SAMSUNG K4S64323LF-SN15

K4S64323LF-S(D)N/U/P
CMOS SDRAM
2Mx32
Mobile SDRAM
90FBGA
(VDD/VDDQ 2.5V/1.8V or 2.5V/2.5V)
Revision 1.5
December 2002
Rev. 1.5 Dec 2002
K4S64323LF-S(D)N/U/P
CMOS SDRAM
512K x 32Bit x 4 Banks SDRAM
FEATURES
GENERAL DESCRIPTION
•
•
•
•
Dynamic RAM organized as 4 x 524,288 words by 32 bits, fabricated with SAMSUNG′s high performance CMOS technology.
Synchronous design allows precise cycle control with the use of
•
•
•
•
•
•
•
2.5V Power Supply.
LVCMOS compatible with multiplexed address.
Four banks operation.
MRS cycle with address key programs.
-. CAS latency (1, 2 & 3).
-. Burst length (1, 2, 4, 8 & Full page).
-. Burst type (Sequential & Interleave).
All inputs are sampled at the positive going edge of the system
clock .
Burst read single-bit write operation.
DQM for masking.
Auto & self refresh.
64ms refresh period (4K cycle).
Extended temperature range (-25°C to 85 °C).
Industrial Temperature range (-40°C to 85°C) for low power.
90balls FBGA( -SXXX -Pb, -DXXX -Pb Free).
The K4S64323LF is 67,108,864 bits synchronous high data rate
system clock. I/O transactions are possible on every clock cycle.
Range of operating frequencies, programmable burst lengths and
programmable latencies allow the same device to be useful for a
variety of high bandwidth and high performance memory system
applications.
ORDERING INFORMATION
Part No.
Max Freq.
K4S64323LF-S(D)N/U/P75
Interface Package
133MHz(CL=3) *1
105MHz(CL=2)
K4S64323LF-S(D)N/U/P1H 105MHz(CL=2)
LVCMOS
K4S64323LF-S(D)N/U/P1L 105MHz(CL=3) *2
90FBGA
Pb
(Pb Free)
K4S64323LF-S(D)N/U/P15 66MHz(CL=2/3) *3
-S(D)N ; Low Power, Operating Temp : -25°C~85 °C.
-S(D)U ; Super Low Power, Operating Temp : -25 °C~85°C.
-S(D)P ; Low Power, Operating Temp : -40°C~85 °C.
FUNCTIONAL BLOCK DIAGRAM
Notes :
1. In case of 55MHz Frequency, CL1 can be supported.
2. In case of 40MHz Frequency, CL1 can be supported.
3. In case of 33MHz Frequency, CL1 can be supported.
I/O Control
Data Input Register
LWE
LDQM
Bank Select
512K x 32
512K x 32
512K x 32
Output Buffer
Sense AMP
Row Decoder
ADD
Row Buffer
Refresh Counter
DQi
Column Decoder
Col. Buffer
LCBR
LRAS
Address Register
CLK
512K x 32
Latency & Burst Length
LCKE
Programming Register
LRAS
LCBR
LWE
LCAS
LWCBR
LDQM
Timing Register
CLK
CKE
CS
RAS
CAS
WE
DQM
* Samsung Electronics reserves the right to
change products or specification without
notice.
