High Voltage High Current Feed-Through Terminal Blocks The new High Voltage Generation of high current feedthrough terminal blocks is specially designed for the requirements of drive technology and power electronics. In addition to the already familiar simple assembly, the outstanding feature of these terminal blocks is a high nominal voltage of 1000 V. For the conductor cross section range up to 10 mm2, there are the horizontal feed-through terminal blocks, HDFK 10-HV and the vertical version, HDFKV 10-HV. The HDFKV 10-TWIN-HV with a conductor connection on both sides is used to loop through intermediate circuit voltages. In addition to this, the HV range is rounded off by the molded variant. The HDFK...-VP-HV terminal blocks are specially designed for the requirements of potted devices, such as filter modules, for example. They are an ideal supplement to the HDFK range for the cross section range of up to 10 mm2. The external parts of the molded high current feedthrough terminal blocks is identical to those of the standard HV versions. On the inside of the device, however, there is a sealing plate as well as a sponge rubber seal that prevents the molding compound from leaking out. The connection here is soldered. Phoenix Contact GmbH & Co. KG • 32823 Blomberg, Germany Phone +49 52 35 3-00 • Fax +49 52 35 3-4 12 00 • www.phoenixcontact.com High Current Feed-Through Terminal Blocks HDFK 10-HV (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.5-16 0.5-10 20-6 76 1000 u Technical data Type Order No. Pcs. Pkt. Feed-through terminal block, for 1 - 4 mm thick housing panels, with internal and external screw connection HDFK 10-HV 07 09 86 4 50 (1) Insertion bridge1), fully insul., fully insulated, divisible, fully insulated, EB 2-10 EB 3-10 EB 10-10 02 03 15 3 02 03 32 8 02 03 13 7 100 10 10 SZS 1,0 x 4,0 12 05 06 6 10 ZB 10:UNPRINTED 10 53 00 1 10 2-pos. 3-pos. 10-pos. (2) Screwdriver, for actuating the tension spring (3) Zack strip, 10-section, white Imax.: 70 A 70 A 70 A Dimensions Technical data in accordance with IEC/ DIN VDE Max. cross section with insertion bridge (solid/stranded) [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule without / with plastic sleeve [mm2] Multi-conductor connection (2 cond. with same cross section) Solid / Stranded [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Terminal sleeve: Thread / torque – / [Nm] Insulating material Inflammability class in acc. with UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 1 see dimensional drawing 10 / 10 6/3 III / I 0.5 - 10 / 0.5 - 10 0.5 - 4 / 0.5 - 4 0.5 - 2.5 0.5 - 6 11 B6 M 4 / 1.5 - 1.8 PA V0 600 / 65 / 24 - 6 600 / 65 / 22 - 6 ) Finger-safe protection is not guaranteeed when using the insertion bridge externally. Note: With the HDFK and HDFKV, the terminal space must be completely open when joining both terminal block halves. The HDFK 10-HV can also be connected if turned by 180°. 10,1 9,5 13,3 17,7 3,3 28,67 31,2 35 7,8 Phoenix Contact page 2 of 6 High Current Feed-Through Terminal Blocks HDFKV 10-HV (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.5-16 0.5-10 20-6 76 1000 Technical data Type Order No. Pcs. Pkt. Feed-through terminal block, for 1 - 4 mm thick housing panels, with internal and external screw connection HDFKV 10-HV 07 17 23 8 50 (1) Insertion bridge1), fully insul., fully insulated, divisible, fully insulated, EB 2-10 EB 3-10 EB 10-10 02 03 15 3 02 03 32 8 02 03 13 7 100 10 10 SZS 1,0 x 4,0 12 05 06 6 10 ZB 10:UNPRINTED 10 53 00 1 10 2-pos. 3-pos. 10-pos. (2) Screwdriver, for actuating the tension spring (3) Zack strip, 10-section, white Imax.: 70 A 70 A 70 A Dimensions Technical data in accordance with IEC/ DIN VDE Max. cross section with insertion bridge (solid/stranded) [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule without / with plastic sleeve [mm2] Multi-conductor connection (2 cond. with same cross section) Solid / Stranded [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Terminal sleeve: Thread / torque – / [Nm] Insulating material Inflammability class in acc. with UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL/CUL: [V] / [A] / AWG 1 see dimensional drawing 10 / 10 6/3 III / I 0.5 - 10 / 0.5 - 10 0.5 - 4 / 0.5 - 4 0.5 - 2.5 0.5 - 6 11 B6 M 4 / 1.5 - 1.8 PA V0 600 / 65 / 24 - 6 ) Finger-safe protection is not guaranteeed when using the insertion bridge externally. Note: With the HDFK and HDFKV, the terminal space must be completely open when joining both terminal block halves. 