3-Axis Digital Compass IC HMC5883L Advanced Information The Honeywell HMC5883L is a surface-mount, multi-chip module designed for low-field magnetic sensing with a digital interface for applications such as lowcost compassing and magnetometry. The HMC5883L includes our state-of-theart, high-resolution HMC118X series magneto-resistive sensors plus an ASIC containing amplification, automatic degaussing strap drivers, offset cancellation, 2 and a 12-bit ADC that enables 1° to 2° compass heading accuracy. The I C serial bus allows for easy interface. The HMC5883L is a 3.0x3.0x0.9mm surface mount 16-pin leadless chip carrier (LCC). Applications for the HMC5883L include Mobile Phones, Netbooks, Consumer Electronics, Auto Navigation Systems, and Personal Navigation Devices. The HMC5883L utilizes Honeywell’s Anisotropic Magnetoresistive (AMR) technology that provides advantages over other magnetic sensor technologies. These anisotropic, directional sensors feature precision in-axis sensitivity and linearity. These sensors’ solid-state construction with very low cross-axis sensitivity is designed to measure both the direction and the magnitude of Earth’s magnetic fields, from milli-gauss to 8 gauss. Honeywell’s Magnetic Sensors are among the most sensitive and reliable low-field sensors in the industry. FEATURES BENEFITS 3-Axis Magnetoresistive Sensors and ASIC in a 3.0x3.0x0.9mm LCC Surface Mount Package Size for Highly Integrated Products. Just Add a Micro Small Controller Interface, Plus Two External SMT Capacitors 12-Bit ADC Coupled with Low Noise AMR Sensors Achieves 5 milli-gauss Resolution in ±8 Gauss Fields Enables 1° to 2° Degree Compass Heading Accuracy Built-In Self Test Enables Low-Cost Functionality Test after Assembly in Production Low Voltage Operations (2.16 to 3.6V) and Low Power Consumption (100 μA) Compatible for Battery Powered Applications Built-In Strap Drive Circuits and Offset Strap Drivers for Degaussing, Self Test, and Set/Reset Offset Compensation I C Digital Interface Popular Two-Wire Serial Data Interface for Consumer Electronics Lead Free Package Construction RoHS Compliance Wide Magnetic Field Range (+/-8 Oe) Can Be Used in Strong Magnetic Field Environments with a Sensors 1° to 2° Degree Compass Heading Accuracy Software and Algorithm Support Available Heading, Hard Iron, Soft Iron, and Auto Calibration Compassing Libraries Available Fast 160 Hz Maximum Output Rate Enables Pedestrian Navigation and LBS Applications 2 Designed for High Volume, Cost Sensitive OEM Designs Easy to Assemble & Compatible with High Speed SMT Assembly HMC5883L SPECIFICATIONS (* Tested at 25°C except stated otherwise.) Characteristics Conditions* Min VDD Referenced to AGND 2.16 VDDIO Referenced to DGND 1.71 Idle Mode Measurement Mode (7.5 Hz ODR; Typ Max Units 3.6 Volts 1.8 VDD+0.1 Volts - 2 - μA - 100 - μA Power Supply Supply Voltage Average Current Draw No measurement average, MA1:MA0 = 00) VDD = 2.5V, VDDIO = 1.8V Performance Full scale (FS) – total applied field (Typical) -8 +8 gauss Mag Dynamic Range 3-bit gain control ±1 ±8 gauss Resolution VDD=3.0V, GN=2 Field Range 5 milli-gauss Linearity ±2.0 gauss input range Hysteresis ±2.0 gauss input range ±25 ppm Test Conditions: Cross field = 0.5 gauss, Happlied = ±3 gauss ±0.2% %FS/gauss Cross-Axis Sensitivity Output Rate (ODR) Continuous Measurment Mode 0.1 0.75 75 Single Measurement Mode Measurement Period Turn-on Time Gain Tolerance 2 I C Address msec Ready for I2C commands 200 μs All gain/dynamic range settings ±5 % 7-bit address 0x1E hex 8-bit read address 0x3D hex 8-bit write address 0x3C hex Controlled by I C Master Hysteresis of Schmitt trigger inputs on SCL Self Test Hz 6 2 I C Hysteresis Hz From receiving command to data ready 2 I C Rate 160 ±% FS 2 400 kHz and SDA - Fall (VDDIO=1.8V) 0.2*VDDIO Volts Rise (VDDIO=1.8V) 0.8*VDDIO Volts X & Y Axes ±1.16 gauss Z Axis ±1.08 X & Y Axes (GN=100) 510 LSb Z Axis (GN=100) General ESD Voltage Operating Temperature 2000 CDM 750 Volts Ambient -30 85 °C Storage Temperature Ambient, unbiased -40 125 °C Reflow Classification MSL 3, 260 C Peak Temperature Package Size Package Height 2 Human Body Model (all pins) Length and Width 2.85 3.00 3.15 mm 0.8 0.9 1.0 mm www.honeywell.com HMC5883L Absolute Maximum Ratings (* Tested at 25°C except stated otherwise.) Characteristics Min Max Units Supply Voltage VDD -0.3 4.8 Volts Supply Voltage VDDIO -0.3 4.8 Volts PIN CONFIGURATIONS Pin Name 1 2 3 4 5 SCL VDD NC S1 NC Serial Clock – I C Master/Slave Clock Power Supply (2.16V to 3.6V) Not to be Connected Tie to VDDIO Not to be Connected Description 6 7 8 9 10 11 NC NC SETP GND C1 GND Not to be Connected Not to be Connected Set/Reset Strap Positive – S/R Capacitor (C2) Connection Supply Ground Reservoir Capacitor (C1) Connection Supply Ground 12 13 14 SETC VDDIO NC 15 DRDY 16 SDA S/R Capacitor (C2) Connection – Driver Side IO Power Supply (1.71V to VDD) Not to be Connected Data Ready, Interrupt Pin. Internally pulled high. Optional connection. Low for 250 µsec when data is placed in the data output registers. 