered integrated circuit humidity sensor, SMD, calibration and data printout, five units on
tape
Sample pack: covered, filtered integrated circuit humidity sensor, SMD, sample pack, five units on tape
Sample pack: covered, filtered integrated circuit humidity sensor, SMD, calibration and data printout, five
units on tape
FURTHER HUMIDITY SENSOR INFORMATION
See the following associated literature is available on the Web:
• Product installation instructions
• Application sheets:
– Humidity Sensor Performance Characteristics
– Humidity Sensor Theory and Behavior
– Humidity Sensor Moisture and Psychrometrics
– Thermoset Polymer-based Capacitive Sensors
Honeywell Sensing and Control
7
WARNING
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
• Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result
in death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result
in death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: [email protected]
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America
+1-305-805-8188
+1-305-883-8257 Fax
USA/Canada
+1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 55422
www.honeywell.com/sensing
009021-4-EN IL50 GLO Printed in USA
March 2008
© 2008 Honeywell International Inc. All rights reserved.