FLAT TYPE POWER RELAY 22 .866 JV-RELAYS FEATURES 16 .630 • Flat type: 16 mm (length) × 22 mm (width) × 10.9 mm (height) (.630×.866×.429 inch) • High capacity type (16A) available • High sensitivity type (100 mW: 1 Form A) available • TÜV also approved 10.9 .429 mm inch SPECIFICATIONS Contact Standard type Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Rating (resistive) 1 Form A 1 Form C Characteristics High capacity High type sensitivity type 1 Form A 1 Form A Max. operating speed Initial insulation resistance*1 Between open Initial contacts breakdown Between convoltage*2 tacts and coil 50 mΩ Max. switching power Max. switching voltage Max. switching current Silver alloy 10 A 125 V AC (N.O.) 10 A 125 V AC 16 A 125 V AC 10 A 125 V AC 6 A 125 V AC (N.C.) 1,250 VA (N.O.) 1,250 VA 2,000 VA 1,250 V 750 VA (N.C.) 125 V AC 10 A (N.O.) 10 A 16 A 10 A 6 A (N.C.) Expected life (min. ope.) Mechanical at (180 cpm) Electrical at resistive Sealed type (at 20 cpm) Flux-resistant (at rated load) type Operate time*3 (at nominal voltage) Release time (without diode)*3 (at nominal voltage) 107 Coil 105 105 3×104 5×104 3×105 105 105 105 1 Form A type 200 mW (up to 48 V coil type) Nominal Standard type 600 mW (100 V coil type) operating High capacity type power High sensitivity type 100 mW 20 cpm Min. 100 MΩ (at 500 V DC) 1,000 Vrms for 1 min. 1,500 Vrms for 1 min. Approx. 10 ms Approx. 5 ms (100 V DC coil type) Approx. 4 ms Max. 65°C with nominal coil voltage across coil and at nominal switching capacity Temperature rise (at 50°C) Functional*4 Shock resistance Destructive*5 Min. 98 m/s2 {10 G} Min. 980 m/s2 {100 G} 10 to 55 Hz Functional*6 at double amplitude of 1.0 mm Vibration resistance 10 to 55 Hz Destructive at double amplitude of 1.6 mm Conditions for opera- Ambient –40°C to +70°C*8 tion, transport and temp. –40°F to +158°F storage*7 (Not freezing and Humidity 5 to 85%R.H. condensing at low temperature) 1 Form C type 400 mW (up to 48 V coil type) 600 mW (100 V coil type) — — Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage"section *2 Detection current: 10mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms, detection time: 10µs *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10µs *7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). *8 100V type: –40 to + 60°C –40 to + 140°F Unit weight Approx. 8 g .282 oz TYPICAL APPLICATIONS 1. Home appliances: Air conditioner, heater, etc. 2. Automotive: Power supply for car stereo and air conditioner ORDERING INFORMATION Ex. JV 1a P F Contact arrangement Rating Protective construction 1: 1 Form C 1a: 1 Form A Nil: Standard type P: High capacity type* Nil: Sealed type F: Flux-resistant type S 12V Sensitivity Nil: Standard type (1 Form A: 200 mW, 1Form C: 400 mW 100 V DC coil type: 600 mW) S: High sensitivity type* (1 Form A: 100 mW) Notes: 1. Standard packing: Carton: 50 pcs.; Case: 1,000 pcs. 2. Coil voltage DC 48, 100 V types are not available for high sensitivity type. UL/CSA, TÜV approved type is standard. Coil voltage (DC) 5, 6, 9, 12, 18, 24, 48, 100V * Only for 1 Form A type 87 JV TYPES Contact arrangement Coil voltage, V DC 5 6 9 12 18 24 48 100 5 6 9 12 18 24 48 100 5 6 9 12 18 24 5 6 9 12 18 24 48 100 1 Form A Standard type 1 Form A High capacity type 1 Form A High sensitivity type 1 Form C Sealed type JV1a-5V JV1a-6V JV1a-9V JV1a-12V JV1a-18V JV1a-24V JV1a-48V JV1a-100V JV1aP-5V JV1aP-6V JV1aP-9V JV1aP-12V JV1aP-18V JV1aP-24V JV1aP-48V JV1aP-100V JV1aS-5V JV1aS-6V JV1aS-9V JV1aS-12V JV1aS-18V JV1aS-24V JV1-5V JV1-6V