ETC 2301-08-C

PaCIFIC SCIEnTIFIC
Pacific Scientific 6382 Rose Lane Carpinteria, CA 93013
Cage 02101 Tel 805.576.5000 Fax 805.576.5020
Electro Kinetics Division
Technical Data
www.psekd.com
SURGE ARRESTER
MODEL 2301-08-B AND 2301-08-C
120 Vac or 24 Vdc
•
Application - Lightning and general purpose surge protection
for power circuits on aircraft and ground support equipment.
•
Application References
2301-08-B Replaces Model 2301-08 in older applications other than F-15
Cage 80063 / A3145328
2301-08-C NSN 5920-01-350-1256
Cage 76301 / ST5M1328-002; Cage 26512 / NGA817L
2301-08-C has a high strength Be-Cu housing for extreme vibration environments
•
Nominal System Voltage Rating
120 Vac
24 Vdc
•
Maximum Continuous Operating Voltage
132 Vac
28 Vdc
•
Source Impedance
<50 kVA
unlimited
•
System Frequency Rating
•
DC Sparkover
100 V/s
350 - 450 V
•
Insulation Resistance
50 Vdc
>109 Ω
•
Capacitance
•
Impulse Sparkover
10 V/µs
100 V/µs
1 kV/µs
10 kV/µs
<500
<650
<750
<1000
V
V
V
V
•
Discharge Voltage
1.5 kA, 8/20 µs
3 kA, 8/20 µs
5 kA, 8/20 µs
15 kA, 8/20 µs
<500
<1000
<1800
<5000
V
V
V
V
•
Surge Life
•
Operating Temperature
•
Operating Altitude
•
Weight
•
Symbol
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
DC - 400 Hz
1 kHz
3 kA, 8/20 µs
<12 pF
>100 times
-55 to +70 C
<25,000 m
75 g
TDS230108BC(k)