LINKCOM LAN1826-50

LAN1826-50
10/100BASE-Tx Magnetics Module
Meets IEEE 802.3 standard
RoHS Compliant
Single port configuration
Design for 100base-Tx transmission over UTP-5 cable
Operating Temperature: -40℃~+85℃
Electrical Specification @25℃
OCL:
Hi-POT :
350uH Min. @100KHz/0.1V with 8mA DC Bias
1500Vrms.
Turn Ratio:
D.C.R:
Insertion Loss:
Return Loss:
1CT:1CT±3%
0.9ohm Max.
0.1-100MHz : -1.0dB Max.
60MHz
-14dB Typ.
50MHz
-37dB Typ.
60MHz
-40dB Typ.
30MHz
-20dB Typ.
30MHz
-42dB Typ.
30MHz
-45dB Typ.
D.C.M.R. :
Cross Talk :
Dimensions
80MHz
-12dB Typ.
100MHz
-32dB Typ.
100MHz
-35dB Typ.
Schematic
A
12.95MAX
0.46
8.89
TD+ 1
1.9
C
6.9
LAN1826
6.86 10.67
9.4 B
DATE CODE G
1.27
0.64
D
15 TXCT
TD- 3
14 TX-
1.27
0.25±0.10
0°~8°
RCT 7
0.25±0.13
0.89
RD- 8
Units: mm
Unless otherwise specified, all tolerances are ±0.25
Rev.A
16 TX+
TCT 2
RD+ 6
6.35 MAX
1:1
1:1
11 RX+
10 RXCT
9 RX-