VDE HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY FEATURES 10 .394 20 .787 JQ-RELAYS • High electrical noise immunity • High switching capacity in a compact package • High sensitivity: 200 mW (1a), 400 mW (1c) • High surge voltage: 8,000 V between contacts and coil • VDE, TÜV, SEMKO also approved 15.6 .614 mm inch SPECIFICATIONS Contact Characteristics Standard type High capacity type 1 Form A, 1 Form C Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material 100 mΩ Silver alloy 5 A 125 V AC 10 A 125 V AC 1a 2 A 250 V AC 5 A 250 V AC 5 A 30 V DC 5 A 30 V DC Nominal 5 A 125 V AC 10 A 125 V AC N.O. 2 A 250 V AC 5 A 250 V AC switching 3 A 30 V AC 5 A 30 V DC capacity 1c 2 A 125 V AC 3 A 125 V AC Rating N.C. 1 A 250 V AC 2 A 250 V AC (resistive) 1 A 30 V DC 1 A 30 V DC 1a 625 VA, 150 W 1,250 VA, 150 W Max. switching N.O. 625 VA, 90 W 1,250 V AC, 150 W 1c power N.C. 250 VA, 30 W 500 V AC, 30 W Max. switching voltage 250 V AC, 110 V DC (0.3A) Max. switching current N.O.: 5 A N.C.: 2 A N.O.: 10 A N.C.: 3 A Expected mechanical life 107 (at 180 cpm)(min. operations) 1a Standard type N.O. 1c N.C. 1a High capacity type N.O. 1c N.C. Initial Between open contacts breakdown voltage*2 Between contacts and coil Surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time*4 (at nominal voltage)(without diode) Temperature rise*5 Functional*6 Shock resistance Destructive*7 Vibration resistance Functional*8 Destructive Conditions for operation, Ambient transport and storage*9 temp. (Not freezing and condensHumidity ing at low temperature) Unit weight Expected electrical life (min. operations) Type Max. operating speed Initial insulation resistance*1 Switching capacity 5 A 125 V AC 3 A 125 V AC 2 A 250 V AC 5 A 30 V DC 5 A 125 V AC 2 A 250 V AC 3 A 30 V DC No. of operations 5×104 2×105 2×105 105 5×104 2×105 105 2 A 125 V AC 1 A 250 V AC 1 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 2×105 2×105 105 5×104 5×104 105 5×104 5×104 105 3 A 125 V AC 2 A 250 V AC 1 A 30 V DC 2×105 2×105 105 1a: 200 mW 1c: 400 mW 20 cpm Min. 1,000 MΩ at 500 V DC 1a: 1,000 Vrms for 1 min. 1c: 750 Vrms for 1 min. 4,000 Vrms for 1 min. 8,000 V Approx. 5 ms Approx. 2 ms Max. 45°C Min. 294 m/s2 {30 G} Min. 980 m/s2 {100 G} 98 m/s2 {10 G}, 10 to 55 Hz at double amplitude of 1.6 mm 117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2.0 mm –40°C to +70°C –40°F to +158°F 5 to 85% R.H. Approx. 7 g .25 oz Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10 mA *3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 *4 Excluding contact bounce time *5 Measured conditions Standard type High capacity type Resistive, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70°C 158°F Resistive, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70°C 158°F *6 Half-wave pulse of sine wave: 11ms; detection time: 10µs *7 Half-wave pulse of sine wave: 6ms *8 Detection time: 10µs *9 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). Coil (at 20°C 68°F) Nominal operating power 79 JQ TYPICAL APPLICATIONS ORDERING INFORMATION • Air conditioners • Refrigerators • Microwave ovens • Heaters Ex. JQ 1a P 