SENSORTECHNICS 432LP10D-PCB

110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
FEATURES
· 1 to 50 mbar, 1 to 30 "H2O
gage or differential pressure
(custom calibrations available)
· 1...6 V or 4...20 mA output
· Internal supply regulation
· Precision temperature compensated
and calibrated
· Special calibrations for small volumes
on request
SERVICE
Scale:
Non-corrosive, non-ionic working fluids
such as dry air and dry gases.
1 cm
1 inch
ELECTRICAL CONNECTION
SPECIFICATIONS
Maximum ratings
1...6 V output version
Supply voltage
110L...-PCB
430L...-PCB1
Maximum load current (110L...-PCB only)
source
sink
Temperature limits
Storage
Operating
Compensated
Lead temperature(4 sec soldering)
Humidity limits (pressure inlets only)
+Vs
12...24 V
12...36 V
20 mA
10 mA
12 to 24 V
110L...-PCB
Vout
V
-Vs
-25 to 85°C
-10 to 70°C
0 to 50°C
4...20 mA output version
300°C
+Vs
0 - 80 %RH
430L...-PCB
-Vs
January 2007 / 006
12 to 36 V
V
RL
GND
1/6
www.sensortechnics.com
110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
1...6 V output version (unless otherwise noted VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Operating
pressure3
Characteristics
Min.
differential
devices
0
0
0
0
0
-1
-2
-5
-10
-25
-50
0
0
0
0
0
pressure/
vacuum
devices3
differential
devices
pressure/
vacuum
devices3
Zero pressure offset4
Full scale span5
112LP02D-PCB
112LP05D-PCB
112LP10D-PCB
112LP25D-PCB
112LP50D-PCB
113LP01D-PCB
113LP02D-PCB
113LP05D-PCB
113LP10D-PCB
113LP25D-PCB
113LP50D-PCB
112LU01D-PCB
112LU02D-PCB
112LU05D-PCB
112LU10D-PCB
112LU20D-PCB
112LU30D-PCB
113LU01D-PCB
113LU02D-PCB
113LU05D-PCB
113LU10D-PCB
113LU20D-PCB
113LU30D-PCB
112L...-PCB
113L...-PCB
112L...-PCB
113L...-PCB
Full scale output
Output at lowest specified pressure
113L...-PCB
Thermal effects
Offset
113LP01D-PCB
(0 to 50°C)6
11...LP02D-PCB
11...LU01D-PCB
all other devices
Span
113LP01D-PCB
11...LP02D-PCB
11...LU01D-PCB
all other devices
Non-linearity and hysteresis (BSL)7
Long term stability8
Response time (10 to 90 %)
Position sensitivity
all 1 and 2 mbar devices
all other devices
Current consumption
Power supply
Offset
rejection
Span
2/6
-1
-2
-5
-10
-20
-30
0.95
3.4
4.9
2.4
Typ.
1.0
3.5
5.0
2.5
6.0
1.0
±0.08
±0.04
±0.04
±0.02
±0.08
±0.04
±0.04
±0.02
±0.1
±0.5
1
0.5
0.1
4.2
0.05
0.05
Max.
2
5
10
25
50
1
2
5
10
25
50
1
2
5
10
20
30
1
2
5
10
20
30
1.05
3.6
5.1
2.6
±0.20
±0.10
±0.10
±0.05
±0.20
±0.10
±0.10
±0.04
±0.25
Proof
Common mode
pressure2
pressure
200
200
200
300
300
200
200
200
200
300
300
80
120
120
240
240
240
80
120
120
240
240
240
300
300
300
600
600
300
300
300
300
600
600
160
240
240
360
360
360
160
240
240
360
360
360
Unit
mbar
"H2O
V
%FSO/°C
%FSO
ms
%FSO/g
mA
%FSO/V
January 2007 / 006
www.sensortechnics.com
110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
4...20 mA output version (unless otherwise noted VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Operating
pressure3
differential
devices
pressure/
vacuum
devices3
differential
devices
pressure/
vacuum
devices3
Zero pressure offset4
Full scale span5
432LP01D-PCB
432LP02D-PCB
432LP05D-PCB
432LP10D-PCB
432LP25D-PCB
432LP50D-PCB
433LP01D-PCB
433LP02D-PCB
433LP05D-PCB
433LP10D-PCB
433LP25D-PCB
433LP50D-PCB
432LU01D-PCB
432LU02D-PCB
432LU05D-PCB
432LU10D-PCB
432LU20D-PCB
432LU30D-PCB
433LU01D-PCB
433LU02D-PCB
433LU05D-PCB
433LU10D-PCB
433LU20D-PCB
433LU30D-PCB
432L...-PCB
433L...-PCB
432L...-PCB
433L...-PCB
Full scale output
Output at lowest specified pressure
433L...-PCB
Thermal effects
Offset
(0 to 50°C)6
43...LP01D-PCB
43...LP02D-PCB
43...LU01D-PCB
all other devices
Span
43...LP01D-PCB
43...LP02D-PCB
43...LU01D-PCB
all other devices
Non-linearity and hysteresis (BSL)7
Long term stability8
Response time (10 to 90 %)
Position sensitivity
all 1 and 2 mbar devices
all 1 "H2O devices
all other devices
Current consumption (IL = 20 mA)
Power supply
Offset
rejection
Span
January 2007 / 006
Min.
