VDE JG-RELAYS 8 A POWER RELAY FEATURES 22 .866 14 .551 11.6 .457 • Compact & flat design: 22 mm .866 inch (length) × 14 mm .551 inch (width) × 11.6 mm .457 inch (height) • High capacity: 8 A nominal switching capacity • High surge resistance: Min. 10,000 V between contact and coil • High sensitivity: 200 mW nominal operating power • VDE, TÜV, SEMKO also approved mm inch SPECIFICATIONS Contact Characteristics Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1A) Contact material Rating (resistive load) Expected life (min. operations) 1 Form A 100 mΩ Silver alloy 8 A 125 V AC Nominal switching capacity 5 A 250 V AC 5 A 30 V DC Max. switching power 1,250 VA, 150 W Max. swtiching voltage 250 V AC, 110 V DC (0.3 A) Max. switching current 8 A (AC), 5A (DC) Mechanical (at 180 cpm) 5×106 Electrical (at 8 A 125 V AC) (at 20 cpm) 105 Coil Nominal operating power Max. operating speed Initial insulation resistance*1 Between open contacts Between contacts and coil Surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time*4 (at nominal voltage)(without diode) Initial breakdown voltage*2 Temperature rise (Ambient temperature: 70°C) Shock resistance 200 mW TYPICAL APPLICATIONS • Microwave ovens • Small household appliances • Water heaters • Electric irons • Coffee makers Functional*5 Destructive*6 Functional*7 Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current; 10 mA *3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 *4 Excluding contact bounce time *5 Half-wave pulse of sine wave: 11ms; detection time: 10µs *6 Half-wave pulse of sine wave: 6ms *7 Detection time: 10µs *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). 20 cpm Vibration resistance Destructive Min. 100 mΩ at 500 V DC 750 Vrms for 1 min. 2,000 Vrms for 1 min. Min. 10,000 V Approx. 5 ms Approx. 3 ms Max. 45°C with nominal coil voltage and at 8 A contact current Min. 98 m/s2 {10 G} Min. 980 m/s2 {100 G} 98 m/s2 {10 G}, 10 to 55 Hz at double amplitude of 1.6 mm 117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2 mm Conditions for operation, Ambient transport and storage*8 temp. (Not freezing and condensHumidity ing at low temperature) Unit weight –40°C to +70°C –40°F to +158°F 5 to 85% R.H. Approx. 7 g .25 oz ORDERING INFORMATION Ex. JG1aF 24V Coil voltage (DC) 5, 6, 9, 12, 18, 24 V Note: Standard packing: 100 pcs. Case: 500 pcs. UL/CSA, VDE approved type is standard. 73 JG TYPES AND COIL DATA Part No. Nominal voltage, V DC Pick-up voltage, V DC (max.) (at 20°C 68°F) Drop-out voltage, V DC (mim.) (at 20°C 68°F) Coil resistance, Ω (±10%) (at 20°C 68°F) JG1aF-5V JG1aF-6V JG1aF-9V JG1aF-12V JG1aF-18V JG1aF-24V 5 6 9 12 18 24 4.0 4.8 7.2 9.6 14.4 19.2 0.25 0.3 0.45 0.6 0.9 1.2 125 180 405 720 1,620 2,880 Nominal operating current. mA (±10%) (at 20°C 68°F) 40 33 22 17 11 8.3 Nominal operating power, mW Max. allowable voltage, V DC (at 70°C 158°F) 200 200 200 200 200 200 6.5 7.8 11.7 15.6 23.4 31.2 DIMENSIONS mm inch PC board pattern (Copper-side view) 22 .866 2-1.3 dia. 2-.051 dia. 14 .551 11.2 .441 2-0.9 dia. 2-.035 dia. 15.24 .600 7.62 .300 10.16 .400 4.3 0.4 .169 .016 2.54 .100 5.08 .200 7.62 .300 17.78 .700 15.24 .600 Tolerance: ±0.1 ±.004 COM 3 2 10.16 .400 4 N.O. 1 Dimension: Max. 1mm .039 inch: 1 to 5mm .039 to .118 inch: Min. 5mm .118 inch: 2.11 .083 General tolerance ±0.2±.008 ±0.3 ±.012 ±0.4 ±.016 REFERENCE DATA 1. Maximum value for switching capacity 2. Operate/release time 3. Coil temperature rise Point measured: Inside the coil Contact current: 8A 10 1 8 Operate time 6 2 10 Release time 0 100 250 Max. Max. – x– x Min. Min. 4 80 90 Contact voltage, V 100 110 120 5. Life curve Operation frequency: 20 times/min. (ON/OFF = 1.5 s : 1.5 s) Ambient temperature: Room temperature 100 Allowable ambient temperatures against % coil voltages (max. inside the coil temperature set as 115°C 239°F) 200 Max. allowable voltage 125V AC resistive load Life, ×104 Voltage, %V 300 10 250V AC resistive load 100 Pick-up voltage 0 20 40 60 80 Ambient temperature, °C 74 1 0 2 4 6 8 Contact current, A 30 Ambient temperature 70°C 20 10 80 90 100 110 120 130 Coil applied voltage, %V Coil applied voltage, %V Contact current: 8 A Ambient temperature 30°C 40 0 130 4. Ambient temperature characteristics Temperature rise, °C AC resistive load Operate/release time, ms Contact current, A 100 10 JG 6. Electrical life test (5.8 A 100 V AC resistive load) 100 V AC 650 W heater Welding and mis-contact detection Weding detection: 0.5s Mis-contact detection: 0.2s Change of contact resistance 100 Contact resistance, mΩ Circuit Pick-up and drop-out voltage, V Change of pick-up and drop-out voltage Sample: JG1aF-12V, 6 pcs. Operating speed: 20 cpm Ambient temperature: 80°C 176°F 10 Pick-up voltage Max. – x Min. 5 Drop-out voltage 0 5 80 60 40 Max. – x Min. 20 Max. – x Min. 0 10 5 7. Electrical noise resistance characteristics between contact and coil Sample: JG1aF-12V 10 No. of operations, ×104 No. of operations, ×10 4 Noise wave Output wave 10,000 9,500 50 Digital memory 75Ω Output voltage, V Surge simulator Applied voltage, V Circuit 8,000 6,000 40 30 4,000 20 2,000 10 0 1 2 Time, µs 3 4 0 1 2 3 4 Time, µs For Cautions for Use, see Relay Technical Information (Page 11 to 39). 75