BB ISO254P

ISO254
®
ISO
254
Precision, Powered, Three-Port Isolated
PROGRAMMABLE GAIN AMPLIFIER
FEATURES
DESCRIPTION
● RATED
1500Vrms Continuous
2500Vrms for One Minute
100% TESTED FOR PARTIAL DISCHARGE
● LOW NONLINEARITY: ±0.01% typ
● LOW INPUT BIAS CURRENT: ±5nA max
● LOW INPUT OFFSET VOLTAGE:
625µV max
● INPUTS PROTECTED TO ±40V
ISO254 is a precision three-port isolated programmable gain instrumentation amplifier incorporating a
novel duty cycle modulation-demodulation technique
and has excellent accuracy. Internal input protection
can withstand up to ±40V input differential without
damage. The signal is transmitted digitally across a
differential capacitive barrier. With digital modulation
the barrier characteristics do not affect signal integrity.
This results in excellent reliability and good high
frequency transient immunity across the barrier. The
DC/DC converter, amplifier and barrier capacitors are
housed in a plastic DIP.
● BIPOLAR OPERATION: VO = ±10V
● SYNCHRONIZATION CAPABILITY
● 28-PIN PLASTIC DIP: 0.6" Wide
This amplifier is easy to use as no external components are required. A power supply range of 11V to
18V makes this amplifier ideal for a wide range of
applications.
● PROGRAMMABLE GAINS OF
1, 10, 100, 1000
APPLICATIONS
2
1
A1
● INDUSTRIAL PROCESS CONTROL
Transducer Isolator, Thermocouple
Isolator, RTD Isolator, Pressure Bridge
Isolator, Flow Meter Isolator
● POWER MONITORING
● MEDICAL INSTRUMENTATION
3
A0
ISO254
+VIN
VOUT
PGA
4
● ANALYTICAL MEASUREMENTS
● BIOMEDICAL MEASUREMENTS
● DATA ACQUISITION
26
28
● TEST EQUIPMENT
● GROUND LOOP ELIMINATION
27
25
14
–VIN
Com1
Com2
+VS1
+VS2
–VS2
–VS1
GND1
GND2
GND3 SYNC
17
16
13
12
11
10
+VS3
15
International Airport Industrial Park • Mailing Address: PO Box 11400
Tel: (520) 746-1111 • Twx: 910-952-1111 • Cable: BBRCORP •
• Tucson, AZ 85734 • Street Address: 6730 S. Tucson Blvd. • Tucson, AZ 85706
Telex: 066-6491 • FAX: (520) 889-1510 • Immediate Product Info: (800) 548-6132
©
PDS-1308B
1996 Burr-Brown Corporation
Printed in U.S.A. April, 1996
SPECIFICATIONS
At TA = +25°C, +VS3 = 15V, RL = 2kΩ, and 220nF capacitors on all generated supplies, unless otherwise noted.
ISO254P
PARAMETER
ISOLATION
Voltage Rated Continuous:
AC
100% Test (AC 50Hz)
Rated One Min
Isolation-Mode Rejection
DC
AC 50Hz
Barrier Impedance
Leakage Current
GAIN
Gain Error
Gain vs Temperature
Nonlinearity
CONDITIONS
MIN
TMIN to TMAX
1s; Partial Discharge ≤ 5pC
1500
2500
2500
TYP
VISO = 240Vrms, 50Hz
G=1
G = 10
G = 100
G = 1000
G=1
G = 10
G = 100
G = 1000
G=1
G = 10
G = 100
G = 1000
0.15
0.15
0.15
0.2
±15
±15
±15
±15
±0.01
±0.01
0.01
±0.01
INPUT OFFSET VOLTAGE
Initial Offset
vs Temperature
CMRR
vs Supply
±(1 + 510/G)
90
1
INPUT
Voltage Range
Bias Current
vs Temperature
Offset Current
vs Temperature
±10
±8
±8
OUTPUT
Voltage Range
Current Drive
Capacitive Load Drive
Ripple Voltage
FREQUENCY RESPONSE
Small Signal Bandwidth
Slew Rate
Settling Time, 0.1%
POWER SUPPLIES
Rated Voltage
Voltage Range
Quiescent Current
Rated Output Voltage
G=1
G = 10
G = 100
G = 1000
±0.3
%
±0.3
%
±0.102
ppm/°C
ppm/°C
ppm/°C
ppm/°C
%
±0.104
%
±(0.125 +101/G)
