NSC LM1042

LM1042 Fluid Level Detector
General Description
Features
The LM1042 uses the thermal-resistive probe technique to
measure the level of non-flammable fluids. An output is provided proportional to fluid level and single shot or repeating
measurements may be made. All supervisory requirements
to control the thermal-resistive probe, including short and
open circuit probe detection, are incorporated within the device. A second linear input for alternative sensor signals
may also be selected.
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Selectable thermal-resistance or linear probe inputs
Control circuitry for thermal-resistive probe
Single-shot or repeating measurements
Switch on reset and delay to avoid transients
Output amplifier with 10 mA source and sink capability
Short or open probe detection
a 50V transient protection on supply and control input
7.5V to 18V supply range
Internally regulated supply
b 40§ C to a 80§ C operation
Block Diagram
TL/H/8709 – 1
C1995 National Semiconductor Corporation
TL/H/8709
RRD-B30M115/Printed in U. S. A.
LM1042 Fluid Level Detector
February 1995
Absolute Maximum Ratings
Output Current Pin 11 (source)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales
Office/Distributors for availability and specifications.
Supply Voltage VCC
g 10 mA
Operating Temperature Range
32V
32V
Voltage at Pin 8
Positive Peak Voltage (Pins 6, 8, 3) (Note 1)
10 ms 2A
Output Current Pin 4, (I4)(sink)
25 mA
Output Current Pin 16
b 40§ C to a 80§ C
Storage Temperature Range
Lead Temperature (Soldering 10 sec.)
Package Power Dissipation
TA e 25§ C (Note 8)
Device Power Dissipation
50V
10 mA
b 55§ C to a 150§ C
260§ C
1.8W
0.9W
Electrical Characteristics
VCC e 13V, TA within operating range except where stated otherwise. CT e 22 mF, RT e 12k
Symbol
Parameter
Tested Limits
(Note 2)
Conditions
Min
VCC
Supply Voltage
IS
Supply Current
VREG
Regulated Voltage
Pins 15 and 11 connected
Stability Over VCC Range
Referred to value at
VCC e 13V (Note 4)
V6 – V3
T1
7.5
Max
Min
Typ
18
7.5
13
5.7
18
V
mA
2.15
(Note 4)
Ramp Timing
See Figure 5
5.65
6.2
V
g 0.5
%
2.40
V
g 0.8
%
31
42
ms
16
ms
1.75
2.1
s
g5
%
15.0
kX
5.9
g 0.5
Probe Current
Reference Voltage
Probe Current Regulation
Over VCC Range
6.15
2.35
2.10
2.25
g 0.5
20
37
15
1.4
2.1
1.4
3
T4 – T1
Ramp Timing
TSTAB
Ramp Timing Stability
RT
Ramp Resistor Range
V8
Start Input Logic High Level
V8
Start Input Logic Low Level
I8
Start Input Current
I8
Start Input Current
V8 e 0V
V16
Maximum Output Voltage
RL e 600X from
Pin 16 to VREG
Minimum Output Voltage
PROBE 1
Probe 1 Gain
Non-linearity of G1
OS1
Pin 1 Offset
G2
PROBE 2
Probe 2 Gain
Non-linearity of G2
OS7
Pin 7 Offset
R7
Input impedance
Over VCC Range
a5
3
15
1.7
V8 e VCC
3
1.7
V
0.5
0.5
V
100
100
nA
300
nA
300
VREGb0.3
Pin 1 80 mV to 520 mV
(Notes 6, 7)
Pin 1 80 mV to 520 mV
(Note 7)
Units
Max
35
35
T2 – T1
G1
Design Limits
(Note 3)
VREGb0.3
V
0.5
0.2
9.9
10.4
10.15
b1
a1
b2
(Note 7)
0
0.6
V
2
%
g5
Pin 7 240 mV to 1.562V
(Note 7)
Pin 7 240 mV to 1.562V
(Note 7)
(Note 7)
2
3.31
3.49
b1
a1
mV
3.4
b2
0.2
2
%
g5
mV
5
MX
Electrical Characteristics
VCC e 13V, TA within operating range except where stated otherwise. CT e 22 mF, RT e 12k (Continued)
Symbol
Parameter
Conditions
V1
Probe 1 Input
Voltage Range
VCC e 9V to 18V
VCC e 7.5V, I4 k 2.5 mA
(VREG e 6.0V)
V5
Probe 1 Open
Circuit Threshold
At Pin 5
V5
Probe 1 Short
Circuit Threshold
I14
Pin 14 Input
Leakage Current
Pin 14 e 4V
I1
Pin 1 Input
Leakage Current
Pin 1 e 300 mV
TR
Repeat Period
CR e 22 mF (Note 5)
CR Discharge Time
CR e 22 mF
Tested Limits
(Note 2)
Design Limits
(Note 3)
Min
Max
Min
1
5
1
1
Typ
Units
Max
5
3.5
VREGb0.7 VREGb0.5 VREGb0.85 VREGb0.6 VREGb0.35
0.5
0.7
b 2.0
2.0
b 5.0
5.0
12
28
0.35
9.1
0.6
V
V
V
0.85
V
2.0
nA
1.5
5.0
nA
17
36
s
135
ms
CM
Memory Capacitor Value
70
0.47
mF
C1
Input Capacitor Value
0.47
mF
Sensitivity fo Electrostatic DischargeÐ
Pins 7, 10, 13, and 14 will withstand greater than 1500V when tested using 100 pF and 1500X in accordance with National Semiconductor standard ESD test
procedures.