2 Serial Data – I C Master/Slave Data 2 Table 1: Pin Configurations Arrow indicates direction of magnetic field that generates a positive output reading in Normal Measurement configuration. www.honeywell.com 3 HMC5883L PACKAGE OUTLINES PACKAGE DRAWING HMC5883L (16-PIN LPCC, dimensions in millimeters) MOUNTING CONSIDERATIONS The following is the recommend printed circuit board (PCB) footprint for the HMC5883L. 1.275 0.450 1.275 0.300 3.000 0.500 x 12 0.100 x 8 3.000 HMC5883 Land Pad Pattern (All dimensionsare in mm) 4 www.honeywell.com HMC5883L PCB Pad Definition and Traces The HMC5883L is a fine pitch LCC package. Refer to previous figure for recommended PCB footprint for proper package centering. Size the traces between the HMC5883L and the external capacitors (C1 and C2) to handle the 1 ampere peak current pulses with low voltage drop on the traces. Stencil Design and Solder Paste A 4 mil stencil and 100% paste coverage is recommended for the electrical contact pads. Reflow Assembly This device is classified as MSL 3 with 260 C peak reflow temperature. A baking process (125 C, 24 hrs) is required if device is not kept continuously in a dry (< 10% RH) environment before assembly. No special reflow profile is required for HMC5883L, which is compatible with lead eutectic and lead-free solder paste reflow profiles. Honeywell recommends adherence to solder paste manufacturer’s guidelines. INTERNAL SCHEMATIC DIAGRAM HMC5883L www.honeywell.com 5 HMC5883L DUAL SUPPLY REFERENCE DESIGN SINGLE SUPPLY REFERENCE DESIGN 6 www.honeywell.com HMC5883L PERFORMANCE The following graph(s) highlight HMC5883L’s performance. Typical Resolution Typical Measurement Period in Single-Measurement Mode * Monitoring of the DRDY Interrupt pin is only required if maximum output rate is desired. www.honeywell.com 7 HMC5883L BASIC DEVICE OPERATION Anisotropic Magneto-Resistive Sensors The Honeywell HMC5883L magnetoresistive sensor circuit is a trio of sensors and application specific support circuits to measure magnetic fields. With power supply applied, the sensor converts any incident magnetic field in the sensitive axis directions to a differential voltage output. The magnetoresistive sensors are made of a nickel-iron (Permalloy) thin-film and patterned as a resistive strip element. In the presence of a magnetic field, a change in the bridge resistive elements causes a corresponding change in voltage across the bridge outputs. These resistive elements are aligned together to have a common sensitive axis (indicated by arrows in the pinout diagram) that will provide positive voltage change with magnetic fields increasing in the sensitive direction. Because the output is only proportional to the magnetic field component along its axis, additional sensor bridges are placed at orthogonal directions to permit accurate measurement of magnetic field in any orientation. Self Test To check the HMC5883L for proper operation, a self test feature in incorporated in which the sensor is internally excited with a nominal magnetic field (in either positive or negative bias configuration). This field is then measured and reported. This function is enabled and the polarity is set by bits MS[n] in the configuration register A. An internal current source generates DC current (about 10 mA) from the VDD supply. This DC current is applied to the offset straps of the magnetoresistive sensor, which creates an artificial magnetic field bias on the sensor. See SELF TEST OPERATION section later in this datasheet for additional details. Power Management This device has two different domains of power supply. The first one is VDD that is the power supply for internal operations and the second one is VDDIO that is dedicated to IO interface. It is possible to work with VDDIO equal to VDD; Single Supply mode, or with VDDIO lower than VDD allowing HMC5883L to be compatible with other devices on board. 