JV1-9V JV1-12V JV1-18V JV1-24V JV1-48V JV1-100V Part No. Flux-resistant type JV1aF-5V JV1aF-6V JV1aF-9V JV1aF-12V JV1aF-18V JV1aF-24V JV1aF-48V JV1aF-100V JV1aPF-5V JV1aPF-6V JV1aPF-9V JV1aPF-12V JV1aPF-18V JV1aPF-24V JV1aPF-48V JV1aPF-100V JV1aFS-5V JV1aFS-6V JV1aFS-9V JV1aFS-12V JV1aFS-18V JV1aFS-24V JV1F-5V JV1F-6V JV1F-9V JV1F-12V JV1F-18V JV1F-24V JV1F-48V JV1F-100V COIL DATA (at 20°C 68°F) Part No. 1 Form A (Standard type & High capacity type) 1 Form A (High sensitivity type) 1 Form C 88 Nominal voltage, V DC Pick-up voltage, V DC (max.) 5 6 9 12 18 24 48 100 5 6 9 12 18 24 5 6 9 12 18 24 48 100 4.0 4.8 7.2 9.6 14.4 19.2 38.4 48 4.0 4.8 7.2 9.6 14.4 19.2 4.0 4.8 7.2 9.6 14.4 19.2 38.4 70 Drop-out voltage, V DC (min.) 0.25 0.3 0.45 0.6 0.9 1.2 2.4 3 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 2.4 5 Coil resistance, Ω (±10%) 125 180 405 720 1,620 2,880 11,520 16,600 250 360 810 1,440 3,240 5,760 62.5 90 202.5 360 810 1,440 5,760 16,600 Nominal operating current, mA (±10%) 40 33.3 22.2 16.7 11.1 8.3 4.2 6 20 16.7 11.1 8.3 5.6 4.2 80 66.7 44.4 33.3 22.2 16.7 8.3 6 Nominal operating power, mW 200 200 200 200 200 200 200 600 100 100 100 100 100 100 400 400 400 400 400 400 400 600 Max. allowable voltage, V DC 7.5 9 13.5 18 27 36 72 110 9 10.8 16.2 21.6 32.4 43.2 6.5 7.8 11.7 15.6 23.4 31.2 62.4 110 JV DIMENSIONS mm inch 1 Form A type 1 Form C type 22 .866 16 .630 22 .866 16 .630 10.5 0.4 .413 .016 10.5 0.4 .413 .016 4 .157 4 .157 PC board pattern (Copper-side view) 17.78 .700 2 17.78 .700 1 PC board pattern (Copper-side view) 17.78 .700 2-0.9 dia. 2-.035 dia. 2 12.7 .500 COM 3 NO 2-0.9 dia. 2-.035 dia. 12.7 .500 NC 5 4 17.78 .700 1 COM 3 12.7 .500 10.16 .400 2-1.3 dia. 2-.051 dia. Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .197 inch Min. 5mm .197 inch General tolerance ±0.2 ±.008 ±0.3 ±.012 ±0.4 ±.016 NO NC 5 4 10.16 .400 10.16 .400 12.7 .500 7.62 .300 3-1.3 dia. 3-.051 dia. Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .197 inch Min. 5mm .197 inch Tolerance: ±0.1 ±.004 10.16 .400 General tolerance ±0.2 ±.008 ±0.3 ±.012 ±0.4 ±.016 7.62 .300 Tolerance: ±0.1 ±.004 REFERENCE DATA 1.-(1) Maximum value for switching capacity (1 Form A type) 1.-(2) Maximum value for switching capacity (1 Form C type) 100 Contact current, A High capacity type, AC resistive load 16 10 Standard type, AC resistive load AC resistive load (NO side) 10 1 1 18 Operate/release time, ms 100 Contact current, A 2.-(1) Operate/release time (Standard 1 Form A type) 16 14 12 Operate time 10 8 6 4 Max. – x Min. Max. – x Min. Release time 2 100 10 1,000 100 16 14 12 10 Operate time 6 Release time 2 0 80 100 120 80 100 120 140 160 180 3.-(1) Coil temperature rise (1 Form A type) Measured portion: Inside the coil 18 4 0 Coil applied voltage, %V 2.-(3) Operate/release time (1 Form C type) Operate/release time, ms Operate/release time, ms 2.-(2) Operate/release time (High capacity 1 Form A type) 8 1,000 Contact voltage, V Contact voltage, V 140 160 Max. – x Min. Max. – x Min. 180 10 8 Operate time 6 Release time 2 0 80 100 80 120 140 60 10 A at 60°C 140°F (Standad type) 40 20 0 160 80 100 Coil applied voltage, %V 3.-(2) Coil temperature rise (1 Form C type) 3.