Typ.
0
0
0
0
0
0
-1
-2
-5
-10
-25
-50
0
0
0
0
0
-1
-2
-5
-10
-20
-30
3.9
11.9
15.8
7.9
4.0
12.0
16.0
8.0
20.0
4.0
±0.08
±0.04
±0.04
±0.02
±0.08
±0.04
±0.04
±0.02
0.1
±0.2
1
0.5
0.5
0.1
4.2
0.05
0.05
Max.
1
2
5
10
25
50
1
2
5
10
25
50
1
2
5
10
20
30
1
2
5
10
20
30
4.1
12.1
16.2
8.1
±0.20
±0.10
±0.10
±0.05
±0.20
±0.10
±0.10
±0.04
0.25
Proof
Common mode
pressure2
pressure
200
200
200
200
300
300
200
200
200
200
300
300
80
120
120
240
240
240
80
120
120
240
240
240
300
300
300
300
600
600
300
300
300
300
600
600
160
240
240
360
360
360
160
240
240
360
360
360
Unit
mbar
"H2O
mA
%FSO/°C
%FSO
ms
%FSO/g
mA
%FSO/V
3/6
www.sensortechnics.com
110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
Specification notes:
1.
The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
The output signal is proportional to the pressure applied to port B, relative to port A, e.g. the output signal increases when
vacuum is applied to port A relative to port B.
Calibrated after minimum 3 minutes warm-up time.
Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset.
Thermal effects tested and guaranteed from 0 - 50°C relative to 25°C. All specifications shown are relative to 25°C.
Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full-scale pressure.
Change in output after one year or 1 million pressure cycles.
2.
3.
4.
5.
6.
7.
8.
OUTPUT CHARACTERISTICS
1...6 V output versions
Differential devices
112L...-PCB
1...6 V output versions
Pressure/vacuum devices
113L...-PCB
6
6
Vout
5
V
4
Vout
5
V
4
3
3
2
2
1
1
0
20
40 60 80 100
% full scale pressure
4...20 mA output versions
Differential devices
432L...-PCB
0
-100
20
Iout
16
mA
8
8
4
4
4/6
-50
0
50
100
% full scale pressure
4...20 mA output versions
Pressure/vacuum devices
433L...-PCB
20
Iout
16
mA
12
0
3.5 V
12
20
40 60 80 100
% full scale pressure
0
-100
-50
0
50
100
% full scale pressure
January 2007 / 006
www.sensortechnics.com
110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
LOAD LIMITATION
4...20 mA output versions
1200
Ohm
1000
800
600
operating
range
400
200
0
10
20
30 V
Vsupply
OUTLINE DRAWING
30.5
30.0
port A
2 x 5.08 typ.
9.1
3 terminals
0.56 diam.
4.8
diam.
10.7
52.4
59.8
18.3
14.0
22.7
3
port B
(high pressure port)
3.5 diam.
2 x mounting holes
NOM 6.0
1
2
3
12.6
mass: 20 g
dimensions in mm
PIN CONNECTION:
Pin
1
2
3
January 2007 / 006
Connection
1 - 6 V version
4 - 20 mA version
+Vs
-Vs
Vout
NC
-Vs
+Vs
5/6
www.sensortechnics.com
110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
ORDERING INFORMATION
Operating pressure
Differential/gage devices
Pressure/vacuum devices
Differential/gage devices
Pressure/vacuum devices
Part number
1...6 V output
4...20 mA output
0 - 1 mbar
---
432LP01D-PCB
0 - 2 mbar
112LP02D-PCB
432LP02D-PCB
0 - 5 mbar
112LP05D-PCB
432LP05D-PCB
0 - 10 mbar
112LP10D-PCB
432LP10D-PCB
0 - 25 mbar
112LP25D-PCB
432LP25D-PCB
0 - 50 mbar
112LP50D-PCB
432LP50D-PCB
0 ±1 mbar
113LP01D-PCB
433LP01D-PCB
0 ±2 mbar
113LP02D-PCB
433LP02D-PCB
0 ±5 mbar
113LP05D-PCB
433LP05D-PCB
0 ±10 mbar
113LP10D-PCB
433LP10D-PCB
0 ±25 mbar
113LP25D-PCB
433LP25D-PCB
0 ±50 mbar
113LP50D-PCB
433LP50D-PCB
0 - 1"H2O
112LU01D-PCB
432LU01D-PCB
0 - 2"H2O
112LU02D-PCB
432LU02D-PCB
0 - 5"H2O
112LU05D-PCB
432LU05D-PCB
0 - 10"H2O
112LU10D-PCB
432LU10D-PCB
0 - 20"H2O
112LU20D-PCB
432LU20D-PCB
0 - 30"H2O
112LU30D-PCB
432LU30D-PCB
0 ± 1"H2O
113LU01D-PCB
433LU01D-PCB
0 ± 2"H2O
113LU02D-PCB
433LU02D-PCB
0 ± 5"H2O
113LU05D-PCB
433LU05D-PCB
0 ± 10"H2O
113LU10D-PCB
433LU10D-PCB
0 ± 20"H2O
113LU20D-PCB
433LU20D-PCB
0 ± 30"H2O
113LU30D-PCB
433LU30D-PCB
Custom calibrations available
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
6/6
January 2007 / 006
www.sensortechnics.com