mV
µV/°C
dB
mV/V
±5
±5
No Load
50mA Load On Two Supplies
11
25
13
12
0.1
25
50
30
10
1
0.5
80
380
490
1650
kHz
kHz
kHz
kHz
V/µs
µs
µs
µs
µs
40
14.5
13.2
35
1
1
18
55
16
1.4
50
TEMPERATURE RANGE
Operating
Storage
–40
–40
®
2
V
nA
pA/°C
nA
pA/°C
V
mA
µF
mVp-p
15
Load Regulation
Line Regulation
SYNC Frequency
Output Voltage Ripple
ISO254
2
dB
dB
Ω || pF
µArms
±10
±5
G=1
G = 10
G = 100
G = 1000
UNITS
Vrms
Vrms
Vrms
120
95
1014 || 2
1.4
1500Vrms
MAX
85
85
V
V
mA
V
V
mV/mA
V/V
MHz
mV
°C
°C
ABSOLUTE MAXIMUM RATINGS
PIN CONFIGURATION
Supply Voltage ................................................................................... +18V
VIN, Analog Input Voltage Range ....................................................... ±40V
Com1 to GND1 .................................................................................... ±1V
Com2 to GND2 .................................................................................... ±1V
Continuous Isolation Voltage ..................................................... 1500Vrms
..................................................................................... 2500Vrms one min
IMV, dv/dt ...................................................................................... 20kV/µs
Junction Temperature ...................................................................... 150°C
Storage Temperature ........................................................ –40°C to +85°C
Lead Temperature (soldering, 10s) ................................................ +300°C
Output Short Duration .......................................... Continuous to Common
A0
1
28 +VS1
A1
2
27 –VS1
–VIN
3
26 Com1
+VIN
4
25 GND1
ELECTROSTATIC
DISCHARGE SENSITIVITY
GND2 10
+VS2 12
17 GND3
Any integrated circuit can be damaged by ESD. Burr-Brown
recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling
and installation procedures can cause damage.
Com2 13
16 SYNC
–VS2 11
VOUT 14
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits
may be more susceptible to damage because very small
parametric changes could cause the device not to meet
published specifications.
PACKAGE INFORMATION
PACKAGE
PACKAGE DRAWING
NUMBER(1)
28-Pin Plastic DIP
335
PRODUCT
ISO254P
NOTE: (1) For detailed drawing and dimension table, please see end of data
sheet, or Appendix C of Burr-Brown IC Data Book.
ORDERING INFORMATION
PRODUCT
15 +VS3
PACKAGE
ISO254P
28-Pin Plastic DIP
TYPICAL PERFORMANCE CURVES
At TA = +25°C, +VS3 = 15V, RL = 2kΩ, and 220nF capacitors on all generated supplies, unless otherwise noted.
PSRR vs FREQUENCY
(G = 10)
80
80
60
60
PSRR (dB)
PSRR (dB)
PSRR vs FREQUENCY
(G = 1)
40
40
20
20
0
0
1
10
100
1K
10K
1
100K
10
100
1k
10k
100k
Frequency (Hz)
Frequency (Hz)
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user's own risk. Prices and specifications are subject to change
without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant
any BURR-BROWN product for use in life support devices and/or systems.
®
3
ISO254
TYPICAL PERFORMANCE CURVES (CONT)
At TA = +25°C, +VS3 = 15V, RL = 2kΩ, and 220nF capacitors on all generated supplies, unless otherwise noted.
