HONEYWELL SS345PT

DESCRIPTION
The 2.7 Vdc to 7 Vdc supply voltage range allows this device
The SS345PT/SS445P sensors are small, versatile digital Hall-
to be used in low voltage applications. The SS345PT’s very
effect devices that are operated by the magnetic field from a
small size requires less PCB (printed circuit board) space,
permanent magnet or an electromagnet, designed to respond
allowing it to be used in smaller assemblies.
to a single North pole (SS345PT) or South pole (SS445P).
These sensors are available in two package styles: the
These unipolar sensors are designed to meet the requirements
SS345PT in the subminiature SOT-23 surface mount package;
of a wide range of potential applications. The internal pull-up
the SS445P is available in the leaded, flat TO-92-style
resistor often eliminates the need for external components,
package.
further helping to reduce the system cost. These economical
unipolar sensors are well suited for simple, high-volume, costsensitive position and motion sensing applications.
FEATURES
Subminiature package size (SS345PT) uses less space on
the PCB than standard Hall-effect sensor packages such as
TO-92 or SOT-89, allowing for use in smaller assemblies
Tape and reel packaging (SS345PT) allows for automated
component placement, helping to reduce manufacturing
costs
Small, flat TO-92-style package (SS445P) is also available
Simple activation from a North pole (SS345PT) or a South
pole (SS445P) makes these products suitable in a variety
of potential applications such as motion control, lid closure
detection, and displacement sensing
Built-in pull-up resistor can easily interface with common
electronic circuits without adding external components,
helping to reduce total system cost
RoHS-compliant materials meet Directive 2002/95/EC
The SS345PT is available on tape and reel (3000 units per
reel); the SS445P is available in a bulk package (1000 units
per bag).
POTENTIAL APPLICATIONS
Commercial:
Door or lid closure detection in appliances
Speed and RPM sensing in fitness equipment
Flow rate sensing in appliances and water softeners
Damper or valve position control in HVAC equipment
Printer head position sensing
Industrial
Flow rate sensing in industrial processes
Robotic control (cylinder position monitoring)
Float-based fluid level sensing
Medical
Displacement sensor in hospital beds and medical
equipment
Medication bin monitor on portable drug carts
Table 1. SS345PT/SS445P Specifications (At 2.7 to 7 Vdc supply, 4 mA load, TA = -40 ºC to 150 ºC [-40 ºF to 302 ºF]
Characteristic
Condition
Minimum
Typical
Maximum
Unit
Supply voltage
-40 °C to 150 °C [-40 °F to 302 °F]
2.7
5.0
7.0
Vdc
Supply current
G < 25 , Vs = 5 V, 25 °C [77°F]
–
5.5
–
mA
-40 °C to 150 °C [-40 °F to 302 °F]
–
–
14
Output current
–
–
–
4.0
mA
Vsat
G > 260
–
–
0.4
Vdc
Output leakage current
G < 25
–
–
10
µA
Output rise time
–
–
1.5
25 °C [77 °F]
µs
Output fall time
–
–
1.5
Thermal resistance:
–
–
303
–
SS345PT
°C/W
–
233
–
SS445P
Operate
Release
Differential
Operating temperature
Storage temperature
-40 °C to 150 °C [-40 °F to 302 °F]
-40 °C to 150 °C [-40 °F to 302 °F]
-40 °C to 150 °C [-40 °F to 302 °F]
–
–
55
25
10
-40 [-40]
-55 [-67]
180
105
75
–
–
280
240
140
150 [302]
165 [329]
G
G
G
°C [°F]
°C [°F]
NOTICE
The magnetic field strength required to cause the switch to change state (operate and
release) will be as specified in the magnetic characteristics. To test the switch against the
specified magnetic characteristics, the switch must be placed in a uniform magnetic field.
Table 2. SS345PT/SS445P Absolute Maximum Ratings1
Characteristic
Minimum
Supply voltage
-0.5
Applied output voltage
-0.5
Output current
–
Magnetic flux
–
Typical
–
–
–
–
Maximum
7.0
7.0
8.0
no limit
Unit
V
V
mA
G
Note 1: Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and
mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the
device necessarily operate at absolute maximum ratings.
Figure 1. SS345PT/SS445P Current Sinking Output Block
Diagram
2
www.honeywell.com/sensing
Figure 2. Typical SS345PT/SS445P Magnetic
Performance vs Temperature
Figure 3. SS345PT Mounting/Tape and Reel Dimensions (For reference only. mm/[in])
Figure 4. SS445P Mounting Dimensions (For reference only. mm/[in])
Honeywell Sensing and Control
3
Order Guide
Catalog Listing
SS345PT
SS445P
Description
Unipolar, Hall-effect digital position sensor with built-in pull-up resistor, SOT-23 package, tape and reel
packaging (3000 units per reel)
Unipolar, Hall-effect digital position sensor with built-in pull-up resistor, flat TO-92 package, bulk packaging
(1000 units per bag)
WARNING
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result
in death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. DO NOT USE this document as a
product installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result
in death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: [email protected]
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America
+1-305-805-8188
+1-305-883-8257 Fax
USA/Canada
+1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com/sensing
005921-1-EN IL50 GLO Printed in USA
December 2009
© 2009 Honeywell International Inc. All rights reserved.