All other pins will withstand in excess of 2 kV.
Note 1: Test circuit for over voltage capability at pins 3, 6, 8.
TL/H/8709 – 2
Note 2: Guaranteed and 100% production tested at 25§ C. These limits are used to calculate outgoing quality levels.
Note 3: Limits guardbanded to include parametric variations. TA e b 40§ C to a 80§ C and from VCC e 7.5V to 18V. These limits are not used to calculate AOQL
figures.
Note 4: Variations over temperature range are not production tested.
Note 5: Time for first repeat period, see Figure 6 .
Note 6: Probe 1 amplifier tests are measured with pin 12 ramp voltage held between the T3 and T4 conditions (pin 12 & 1.1V) having previously been held above
4.1V to simulate ramp action. See Figure 5.
Note 7: When measuring gain separate ground wire sensing is required at pin 2 to ensure sufficiently accurate results.
Linearity is defined as the difference between the predicted value of VB (VB*) and the measured value.
Note 8: Above TA e 25§ C derate with ijA e 70§ C/W.
VC b VA
For probe 1 and probe 2ÐGain (G) e
Vc b Va
Input offset e
Linearity e
Ð
ÐG
VC
b Vc
V B*
b1
VB
(
(
c 100%
VB* e VA a G(Vb b Va)
TL/H/8709 – 15
3
Typical Performance Characteristics
Supply Current vs
Supply Voltage
Regulated Voltage vs
Supply Voltage
Output Voltage vs
Pin 7 Voltage
Probe Reference V vs
Supply Voltage
Output Voltage vs
Pin 14 Voltage
TL/H/8709 – 3
Pin Function Description
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10 A resistor may be connected to ground to vary the
gain of the probe 2 input amplifier. Nominal gain
when open circuit is 1.2 and when shorted to ground
3.4. DC conditions may be adjusted by means of a
resistor divider network to VREG and ground.
Pin 11 Regulated voltage output. Requires to be connected
to pin 15 to complete the supply regulator control
loop.
Pin 12 The capacitor connected from this pin to ground
sets the timing cycle for probe 1 measurements.
Pin 13 The resistor connected between this pin and ground
defines the charging current at pin 12. Typically 12k,
the value should be within the range 3k to 15k.
Pin 14 A low leakage capacitor, typical value 0.1 mF and
not greater than 0.47 mF, should be connected from
this pin to the regulated supply at pin 11 to act as a
memory capacitor for the probe 1 measurement.
The internal leakage at this pin is 2 nA max for a
long memory retention time.
Pin 15 Feedback input for the internal supply regulator, normally connected to VREG at pin 11. A resistor may
be connected in series to adjust the regulated output
voltage by an amount corresponding to the 1 mA
current into pin 15.
Pin 16 Linear voltage output for probe 1 and probe 2 capable of driving up to g 10 mA. May be connected with
a 600X meter to VREG.
Input amplifier for thermo-resistive probe with 5 nA
maximum leakage. Clamped to ground at the start of
a probe 1 measurement.
Device ground Ð 0V.
This pin is connected to the emitter of an external
PNP transistor to supply a 200 mA constant current
to the thermo-resistive probe. An internal reference
maintains this pin at VSUPPLY b 2V.
Base connection for the external PNP transistor.
This pin is connected to the thermo-resistive probe
for short and open circuit probe detection.
Supply pin, a 7.5V to a 18V, protected against
a 50V transients.
High Impedance input for second linear voltage
probe with an input range from 1V to 5V. The gain
may be set externally using pin 10.
Probe select and control input. If this pin is taken to
a logic low level, probe 1 is selected and the timing
cycle is initiated. The selection logic is subsequently
latched low until the end of the measurement. If kept
at a low level one shot or repeating probe 1 measurements will be made depending upon pin 9 conditions. A high input level selects probe 2 except during a probe 1 measurement period.