10,1 9,5 22,7 31,2 17,6 3,3 28,7 40,3 40,3 34,7 37,9 7,8 Phoenix Contact page 3 of 6 High Current Feed-Through Terminal Blocks HDFKV 10-TWIN-HV (IEC) [mm2] rigid solid flexible stranded AWG I [A] U [V] Connection data 0.5-16 0.5-10 20-6 76* 1000 * The max. load current must not be exceeded by the total current of all connected conductors. Technical data Type Order No. Pcs. Pkt. Feed-through terminal block, with internal and external screw connection, for 1 - 4 mm thick housing panels, external for vertical conductor connection HDFKV 10-TWIN-HV 07 17 24 1 50 (1) Insertion bridge1), fully insul., fully insulated, divisible, fully insulated, EB 2-10 EB 3-10 EB 10-10 02 03 15 3 02 03 32 8 02 03 13 7 100 10 10 SZS 1,0 x 4,0 12 05 06 6 10 ZB 10:UNPRINTED 10 53 00 1 10 2-pos. 3-pos. 10-pos. (2) Screwdriver, for actuating the tension spring (3) Zack strip, 10-section, white Imax.: 70 A 70 A 70 A Dimensions Technical data in accordance with IEC/ DIN VDE Max. cross section with insertion bridge (solid/stranded) [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule without / with plastic sleeve [mm2] Multi-conductor connection (2 cond. with same cross section) Solid / Stranded [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Terminal sleeve: Thread / torque – / [Nm] Insulating material Inflammability class in acc. with UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL/CUL: [V] / [A] / AWG 1 see dimensional drawing 10 / 10 6/3 III / I 0.5 - 10 / 0.5 - 10 0.5 - 4 / 0.5 - 4 0.5 - 2.5 0.5 - 6 11 B6 M 4 / 1.5 - 1.8 PA V0 600 / 65 / 24 - 6 ) Finger-safe protection is not guaranteeed when using the insertion bridge externally. Note: With the HDFK and HDFKV, the terminal space must be completely open when joining both terminal block halves. 1 0 ,1 2 8 ,7 3 ,1 4 5 ,4 3 6 9 ,5 1 9 3 1 ,2 4 5 ,4 2 2 ,7 3 7 ,9 7 ,8 Phoenix Contact page 4 of 6 High Current Feed-Through Terminal Blocks HDFK 10-VP-HV (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.5-16 0.5-10 20-6 76 1000 Technical data Type Order No. Pcs. Pkt. Molded feed-through terminal block, for 1 - 4 mm thick housing panels, with external screw connection, with solder connection and sealing plate inside HDFK 10-VP-HV 07 17 39 3 50 (1) Insertion bridge1), fully insul., fully insulated, divisible, fully insulated, EB 2-10 EB 3-10 EB 10-10 02 03 15 3 02 03 32 8 02 03 13 7 100 10 10 SZS 1,0 x 4,0 12 05 06 6 10 ZB 10:UNPRINTED 10 53 00 1 10 2-pos. 3-pos. 10-pos. (2) Screwdriver, for actuating the tension spring (3) Zack strip, 10-section, white Imax.: 70 A 70 A 70 A Dimensions Technical data in accordance with IEC/ DIN VDE Max. cross section with insertion bridge (solid/stranded) [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule without / with plastic sleeve [mm2] Multi-conductor connection (2 cond. with same cross section) Solid / Stranded [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Terminal sleeve: Thread / torque – / [Nm] Insulating material Inflammability class in acc. with UL 94 10 / 10 6/3 III / I 0.5 - 10 / 0.5 - 10 0.5 - 4 / 0.5 - 4 0.5 - 2.5 0.5 - 6 11 B6 M 4 / 1.5 - 1.8 PA V0 ) Finger-safe protection is not guaranteeed when using the insertion bridge externally. 10,1 58,8 9,5 14 31,2 17,2 3,3 35 31,2 1 see dimensional drawing 7,8 Phoenix Contact page 5 of 6 High Current Feed-Through Terminal Blocks HDFKV 10-VP-HV Connection data rigid solid flexible stranded AWG I [A] U [V] 0.5-16 0.5-10 20-6 76 1000 Technical data Type Order No. Pcs. Pkt. Molded Feed-through terminal block, for 1 - 4 mm thick housing panels, with external screw connection, with solder connection and sealing plate inside HDFKV 10-VP-HV 07 17 25 4 50 (1) Insertion bridge1), fully insul., fully insulated, divisible, fully insulated, EB 2-10 EB 3-10 EB 10-10 02 03 15 3 02 03 32 8 02 03 13 7 100 10 10 SZS 1,0 x 4,0 12 05 06 6 10 ZB 10:UNPRINTED 10 53 00 1 10 2-pos. 3-pos. 10-pos. (2) Screwdriver, for actuating the tension spring (3) Zack strip, 10-section, white Imax.: 70 A 70 A 70 A Dimensions Technical data in accordance with IEC/ DIN VDE Max. cross section with insertion bridge (solid/stranded) [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule without / with plastic sleeve [mm2] Multi-conductor connection (2 cond. with same cross section) Solid / Stranded [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Terminal sleeve: Thread / torque – / [Nm] Insulating material Inflammability class in acc. with UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL/CUL: [V] / [A] / AWG 10 / 10 6/3 III / I 0.5 - 10 / 0.5 - 10 0.5 - 4 / 0.5 - 4 0.5 - 2.5 0.5 - 6 11 B6 M 4 / 1.5 - 1.8 PA V0 600 / 65 / 24 - 6 ) Finger-safe protection is not guaranteeed when using the insertion bridge externally. 61,4 9,5 22,7 34,7 7,8 Phoenix Contact page 6 of 6 12 10,1 3,3 37,9 34,7 1 see dimensional drawing PHOENIX CONTACT 15.04.03 TNR: 5125870-01 http://www.phoenixcontact.com (IEC) [mm2]