2 I C Interface 2 Control of this device is carried out via the I C bus. This device will be connected to this bus as a slave device under the control of a master device, such as the processor. 2 2 This device is compliant with I C-Bus Specification, document number: 9398 393 40011. As an I C compatible device, 2 this device has a 7-bit serial address and supports I C protocols. This device supports standard and fast modes, 100kHz and 400kHz, respectively, but does not support the high speed mode (Hs). External pull-up resistors are required to support these standard and fast speed modes. Activities required by the master (register read and write) have priority over internal activities, such as the measurement. 2 The purpose of this priority is to not keep the master waiting and the I C bus engaged for longer than necessary. Internal Clock The device has an internal clock for internal digital logic functions and timing management. H-Bridge for Set/Reset Strap Drive The ASIC contains large switching FETs capable of delivering a large but brief pulse to the Set / Reset strap of the sensor. This strap is largely a resistive load. There is no need for an external Set/Reset circuit. The controlling of the Set/Reset function is done automatically by the ASIC for each measurement. One half of the difference from the measurements taken after a set pulse and after a reset pulse will be put in the data output register for each of the three axes. By doing so, the sensor’s internal offset and its temperature dependence is removed/cancelled for all measurements. Charge Current Limit The current that reservoir capacitor (C1) can draw when charging is limited for both single supply and dual supply 8 www.honeywell.com HMC5883L configurations. This prevents drawing down the supply voltage (VDD). MODES OF OPERATION This device has several operating modes whose primary purpose is power management and is controlled by the Mode Register. This section describes these modes. Continuous-Measurement Mode During continuous-measurement mode, the device continuously makes measurements, at user selectable rate, and places measured data in data output registers. Data can be re-read from the data output registers if necessary; however, if the master does not ensure that the data register is accessed before the completion of the next measurement, the data output registers are updated with the new measurement. To conserve current between measurements, the device is placed in a state similar to idle mode, but the Mode Register is not changed to Idle Mode. That is, MD[n] bits are unchanged. Settings in the Configuration Register A affect the data output rate (bits DO[n]), the measurement configuration (bits MS[n]), when in continuous-measurement mode. All registers maintain values while in continuous2 measurement mode. The I C bus is enabled for use by other devices on the network in while continuous-measurement mode. Single-Measurement Mode This is the default power-up mode. During single-measurement mode, the device makes a single measurement and places the measured data in data output registers. After the measurement is complete and output data registers are updated, the device is placed in idle mode, and the Mode Register is changed to idle mode by setting MD[n] bits. Settings in the configuration register affect the measurement configuration (bits MS[n])when in single-measurement mode. All 2 registers maintain values while in single-measurement mode. The I C bus is enabled for use by other devices on the network while in single-measurement mode. Idle Mode 2 During this mode the device is accessible through the I C bus, but major sources of power consumption are disabled, such as, but not limited to, the ADC, the amplifier, and the sensor bias current. All registers maintain values while in idle 2 mode. The I C bus is enabled for use by other devices on the network while in idle mode. www.honeywell.com 9 HMC5883L REGISTERS This device is controlled and configured via a number of on-chip registers, which are described in this section. In the following descriptions, set implies a logic 1, and reset or clear implies a logic 0, unless stated otherwise. Register List The table below lists the registers and their access. All address locations are 8 bits. Address Location 00 01 02 03 04 05 06 07 08 09 10 11 12 Name Configuration