The repeat oscillator timing capacitor is connected
from this pin to ground. A 2 mA current charges up
the capacitor towards 4.3V when the probe 1 measurement cycle is restarted. If this pin is grounded
the repeat oscillator is disabled and only one probe
1 measurement will be made when pin 8 goes low.
4
Application Notes
THERMO-RESISTIVE PROBES Ð OPERATION AND
CONSTRUCTION
These probes work on the principle that when power is dissipated within the probe, the rise in probe temperature is
dependent on the thermal resistance of the surrounding material and as air and other gases are much less efficient
conductors of heat than liquids such as water and oil it is
possible to obtain a measurement of the depth of immersion
of such a probe in a liquid medium. This principle is illustrated in Figure 1 .
TL/H/8709 – 5
FIGURE 2
current with very fine wires to avoid excessive heating and
this current may be optimized to suit a particular type of
wire. The temperature changes involved will give rise to noticeable length changes in the wire used and more sophisticated holders with tensioning devices may be devised to
allow for this.
TL/H/8709 – 4
FIGURE 1
During the measurement period a constant current drive I is
applied to the probe and the voltage across the probe is
sampled both at the start and just before the end of the
measurement period to give DV. RTH Air and RTH Oil represent the different thermal resistances from probe to ambient
in air or oil giving rise fo temperature changes DT1 and DT2
respectively. As a result of these temperature changes the
probe resistance will change by DR1 or DR2 and give corresponding voltage changes DV1 or DV2 per unit length.
Hence
LA
(L b LA)
DV1 a
DV2
DV e
L
L
l
l
and for DV1
DV2, RTH Air
RTH Oil, DV will increase as
the probe length in air increases. For best results the probe
needs to have a high temperature coefficient and low thermal time constant. One way to achieve this is to make use
of resistance wires held in a suitable support frame allowing
free liquid access. Nickel cobalt iron alloy resistance wires
are available with resistivity 50 mXcm and 3300 ppm temperature coefficient which when made up into a probe with 4
c 2 cm 0.08 mm diameter strands between supports (10
cm total) can give the voltage vs time curve shown in Figure
2 for 200 mA probe current. The effect of varying the probe
current is shown in Figure 3. To avoid triggering the probe
failure detection circuits the probe voltage must be between
0.7V and 5.3V (VREG b 6V), hence for 200 mA the permissible probe resistance range is from 3.5X to 24X. The example given has a resistance at room temperature of 9X
which leaves plenty of room for increase during measurements and changes in ambient temperature.
Various arrangements of probe wire are possible for any
given wire gauge and probe current to suit the measurement
range required, some examples are illustrated schematically
in Figure 4. Naturally it is necessary to reduce the probe
TL/H/8709 – 6
FIGURE 3
Probes need not be limited to resistance wire types as any
device with a positive temperature coefficient and sufficiently low thermal resistance to the encapsulation so as not to
mask the change due to the different surrounding mediums,
could be used. Positive temperature coefficient thermistors
are a possibility and while their thermal time constant is likely to be longer than wire the measurement time may be
increased by changing CT to suit.
TL/H/8709 – 7
FIGURE 4
5
Application Notes (Continued)
CIRCUIT OPERATION
1) Thermo-Resistive Probes
These probes require measurements to be made of their
resistance before and after power has been dissipated in
them. With a probe connected as probe 1 in the connection
diagram the LM1042 will start a measurement when pin 8 is
taken to a logic low level (V8 k 0.5V) and the internal timebase ramp generator will start to generate the waveform
shown in Figure 5. At 0.7V, T1, the probe current drive is
switched on supplying a constant 200 mA via the external
PNP transistor and the probe failure circuit is enabled. At 1V
pin 1 is unclamped and C1 stores the probe voltage corresponding to this time, T2. The ramp charge rate is now reduced as CT charges toward 4V. As the 4.1V threshold is
passed a current sink is enabled and CT now discharges.
Between 1.3V and 1.0V, T3 and T4, the amplified pin 1 voltage, representing the change in probe voltage since T2 (and
as the current is constant this is proportional to the resistance change) is gated onto the memory capacitor at pin 14.
At 0.7V, T5, the probe current is switched off and the measurement cycle is complete. In the event of a faulty probe
being detected the memory capacitor is connected to the
regulated supply during the gate period. The device leakage
at pin 14 is a maximum of 2 nA to give a long memory
retention time. The voltage present on pin 14 is amplifed by
1.2 to drive pin 16 with a low impedance, g 10 mA capability, between 0.5V and 4.7V. A new measurement can only be
started by taking pin 8 to a low level again or by means of
the repeat oscillator.