Rev. 1.5 Dec 2002
K4S64323LF-S(D)N/U/P
CMOS SDRAM
90-Ball FBGA Package Dimension and Pin Configuration
< Bottom View*1 >
< Top View*2 >
E1
9
8
7
6
5
4
3
2
90Ball(6x15) CSP
1
1
2
3
7
8
9
B
A
DQ26
DQ24
V SS
VD D
DQ23
DQ21
C
B
DQ28
V DDQ
VSSQ
V DDQ
V SSQ
DQ19
D
C
VSSQ
DQ27
DQ25
DQ22
DQ20
VDDQ
e
A
D
D1
E
D
VSSQ
DQ29
DQ30
DQ17
DQ18
VDDQ
F
E
V DDQ
DQ31
NC
NC
DQ16
V SSQ
G
F
V SS
DQM3
A3
A2
DQM2
VD D
G
A4
A5
A6
A10
A0
A1
H
A7
A8
NC
NC
BA1
NC
H
J
K
D/2
L
M
J
CLK
CKE
A9
BA0
CS
RAS
K
DQM1
NC
NC
CAS
WE
DQM0
L
V DDQ
DQ8
V SS
VD D
DQ7
V SSQ
P
M
VSSQ
DQ10
DQ9
DQ6
DQ5
VDDQ
R
N
VSSQ
DQ12
DQ14
DQ1
DQ3
VDDQ
P
DQ11
V DDQ
VSSQ
V DDQ
V SSQ
DQ4
R
DQ13
DQ15
V SS
VD D
DQ0
DQ2
N
E
E/2
*2: Top View
A
A1
Substrate(4Layer)
b
*1: Bottom View
< Top View*2 >
#A1 Ball Origin Indicator
z
Pin Name
Pin Function
CLK
System Clock
CS
Chip Select
CKE
Clock Enable
A 0 ~ A10
Address
BA0 ~ BA 1
Bank Select Address
RAS
Row Address Strobe
CAS
Column Address Strobe
WE
Write Enable
DQM 0 ~ DQM 3
Data Input/Output Mask
SAMSUNG
Week
K4S64323LF-XXXX
DQ 0 ~ 31
Data Input/Output
V DD /VSS
Power Supply/Ground
V DDQ /VSSQ
Data Output Power/Ground
[Unit:mm]
Symbol
Min
Typ
Max
A
-
1.30
1.40
A1
0.30
0.35
0.40
E
-
11.00
-
E1
-
6.40
-
D
-
13.00
-
D1
-
11.20
-
e
-
0.80
-
b
0.40
0.45
0.50
z
-
-
0.10
Rev. 1.5 Dec 2002
K4S64323LF-S(D)N/U/P
CMOS SDRAM
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Value
Unit
Voltage on any pin relative to Vss
VIN , V OUT
-1.0 ~ 3.6
V
Voltage on V DD supply relative to Vss
V D D, VDDQ
-1.0 ~ 3.6
V
TSTG
-55 ~ +150
°C
Power dissipation
PD
1
W
Short circuit current
IOS
50
mA
Storage temperature
Notes :
Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS are exceeded.
Functional operation should be restricted to recommended operating condition.
Exposure to higher than recommended voltage for extended periods of time could affect device reliability.
DC OPERATING CONDITIONS
Recommended operating conditions (Voltage referenced to VSS = 0V, TA = -25 °C to 85 °C for Extended, -40°C to 85°C for Industrial)
Parameter
Symbol
Min
Typ
Max
Unit
VD D
2.3
2.5
2.7
V
V DDQ
1.65
-
2.7
V
Input logic high voltage
VI H
0.8 x V DDQ
-
V DDQ + 0.3
V
1
Input logic low voltage
VIL
-0.3
0
0.3
V
2
Output logic high voltage
VO H
V DDQ -0.2V
-
-
V
IO H = -0.1mA
Output logic low voltage
V OL
-
-
0.2
V
I OL = 0.1mA
ILI
-10
-
10
uA
3
Supply voltage
Input leakage current
Note
Notes :
1. VIH (max) = 3.0V AC.The overshoot voltage duration is ≤ 3ns.
2. VIL (min) = -2.0V AC. The undershoot voltage duration is ≤ 3ns.
3. Any input 0V ≤ V IN ≤ VDDQ .
Input leakage currents include Hi-Z output leakage for all bi-directional buffers with Tri-State outputs.
4. Dout is disabled, 0V ≤ V OUT ≤ V DDQ.
CAPACITANCE
(VDD = 2.5V, TA = 23°C, f = 1MHz, V REF =0.9V ± 50 mV)
Pin
Symbol
Min
Max
Unit
CCLK
-
4.0
pF
CIN
-
4.0
pF
Address(A0 ~ A10, BA 0 ~ BA 1 )
CADD
-
4.0
pF
D Q0 ~ DQ31
COUT
-
6.0
pF
Clock
RAS, CAS, WE, CS, CKE, DQM0 ~ DQM3
Note
Rev. 1.5 Dec 2002
K4S64323LF-S(D)N/U/P
CMOS SDRAM
DC CHARACTERISTICS
Recommended operating conditions (Voltage referenced to VSS = 0V, TA = -25°C to 85°C for Extended, -40 °C to 85 °C for Industrial)
Parameter
Symbol
Operating Current
(One Bank Active)
Precharge Standby Current
in power-down mode
ICC1
-1H
-1L
-15
70
70
65
60
CKE ≤ V IL (max), t CC = 10ns
0.5
ICC2 PS
CKE & CLK ≤ V IL (max), t CC = ∞
0.5
IC C 2N
CKE ≥ V IH (min), CS ≥ V I H(min), t CC = 10ns
Input signals are changed one time during 20ns
10
mA
mA
7
I CC3P
CKE ≤ V IL (max), t CC = 10ns
5
ICC3 PS
CKE & CLK ≤ V IL (max), t CC = ∞
5
IC C 3N
CKE ≥ V IH (min), CS ≥ V I H(min), t CC = 10ns
Input signals are changed one time during 20ns
20
mA
CKE ≥ V IH (min), CLK ≤ V IL (max), t CC = ∞
Input signals are stable
20
mA
ICC3 NS
1
mA
CKE ≥ V IH (min), CLK ≤ V IL (max), t CC = ∞
Input signals are stable
ICC2 NS
Active Standby Current
in non power-down mode
(One Bank Active)
Burst length = 1
tRC ≥ tR C(min)
IO = 0 mA
Unit Note
-75
I CC2P
Precharge Standby Current
in non power-down mode
Active Standby Current
in power-down mode
Version
Test Condition
mA
Operating Current
ICC4
IO = 0 mA ,Page burst
85
70
70
60
mA
1
Refresh Current
ICC5
tRC ≥ tRC (min)
115
110
100
80
mA
2
Self Refresh Current
ICC6
CKE ≤ 0.2V
-S(D)N/P
350
-S(D)U
230
uA
3
4
Notes :
