MURATA-PS HL01U05D05

D
E
NU
I
T
N
O
Product Data Sheet
C
S
DI
1 WATT UNREGULATED
DC/DC CONVERTER
HL01U
FEATURES
L LOW COST
L
INTERNAL FILTERING
L SURFACE MOUNT CONSTRUCTION
L
TEMPERATURE RANGE: -25°C TO +70°C
L HIGH EFFICIENCY
L
NON-CONDUCTIVE CASE
L
SURFACE MOUNT PACKAGE (SMD)
DESCRIPTION
manufacturing technologies.
The HL01U Series offers an extensive selection of input and
output voltages to choose from. These miniature, unregulated
DC/DC converters come in 24-pin DIP and SMD packages.
This small size is possible through the use of surface mount
The HL01U Series utilizes a 125KHz push-pull oscillator in the
input stage with internal filtering to reduce the output noise.
ABSOLUTE MAXIMUM RATINGS
ORDERING INFORMATION
Internal Power Dissipation..................................................................30 Sec
Short Circuit Duration..................................................................Momentary
Lead Temperature (soldering, 10 seconds max)..............................+300°C
*
* Note: Refer to Reflow Profile for SMD Models.
HL01U revE, 12/08
The use of surface mount construction and automated manufacturing processes increase consistency and reliability while
reducing overall cost.
HL01U xxyzz Y/Z /H
Device Family
HL Indicates DC/DC Converter
Model Number
Where:
xx = Input Voltage
y = Number or Outputs (Single "S", Dual "D")
zz = Output Voltage
Package Option
Screening Option
DIP Package only
Page 1
ELECTRICAL
SPECIFICATIONS
Specifications typical at T = +25°C, nominal input voltage, rated output current unless otherwise specified.
A
NOMINAL
RATED
INPUT
MODEL
RATED
OUTPUT
VOLTAGE VOLTAGE
INPUT CURRENT
OUTPUT
CURRENT
NO LOAD
RATED LOAD
(mA)
EFFICIENCY
(VDC)
(VDC)
(mA)
(mA)
(%)
HL01U05S05
HL01U05S12
HL01U05S15
5
5
5
5
12
15
200
83
67
30
30
30
300
260
260
70
74
74
HL01U12S05
HL01U12S12
HL01U12S15
12
12
12
5
12
15
200
83
67
25
25
25
120
120
120
67
70
70
HL01U15S05
HL01U15S12
HL01U15S15
15
15
15
5
12
15
200
83
67
20
20
20
100
100
100
67
70
70
HL01U24S05
HL01U24S12
HL01U24S15
24
24
24
5
12
15
200
83
67
15
15
15
65
65
65
67
70
70
HL01U05D05
HL01U05D12
HL01U05D15
5
5
5
±5
±12
±15
±100
±41
±33
30
30
30
300
260
260
70
74
74
HL01U12D05
HL01U12D12
HL01U12D15
12
12
12
±5
±12
±15
±100
±41
±33
25
25
25
120
120
120
67
70
70
HL01U15D05
HL01U15D12
HL01U15D15
15
15
15
±5
±12
±15
±100
±41
±33
20
20
20
100
100
100
67
70
70
HL01U24D05
HL01U24D12
HL01U24D15
24
24
24
±5
±12
±15
±100
±41
±33
15
15
15
65
65
65
67
70
70
MIN
TYP
MAX
UNITS
4.5
10.8
13.5
22.6
5
12
15
24
30
5.5
13.2
16.5
26.4
100
VDC
COMMON
SPECIFICATIONS
Specifications typical at T = +25°C, nominal input voltage, rated output current unless otherwise specified.
A
PARAMETER
CONDITIONS
INPUT
Voltage Range
Reflected Ripple Current
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Temperature Coefficent
Ripple & Noise
Line Regulation
Load Regulation
5 Vout Models
All Others
GENERAL
Switching Frequency
Package Weight
MTTF per MIL-HDBK-217, Rev. F
Ground Benign
TEMPERATURE
Specification
Operation
Storage
Page 2
60 Hz, 10 Seconds
500
500
VDC
mAp-p
VDC
Vpk
G7
pF
μArms
VISO= 240VAC, 60Hz
1
25
2
BW = DC to 10MHz
BW =10Hz to 2MHz
High Line to Low Line
1
±3
±0.02
50
10
1
±1.5
W
%
%/°C
mVp-p
mVrms
%/%
25% Rated Load to Rated Load
10% Rated Load to Rated Load
±5
±3
±10
±10
%
%
Circuit Stress Method
TA = +25°C
TA = +70°C
-25
-40
-40
±5
100
125
12
kHz
g
1100
550
kHr
kHr
+70
+85
+110
°C
°C
°C
HL01U revE,12/08
MECHANICAL
Package/Pinout "Y" and "Z"
TOP VIEWS
HL01UxxyzzY
HL01UxxyzzZ
SIDE VIEWS
END VIEWS
DIP PACKAGE
SMD PACKAGE
NU = Do Not Use.
NC = No Internal Connection.
Duplicate pin functions are internally connected.
All dimensions are in inches (millimeters).
GRID: 0.100 inches (2.54 millimeters)
Typically Marked with: specific model ordered, date
code, job code and Logo.
RECOMMENDED LAND PATTERN
HL01U revE, 12/08
PIN CONNECTIONS
PIN#
SINGLES
DUALS
1
2
3
+VIN
NU
NU
+VIN
-VOUT
Common
10
11
12
-VOUT
+VOUT
-VIN
Common
+VOUT
-VIN
13
14
15
-VIN
+VOUT
-VOUT
-VIN
+VOUT
Common
22
23
24
NU
NU
+VIN
Common
-VOUT
+VIN
RECOMMENDED REFLOW PROFILE
Page 3
TYPICAL PERFORMANCE CURVES
SAFE OPERATING AREA
NOTES:
1.) When operated within the SAFE OPERATING AREA as defined
by the above curves, the output voltage of HL01U devices is
guaranteed to be within 95% of its steady-state value within 100
milliseconds after the input voltage has reached 95% of its steadystate value.
2.)
For dual output models, total load capacitance is the sum
of the capacitances on the plus and minus outputs.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
USA:
Mansfield (MA), Tel: (508) 339 3000, email: [email protected]
Canada:
Toronto, Tel: (866) 740 1232, email: [email protected]
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany: München, Tel: +49 (0)89-544334-0, email: [email protected]
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
www.murata-ps.com email: [email protected] ISO 9001 & ISO 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
Page 4
Singapore: Parkway Centre, Tel: +65 6348 9096, email: [email protected]
HL01U revE,12/08