ISOLATION LEAKAGE CURRENT vs FREQUENCY
(V = 240Vrms)
IMR vs FREQUENCY
120
1k
Rejection (dB)
µAmps (rms)
100
100
10
80
60
40
1
10
1
100
1k
10k
1
100k
SIGNAL RESPONSE vs CARRIER FREQUENCY
SINE RESPONSE
(f = 1kHz, G = 1)
Input (V)
0
–20
Signal (dB)
1k
10k
1500
2000
10
–10
–30
5
0
–5
–40
5
–50
Output (V)
–60
–70
–80
–90
0
100k
200k
300k
400k
500k
600k
700k
0
–5
–10
800k
0
Frequency (Hz)
500
1000
Time (µs)
PULSE RESPONSE
(f = 1kHz, G = 1)
SINE RESPONSE
(f = 10kHz, G = 1)
10
Input (V)
10
5
0
5
0
–5
–5
5
5
Output (V)
Input (V)
100
Frequency (Hz)
10
Output (V)
10
Frequency (Hz)
0
–5
0
–5
–10
–10
0
50
100
150
0
200
®
ISO254
500
Time (µs)
Time (µs)
4
1000
TYPICAL PERFORMANCE CURVES (CONT)
At TA = +25°C, +VS3 = 15V, RL = 2kΩ, and 220nF capacitors on all generated supplies, unless otherwise noted.
PULSE RESPONSE
(f = 10kHz, G = 1)
GAIN vs FREQUENCY
10
60
Input (V)
G = 1000
5
40
G = 100
Gain (dB)
0
–5
5
20
G = 10
0
Output (V)
G=1
0
–20
–5
–40
–10
0
20
40
60
80
1
100
100
10k
100k
Time (µs)
COMMON-MODE REJECTION vs FREQUENCY
INPUT COMMON-MODE RANGE
vs OUTPUT VOLTAGE
1M
100
Common-Mode Voltage (V)
15
G =1000
G = 100
80
G=1
G = 10
60
10
100
1k
10k
10
G ≥ 10
G=1
5
G=1
VD/2
0
VD/2
–5
–
VO
+
–
+
VCM
–10
–15
–15
100k
G ≥ 10
–10
–5
Frequency (Hz)
0
5
10
15
Output Voltage (V)
INPUT BIAS AND INPUT OFFSET CURRENT
vs TEMPERATURE
ISOLATION MODE VOLTAGE
vs FREQUENCY
2
Max DC Rating
1
Peak Isolation Voltage
Input Bias and Input Offset Current (nA)
1k
Frequency (Hz)
120
Common-Mode Rejection (dB)
10
±IB
0
IOS
–1
–2
–75
2.1k
Max AC
Rating
1.0k
Degraded
Performance
100
Typical
Performance
10
–50
–25
0
25
50
75
100
125
100
Temperature (°C)
1k
10k
100k
1M
10M
100M
Frequency (Hz)
®
5
ISO254
BASIC OPERATION
INPUT COMMON-MODE RANGE
The linear common-mode range of the input circuitry of the
ISO254 is approximately ±12.7V (or 2.3V from the power
supplies). As the output voltage increases, however, the
linear input range will be limited by the output voltage swing
of the internal amplifiers. Thus, the linear common-mode
range is related to the output voltage of the complete input
amplifier—see performance curves “Input Common-Mode
Range vs Output Voltage.”
ISO254 is a precision, powered, three-port isolated programmable-gain amplifier. The input and output sections are
galvanically isolated by matched and EMI shielded capacitors built into the plastic package. The DC/DC converter
input is also galvanically isolated from both the input and
output supplies.
SIGNAL AND POWER CONNECTIONS
A combination of common-mode and differential input
voltage can cause the output voltage of the internal amplifiers to saturate. For applications where input common-mode
range must be maximized, limit the output voltage swing by
selecting a lower gain of the programmable-gain input.
Figure 1 shows proper power and signal connections. The
power supply input pin +VS3 should be bypassed with a
2.2µF tantalum capacitor and the outputs VS1 and VS2 with
220nF ceramic capacitors located as close to the amplifier as
possible. All ground connections should be run independently to a common point. Signal Common on the output
section provides a low-impedance point for sensing signal
ground in noisy applications. Com1 and Com2 must have a
path to ground for signal current return and should be
maintained within ±1V of GND1 and GND2 respectively.