Register A Configuration Register B Mode Register Data Output X MSB Register Data Output X LSB Register Data Output Z MSB Register Data Output Z LSB Register Data Output Y MSB Register Data Output Y LSB Register Status Register Identification Register A Identification Register B Identification Register C Access Read/Write Read/Write Read/Write Read Read Read Read Read Read Read Read Read Read Table2: Register List Register Access This section describes the process of reading from and writing to this device. The devices uses an address pointer to indicate which register location is to be read from or written to. These pointer locations are sent from the master to this slave device and succeed the 7-bit address plus 1 bit read/write identifier. To minimize the communication between the master and this device, the address pointer updated automatically without master intervention. This automatic address pointer update has two additional features. First when address 12 or higher is accessed the pointer updates to address 00 and secondly when address 08 is reached, the pointer rolls back to address 03. Logically, the address pointer operation functions as shown below. If (address pointer = 08) then address pointer = 03 Else if (address pointer >= 12) then address pointer = 0 Else (address pointer) = (address pointer) + 1 2 The address pointer value itself cannot be read via the I C bus. Any attempt to read an invalid address location returns 0’s, and any write to an invalid address location or an undefined bit within a valid address location is ignored by this device. To move the address pointer to a random register location, first issue a “write” to that register location with no data byte following the commend. For example, to move the address pointer to register 10, send 0x3C 0x0A. 10 www.honeywell.com HMC5883L Configuration Register A The configuration register is used to configure the device for setting the data output rate and measurement configuration. CRA0 through CRA7 indicate bit locations, with CRA denoting the bits that are in the configuration register. CRA7 denotes the first bit of the data stream. The number in parenthesis indicates the default value of that bit. CRA7 CRA6 CRA5 CRA4 CRA3 CRA2 CRA1 CRA0 (1) MA1(1) MA0(1) DO2 (1) DO1 (0) DO0 (0) MS1 (0) MS0 (0) Table 3: Configuration Register A Location Name Description CRA7 CRA7 CRA6 to CRA5 MA1 to MA0 CRA4 to CRA2 DO2 to DO0 This bit must be cleared for correct operation. Select number of samples averaged (1 to 8) per measurement output. 00 = 1; 01 = 2; 10 = 4; 11 = 8 (Default) Data Output Rate Bits. These bits set the rate at which data is written to all three data output registers. CRA1 to CRA0 MS1 to MS0 Measurement Configuration Bits. These bits define the measurement flow of the device, specifically whether or not to incorporate an applied bias into the measurement. Table 4: Configuration Register A Bit Designations The Table below shows all selectable output rates in continuous measurement mode. All three channels shall be measured within a given output rate. Other output rates with maximum rate of 160 Hz can be achieved by monitoring DRDY interrupt pin in single measurement mode. DO2 DO1 DO0 Typical Data Output Rate (Hz) 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0.75 1.5 3 7.5 15 (Default) 30 75 Not used Table 5: Data Output Rates MS1 MS0 Measurement Mode 0 0 Normal measurement configuration (Default). In normal measurement configuration the device follows normal measurement flow. The positive and negative pins of the resistive load are left floating and high impedance. 0 1 Positive bias configuration for X, Y, and Z axes. In this configuration, a positive current is forced across the resistive load for all three axes. 1 0 Negative bias configuration for X, Y and Z axes. In this configuration, a negative current is forced across the resistive load for all three axes.. 1 1 This configuration is reserved. Table 6: Measurement Modes www.honeywell.com 11 HMC5883L Configuration Register B The configuration register B for setting the device gain. CRB0 through CRB7 indicate bit locations, with CRB denoting the bits that are in the configuration register. CRB7 denotes the first bit of the data stream. The number in parenthesis indicates the default value of that bit. CRB7 CRB6 CRB5 CRB4 CRB3 CRB2 CRB1 CRB0 GN2 (0) GN1 (0) GN0 (1) (0) (0) (0) (0) (0) Table 7: Configuration B Register Location Name