TL/H/8709 – 9
FIGURE 6
TL/H/8709 – 10
FIGURE 7
3) Second Probe Input
A high impedance input for an alternative sensor is available
at pin 7. The voltage applied to this input is amplified and
output at pin 16 when the input is selected with a high level
on pin 8. The gain is defined by the feedback arrangement
shown in Figure 8 with adjustment possible at pin 10. With
pin 10 open the gain is set at a nominal value of 1.2, and
this may be increased by connecting a resistor between pin
10 and ground up to a maximum of 3.4 with pin 10 directly
grounded. A variable resistor may be used to calibrate for
the variations in sensitivity of the sensor used for probe 2.
TL/H/8709–8
FIGURE 5
2) Repetitive Measurement
With a capacitor connected between pin 9 and ground the
repeat oscillator will run with a waveform as shown in Figure
6 and a thermo-resistive probe measurement will be triggered each time pin 9 reaches a threshold of 4.3V, provided
pin 8 is at a logic low level. The repeat oscillator runs independently of the pin 8 control logic.
As the repetition rate is increased localized heating of the
probe and liquid being measured will be the main consideration in determining the minimum acceptable measurement
intervals. Measurements will tend to become more dependent on the amount of fluid movement changing the rate of
heat transfer away from the probe. The typical repeat time
versus timing capacitor value is shown in Figure 7.
TL/H/8709 – 11
FIGURE 8
POWER SUPPLY REGULATOR
The arrangement of the feedback for the supply regulator is
shown in Figure 9. The circuit acts to maintain pin 15 at a
constant 6V and when directly connected to pin 11 the regulated output is held at 6V. If required a resistor R may be
connected between pins 15 and 11 to increase the output
voltage by an amount corresponding typically to 1 mA flowing in R. In this way a variable resistor may be used to trim
out the production tolerance of the regulator by adjusting for
VREG t 6.2V.
6
Application Notes (Continued)
TL/H/8709 – 12
FIGURE 9
PROBE CURRENT REFERENCE CIRCUIT
The circuit defining the probe circuit is given in Figure 10. A
reference voltage is obtained from a bandgap regulator derived current flowing in a diode resistor chain to set up a
voltage 2 volts below the supply. This is applied to an amplifier driving an external PNP transistor to maintain pin 3 at 2V
below supply. The emitter resistance from pin 3 to supply
defines the current which, less the base current, flows in the
probe. Because of the sensitivity of the measurement to
probe current evident in Figure 3 the current should be adjusted by means of a variable resistor to the desired value.
This adjustment may also be used to take out probe tolerances.
TL/H/8709 – 13
FIGURE 10
TYPICAL APPLICATIONS CIRCUIT
A typical automotive application circuit is shown in Figure 11
where the probe selection signal is obtained from the oil
pressure switch. At power up (ignition on) the oil pressure
switch is closed and pin 8 is held low by R4 causing a probe
1 (oil level) measurement to be made. Once the engine has
started the oil pressure switch opens and D1 pulls pin 8 high
changing over to the second auxiliary probe input. The capacitor C5 holds pin 8 high in the event of a stalled engine
so that a second probe 1 measurement can not occur in
disturbed oil. Non-automotive applications may drive pin 8
directly with a logic signal.
TL/H/8709 – 14
FIGURE 11. Typical Application Circuit
7
LM1042 Fluid Level Detector
Ordering Information
Order Number LM1042N
See NS Package Number N16A
Physical Dimensions inches (millimeters)
Lit. Ý 107305
Order Number LM1042N
NS Package Number N16A
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical implant
into the body, or (b) support or sustain life, and whose
failure to perform, when properly used in accordance
with instructions for use provided in the labeling, can
be reasonably expected to result in a significant injury
to the user.
National Semiconductor
Corporation
1111 West Bardin Road
Arlington, TX 76017
Tel: 1(800) 272-9959
Fax: 1(800) 737-7018
2. A critical component is any component of a life
support device or system whose failure to perform can
be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
National Semiconductor
Europe
Fax: (a49) 0-180-530 85 86
Email: cnjwge @ tevm2.nsc.com
Deutsch Tel: (a49) 0-180-530 85 85
English Tel: (a49) 0-180-532 78 32
Fran3ais Tel: (a49) 0-180-532 93 58
Italiano Tel: (a49) 0-180-534 16 80
National Semiconductor
Hong Kong Ltd.
13th Floor, Straight Block,
Ocean Centre, 5 Canton Rd.
Tsimshatsui, Kowloon
Hong Kong
Tel: (852) 2737-1600
Fax: (852) 2736-9960
National Semiconductor
Japan Ltd.
Tel: 81-043-299-2309
Fax: 81-043-299-2408
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.