ETC IP117MALCC4-883B

IP117MAHV-LCC4
IP117MHV-LCC4
9.14 (0.360)
8.64 (0.340)
1.27 (0.050)
1.07 (0.040)
≈ 2.16 (0.085)
12 13 14 15 16
1.39 (0.055)
1.02 (0.040)
7.62 (0.300)
7.12 (0.280)
11
17
10
18
9
1
8
2
7
6
5
1.39 (0.055)
1.15 (0.045)
4
3
1.65 (0.065)
1.40 (0.055)
IP117MA-LCC4
IP117M-LCC4A
0.5 AMP
POSITIVE ADJUSTABLE
VOLTAGE REGULATOR
IN CERAMIC SURFACE
MOUNT PACKAGE
FEATURES
0.76 (0.030)
0.51 (0.020)
0.33 (0.013)
Rad.
0.08 (0.003)
0.43 (0.017)
0.18 (0.007 Rad.
• OUTPUT VOLTAGE RANGE ADJUSTABLE:
1.25 TO 40V FOR STANDARD VERSION
1.25 TO 60V FOR –HV VERSION
• 1% OUTPUT VOLTAGE TOLERANCE
(–A VERSIONS)
• 0.3% LOAD REGULATION
• 0.01% / V LINE REGULATION
Pins 4,5
– Adjust
Pins 6,7,8,9,10,11,12,13 – VIN
Pins 15,16,17,18,1,2
– VOUT
• COMPLETE SERIES OF PROTECTIONS:
• CURRENT LIMITING
• THERMAL SHUTDOWN
• SOA CONTROL
DESCRIPTION
The IP117M Series are three terminal positive adjustable voltage regulators capable of supplying in excess of 0.5A over a
1.25V to 60V output range. These regulators are exceptionally easy to use and require only two external resistors to set the
output voltage. In addition to improved line and load regulation, a major feature of the “A” series is the initial output voltage
tolerance, which is guaranteed to be less than 1%.
Over full operating conditions, including load, line, and power dissipation, the reference voltage is guaranteed not to vary more
than 2%. These devices exhibit current limit, thermal overload protection, and improved power device safe operating area
protection, making them essentially indestructible.
ABSOLUTE MAXIMUM RATINGS (Tcase = 25°C unless otherwise stated)
VI–O
Input - Output Differential Voltage
– Standard
40V
– HV Series
60V
PD
Power Dissipation
TJ
Operating Junction Temperature Range
–55 to 150°C
TSTG
Storage Temperature
–65 to 150°C
Semelab plc.
Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612.
Internally limited
Prelim. 1/99
IP117MAHV-LCC4
IP117MHV-LCC4
Parameter
VREF
Reference Voltage
Test Conditions
IP117MAHV
IP117MA
Min.
Typ.
Max.
IOUT = 10mA
1.238
1.25
1.262
1.220
1.250
1.270
0.005
0.010
VOUT ≤ 5V
VOUT ≥ 5V
P ≤ PMAX
∆VIN
Line Regulation 1
∆IOUT
Load Regulation 1
Thermal Regulation
Ripple Rejection
IADJ
Adjust Pin Current
∆IADJ
Adjust Pin Current
Change
VIN – VOUT = 3V to VMAX
TJ = –55 to +150°C
V
1.250
1.300
0.010
0.010
0.020
0.020
0.020
0.050
5
15
5
15
mV
0.1
0.3
0.1
0.3
%
%/V
15
50
20
50
mV
0.3
1
0.3
1
%
0.002
0.020
0.030
0.070
%/W
tp = 20ms
CADJ = 0
VOUT = 10V
CADJ = 10µF
f = 120Hz
TJ = –55 to +150°C
65
66
TJ = –55 to +150°C
80
66
65
dB
80
dB
50
100
50
100
µA
0.2
5
0.2
5
µA
3.5
5
3.5
5
3.5
7
3.5
7
IOUT = 10mA to IMAX
TJ = –55 to +150°C
Minimum Load
TJ = –55 to +150°C
Current
VIN – VOUT = 60V (HV SERIES)
Current Limit
∆TEMP Stability
Long Term Stability
RMS Output Noise
(% of VOUT)
RθJC
1.200
VIN – VOUT = 2.5V to VMAX
∆VOUT Temperature
en
V
VOUT ≥ 5V
mA
0.50
TJ = –55 to +150°C
VIN – VOUT = 40V
0.15
VIN – VOUT = 60V (HV SERIES)
∆TIME
Units
VOUT ≤ 5V
VIN – VOUT ≤ 15V
∆VOUT
Max.
TJ = –55 to +150°C
TJ = –55 to +150°C
ICL
Typ.
IOUT = 10mA to IMAX
VIN – VOUT = 40V
IMIN
Min.
TJ = –55 to +150°C
IOUT = 10mA to IMAX
∆VOUT
IP117MHV , IP117M
IOUT = 10mA to IMAX
VIN – VOUT = 3V to VMAX
∆VOUT
IP117MA-LCC4
IP117M-LCC4A
Thermal Resistance
Junction to Case
TJ = –55 to +150°C
TA = +125°C
t = 1000 Hrs
f = 10 Hz to 10 kHz
0.80
0.50
0.20
0.15
0.30
0.20
A
0.30
1
2
1
0.3
1
0.3
0.001
LCC4 Package
A
0.80
%
1
%
0.001
13
%
13
°C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications.
2) Test Conditions unless othewise stated:
VIN – VOUT = 5V , TJ = 25°C , IOUT = 0.1A , PMAX = 10W , IMAX = 0.5A
VMAX = 40V for standard series , 60V for HV series.
Semelab plc.
Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612.
Prelim. 1/99