Description CRB7 to CRB5 GN2 to GN0 Gain Configuration Bits. These bits configure the gain for the device. The gain configuration is common for all channels. CRB4 to CRB0 0 These bits must be cleared for correct operation. Table 8: Configuration Register B Bit Designations The table below shows nominal gain settings. Use the “Gain” column to convert counts to Gauss. Choose a lower gain value (higher GN#) when total field strength causes overflow in one of the data output registers (saturation). GN1 GN0 Recommended Sensor Field Range Gain (LSB/ Gauss) 0 0 0 ± 0.88 Ga 1370 0xF800–0x07FF (-2048–2047 ) 0 0 1 ± 1.3 Ga 1090 (default) 0xF800–0x07FF (-2048–2047 ) 0 1 0 ± 1.9 Ga 820 0xF800–0x07FF (-2048–2047 ) 0 1 1 ± 2.5 Ga 660 0xF800–0x07FF (-2048–2047 ) 1 0 0 ± 4.0 Ga 440 0xF800–0x07FF (-2048–2047 ) 1 0 1 ± 4.7 Ga 390 0xF800–0x07FF (-2048–2047 ) 1 1 0 ± 5.6 Ga 330 0xF800–0x07FF (-2048–2047 ) 1 1 1 ± 8.1 Ga 230 0xF800–0x07FF (-2048–2047 ) GN2 Output Range Table 9: Gain Settings 12 www.honeywell.com HMC5883L Mode Register The mode register is an 8-bit register from which data can be read or to which data can be written. This register is used to select the operating mode of the device. MR0 through MR7 indicate bit locations, with MR denoting the bits that are in the mode register. MR7 denotes the first bit of the data stream. The number in parenthesis indicates the default value of that bit. MR7 MR6 MR5 MR4 MR3 MR2 MR1 MR0 (1) (0) (0) (0) (0) (0) MD1 (0) MD0 (1) Table 10: Mode Register Location Name MR7 to MR2 0 MR1 to MR0 MD1 to MD0 Description These bits must be cleared for correct operation. Bit MR7 bit is set internally after each single-measurement operation. Mode Select Bits. These bits select the operation mode of this device. Table 11: Mode Register Bit Designations MD1 MD0 Operating Mode Continuous-Measurement Mode. In continuous-measurement mode, the device continuously performs measurements and places the result in the data register. RDY goes high when new data is placed in all three registers. After a power-on or a write to the mode or configuration register, the first measurement set is available from all three data output registers after a period of 2/fDO and subsequent measurements are available at a frequency of fDO, where fDO is the frequency of data output. Single-Measurement Mode (Default). When single-measurement mode is selected, device performs a single measurement, sets RDY high and returned to idle mode. Mode register returns to idle mode bit values. The measurement remains in the data output register and RDY remains high until the data output register is read or another measurement is performed. 0 0 0 1 1 0 Idle Mode. Device is placed in idle mode. 1 1 Idle Mode. Device is placed in idle mode. Table 12: Operating Modes www.honeywell.com 13 HMC5883L Data Output X Registers A and B The data output X registers are two 8-bit registers, data output register A and data output register B. These registers store the measurement result from channel X. Data output X register A contains the MSB from the measurement result, and data output X register B contains the LSB from the measurement result. The value stored in these two registers is a 16-bit value in 2’s complement form, whose range is 0xF800 to 0x07FF. DXRA0 through DXRA7 and DXRB0 through DXRB7 indicate bit locations, with DXRA and DXRB denoting the bits that are in the data output X registers. DXRA7 and DXRB7 denote the first bit of the data stream. The number in parenthesis indicates the default value of that bit. In the event the ADC reading overflows or underflows for the given channel, or if there is a math overflow during the bias measurement, this data register will contain the value -4096. This register value will clear when after the next valid measurement is made. DXRA7 DXRA6 DXRA5 DXRA4 DXRA3 DXRA2 DXRA1 DXRA0 (0) (0) (0) (0) (0) (0) (0) (0) DXRB7 DXRB6 DXRB5 DXRB4 DXRB3 DXRB2 DXRB1 DXRB0 (0) (0) (0) (0) (0) (0) (0) (0) Table 13: Data Output X Registers A and B Data Output Y Registers A and B The data output Y registers are two 8-bit registers, data output register A and data output register B. These registers store the measurement result from channel Y. Data output Y register A contains the MSB from the measurement result, and data output Y register B contains the LSB from the measurement result. The value stored in these two registers is a 16-bit value in 2’s complement form, whose range is 0xF800 to 