S Series 100 Watt AC-DC Converters Input voltage range from 85…264 V AC 1 or 2 isolated outputs up to 48 V DC 4 kV AC I/O electric strength test voltage LGA • Rugged electrical and mechanical design • Wide input frequency range from 47...440 Hz • Operating ambient temperature range –40...71°C with convection cooling Selection chart Output 1 Output 2 Input voltage Uo nom Io nom Uo nom Io nom Ui [V DC] 5.1 12 15 24 24 30 48 12 15 24 [A] 16 8 6.5 4.2 4 3.2 2 4 3.2 2 [V DC] 12 15 24 [A] 4 3.2 2 [V AC] 85...264 85...264 85...264 85...264 85...264 85...264 85...264 85...264 85...264 85...264 www.power-one.com Edition 4/04.2001 Type LS 1001-7R LS 1301-7R LS 1501-7R LS 1601-7R LS 2320-7R LS 2540-7R LS 2660-7R LS 2320-7R LS 2540-7R LS 2660-7R Options -9, E, D, V, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 1 Cassette Style S Series Input Input voltage AC Input frequency Input voltage DC Inrush current limitation wide input range 85...264 V AC 47...440 Hz 88...372 V DC by thermistor Output Efficiency Output voltage setting accuracy Output voltage switching noise Line regulation Load regulation Minimum load Current limitation Operation in parallel Hold-up time Ui nom, Io nom Ui nom, Io nom up to 85% ±0.6% Uo nom IEC/EN 61204, total typ. 90 mVpp Ui min...Ui max, Io nom typ. ±0.3% Uo nom Ui nom, 10...100% Io nom, symmetrical output load typ. 0.5% Uo nom not required 0A rectangular U/I characteristic typ. 110% Io nom by current limitation Ui nom, Io nom 80 ms Control and protection Input fuse Input undervoltage lockout Input overvoltage lockout Input transient protection Output Output overvoltage Overtemperature Output voltage adjustment Inhibit Status indication not user accessible varistor no-load, overload and short circuit proof suppressor diode in each output switch-off with auto restart 4 AT typ. 90% Ui min typ. 109% Ui max typ. 130% Uo nom TC typ. 100°C 0...110% Uo nom TTL input, output(s) disabled if open circuit LEDs: OK, inhibit, overload Safety Approvals Class of equipment Protection degree Electric strength test voltage EN 60950, UL 1950, CSA 22.2 No. 950 I/case I/O O/case O/O class I IP 30 2 kV AC 4 kV AC 1 kV AC 0.1 kV AC IEC/EN 61000-4-2, level 4 (8/15 kV) IEC/EN 61000-4-3, level x (20 V/m) IEC/EN 61000-4-4, level 4 (2/4 kV) IEC/EN 61000-4-5, level 3 (2 kV) IEC/EN 61000-4-6, level 3 (10 V) CISPR 22/EN 55022 criterion A criterion A criterion A criterion A criterion A class B EMC Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Conducted disturbances Electromagnetic emissions www.power-one.com Edition 4/04.2001 2 S Series 100 Watt AC-DC Converters Environmental Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Vibration, sinusoidal Shock Bump Random vibration MTBF Ui nom, Io nom, convection cooled Ui nom, Io nom –25...71°C –25...95°C –40...100°C 56 days 0.35 mm/5 gn 100 gn 40 gn 4.9 gn rms 500'000 h non operational IEC/EN 60068-2-3, 93%, 40°C IEC/EN 60068-2-6, 10...60/60...2000 Hz IEC/EN 60068-2-27, 6 ms IEC/EN 60068-2-29, 6 ms IEC/EN 60068-2-64, 20...500 Hz MIL-HDBK-217F, GB, 40°C Options Extended temperature range –40...71°C, ambient, operating Electronic inrush current limitation Output voltage adjustment 40...110% Uo nom, excludes feature R and vice versa Input and/or output undervoltage monitoring, excludes option V Input and/or output undervoltage monitoring (VME), excludes option D Current sharing Cooling plate -9 E P D0…D9 V0, V2, V3 T B1 Pin allocation Pin 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Vo1+ Vo1+ Vo1– Vo1– S+ S– R i D V T N N P P LS 4000 Output 1 Output 1 Sense Sense Control of Uo1 Inhibit Save data ACFAIL Current sharing Protective earth Neutral Phase Vo2+ Vo2+ Vo2– Vo2– Vo1+ Vo1– R i D LS 5000 Output 2 T N N P P Output 2 Output 1 Control of Uo1 Inhibit Save data Current sharing Protective earth Neutral Phase S10002 30 26 22 18 14 10 32 28 24 20 16 12 www.power-one.com Edition 4/04.2001 6 8 4 3 Cassette Style S Series Mechanical data Tolerances ±0.3 mm (0.012") unless otherwise indicated. European Projection 171.93 (DIN 41494) (6.77") 7 TE 5 TE Test jacks Option P (Uo) Option D (Uto) Option D (Uti) 111 (3U) 4.37") Measuring point of case temperature TC 100 (3.93") M4 152 (5.98") LED i LED OK LED IoL 168.5 (6.63") 25.9 (1.02") 09004 11.8 (0.46") 60 (2.36") Accessories Front panels 19" (Schroff/Intermas) Mating H15 connectors with screw, solder, fast-on or press-fit terminals Connector retention facilities and code key system for connector coding Chassis or wall mounting plates for frontal access Universal mounting brackets for chassis or DIN-rail mounting www.power-one.com Edition 4/04.2001 4