Input-overload can produce an output voltage that appears
normal. For example, an input voltage of +20V on one input
and +40V on the other input will exceed the linear commonmode range of both input amplifiers. Since both input
amplifiers are saturated to nearly the same output voltage
limit, the difference voltage measured by the output amplifier will be near zero. The output of the programmable-gain
amplifier will be near 0V even though both inputs are
overloaded.
GAIN
A1
A0
1
10
100
1000
0
0
1
1
0
1
0
1
1
2
A1
A0
ISO254
4 +VIN
VIN
VOUT 14
PGA
VOUT
3 –VIN
+15VOUT
–15VOUT
26 Com1
Com2 13
28 +VS1
+VS2 12
27 –VS1
–VS2 11
+15VOUT
–15VOUT
GND2 10
25 GND1
GND3 SYNC +VS3
17
VCM
220nF
16
220nF
15
2.2µF
SYNC +15V
FIGURE 1. Basic Connections.
®
ISO254
6
220nF
220nF
INPUT PROTECTION
The inputs of the programmable-gain amplifiers are individually protected for voltages up to ±40V. Internal circuitry
on each input provides low series impedance under normal
signal conditions. If the input is overloaded, the protection
circuitry limits the input current to a safe value (approximately 1.5mA). The inputs are protected even if no power
supply is present.
When connecting up to eight ISO254’s without a driver the
unit with the highest natural frequency will determine the
synchronized running frequency. The SYNC pin is sensitive
to capacitive loading: 150pF or less is recommended. If
unused, the SYNC pin should be left open. Avoid shorting
the SYNC pin directly to ground or supply potentials;
otherwise damage may result.
Soft start circuitry protects the MOSFET switches during
startup. This is accomplished by holding the gate-to-source
voltage of both MOSFET switches low until the free-running oscillator is fully operational. In addition, soft start
circuitry and input current sensing also protects the switches.
This current limiting keeps the MOSFET switches operating
in their safe operating area under fault conditions or excessive loads. When either of these conditions occur, the peak
input current exceeds a safe limit. The result is an approximate 5% duty cycle, 300µs drive period to the MOSFET
switches. This protects the internal MOSFET switches as
well as the external load from any thermal damage. When
the fault or excessive load is removed, the converter resumes
normal operation. A delay period of approximately 50µs
incorporated in the current sensing circuitry allows the
output filter capacitors to fully charge after a fault is removed. This delay period corresponds to a filter capacitance
of no more than 1µf at either of the output pins. This
provides full protection of the MOSFET switches and also
sufficiently filters the output ripple voltage. The current
sensing circuitry is designed to provide thermal protection
for the MOSFET switches over the operating temperature
range as well. When these conditions are exceeded, the unit
will go into its shutdown mode.
DC/DC CONVERTER
ISO254 provides a reliable solution to the need for integral
power. The high isolation rating being achieved by careful
design and attention to the physical construction of the
transformer. In addition to the high dielectric strength a low
leakage coating increases the isolation voltage range. The
soft start oscillator/driver design eliminates high inrush
currents during turn-on. Input current sensing protects both
the converter and the load from possible thermal damage
during a fault condition. The DC/DC converter is synchronized to the amplifier and when multiple ISO254’s are used,
each channel can be synchronized via the SYNC pin.
The DC/DC converter consists of a free-running oscillator,
control and switch driver circuitry, MOSFET switches, a
transformer, rectifier diodes and filter capacitors all contained within the ISO254 package. The control circuitry
consists of current limiting, soft start and synchronization
features. In instances where several ISO254’s are used in a
system, beat frequencies developed between the ISO254’s
are a potential source of low frequency noise in the supply
and ground paths. This noise may couple into the signal path
and can be avoided by synchronizing the individual ISO254’s
together by tying the SYNC pins together or using the circuit
in Figure 2 to drive the SYNC pins from an external source.
