SEME-LAB IP117MAHVE_07

IP117MAHVE
IP117MHVE
9.14 (0.360)
8.64 (0.340)
1.27 (0.050)
1.07 (0.040)
≈ 2.16 (0.085)
12 13 14 15 16
1.39 (0.055)
1.02 (0.040)
7.62 (0.300)
7.12 (0.280)
11
17
10
18
9
1
8
2
7
6
5
1.39 (0.055)
1.15 (0.045)
4
3
1.65 (0.065)
1.40 (0.055)
IP117MAE
IP117MEA
0.5 AMP
POSITIVE ADJUSTABLE
VOLTAGE REGULATOR
IN CERAMIC SURFACE
MOUNT PACKAGE
FEATURES
0.76 (0.030)
0.51 (0.020)
0.33 (0.013)
Rad.
0.08 (0.003)
0.43 (0.017)
0.18 (0.007 Rad.
• OUTPUT VOLTAGE RANGE ADJUSTABLE:
1.25 TO 40V FOR STANDARD VERSION
1.25 TO 60V FOR –HV VERSION
• 1% OUTPUT VOLTAGE TOLERANCE
(–A VERSIONS)
• 0.3% LOAD REGULATION
• 0.01% / V LINE REGULATION
Pins 4,5
– Adjust
Pins 6,7,8,9,10,11,12,13 – VIN
Pins 15,16,17,18,1,2
– VOUT
• COMPLETE SERIES OF PROTECTIONS:
• CURRENT LIMITING
• THERMAL SHUTDOWN
• SOA CONTROL
DESCRIPTION
The IP117M Series are three terminal positive adjustable voltage regulators capable of supplying in excess of 0.5A over a
1.25V to 60V output range. These regulators are exceptionally easy to use and require only two external resistors to set the
output voltage. In addition to improved line and load regulation, a major feature of the “A” series is the initial output voltage
tolerance, which is guaranteed to be less than 1%.
Over full operating conditions, including load, line, and power dissipation, the reference voltage is guaranteed not to vary more
than 2%. These devices exhibit current limit, thermal overload protection, and improved power device safe operating area
protection, making them essentially indestructible.
ABSOLUTE MAXIMUM RATINGS (Tcase = 25°C unless otherwise stated)
VI–O
Input - Output Differential Voltage
– Standard
40V
– HV Series
60V
PD
Power Dissipation
TJ
Operating Junction Temperature Range
–55 to 150°C
TSTG
Storage Temperature
–65 to 150°C
Internally limited
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: [email protected]
Website: http://www.semelab.co.uk
Document Number 5383
Issue 1
IP117MAHVE
IP117MHVE
Parameter
VREF
Reference Voltage
Test Conditions
IP117MAHV
IP117MA
Min.
Typ.
Max.
IOUT = 10mA
1.238
1.25
1.262
1.220
1.250
1.270
0.005
ΔVIN
ΔIOUT
Load Regulation 1
Thermal Regulation
Ripple Rejection
IADJ
Adjust Pin Current
ΔIADJ
Adjust Pin Current
Change
0.010
0.020
0.020
0.050
VOUT ≤ 5V
5
15
5
15
mV
VOUT ≥ 5V
0.1
0.3
0.1
0.3
%
IOUT = 10mA to IMAX
VOUT ≤ 5V
15
50
20
50
mV
TJ = –55 to +150°C
VOUT ≥ 5V
TJ = –55 to +150°C
tp = 20ms
CADJ = 0
VOUT = 10V
CADJ = 10μF
f = 120Hz
TJ = –55 to +150°C
TJ = –55 to +150°C
1
0.3
1
%
0.020
0.030
0.070
%/W
80
66
65
dB
80
dB
50
100
50
100
μA
0.2
5
0.2
5
μA
3.5
5
3.5
5
IOUT = 10mA to IMAX
TJ = –55 to +150°C
Minimum Load
TJ = –55 to +150°C
Current
VIN – VOUT = 60V (HV SERIES)
Current Limit
ΔTEMP Stability
Long Term Stability
RMS Output Noise
(% of VOUT)
RθJC
0.3
0.002
65
66
%/V
VIN – VOUT = 2.5V to VMAX
ΔVOUT Temperature
en
1.200
V
0.020
TJ = –55 to +150°C
VIN – VOUT = 40V
VIN – VOUT = 60V (HV SERIES)
ΔTIME
V
0.010
VIN – VOUT ≤ 15V
ΔVOUT
Units
0.010
VIN – VOUT = 3V to VMAX
mA
3.5
TJ = –55 to +150°C
ICL
Max.
TJ = –55 to +150°C
VIN – VOUT = 40V
IMIN
Typ.
1.300
IOUT = 10mA to IMAX
ΔVOUT
Min.
1.250
P ≤ PMAX
Line Regulation 1
IP117MHV , IP117M
IOUT = 10mA to IMAX
VIN – VOUT = 3V to VMAX
ΔVOUT
IP117MAE
IP117MEA
Thermal Resistance
Junction to Case
TJ = –55 to +150°C
TA = +125°C
t = 1000 Hrs
f = 10 Hz to 10 kHz
7
3.5
0.50
0.80
0.50
0.80
0.15
0.20
0.15
0.20
0.30
A
A
0.30
1
2
1
0.3
1
0.3
0.001
LCC4 Package
7
%
1
%
0.001
13
%
13
°C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications.
2) Test Conditions unless othewise stated:
VIN – VOUT = 5V , TJ = 25°C , IOUT = 0.1A , PMAX = 10W , IMAX = 0.5A
VMAX = 40V for standard series , 60V for HV series.
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: [email protected]
Website: http://www.semelab.co.uk
Document Number 5383
Issue 1