DIALIGHT LML6-C1-WW-SP

FEATURES / BENEFITS
p Fully modular linear arrays of ultra high
brightness LEDs
PWM SERIES
p Utilizes the latest 100+ lumen LUXEON® Rebel™
LEDs for cool white, 100+ lumen for neutral white
& 50+ lumen for warm white
LINEAR MODULES
p Choice of colour temperatures & optical patterns
p >70% lumen maintenance @ 60,000 hours at
max acceptable ambient temperature
p ETL recognized
p Lifesaver® thermal protection
RECOGNIZED COMPONENT
p Primary heatsinking included
APPLICATION
OPERATING CONDITIONS
p Operating ambient temperature -30ºC to +55ºC (@350mA)
p Requires constant current driver
p Compatible drivers include Dialight Lumidrives PWD60-35-70
Runs 3-8 modules @ 350mA, 2-4 modules @700mA
p Additional heatsinking required when driven @ 700mA
p Linear lighting
p Accent lighting
p Flood lighting
p Street & area lighting
p General illumination
ORDERING INFORMATION
MATERIALS / FINISH
p Six premium flux LUXEON Rebel LEDs per module
p Annodized cast aluminum heatsink
p Polycarbonate cover
p Dialight-Lumidrives optics (OPC 11 Series)
p Modular quick connect cables
p Module to module connector cable included
Typical Colour
(AA) Temperature
CW = 5000K - 6350K
NW = 3800K - 4100K
WW = 2850K - 3250K
Optic (BB)
Connectors (sold seperately)
SP = 5 degree spot
LML6-CON-CAB =
MD = 8 degree med.
Entry cable, driver to 1st module
WD = 20 degree wide
LML6-TER-CAB =
OV = 5X25 degree oval
End plug (required)
FR = 7 degree frosted spot
* Cables use 0.5mm2 AWG12 wires
www.dialight.com
MECHANICAL DIMENSIONS
11.7” x 1.498” x 0.585”
(297.18mm x 38.05mm x 14.86mm)
Mounting hole spacing = 3.22” (81.8mm)
Max screw size #8
Total length for “Z” units connected end to end =
(Z x 11.7) - ((Z-1) x 0.25) (inches)
(Z x 297.2) - ((Z-1) x 6.35) (mm)
Side View
Top View
Dimensions in mm
Example: 2 units total length = 23.15” (588.01)
ASSEMBLY INFORMATION
1) Position ‘tab’ end of first powerwhite module
by input wires/driver. (Do not connect power
to entry cable before completing steps 2-6)
2) Remove cover from module (Do not
remove mask). Modules may be screwed
down onto surface by inserting two M6 or 8/32
flathead screws through screw holes.
3) Insert 6 pin prong from LML6-CON-CAB
entry cable into 6 prong receptacle near tab
end of first module.
4) Insert 4 pin prong from connector cable into
‘notch’ end of module, insert 6 pin prong from
connector cable into ‘tab’ end of next module
(repeat for each additional module).
5) Connector cable wires can be routed
through interior of modules by placing them
into interior wire holders.
6) Insert LML6-TER-CAB 4-pin terminal prong
into ‘notch’ end of last module in run
(required).
INPUT WIRE CHART
Colour wire on
A50-LML6-CON-CAB entry cable
To.
or
Connect to
on PWD60-35-70
White 1
Thermistor
Wire 5
White 2
Thermistor
Wire 6
Red
Driver +
Wire 2 350mA
Wires 1 & 2 700mA
Black
Driver -
Wire 3
Green
Ground
Green / Yellow Stripe
7) Replace covers and connect power to
LM60-CON-CAB
PHOTOMETRIC DATA
TBD
IES 32 files available, consult factory
Dialight reserves the right to make changes at any time in order to supply the best product possible.
The most current version of this document will always be available at:
www.dialight.com/Assets\Brochures_And_Catalogs\Illumination\MDEXLUMPWM.pdf