0x07FF. DYRA0 through DYRA7 and DYRB0 through DYRB7 indicate bit locations, with DYRA and DYRB denoting the bits that are in the data output Y registers. DYRA7 and DYRB7 denote the first bit of the data stream. The number in parenthesis indicates the default value of that bit. In the event the ADC reading overflows or underflows for the given channel, or if there is a math overflow during the bias measurement, this data register will contain the value -4096. This register value will clear when after the next valid measurement is made. DYRA7 DYRA6 DYRA5 DYRA4 DYRA3 DYRA2 DYRA1 DYRA0 (0) (0) (0) (0) (0) (0) (0) (0) DYRB7 DYRB6 DYRB5 DYRB4 DYRB3 DYRB2 DYRB1 DYRB0 (0) (0) (0) (0) (0) (0) (0) (0) Table 14: Data Output Y Registers A and B Data Output Z Registers A and B The data output Z registers are two 8-bit registers, data output register A and data output register B. These registers store the measurement result from channel Z. Data output Z register A contains the MSB from the measurement result, and data output Z register B contains the LSB from the measurement result. The value stored in these two registers is a 16-bit value in 2’s complement form, whose range is 0xF800 to 0x07FF. DZRA0 through DZRA7 and DZRB0 through DZRB7 indicate bit locations, with DZRA and DZRB denoting the bits that are in the data output Z registers. DZRA7 and DZRB7 denote the first bit of the data stream. The number in parenthesis indicates the default value of that bit. In the event the ADC reading overflows or underflows for the given channel, or if there is a math overflow during the bias measurement, this data register will contain the value -4096. This register value will clear when after the next valid measurement is made. 14 www.honeywell.com HMC5883L DZRA7 DZRA6 DZRA5 DZRA4 DZRA3 DZRA2 DZRA1 DZRA0 (0) (0) (0) (0) (0) (0) (0) (0) DZRB7 DZRB6 DZRB5 DZRB4 DZRB3 DZRB2 DZRB1 DZRB0 (0) (0) (0) (0) (0) (0) (0) (0) Table 15: Data Output Z Registers A and B Data Output Register Operation When one or more of the output registers are read, new data cannot be placed in any of the output data registers until all six data output registers are read. This requirement also impacts DRDY and RDY, which cannot be cleared until new data is placed in all the output registers. Status Register The status register is an 8-bit read-only register. This register is used to indicate device status. SR0 through SR7 indicate bit locations, with SR denoting the bits that are in the status register. SR7 denotes the first bit of the data stream. SR7 SR6 SR5 SR4 SR3 SR2 SR1 SR0 (0) (0) (0) (x) (0) (0) LOCK (0) RDY(0) Table 16: Status Register Location Name SR7 to SR2 0 SR1 LOCK SR0 RDY Description These bits are reserved. SR4 may be 0 or 1 depending on internal activity. Disregard activity on this bit. Data output register lock. This bit is set when this some but not all for of the six data output registers have been read. When this bit is set, the six data output registers are locked and any new data will not be placed in these register until one of three conditions are met: one, all six bytes have been read or the mode changed, two, the mode is changed, or three, the measurement configuration is changed. Ready Bit. Set when data is written to all six data registers. Cleared when device initiates a write to the data output registers and after one or more of the data output registers are written to. When RDY bit is clear it shall remain cleared for a 250 μs. DRDY pin can be used as an alternative to the status register for monitoring the device for measurement data. Table 17: Status Register Bit Designations www.honeywell.com 15 HMC5883L Identification Register A The identification register A is used to identify the device. IRA0 through IRA7 indicate bit locations, with IRA denoting the bits that are in the identification register A. IRA7 denotes the first bit of the data stream. The number in parenthesis indicates the default value of that bit. The identification value for this device is stored in this register. This is a read-only register. Register values. ASCII value H IRA7 IRA6 IRA5 IRA4 IRA3 IRA2 IRA1 IRA0 0 1 0 0 1 0 0 0 Table 18: Identification Register A Default Values Identification Register B The identification register B is used to identify the device. IRB0 through IRB7 indicate bit locations, with IRB denoting the bits that are in the identification register A. IRB7 denotes the first bit of the data stream. Register