M24LR16E-R 16-bit EEPROM with password protection, dual interface & energy harvesting: 400 kHz I²C bus & ISO 15693 RF protocol at 13.56 MHz Datasheet −production data Features I2C interface ■ Two-wire I2C serial interface supports 400 kHz protocol ■ Single supply voltage: – 1.8 V to 5.5 V ■ Byte and Page Write (up to 4 bytes) ■ Random and Sequential read modes ■ Self-timed programming cycle ■ Automatic address incrementing ■ Enhanced ESD/latch-up protection ■ I²C timeout SO8 (MN) 150 mils width UFDFPN8 (MC) 2 x 3 mm TSSOP8 (DW) Contactless interface ■ ISO 15693 and ISO 18000-3 mode 1 compatible ■ 13.56 MHz ±7k Hz carrier frequency ■ To tag: 10% or 100% ASK modulation using 1/4 (26 Kbit/s) or 1/256 (1.6 Kbit/s) pulse position coding Sawn wafer on UV tape From tag: load modulation using Manchester coding with 423 kHz and 484 kHz subcarriers in low (6.6 kbit/s) or high (26 kbit/s) data rate mode. Supports the 53 kbit/s data rate with Fast commands Memory ■ 16-Kbit EEPROM organized into: – 2048 bytes in I2C mode – 512 blocks of 32 bits in RF mode ■ Internal tuning capacitance: 27.5pF ■ ■ 64-bit unique identifier (UID) ■ Read Block & Write (32-bit blocks) Write time – I2C: 5 ms (max.) – RF: 5.75 ms including the internal Verify time ■ More than 1 million write cycles ■ More than 40-year data retention ■ Multiple password protection in RF mode ■ Single password protection in I2C mode ■ Digital output pin ■ User configurable pin: RF write in progress or RF busy mode Energy harvesting ■ Analog pin for energy harvesting ■ 4 sink current configurable ranges June 2012 This is information on a product in full production. ■ Package – ECOPACK2® (RoHS compliant and Halogen-free) Doc ID 018932 Rev 8 1/143 www.st.com 1 Contents M24LR16E-R Contents 1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2 Signal descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.1 Serial clock (SCL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.2 Serial data (SDA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.3 RF Write in progress / RF Busy (RF WIP/BUSY) . . . . . . . . . . . . . . . . . . . 15 2.4 Energy harvesting analog output (Vout) . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.5 Antenna coil (AC0, AC1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.5.1 Device reset in RF mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.6 VSS ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2.7 Supply voltage (VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2.7.1 2.7.2 Operating supply voltage VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Power-up conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2.7.3 Device reset in I²C mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2.7.4 Power-down conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3 User memory organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 4 System memory area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.1 M24LR16E-R block security in RF mode . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.1.1 4.2 M24LR16E-R block security in I²C mode (I2C_Write_Lock bit area) . . . . 27 4.3 Configuration byte and Control register . . . . . . . . . . . . . . . . . . . . . . . . . . 27 4.4 5 2/143 Example of the M24LR16E-R security protection in RF mode . . . . . . . 26 4.3.1 RF WIP/BUSY pin configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 4.3.2 Energy harvesting configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 4.3.3 FIELD_ON indicator bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 4.3.4 Configuration byte access in I²C and RF modes . . . . . . . . . . . . . . . . . . 30 4.3.5 Control register access in I²C or RF mode . . . . . . . . . . . . . . . . . . . . . . 30 ISO 15693 system parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 I2C device operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.1 Start condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.2 Stop condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Doc ID 018932 Rev 8 M24LR16E-R Contents 5.3 Acknowledge bit (ACK) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.4 Data input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.5 I²C timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.5.1 I²C timeout on Start condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.5.2 I²C timeout on clock period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.6 Memory addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.7 Write operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5.8 Byte write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5.9 Page write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5.10 Minimizing system delays by polling on ACK . . . . . . . . . . . . . . . . . . . . . . 37 5.11 Read operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 5.12 Random Address Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 5.13 Current Address Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 5.14 Sequential Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 5.15 Acknowledge in Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 5.16 M24LR16E-R I2C password security . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 5.16.1 I2C present password command description . . . . . . . . . . . . . . . . . . . . . 40 5.16.2 I2C write password command description . . . . . . . . . . . . . . . . . . . . . . . 41 6 M24LR16E-R memory initial state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 7 RF device operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 7.1 RF communication and energy harvesting . . . . . . . . . . . . . . . . . . . . . . . . 43 7.2 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 7.3 Initial dialog for vicinity cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 7.3.1 Power transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 7.3.2 Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 7.3.3 Operating field . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 8 Communication signal from VCD to M24LR16E-R . . . . . . . . . . . . . . . . 46 9 Data rate and data coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 9.1 Data coding mode: 1 out of 256 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 9.2 Data coding mode: 1 out of 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 9.3 VCD to M24LR16E-R frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Doc ID 018932 Rev 8 3/143 Contents M24LR16E-R 9.4 10 11 Communication signal from M24LR16E-R to VCD . . . . . . . . . . . . . . . . 53 10.1 Load modulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 10.2 Subcarrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 10.3 Data rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Bit representation and coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 11.1 11.2 12 Start of frame (SOF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Bit coding using one subcarrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 11.1.1 High data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 11.1.2 Low data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Bit coding using two subcarriers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 11.2.1 High data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 11.2.2 Low data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 M24LR16E-R to VCD frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 12.1 12.2 12.3 12.4 SOF when using one subcarrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 12.1.1 High data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 12.1.2 Low data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SOF when using two subcarriers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 12.2.1 High data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 12.2.2 Low data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 EOF when using one subcarrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 12.3.1 High data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 12.3.2 Low data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 EOF when using two subcarriers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 12.4.1 High data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 12.4.2 Low data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 13 Unique identifier (UID) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 14 Application family identifier (AFI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 15 Data storage format identifier (DSFID) . . . . . . . . . . . . . . . . . . . . . . . . . 