12 V Contact arrangement Contact capacity Coil voltage (DC) 1a: 1 Form A 1: 1 Form C Nil: Standard P: High capacity 5, 6, 9, 12, 18, 24, 48* V UL/CSA, VDE, SEMKO approved type is standard. * Available only for 1 Form C type TYPES AND COIL DATA at 20°C 68°F 1 Form C 80 Standard type High capacity type High capacity type Standard type 1 Form A Part No. JQ1a-5V JQ1a-6V JQ1a-9V JQ1a-12V JQ1a-18V JQ1a-24V JQ1aP-5V JQ1aP-6V JQ1aP-9V JQ1aP-12V JQ1aP-18V JQ1aP-24V JQ1-5V JQ1-6V JQ1-9V JQ1-12V JQ1-18V JQ1-24V JQ1-48V JQ1P-5V JQ1P-6V JQ1P-9V JQ1P-12V JQ1P-18V JQ1P-24V JQ1P-48V Nominal voltage, V DC Pick-up voltage, V DC (min.) Drop-out voltage, V DC (min.) Nominal operating current, mA 5 6 9 12 18 24 5 6 9 12 18 24 5 6 9 12 18 24 48 5 6 9 12 18 24 48 3.75 4.5 6.75 9 13.5 18 4 4.8 7.2 9.6 14.4 19.2 3.75 4.5 6.75 9 13.5 18 36 4 4.8 7.2 9.6 14.4 19.2 38.4 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 2.4 0.25 0.3 0.45 0.6 0.9 1.2 2.4 40 33.3 22.2 16.7 11.1 8.3 40 33.3 22.2 16.7 11.1 8.3 80 66.7 44.4 33.3 22.2 16.7 8.3 80 66.7 44.4 33.3 22.2 16.7 8.3 Nominal operating power, mW 200 200 400 400 Coil resistance, Ω (±10%) 125 180 405 720 1,620 2,880 125 180 405 720 1,620 2,880 62.5 90 202.5 360 810 1,440 5,760 62.5 90 202.5 360 810 1,440 5,760 Max. allowable voltage, V DC 180% of nominal voltage (at 20°C 68°F) 130% of nominal voltage (at 70°C 158°F) 150% of nominal voltage (at 20°C 68°F) 110% of nominal voltage (at 70°C 158°F) JQ mm inch DIMENSIONS 1 Form A 10 .394 1 Form A 20 .787 Schematic (Bottom view) 1 Form C COM N.O. COM Coil 15.6 .614 N.O. Coil N.C. 0.4 .016 4.2 .165 7.62 .300 10.16 .400 7.62 .300 7.62 .300 PC board pattern (Copper-side view) 1 Form A 1FormC 1 Form C 10 .394 20 .787 10.16 .400 4-1.3 dia. 4-.051 dia. 7.62 .300 10.16 .400 5-1.3 dia. 5-.051 dia. 7.62 .300 15.6 .614 7.62 .300 0.4 .016 7.62 .300 4.2 .165 5.08 .200 10.16 .400 Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .118 inch Min. 5mm .118 inch 2.54 .100 7.62 .300 Tolerance: ±0.1±.004 7.62 .300 General tolerance ±0.2 ±.008 ±0.3 ±.012 ±0.4 ±.016 REFERENCE DATA 1-(1). Max. switching capacity (1 Form A type) 1-(2). Max. switching capacity (1 Form C type) 100 AC resistive load (High capacity type) 10 5 Contact current, A Contact current, A 100 10 5 3 2 AC resistive load 1 (High capacity type) N.C. side AC resistive load (Standard type) N.C. side 1 AC resistive load (Standard type) 10 AC resistive load (High capacity type) N.O. side AC resistive load (Standard type) N.O. side 100 277 10 1,000 100 277 1,000 Contact voltage, V Contact voltage, V Standard type 1-(1). Operate & release time (1 Form A type) 1-(2). Operate & release time (1 Form C type) Tested sample: JQ1a-12V, 25 pcs. Tested sample: JQ1-24V, 25 pcs. 2. Life curve Ambient temperature: room temperature 6 Operate time 4 2 Release time 0 Max. Max. Min. Min. 8 6 Operate time 100 120 150 Coil applied voltage, %V 10 4 250V AC resistive load Max. Max. Min. Min. 2 Release time 0 80 125V AC resistive load Life, ×104 8 Operate & release time, ms Operate & release time, ms 100 80 100 120 150 Coil applied voltage, %V 1 0 1 2 3 4 5 Contact current, A 