values. ASCII value 4 IRB7 IRB6 IRB5 IRB4 IRB3 IRB2 IRB1 IRB0 0 0 1 1 0 1 0 0 Table 19: Identification Register B Default Values Identification Register C The identification register C is used to identify the device. IRC0 through IRC7 indicate bit locations, with IRC denoting the bits that are in the identification register A. IRC7 denotes the first bit of the data stream. Register values. ASCII value 3 IRC7 IRC6 IRC5 IRC4 IRC3 IRC2 IRC1 IRC0 0 0 1 1 0 0 1 1 Table 20: Identification Register C Default Values I2C COMMUNICATION PROTOCOL 2 The HMC5883L communicates via a two-wire I C bus system as a slave device. The HMC5883L uses a simple protocol 2 with the interface protocol defined by the I C bus specification, and by this document. The data rate is at the standard2 mode 100kbps or 400kbps rates as defined in the I C Bus Specifications. The bus bit format is an 8-bit Data/Address send and a 1-bit acknowledge bit. The format of the data bytes (payload) shall be case sensitive ASCII characters or binary data to the HMC5883L slave, and binary data returned. Negative binary values will be in two’s complement form. The default (factory) HMC5883L 8-bit slave address is 0x3C for write operations, or 0x3D for read operations. The HMC5883L Serial Clock (SCL) and Serial Data (SDA) lines require resistive pull-ups (Rp) between the master device (usually a host microprocessor) and the HMC5883L. Pull-up resistance values of about 2.2K to 10K ohms are 2 recommended with a nominal VDDIO voltage. Other resistor values may be used as defined in the I C Bus Specifications that can be tied to VDDIO. The SCL and SDA lines in this bus specification may be connected to multiple devices. The bus can be a single master to multiple slaves, or it can be a multiple master configuration. All data transfers are initiated by the master device, which is 2 responsible for generating the clock signal, and the data transfers are 8 bit long. All devices are addressed by I C’s 16 www.honeywell.com HMC5883L th unique 7-bit address. After each 8-bit transfer, the master device generates a 9 clock pulse, and releases the SDA line. The receiving device (addressed slave) will pull the SDA line low to acknowledge (ACK) the successful transfer or leave the SDA high to negative acknowledge (NACK). 2 Per the I C spec, all transitions in the SDA line must occur when SCL is low. This requirement leads to two unique conditions on the bus associated with the SDA transitions when SCL is high. Master device pulling the SDA line low while the SCL line is high indicates the Start (S) condition, and the Stop (P) condition is when the SDA line is pulled high while 2 the SCL line is high. The I C protocol also allows for the Restart condition in which the master device issues a second start condition without issuing a stop. All bus transactions begin with the master device issuing the start sequence followed by the slave address byte. The address byte contains the slave address; the upper 7 bits (bits7-1), and the Least Significant bit (LSb). The LSb of the th address byte designates if the operation is a read (LSb=1) or a write (LSb=0). At the 9 clock pulse, the receiving slave device will issue the ACK (or NACK). Following these bus events, the master will send data bytes for a write operation, or the slave will clock out data with a read operation. All bus transactions are terminated with the master issuing a stop sequence. 2 I C bus control can be implemented with either hardware logic or in software. Typical hardware designs will release the SDA and SCL lines as appropriate to allow the slave device to manipulate these lines. In a software implementation, care must be taken to perform these tasks in code. OPERATIONAL EXAMPLES The HMC5883L has a fairly quick stabilization time from no voltage to stable and ready for data retrieval. The nominal 6 milli-seconds with the factory default single measurement mode means that the six bytes of magnetic data registers (DXRA, DXRB, DZRA, DZRB, DYRA, and DYRB) are filled with a valid first measurement. To change the measurement mode to continuous measurement mode, after the power-up time send the three bytes: 0x3C 0x02 0x00 This writes the 00 into the second register or mode register to switch from single to continuous measurement mode setting. With the data rate at the factory default of 15Hz updates, a 67 milli-second typical delay should be allowed by the 2 I C master before