1. Measured with outputs open.
2. Refresh period is 64ms.
3. K4S64323LF-S(D)N/P**
4. K4S64323LF-S(D)U**
5. Unless otherwise noted, input swing IeveI is CMOS(VIH /VIL =V DDQ /V SSQ).
Rev. 1.5 Dec 2002
K4S64323LF-S(D)N/U/P
AC OPERATING TEST CONDITIONS
CMOS SDRAM
(V DD = 2.5V ± 0.2V, TA = -25 °C to 85 °C for Extended, -40°C to 85 °C for Industrial)
Parameter
Value
Unit
0.9 x V DDQ / 0.2
V
0.5 x VDDQ
V
tr/tf = 1/1
ns
Output timing measurement reference level
0.5 x VDDQ
V
Output load condition
See Fig. 2
AC input levels (Vih/Vil)
Input timing measurement reference level
Input rise and fall time
VDDQ
Vtt=0.5 x VDDQ
500Ω
50Ω
VOH (DC) = V DDQ -0.2V, IO H = -0.1mA
Output
VOL (DC) = 0.2V, IOL = 0.1mA
Output
500Ω
Z0=50Ω
30pF
30pF
(Fig. 1) DC Output Load Circuit
(Fig. 2) AC Output Load Circuit
OPERATING AC PARAMETER(AC operating conditions unless otherwise noted)
Parameter
Version
Symbol
- 75
-1H
-1L
-15
Unit
Note
Row active to row active delay
tRRD (min)
15
19
19
30
ns
1
RAS to CAS delay
tRCD (min)
19
19
24
30
ns
1
tRP (min)
19
19
24
30
ns
1
tRAS (min)
45
50
60
60
ns
1
Row precharge time
Row active time
tRAS (max)
Row cycle time
t R C(min)
Last data in to row precharge
tR D L(min)
Last data in to Active delay
100
ns
1
2
CLK
2,3
tDAL (min)
tRDL + tRP
-
3
Last data in to new col. address delay
tC D L(min)
1
CLK
2
Last data in to burst stop
tBDL (min)
1
CLK
2
Col. address to col. address delay
tCCD (min)
1
CLK
4
ea
5
Number of valid output data
65
70
us
84
CAS latency=3
2
CAS latency=2
1
CAS latency=1
-
90
0
Notes :
1. The minimum number of clock cycles is determined by dividing the minimum time required with clock cycle time
and then rounding off to the next higher integer.
2. Minimum delay is required to complete write.
3. Minimum tRDL=2CLK and tDAL(=tRDL + tRP) is required to complete both of last data wite command(tRDL) and precharge
command(tRP). tRDL=1CLK can be supported only in the case under 100MHz with manual precharge mode.