81 JQ 3-(1). Coil temperature rise (1 Form A type) 3-(2). Coil temperature rise (1 Form C type) 4-(1). Ambient temperature characteristics (1 Form A type) Contact carrying current: 3 A, 5 A Measured portion: Inside the coil Contact carrying current: 3 A, 5 A Measured portion: Inside the coil Tested sample: JQ1a-24V Contact carrying current: 3 A, 5 A 70 70 60 60 5 A at 50°C 5 A at 70°C 40 30 20 Coil applied voltage, %V 50 Temperature rise, °C Temperature rise, °C 5 A at 50°C 5 A at 70°C 50 3 A at 50°C 40 30 3 A at 70°C 20 3 A at 50°C 10 300 3A Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) 5A 200 5A 3A 100 3 A at 70°C 10 Pick-up voltage 0 100 110 120 130 140 0 150 160 100 110 Coil applied voltage, %V 120 130 140 0 150 160 20 40 Pick-up voltage with a hot-start condition of 100%V on the coil 60 80 100 Ambient temperature, °C Coil applied voltage, %V 4-(2). Ambient temperature characteristics (1 Form C type) Coil applied voltage, %V Tested sample: JQ1-24V Contact carrying current: 3 A, 5 A 300 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) 3A 200 5A 5A 100 Pick-up voltage with 3A a hot-start condition Pick-up voltage of 100%V on the coil 0 20 40 60 80 100 Ambient temperature, °C High capacity type 1-(1). Operate & release time (1 Form A type) 1-(2). Operate & release time (1 Form C type) Tested sample: JQ1aP-12V, 25 pcs. Tested sample: JQ1P-12V, 25 pcs. 2. Life curve Ambient temperature: room temperature 6 Operate time 4 Max. Min. Max. Min. 2 0 100 6 Operate time Max. Max. Min. Min. Release time 120 0 150 125V AC resistive load 10 4 2 Release time 80 8 Life, ×104 8 Operate & release time, ms Operate & release time, ms 100 Coil applied voltage, %V 80 100 120 250V AC resistive load 1 150 0 2 4 6 8 10 Contact current, A Coil applied voltage, %V 3-(2). Coil temperature rise (1 Form C type) 4-(1). Ambient temperature characteristics (1 Form A type) Contact carrying current: 5 A, 10 A Measured portion: Inside the coil Contact carrying current: 5 A, 10 A Measured portion: Inside the coil Tested sample: JQ1aP-24V Contact carrying current: 5 A, 10 A 70 70 60 60 Temperature rise, °C Temperature rise, °C 10 A at 50°C 50 40 10 A at 70°C 10 A at 50°C 30 20 10 A at 70°C 50 5 A at 50°C 40 30 5 A at 70°C 20 5 A at 50°C Coil applied voltage, %V 3-(1). Coil temperature rise (1 Form A type) 300 1 200 2 3 100 5 A at 70°C 10 10 Pick-up voltage 4 0 100 110 120 130 140 150 160 Coil applied voltage, %V 82 0 100 110 120 130 140 150 160 Coil applied voltage, %V 0 20 40 60 80 Ambient temperature, °C 100 JQ 4-(2). Ambient temperature characteristics (1 Form C type) Coil applied voltage, %V Tested sample: JQ1P-24V Contact carrying current: 5 A, 10 A 1 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F)(Carrying current: 5 A) 2 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F)(Carrying current: 10 A) 3 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 10A) 4 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5A) 300 1 200 2 3 100 Pick-up voltage 4 0 20 40 60 80 100 Ambient temperature, °C For Cautions for Use, see Relay Technical Information (Page 11 to 39). 83