querying the HMC5883L data registers for new measurements. To clock out the new data, send: 0x3D, and clock out DXRA, DXRB, DZRA, DZRB, DYRA, and DYRB located in registers 3 through 8. The HMC5883L will automatically re-point back to register 3 for the next 0x3D query. All six data registers must be read properly before new data can be placed in any of these data registers. SELF TEST OPERATION To check the HMC5883L for proper operation, a self test feature in incorporated in which the sensor offset straps are excited to create a nominal field strength (bias field) to be measured. To implement self test, the least significant bits (MS1 and MS0) of configuration register A are changed from 00 to 01 (positive bias) or 10 (negetive bias), e.g. 0x11 or 0x12. Then, by placing the mode register into single-measurement mode (0x01), two data acquisition cycles will be made on each magnetic vector. The first acquisition will be a set pulse followed shortly by measurement data of the external field. The second acquisition will have the offset strap excited (about 10 mA) in the positive bias mode for X, Y, and Z axes to create about a ±1.1 gauss self test field plus the external field. The first acquisition values will be subtracted from the second acquisition, and the net measurement will be placed into the data output registers. Since self test adds ~1.1 Gauss additional field to the existing field strength, using a reduced gain setting prevents sensor from being saturated and data registers overflowed. For example, if the configuration register B is set to 0x60 (Gain=3), values around +766 LSB (1.16 Ga * 660 LSB/Ga) will be placed in the X and Y data output registers and around +713 (1.08 Ga * 660 LSB/Ga) will be placed in Z data output register. To leave the self test mode, change MS1 and MS0 bit of the configuration register A back to 00 (Normal Measurement Mode), e.g. 0x10. www.honeywell.com 17 HMC5883L SCALE FACTOR CALIBRATION Using the self test method described above, the user can scale sensors’ sensitivity to match each other. Since placing device in positive bias mode (or alternatively negative bias mode) applies a known artificial field on all three axes, the resulting ADC measurements in data output registers can be used to scale the sensors. For example, if the expected self test value for X-axis is 766 and the actual value is 750 then a scale factor of (766/750) should be multiplied to all future readings of X-axis. Doing so for all three axes will ensure their sensitivity are well matched, The built-in self test can also be used to periodically compensate the scaling errors due to temperature variations. A compensation factor can be found by comparing the self test outputs with the ones obtained at a known temperature. For example, if the self test output is 750 at room temperature and 700 at the current temperature then a compensation factor of (750/700) should be applied to all current magnetic readings. A temperature sensor is not required using this method. EXTERNAL CAPACITORS The two external capacitors should be ceramic type construction with low ESR characteristics. The exact ESR values are not critical but values less than 200 milli-ohms are recommended. Reservoir capacitor C1 is nominally 4.7 µF in capacitance, with the set/reset capacitor C2 nominally 0.22 µF in capacitance. Low ESR characteristics may not be in many small SMT ceramic capacitors (0402), so be prepared to up-size the capacitors to gain Low ESR characteristics. ORDERING INFORMATION Ordering Number HMC5883L-TR Product Tape and Reel 4k pieces/reel FIND OUT MORE For more information on Honeywell’s Magnetic Sensors visit us online at www.honeywell.com/magneticsensors or contact us at 800-323-8295 (763-954-2474 internationally). The application circuits herein constitute typical usage and interface of Honeywell product. Honeywell does not warranty or assume liability of customerdesigned circuits derived from this description or depiction. Honeywell reserves the right to make changes to improve reliability, function or design. Honeywell does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others. U.S. Patents 4,441,072, 4,533,872, 4,569,742, 4,681,812, 4,847,584 and 6,529,114 apply to the technology described Honeywell 12001 Highway 55 Plymouth, MN 55441 Tel: 800-323-8295 www.honeywell.com/magneticsensors 18 Form # 900405 Rev B October 2010 ©2010 Honeywell International Inc. www.honeywell.com