POWER LINE CHOKE (DRUM CORE STYLE) Applications Electrical Specifications at 25OC Parameter Min. Typ. Max. Units Inductance 24 30 36 µH Filters Power Supplies 5.2 A SCR and Triac Controls IMAX 1 DCR Power Amplifiers Speaker Crossover Networks 21 mΩ .036 (0.914) inches (mm) RFI Suppression Lead Diameter Test Conditions: Inductance tested at 100 mVRMS and 1 kHz 1. Current for 10% drop in Inductance PHYSICAL DIMENSIONS D C Dim. B G F E A B C D E F G inches 0.560 0.810 0.187 0.126 0.500 0.750 0.062 High Saturation Pre-Tinned Leads Center hole for mechanical mounting A Leads are .036 (#19 AWG) RHOMBUS P/N: L-12206 CUST P/N: DATE: 01/10/02 Rhombus Industries Inc. Transformers & Magnetic Products NAME: SHEET: 1 OF 1 15801 Chemical Lane, Huntington Beach, CA 92649 Phone: (714) 898-0960 FAX: (714) 896-0971 www.rhombus-ind.com