MC1472
or Equivalent
Peripheral
Driver
+5V
OUTPUT CURRENT RATINGS
The total current which can be drawn from each output
supply on the ISO254 is a function of the total power drawn
from all outputs. For example if three outputs are not used
then maximum current can be drawn from one output. In all
cases, the total maximum current that can be drawn from any
combination of outputs is:
+15V
I1+ + I1– + I2+ + I2– ≤ 50mΑ
330Ω
2N3904
TTL
SYNC
+VS3, GND3
The waveform of the ground return current is an 800kHz
sawtooth. A capacitor between +VS3 and GND3 provides a
bypass for the AC portion of this current. The power should
never be instantaneously interrupted to the ISO254 (i.e., a
break in the line to +VS3 either by accidental or switch
means.) Normal power down of the +VS3 supply is not
considered instantaneous. Should a rapid break in input
power occur the internal transformers voltage will rapidly
rise to maintain current flow and may cause internal damage
to the ISO254.
ISO254
620Ω
2N3904
16
15
17
100Ω
ISO254
16
15
17
To Other
ISO254’s
FIGURE 2. External SYNC drive.
®
7
ISO254
SYNCHRONIZED OPERATION
ISO254 can be synchronized to an external signal source.
This capability is useful in eliminating troublesome beat
frequencies in multi-channel systems and in rejecting AC
signals and their harmonics. To use this feature, tie all sync
pins together or apply an external signal to the SYNC pin.
ISO254 can be synchronized to an external oscillator over
the range 1-1.4MHz (this corresponds to a modulation frequency of 500kHz to 700kHz as SYNC is internally divided
by 2).
Due to effects of very high-frequency signals, typical IMV
performance can be achieved only when dV/dT of the
isolation mode voltage falls below 1000V/µs. For convenience, this is plotted in the typical performance curves
for the ISO254 as a function of voltage and frequency for
sinusoidal voltages. When dV/dT exceeds 1000V/µs but
falls below 20kV/µs, performance may be degraded. At rates
of change above 20kV/µs, the amplifier may be damaged,
but the barrier retains its full integrity. Lowering the power
supply voltage below 15V may decrease the dV/dT to
500V/µs for typical performance, but the maximum dV/dT
of 20kV/µs remains unchanged.
CARRIER FREQUENCY CONSIDERATIONS
ISO254 amplifiers transmit the signal across the ISO-barrier
by a duty-cycle modulation technique. This system works
like any linear amplifier for input signals having frequencies
below one half the carrier frequency, fC. For signal frequencies above fC/2, the behavior becomes more complex. The
“Signal Response vs Carrier Frequency” performance curve
describes this behavior graphically. The upper curve illustrates the response for input signals varying from DC to fC/
2. At input frequencies at or above fC/2, the device generates
an output signal component that varies in both amplitude
and frequency, as shown by the lower curve. The lower
horizontal scale shows the periodic variation in the frequency of the output component. Note that at the carrier
frequency and its harmonics, both the frequency and amplitude of the response go to zero. These characteristics can be
exploited in certain applications.
Leakage current is determined solely by the impedance of
the barrier and transformer capacitance and is plotted in the
“Isolation Leakage Current vs Frequency” curve.
ISOLATION VOLTAGE RATINGS
Because a long-term test is impractical in a manufacturing
situation, the generally accepted practice is to perform a
production test at a higher voltage for some shorter time.
The relationship between actual test voltage and the continuous derated maximum specification is an important one.
Historically, Burr-Brown has chosen a deliberately conservative one: VTEST = (2 x ACrms continuous rating) +
1000V for 10 seconds, followed by a test at rated ACrms
voltage for one minute. This choice was appropriate for
conditions where system transients are not well defined.
Recent improvements in high-voltage stress testing have
produced a more meaningful test for determining maximum
permissible voltage ratings, and Burr-Brown has chosen to
apply this new technology in the manufacture and testing of
the ISO254.
It should be noted that for the ISO254, the carrier frequency
is nominally 400kHz and the –3dB point of the amplifier is
50kHz. Spurious signals at the output are not significant
under these circumstances unless the input signal contains
significant components above 200kHz.
When periodic noise from external sources such as system
clocks and DC/DC converters are a problem, ISO254 can be
used to reject this noise. The amplifier can be synchronized
to an external frequency source, fEXT, placing the amplifier
response curve at one of the frequency and amplitude nulls
indicated in the “Signal Response vs Carrier Frequency”
performance curve.