-(3) Coil temperature rise (High sensitivity type) Measured portion: Inside the coil Measured portion: Inside the coil 10 A at 15°C 59°F (Standad type) 15 A at 60°C 140°F (High capacity type) Max. – x Min. Max. – x Min. 4 Coil applied voltage, %V 15 A at 26°C 79°F (High capacity type) Temperature rise, °C 10 120 140 160 180 Coil applied voltage, %V 4. Life curve Operation frequency: 20 times/min. (ON/OFF = 1.5s:1.5s) Ambient temperature: Room temperature 100 60 10 A at 25°C 77°F 60 40 125V AC resistive load 40 Life, ×104 80 Temperature rise, °C Temperature rise, °C Standard 200 mW type 10 High sensitivity 100 mW type 20 20 0 80 100 120 140 160 180 Coil applied voltage, %V 0 0 100 120 140 160 180 200 Coil applied voltage, %V 1 4 6 8 10 12 14 16 18 Contact current, A 89 JV Contact current: 10 A Contact current: 0 A, 10 A, 13 A, 15 A Contact current: 10 A Allowable ambient temperatures against % coil voltage (max. inside the coil temperature set as 115°C 239°F) 300 200 Pick-up voltage with a hot-start condition of 100%V on the coil 0 300 13 200 Pick-up voltage 0 20 40 60 80 100 0 120 A A Allowable ambient temperature against A % coil voltages (max. inside the coil temperature set as 13 A 15 A 115°C 239°F) Pick-up voltage with a hot-start condition of 100%V on the coil 10 A Pick-up voltage 0A 20 40 60 80 100 120 15 100 100 A 10 Coil applied voltage, %V 5.-(3) Ambient temperature characteristics (1 Form C type) Coil applied voltage, %V 5.-(2) Ambient temperature characteristics (High capacity 15 A type, 1 Form A) Coil applied voltage, %V 5.-(1) Ambient temperature characteristics (Standard 10 A type, 1 Form A) 200 Pick-up voltage 100 0 Ambient temperature, °C Ambient temperature, °C Allowable ambient temperatures against % coil voltages (max. inside the coil temperature set as 115°C 239°F) 20 40 60 80 Ambient temperature, °C 5.-(4) Ambient temperature characteristics (High sensitivity type) Contact current: 10 A Coil applied voltage, %V 300 High sensitivity 100 mW type Standard 200 mW type 200 Allowable ambient temperature against % coil voltages (max. inside the coil temperature set as 115°C 239°F) 100 0 0 20 40 60 80 100 120 Temperature rise, °C Types dedicated to a wider variety of automotive applications are available, upon receipt of order, with the following specifications: SPECIFICATIONS Contact Characteristics Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Rating (resistive Max. switching power load) Max. switching voltage Max. switching current Mechanical (at 300 cpm) Expected Electrical life (min. (DC 12 V motor, 6 A steady current, ope.) 20 A lock current)(at rated load) 1 Form C 100 mΩ Silver alloy 10 A 125 V AC 6A 30 V DC 1,250 V AC 180 W 125 V (AC) 30 V (DC) 10 A (AC) 6 A (DC) 5×106 Functional 4×104 Vibration resistance Destructive Coil Nominal voltage, V DC Nominal operating power Pick-up voltage, V DC (max.) Drop-out voltage; V DC (min.) Max. allowable voltage Max. operating speed Initial insulation resistance Initial break Between open contacts down voltage Between contacts and coil Operate time (at nominal voltage) Release time (at nominal voltage) Temperature rise (max.) (at nominal voltage)(at 50°C) Functional Shock resistance Destructive 5, 6, 9, 12, 18, 24 450 mW 70% of nominal voltage 5% of nominal voltage 150% of nominal voltage Conditions for operation, Ambient transport and storage temp. (Not freezing and condensHumidity ing at low temperature) Unit weight 20 cpm Min. 100 MΩ (at 500 V DC) 750 Vrms for 1 min. 1,500 Vrms for 1 min. Approx. 5 ms Approx. 4 ms 65°C with nominal coil voltage and at maximum allowable contact current Min. 196 m/s2 {20 G} Min. 980 m/s2 {100 G} 10 to 55 Hz at double amplitude of 1.6 mm 10 to 55 Hz at double amplitude of 2 mm –40°C to +70°C –40°F to +158°F 5 to 85%R.H. Approx. 8 g .282 oz For Cautions for Use, see Relay Technical Information (Page 11 to 39). 90