4. All parts allow every cycle column address change.
5. In case of row precharge interrupt, auto precharge and read burst stop.
Rev. 1.5 Dec 2002
K4S64323LF-S(D)N/U/P
CMOS SDRAM
AC CHARACTERISTICS(AC operating conditions unless otherwise noted)
Parameter
- 75
Symbol
Min
CAS latency=3
CLK cycle time
CAS latency=2
tC C
9.5
tSAC
CAS latency=1
CAS latency=3
Output data hold time
CAS latency=2
tO H
CAS latency=1
Min
-1L
Max
9.5
1000
-
CAS latency=3
CAS latency=2
Max
7.5
CAS latency=1
CLK to valid output delay
-1H
9.5
Min
- 15
Max
9.5
1000
-
12
Min
Unit
Note
ns
1
ns
1,2
ns
2
Max
15
1000
25
15
1000
30
5.4
7
7
9
7
7
8
9
-
-
20
24
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
-
-
2.5
2.5
CLK high pulse width
tC H
2.5
3
3
3.5
ns
3
CLK low pulse width
tCL
2.5
3
3
3.5
ns
3
Input setup time
tSS
2.0
2.5
2.5
3.5
ns
3
Input hold time
t SH
1.0
1.5
1.5
2.0
ns
3
CLK to output in Low-Z
t SLZ
1
1
1
1
ns
2
CAS latency=3
CLK to output in Hi-Z
CAS latency=2
tSHZ
CAS latency=1
5.4
7
7
9
7
7
8
9
-
-
20
24
ns
Notes :
1. Parameters depend on programmed CAS latency.
2. If clock rising time is longer than 1ns, (tr/2-0.5)ns should be added to the parameter.
3. Assumed input rise and fall time (tr & tf) = 1ns.
If tr & tf is longer than 1ns, transient time compensation should be considered,
i.e., [(tr + tf)/2-1]ns should be added to the parameter.
Notes :
1. Samsung are not designed or manufactured for use in a device or system that is used under circumstance in which human life
is potentially at stake. Please contact to the memory marketing team in samsung electronics when considering the use of
a product contained herein for any specific purpose, such as medical, aerospace, nuclear, military, vehicular or undersea
repeater use.
Rev. 1.5 Dec 2002
K4S64323LF-S(D)N/U/P
CMOS SDRAM
SIMPLIFIED TRUTH TABLE (V=Valid, X=Don′t Care, H=Logic High, L=Logic Low)
COMMAND
Register
Mode Register Set
Auto Refresh
Refresh
Entry
Self
Refresh
Exit
CKEn-1
CKEn
CS
RAS
CAS
WE
DQM
H
X
L
L
L
L
X
OP CODE
L
L
L
H
X
X
X
X
H
H
L
L
H
H
H
H
X
X
X
X
L
L
H
H
X
V
X
L
H
L
H
X
V
L
H
Bank Active & Row Addr.
H
Read &
Column Address
Auto Precharge Disable
H
Write &
Column Address
Auto Precharge Disable
Auto Precharge Enable
Auto Precharge Enable
Burst Stop
Precharge
Bank Selection
X
L
H
L
L
X
H
X
L
H
H
L
X
H
X
L
L
H
L
X
Entry
H
L
Exit
L
H
Entry
H
L
Precharge Power Down Mode
Exit
A10 /AP
L
DQM
H
No Operation Command
H
H
H
X
X
X
L
V
V
V
X
X
X
X
H
X
X
X
L
H
H
H
H
X
X
X
L
V
V
V
X
X
H
X
X
X
L
H
H
H
X
V
A9 ~ A 0
Note
1, 2
3
3
3
3
Row Address
L
Column
Address
(A 0 ~ A7)
H
L
H
All Banks
Clock Suspend or
Active Power Down
BA0,1
Column
Address
(A 0 ~ A7)
H
X
V
L
X
H
4
4, 5
4
4, 5
6
X
X
X
X
X
X
V
X
X
X
7
Note :
1. OP Code : Operand Code
A 0 ~ A 10 & BA0 ~ BA 1 : Program keys. (@MRS)
2. MRS can be issued only at all banks precharge state.
A new command can be issued after 2 CLK cycles of MRS.
3. Auto refresh functions are the same as CBR refresh of DRAM.
The automatical precharge without row precharge command is meant by "Auto".
Auto/self refresh can be issued only at all banks precharge state.
4. BA0 ~ BA1 : Bank select addresses.
If both BA 0 and BA1 are "Low" at read, write, row active and precharge, bank A is selected.
If BA 0 is "Low" and BA 1 is "High" at read, write, row active and precharge, bank B is selected.
If BA 0 is "High" and BA1 is "Low" at read, write, row active and precharge, bank C is selected.
If both BA 0 and BA1 are "High" at read, write, row active and precharge, bank D is selected.
If A 10 /AP is "High" at row precharge, BA0 and BA 1 are ignored and all banks are selected.
5. During burst read or write with auto precharge, new read/write command can not be issued.
Another bank read/write command can be issued after the end of burst.
New row active of the associated bank can be issued at tRP after the end of burst.
6. Burst stop command is valid at every burst length.
7. DQM sampled at the positive going edge of CLK masks the data-in at that same CLK in write operation (Write DQM latency
is 0), but in read operation it makes the data-out Hi-Z state after 2 CLK cycles. (Read DQM latency is 2).
Rev. 1.5 Dec 2002