IP117MAHV-LCC4 IP117MHV-LCC4 9.14 (0.360) 8.64 (0.340) 1.27 (0.050) 1.07 (0.040) ≈ 2.16 (0.085) 12 13 14 15 16 1.39 (0.055) 1.02 (0.040) 7.62 (0.300) 7.12 (0.280) 11 17 10 18 9 1 8 2 7 6 5 1.39 (0.055) 1.15 (0.045) 4 3 1.65 (0.065) 1.40 (0.055) IP117MA-LCC4 IP117M-LCC4A 0.5 AMP POSITIVE ADJUSTABLE VOLTAGE REGULATOR IN CERAMIC SURFACE MOUNT PACKAGE FEATURES 0.76 (0.030) 0.51 (0.020) 0.33 (0.013) Rad. 0.08 (0.003) 0.43 (0.017) 0.18 (0.007 Rad. • OUTPUT VOLTAGE RANGE ADJUSTABLE: 1.25 TO 40V FOR STANDARD VERSION 1.25 TO 60V FOR –HV VERSION • 1% OUTPUT VOLTAGE TOLERANCE (–A VERSIONS) • 0.3% LOAD REGULATION • 0.01% / V LINE REGULATION Pins 4,5 – Adjust Pins 6,7,8,9,10,11,12,13 – VIN Pins 15,16,17,18,1,2 – VOUT • COMPLETE SERIES OF PROTECTIONS: • CURRENT LIMITING • THERMAL SHUTDOWN • SOA CONTROL DESCRIPTION The IP117M Series are three terminal positive adjustable voltage regulators capable of supplying in excess of 0.5A over a 1.25V to 60V output range. These regulators are exceptionally easy to use and require only two external resistors to set the output voltage. In addition to improved line and load regulation, a major feature of the “A” series is the initial output voltage tolerance, which is guaranteed to be less than 1%. Over full operating conditions, including load, line, and power dissipation, the reference voltage is guaranteed not to vary more than 2%. These devices exhibit current limit, thermal overload protection, and improved power device safe operating area protection, making them essentially indestructible. ABSOLUTE MAXIMUM RATINGS (Tcase = 25°C unless otherwise stated) VI–O Input - Output Differential Voltage – Standard 40V – HV Series 60V PD Power Dissipation TJ Operating Junction Temperature Range –55 to 150°C TSTG Storage Temperature –65 to 150°C Semelab plc. Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612. Internally limited Prelim. 1/99 IP117MAHV-LCC4 IP117MHV-LCC4 Parameter VREF Reference Voltage Test Conditions IP117MAHV IP117MA Min. Typ. Max. IOUT = 10mA 1.238 1.25 1.262 1.220 1.250 1.270 0.005 0.010 VOUT ≤ 5V VOUT ≥ 5V P ≤ PMAX ∆VIN Line Regulation 1 ∆IOUT Load Regulation 1 Thermal Regulation Ripple Rejection IADJ Adjust Pin Current ∆IADJ Adjust Pin Current Change VIN – VOUT = 3V to VMAX TJ = –55 to +150°C V 1.250 1.300 0.010 0.010 0.020 0.020 0.020 0.050 5 15 5 15 mV 0.1 0.3 0.1 0.3 % %/V 15 50 20 50 mV 0.3 1 0.3 1 % 0.002 0.020 0.030 0.070 %/W tp = 20ms CADJ = 0 VOUT = 10V CADJ = 10µF f = 120Hz TJ = –55 to +150°C 65 66 TJ = –55 to +150°C 80 66 65 dB 80 dB 50 100 50 100 µA 0.2 5 0.2 5 µA 3.5 5 3.5 5 3.5 7 3.5 7 IOUT = 10mA to IMAX TJ = –55 to +150°C Minimum Load TJ = –55 to +150°C Current VIN – VOUT = 60V (HV SERIES) Current Limit ∆TEMP Stability Long Term Stability RMS Output Noise (% of VOUT) RθJC 1.200 VIN – VOUT = 2.5V to VMAX ∆VOUT Temperature en V VOUT ≥ 5V mA 0.50 TJ = –55 to +150°C VIN – VOUT = 40V 0.15 VIN – VOUT = 60V (HV SERIES) ∆TIME Units VOUT ≤ 5V VIN – VOUT ≤ 15V ∆VOUT Max. TJ = –55 to +150°C TJ = –55 to +150°C ICL Typ. IOUT = 10mA to IMAX VIN – VOUT = 40V IMIN Min. TJ = –55 to +150°C IOUT = 10mA to IMAX ∆VOUT IP117MHV , IP117M IOUT = 10mA to IMAX VIN – VOUT = 3V to VMAX ∆VOUT IP117MA-LCC4 IP117M-LCC4A Thermal Resistance Junction to Case TJ = –55 to +150°C TA = +125°C t = 1000 Hrs f = 10 Hz to 10 kHz 0.80 0.50 0.20 0.15 0.30 0.20 A 0.30 1 2 1 0.3 1 0.3 0.001 LCC4 Package A 0.80 % 1 % 0.001 13 % 13 °C/W 1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating effects are covered under thermal regulation specifications. 2) Test Conditions unless othewise stated: VIN – VOUT = 5V , TJ = 25°C , IOUT = 0.1A , PMAX = 10W , IMAX = 0.5A VMAX = 40V for standard series , 60V for HV series. Semelab plc. Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612. Prelim. 1/99