Partial Discharge
When an insulation defect such as a void occurs within an
insulation system, the defect will display localized corona or
ionization during exposure to high-voltage stress. This ionization requires a higher applied voltage to start the
discharge and lower voltage to maintain it or extinguish it
once started. The higher start voltage is known as the
inception voltage, while the extinction voltage is that level
of voltage stress at which the discharge ceases. Just as the
total insulation system has an inception voltage, so do the
individual voids. A voltage will build up across a void until
its inception voltage is reached, at which point the void will
ionize, effectively shorting itself out. This action redistributes electrical charge within the dielectric and is known as
partial discharge. If, as is the case with AC, the applied
voltage gradient across the device continues to rise, another
partial discharge cycle begins. The importance of this
phenomenon is that, if the discharge does not occur, the
insulation system retains its integrity. If the discharge begins, and is allowed to continue, the action of the ions and
electrons within the defect will eventually degrade any
organic insulation system in which they occur. The measurement of partial discharge is still useful in rating the devices
ISOLATION MODE VOLTAGE
Isolation Mode Voltage (IMV) is the voltage appearing
between isolated grounds GND1 and GND2. The IMV can
induce errors at the output as indicated by the plots of IMV
vs Frequency. It should be noted that if the IMV frequency
exceeds fC/2, the output will display spurious outputs in a
manner similar to that described above, and the amplifier
response will be identical to that shown in the “Signal
Response vs Carrier Frequency” performance curve. This
occurs because IMV-induced errors behave like inputreferred error signals. To predict the total IMR, divide the
isolation voltage by the IMR shown in “IMR vs Frequency”
performance curve and compute the amplifier response to
this input-referred error signal from the data given in the
“Signal Response vs Carrier Frequency” performance curve.
®
ISO254
8
and providing quality control of the manufacturing process.
The inception voltage for these voids tends to be constant, so
that the measurement of total charge being redistributed
within the dielectric is a very good indicator of the size of the
voids and their likelihood of becoming an incipient failure.
The bulk inception voltage, on the other hand, varies with
the insulation system, and the number of ionization defects
and directly establishes the absolute maximum voltage (transient) that can be applied across the test device before
destructive partial discharge can begin. Measuring the bulk
extinction voltage provides a lower, more conservative voltage from which to derive a safe continuous rating. In
production, measuring at a level somewhat below the expected inception voltage and then de-rating by a factor
related to expectations about system transients is an accepted practice.
measurement of RF noise to detect ionization. This method
was not quantitative with regard to energy of the discharge,
and was not sensitive enough for small components such as
isolation amplifiers. Now, however, manufacturers of HV
test equipment have developed means to quantify partial
discharge. VDE in Germany, an acknowledged leader in
high-voltage test standards, has developed a standard test
method to apply this powerful technique. Use of partial
discharge testing is an improved method for measuring the
integrity of an isolation barrier.
To accommodate poorly-defined transients, the part under
test is exposed to voltage that is 1.6 times the continuousrated voltage and must display less than or equal to 5pC
partial discharge level in a 100% production test.
APPLICATIONS
The ISO254 isolation amplifiers are used in three categories
of applications:
Partial Discharge Testing
Not only does this test method provide far more qualitative
information about stress-withstand levels than did previous
stress tests, but it provides quantitative measurements from
which quality assurance and control measures can be based.
Tests similar to this test have been used by some manufacturers, such as those of high-voltage power distribution
equipment, for some time, but they employed a simple
• Accurate isolation of signals from high voltage ground
potentials
• Accurate isolation of signals from severe ground noise and
• Fault protection from high voltages in analog measurements
+15V
1nF
2.2nF
+15 (+VS2)
15
17
0.1µF
GND3
+VS3
4
+VIN
VOUT
VSIGNAL
(0 - 5V)
16kΩ
14
16kΩ
OPA27
1nF
3
–VIN
0.1µF
ISO254
26
28
27
220nF
COM1
+VS1
–VS1
COM2
+VS2
–VS2
13
–15 (–VS2)
12
20kΩ
11
220nF
220nF
220nF
25
GND1
AO
1
GND2
A1
VOUT = 2VIN
20kΩ
10
2
FIGURE 3. Noise Reduction in Data Acquisition System.
®
9
ISO254