SENSORTECHNICS KTEM2100G4C5S

KTE2000...CS Series
OEM submersible level sensors
FEATURES
· 0...50 to 0...200 mbar
(approx. 0...1.67 to 0...6.70 ft H2O)
· Capacitive ceramic pressure cells
· For corrosive media
· 4...20 mA output
· High overpressure resistance
MEDIA COMPATIBILITY
Wetted materials:
Ceramic Al2O3, stainless steel 1Cr18Ni9Ti,
NBR, Viton, PE (PUR)
Housing:
protection class IP 68 (according to DIN EN 60529)
respectively NEMA 6P1
ELECTRICAL CONNECTION
SPECIFICATIONS6
Maximum ratings
Supply voltage2
Temperature limits
Storage
Operating
Compensated
Proof pressure3
12...30 V
-30...85 °C
-30...80 °C
-30...70 °C
10 x rated pressure
+Vs
Sensor
V
-Vs
Red
October 2008 / 653
12...30 V
Black
RL
GND
1/3
www.sensortechnics.com
KTE2000...CS Series
OEM submersible level sensors
INDIVIDUAL PERFORMANCE CHARACTERISTICS
Characteristics
Operating pressure
KTEM2050...
KTEM2100...
KTEM2200...
Min.
Typ.
0
0
0
Zero pressure offset
4.0
Full scale span
16.0
Thermal effects4
-20...70 °C
±0.015
-20...-30 °C
±0.02
Accuracy5
Max.
Unit
50
100
200
mbar
mA
%FSO/°C
±0.75
%FSO
Long term stability
±0.1
%FSO/year
Vibration (200 Hz/g)
±0.01
%FSO
LOAD LIMITATION2
Rmax =
Vs − 12 V
0.02 A
Specification notes:
1.
2.
3.
4.
5.
6.
The package is an all-sealed housing. For proper function the gage port is vented to the atmosphere through the connecting
cable. Thus the vent tube of the cable end must have access to the ambient pressure.
The minimum supply voltage is directly proportional to the load resistance seen by the transmitter.
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
All specifications shown are relative to 25°C.
Accuracy is the combined error from offset and span calibration, linearity, hysteresis and repeatability. Linearity is the
measured deviation based on a straight line. Hysteresis is the maximum output difference at any point within the operating
pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset and full scale
from nominal values.
The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
October 2008 / 653
2/3
www.sensortechnics.com
KTE2000...CS Series
OEM submersible level sensors
OUTLINE DRAWING
79.0
56.0
5 m cable incl. in delivery
(other cable lengths on request)
10.0
Ø 42.0
Vent tube
dimensions in mm
ORDERING INFORMATION
KTEM2
xxx
Pressure range
050:
0...50 mbar (approx. 1.67 ft H2O)
100:
0...100 mbar (approx. 3.35 ft H2O)
200:
0...200 mbar (approx. 6.70 ft H2O)
Pressure mode
G: gage pressure
G
4
C5S
Cable submersible
5: 5 m cable length
(other cable lengths on request)
output signal
4: 4...20 mA
Note: Other pressure ranges and calibrations (e.g. psi, inch H2O, cm H2O) are available on request.
Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
October 2008 / 653
3/3
www.sensortechnics.com