110L...-PCB / 430L...-PCB Series Signal conditioned precision pressure transducers FEATURES · 1 to 50 mbar, 1 to 30 "H2O gage or differential pressure (custom calibrations available) · 1...6 V or 4...20 mA output · Internal supply regulation · Precision temperature compensated and calibrated · Special calibrations for small volumes on request SERVICE Scale: Non-corrosive, non-ionic working fluids such as dry air and dry gases. 1 cm 1 inch ELECTRICAL CONNECTION SPECIFICATIONS Maximum ratings 1...6 V output version Supply voltage 110L...-PCB 430L...-PCB1 Maximum load current (110L...-PCB only) source sink Temperature limits Storage Operating Compensated Lead temperature(4 sec soldering) Humidity limits (pressure inlets only) +Vs 12...24 V 12...36 V 20 mA 10 mA 12 to 24 V 110L...-PCB Vout V -Vs -25 to 85°C -10 to 70°C 0 to 50°C 4...20 mA output version 300°C +Vs 0 - 80 %RH 430L...-PCB -Vs January 2007 / 006 12 to 36 V V RL GND 1/6 www.sensortechnics.com 110L...-PCB / 430L...-PCB Series Signal conditioned precision pressure transducers PERFORMANCE CHARACTERISTICS 1...6 V output version (unless otherwise noted VS = 15 V, RL > 100 kΩ, tamb = 25°C) Operating pressure3 Characteristics Min. differential devices 0 0 0 0 0 -1 -2 -5 -10 -25 -50 0 0 0 0 0 pressure/ vacuum devices3 differential devices pressure/ vacuum devices3 Zero pressure offset4 Full scale span5 112LP02D-PCB 112LP05D-PCB 112LP10D-PCB 112LP25D-PCB 112LP50D-PCB 113LP01D-PCB 113LP02D-PCB 113LP05D-PCB 113LP10D-PCB 113LP25D-PCB 113LP50D-PCB 112LU01D-PCB 112LU02D-PCB 112LU05D-PCB 112LU10D-PCB 112LU20D-PCB 112LU30D-PCB 113LU01D-PCB 113LU02D-PCB 113LU05D-PCB 113LU10D-PCB 113LU20D-PCB 113LU30D-PCB 112L...-PCB 113L...-PCB 112L...-PCB 113L...-PCB Full scale output Output at lowest specified pressure 113L...-PCB Thermal effects Offset 113LP01D-PCB (0 to 50°C)6 11...LP02D-PCB 11...LU01D-PCB all other devices Span 113LP01D-PCB 11...LP02D-PCB 11...LU01D-PCB all other devices Non-linearity and hysteresis (BSL)7 Long term stability8 Response time (10 to 90 %) Position sensitivity all 1 and 2 mbar devices all other devices Current consumption Power supply Offset rejection Span 2/6 -1 -2 -5 -10 -20 -30 0.95 3.4 4.9 2.4 Typ. 1.0 3.5 5.0 2.5 6.0 1.0 ±0.08 ±0.04 ±0.04 ±0.02 ±0.08 ±0.04 ±0.04 ±0.02 ±0.1 ±0.5 1 0.5 0.1 4.2 0.05 0.05 Max. 2 5 10 25 50 1 2 5 10 25 50 1 2 5 10 20 30 1 2 5 10 20 30 1.05 3.6 5.1 2.6 ±0.20 ±0.10 ±0.10 ±0.05 ±0.20 ±0.10 ±0.10 ±0.04 ±0.25 Proof Common mode pressure2 pressure 200 200 200 300 300 200 200 200 200 300 300 80 120 120 240 240 240 80 120 120 240 240 240 300 300 300 600 600 300 300 300 300 600 600 160 240 240 360 360 360 160 240 240 360 360 360 Unit mbar "H2O V %FSO/°C %FSO ms %FSO/g mA %FSO/V January 2007 / 006 www.sensortechnics.com 110L...-PCB / 430L...-PCB Series Signal conditioned precision pressure transducers PERFORMANCE CHARACTERISTICS 4...20 mA output version (unless otherwise noted VS = 15 V, RL = 100 Ω, tamb = 25°C) Characteristics Operating pressure3 differential devices pressure/ vacuum devices3 differential devices pressure/ vacuum devices3 Zero pressure offset4 Full scale span5 432LP01D-PCB 432LP02D-PCB 432LP05D-PCB 432LP10D-PCB 432LP25D-PCB 432LP50D-PCB 433LP01D-PCB 433LP02D-PCB 433LP05D-PCB 433LP10D-PCB 433LP25D-PCB 433LP50D-PCB 432LU01D-PCB 432LU02D-PCB 432LU05D-PCB 432LU10D-PCB 432LU20D-PCB 432LU30D-PCB 433LU01D-PCB 433LU02D-PCB 433LU05D-PCB 433LU10D-PCB 433LU20D-PCB 433LU30D-PCB 432L...-PCB 433L...-PCB 432L...-PCB 433L...-PCB Full scale output Output at lowest specified pressure 433L...