MURATA-PS HPR717

OBSOLETE PRODUCT
Contact factory for replacement model
5 WATT UNREGULATED
SIP DC/DC CONVERTER
HPR7XX
FEATURES
L EFFICIENCY >80%
L SIP PACKAGE
L HIGH POWER DENSITY: > 16 WATTS/INCH3
L LOW COST
L SINGLE AND DUAL OUTPUTS
L INTERNAL INPUT AND OUTPUT FILTERING
L SIX-SIDED SHIELDING
DESCRIPTION
The HPR7XX Series provides high power densities where space
is critical. The small SIP package measures only 2.2" x .3" x .4"
(56 x 9 x 10 mm). Designed for high density boards, the package is non-conductive, which presents advantages over painted
metal enclosures.
Operation down to no load will not impact the reliability of the
series, although this product has a 10mA minimum load for
specification purposes. It is recommended that all pins be used
for current carrying capacity even though duplicate pin-outs are
internally connected.
The series includes many different voltage models (other input
and output voltages are available upon request), all set in a low
thermal resistance molding compound, called Iso-ThermoFlex“,
which provides excellent heat dissipation of internal components.
The use of surface mount devices and manufacturing processes,
combined with the encapsulation process, assure the user that
the product is more environmentally rugged than any other DC/
DC converter of its type.
The HPR7XX has 500VDC isolation barrier between input and
output, offering the designer maximum flexibility in grounding
options and polarity configurations. The outstanding MTTF,
superior reliability, and low cost make it an excellent choice for
any high power- density applications.
MECHANICAL
2.210 + 0-.10
(56.13)
PIN CONNECTIONS: Duals
TOP
VIEW
0.340 + .010
(8.64)
FRONT
VIEW
0.400 + .010
(10.16)
0.030 + -.010
(0.76)
0.155 + -.15
(3.94)
0.020 + .002
(0.51)
7. -VIN
15. COM
2. +VIN
9. -VIN
19. COM
6. -VIN
14. +VOUT
20. -VOUT
PIN CONNECTIONS: Singles
1. +VIN
7. -VIN
15. +VOUT
2. +VIN
9. -VIN
19. -VOUT
6. -VIN
14. +VOUT
20. -VOUT
0.140 + .020
(3.56)
0.010 + .002
0.140 + .020
(3.56)
CL
1. +VIN
(0.25)
0.050 + .015
(1.27)
RIGHT SIDE
VIEW
BOTTOM
VIEW
1 2
HPR7XX
REV C
12/08
6 7
9
14 15
19 20
All dimensions are in inches (millimeters)
GRID: 0.100 inches (2.54 millimeters)
PIN PLACEMENT TOLERANCE: ±0.015"
Page 1
ELECTRICAL CHARACTERISTICS
MODEL
NOMINAL
INPUT
VOLTAGE
(VDC)
RATED
OUTPUT
VOLTAGE
(VDC)
RATED
OUTPUT
CURRENT
(mA)
INPUT CURRENT
NO LOAD
RATED LOAD
(mA)
(mA)
REFLECTED
RIPPLE
CURRENT
(mAp-p)
EFFICIENCY
(%)
HPR700
HPR703
HPR704
HPR705
5
5
5
5
5
±5
±12
±15
1000
±500
±208
±167
70
70
70
70
1250
1250
1190
1190
15
15
15
15
80
80
84
84
HPR706
HPR710
HPR711
12
12
12
5
±12
±15
1000
±208
±167
25
25
25
490
490
490
15
15
15
80
85
85
HPR712
HPR717
15
15
5
±15
1000
±167
20
20
407
392
15
15
82
85
MAX
UNITS
Note: Other input to output voltage options may be available. Please consult factory.
COMMON SPECIFICATIONS
PARAMETER
CONDITIONS
INPUT
Voltage Range
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
60 Hz, 10 seconds
500
500
5
±3
±0.05
50
5
Rated Load, Nominal VIN
BW = DC to 10MHz
BW =10Hz to 2MHz
IL=10mA, VOUT = 5V
IL=10mA, VOUT = ±12V
IL=10mA, VOUT = ±15V
GENERAL
Switching Frequency
Package Weight
MTTF per MIL-HDBK-217, Rev. E
Ground Benign
1.2
15
10
Circuit Stress Method
TA = +25°C
TEMPERATURE
Specification
Operation
Storage
ABSOLUTE MAXIMUM RATINGS
Internal Power Dissipation.......................................................................1.7W
Short Circuit Protection..................................................................Momentary
Lead Temperature (soldering, 10 seconds max)................................+300°C
W
%
%/Deg C
mVp-p
mVrms
VDC
VDC
VDC
5.75
13.10
16.25
High Line to Low Line
Rated Load to No Load
Rated Load to No Load
-25
-40
-40
VDC
VDC
VDC
VDC
Vpk
GW
pF
μArms
1
55
5
VISO= 240VAC, 60Hz
Voltage
REGULATION
Line Regulation
Load Regulation (5V out only)
Load Regulation (All other Models)
TYP
4.75
5
5.25
11.4
12
12.6
14.2
15
15.8
See Application Note: "Capacitive Loading Effects on Start-Up of DC/DC Converters"
Voltage Rise Time
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Temperature Coefficent
Ripple & Noise
MIN
%/%Vin
%
%
170
7
kHz
g
2000
kHr
+25
+70
+85
+110
°C
°C
°C
ORDERING INFORMATION
HPR
7XX
/H
Device Family
HPR indicates DC/DC converter
Model Number
Screening Option
Page 2
HPR7XX
REV C
12/08
TYPICAL PERFORMANCE CURVES
VOUT VS LOAD
5.6
5.6
(5VOUT Models)
5.4
5.2
5.2
Vout
Vout
5.4
VOUT VS LOAD
(+5VOUT Models)
5.0
5.0
4.8
10
250
500
750
4.8
10
1000
500
750
1000
Output Current (mA)
Output Current (mA)
VOUT VS LOAD
12.6
250
15.6
(+12VOUT Models)
15.4
12.2
15.2
(+15VOUT Models)
Vout
Vout
12.4
VOUT VS LOAD
15.0
12.0
11.8
10
250
500
750
1000
14.8
10
Output Current (mA)
250
500
750
1000
Output Current (mA)
The information provided herein is believed to be reliable; however, MuraTA POWER SOLUTIONS assumes no responsibility for inaccuracies or omissions. MuraTA POWER SOLUTIONS assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights
or licenses to any of the circuits described herein are implied or granted to any third party. MuraTA POWER SOLUTIONS does not authorize or warrant any MuraTA POWER SOLUTIONS product for
use in life support devices/systems or in aircraft control applications.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
USA:
Mansfield (MA), Tel: (508) 339 3000, email: [email protected]
Canada:
Toronto, Tel: (866) 740 1232, email: [email protected]
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany: München, Tel: +49 (0)89-544334-0, email: [email protected]
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
www.murata-ps.com email: [email protected] ISO 9001 & ISO 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
HPR7XX
REV C
12/08
Singapore: Parkway Centre, Tel: +65 6348 9096, email: [email protected]
Page 3