-PCB Thermal effects Offset (0 to 50°C)6 43...LP01D-PCB 43...LP02D-PCB 43...LU01D-PCB all other devices Span 43...LP01D-PCB 43...LP02D-PCB 43...LU01D-PCB all other devices Non-linearity and hysteresis (BSL)7 Long term stability8 Response time (10 to 90 %) Position sensitivity all 1 and 2 mbar devices all 1 "H2O devices all other devices Current consumption (IL = 20 mA) Power supply Offset rejection Span January 2007 / 006 Min. Typ. 0 0 0 0 0 0 -1 -2 -5 -10 -25 -50 0 0 0 0 0 -1 -2 -5 -10 -20 -30 3.9 11.9 15.8 7.9 4.0 12.0 16.0 8.0 20.0 4.0 ±0.08 ±0.04 ±0.04 ±0.02 ±0.08 ±0.04 ±0.04 ±0.02 0.1 ±0.2 1 0.5 0.5 0.1 4.2 0.05 0.05 Max. 1 2 5 10 25 50 1 2 5 10 25 50 1 2 5 10 20 30 1 2 5 10 20 30 4.1 12.1 16.2 8.1 ±0.20 ±0.10 ±0.10 ±0.05 ±0.20 ±0.10 ±0.10 ±0.04 0.25 Proof Common mode pressure2 pressure 200 200 200 200 300 300 200 200 200 200 300 300 80 120 120 240 240 240 80 120 120 240 240 240 300 300 300 300 600 600 300 300 300 300 600 600 160 240 240 360 360 360 160 240 240 360 360 360 Unit mbar "H2O mA %FSO/°C %FSO ms %FSO/g mA %FSO/V 3/6 www.sensortechnics.com 110L...-PCB / 430L...-PCB Series Signal conditioned precision pressure transducers Specification notes: 1. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. The output signal is proportional to the pressure applied to port B, relative to port A, e.g. the output signal increases when vacuum is applied to port A relative to port B. Calibrated after minimum 3 minutes warm-up time. Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset. Thermal effects tested and guaranteed from 0 - 50°C relative to 25°C. All specifications shown are relative to 25°C. Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full-scale pressure. Change in output after one year or 1 million pressure cycles. 2. 3. 4. 5. 6. 7. 8. OUTPUT CHARACTERISTICS 1...6 V output versions Differential devices 112L...-PCB 1...6 V output versions Pressure/vacuum devices 113L...-PCB 6 6 Vout 5 V 4 Vout 5 V 4 3 3 2 2 1 1 0 20 40 60 80 100 % full scale pressure 4...20 mA output versions Differential devices 432L...-PCB 0 -100 20 Iout 16 mA 8 8 4 4 4/6 -50 0 50 100 % full scale pressure 4...20 mA output versions Pressure/vacuum devices 433L...-PCB 20 Iout 16 mA 12 0 3.5 V 12 20 40 60 80 100 % full scale pressure 0 -100 -50 0 50 100 % full scale pressure January 2007 / 006 www.sensortechnics.com 110L...-PCB / 430L...-PCB Series Signal conditioned precision pressure transducers LOAD LIMITATION 4...20 mA output versions 1200 Ohm 1000 800 600 operating range 400 200 0 10 20 30 V Vsupply OUTLINE DRAWING 30.5 30.0 port A 2 x 5.08 typ. 9.1 3 terminals 0.56 diam. 4.8 diam. 10.7 52.4 59.8 18.3 14.0 22.7 3 port B (high pressure port) 3.5 diam. 2 x mounting holes NOM 6.0 1 2 3 12.6 mass: 20 g dimensions in mm PIN CONNECTION: Pin 1 2 3 January 2007 / 006 Connection 1 - 6 V version 4 - 20 mA version +Vs -Vs Vout NC -Vs +Vs 5/6 www.sensortechnics.com 110L...-PCB / 430L...-PCB Series Signal conditioned precision pressure transducers ORDERING INFORMATION Operating pressure Differential/gage devices Pressure/vacuum devices Differential/gage devices Pressure/vacuum devices Part number 1...6 V output 4...20 mA output 0 - 1 mbar --- 432LP01D-PCB 0 - 2 mbar 112LP02D-PCB 432LP02D-PCB 0 - 5 mbar 112LP05D-PCB 432LP05D-PCB 0 - 10 mbar 112LP10D-PCB 432LP10D-PCB 0 - 25 mbar 112LP25D-PCB 432LP25D-PCB 0 - 50 mbar 112LP50D-PCB 432LP50D-PCB 0 ±1 mbar 113LP01D-PCB 433LP01D-PCB 0 ±2 mbar 113LP02D-PCB 433LP02D-PCB 0 ±5 mbar 113LP05D-PCB 433LP05D-PCB 0 ±10 mbar 113LP10D-PCB 433LP10D-PCB 0 ±25 mbar 113LP25D-PCB 433LP25D-PCB 0 ±50 mbar 113LP50D-PCB 433LP50D-PCB 0 - 1"H2O 112LU01D-PCB 432LU01D-PCB 0 - 2"H2O 112LU02D-PCB 432LU02D-PCB 0 - 5"H2O 112LU05D-PCB 432LU05D-PCB 0 - 10"H2O 112LU10D-PCB 432LU10D-PCB 0 - 20"H2O 112LU20D-PCB 432LU20D-PCB 0 - 30"H2O 112LU30D-PCB 432LU30D-PCB 0 ± 1"H2O 113LU01D-PCB 433LU01D-PCB 0 ± 2"H2O 113LU02D-PCB 433LU02D-PCB 0 ± 5"H2O 113LU05D-PCB 433LU05D-PCB 0 ± 10"H2O 113LU10D-PCB 433LU10D-PCB 0 ± 20"H2O 113LU20D-PCB 433LU20D-PCB 0 ± 30"H2O 113LU30D-PCB 433LU30D-PCB Custom calibrations available Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. 6/6 January 2007 / 006 www.sensortechnics.com