63 15.1 16 4/143 CRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 M24LR16E-R protocol description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Doc ID 018932 Rev 8 M24LR16E-R 17 18 19 M24LR16E-R states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 17.1 Power-off state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 17.2 Ready state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 17.3 Quiet state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 17.4 Selected state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 18.1 Addressed mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 18.2 Non-addressed mode (general request) . . . . . . . . . . . . . . . . . . . . . . . . . 68 18.3 Select mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 19.1 20 21 Contents Request flags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Response format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 20.1 Response flags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 20.2 Response error code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Anticollision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 21.1 Request parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 22 Request processing by the M24LR16E-R . . . . . . . . . . . . . . . . . . . . . . . 75 23 Explanation of the possible cases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 24 Inventory Initiated command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 25 Timing definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 26 25.1 t1: M24LR16E-R response delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 25.2 t2: VCD new request delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 25.3 t3: VCD new request delay when no response is received from the M24LR16E-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Command codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 26.1 Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 26.2 Stay Quiet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Doc ID 018932 Rev 8 5/143 Contents M24LR16E-R 26.3 Read Single Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 26.4 Write Single Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 26.5 Read Multiple Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 26.6 Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 26.7 Reset to Ready . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 26.8 Write AFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 26.9 Lock AFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 26.10 Write DSFID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 26.11 Lock DSFID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 26.12 Get System Info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 26.13 Get Multiple Block Security Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 26.14 Write-sector Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 26.15 Lock-sector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 26.16 Present-sector Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 26.17 Fast Read Single Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 26.18 Fast Inventory Initiated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 26.19 Fast Initiate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 26.20 Fast Read Multiple Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 26.21 Inventory Initiated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 26.22 Initiate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 26.23 ReadCfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 26.24 WriteEHCfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 26.25 WriteDOCfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 26.26 SetRstEHEn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 26.27 CheckEHEn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 27 Maximum rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 28 I2C DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 29 RF electrical parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 30 Package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 31 Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 6/143 Doc ID 018932 Rev 8 M24LR16E-R Contents Appendix A Anticollision algorithm (informative) . . . . . . . . . . . . . . . . . . . . . . . 138 A.1 Algorithm for pulsed slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 Appendix B CRC (informative) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 B.1 CRC error detection method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 B.2 CRC calculation example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 Appendix C Application family identifier (AFI) (informative) . . . . . . . . . . . . . . 141 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 Doc ID 018932 Rev 8 7/143 List of tables M24LR16E-R List of tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. Table 20. Table 21. Table 22. Table 23. Table 24. Table 25. Table 26. Table 27. Table 28. Table 29. Table 30. Table 31. Table 32. Table 33. Table 34. Table 35. Table 36. Table 37. Table 38. Table 39. Table 40. Table 41. Table 42. Table 43. Table 44. Table 45. Table 46. Table 47. Table 48. 8/143 Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Device select code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Address most significant byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Address least significant byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Sector details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Sector security status byte area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Sector security status byte organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Read / Write protection bit setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Password control bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Password system area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 M24LR16E-R sector security protection after power-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 M24LR16E-R sector security protection after a valid presentation of password 1 . . . . . . . 26 I2C_Write_Lock bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Configuration byte. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Control register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 EH_enable bit value after power-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 System parameter sector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Operating modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 10% modulation parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Response data rates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 UID format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 CRC transmission rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 VCD request frame format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 M24LR16E-R Response frame format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 M24LR16E-R response depending on Request_flags . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 General request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Definition of request flags 1 to 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Request flags 5 to 8 when Bit 3 = 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Request flags 5 to 8 when Bit 3 = 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 General response format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Definitions of response flags 1 to 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Response error code definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Inventory request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Example of the addition of 0-bits to an 11-bit mask value . . . . . . . . . . . . . . . . . . . . . . . . . 73 Timing values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Command codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Inventory request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Inventory response format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Stay Quiet request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Read Single Block request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Read Single Block response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . 84 Sector security status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Read Single Block response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . 84 Write Single Block request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Write Single Block response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . 85 Write Single Block response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . 86 Read Multiple Block request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Read Multiple Block response format when Error_flag is NOT set. . . . . . . . . . . . . . . . . . . 89 Doc ID 018932 Rev 8 M24LR16E-R Table 49. Table 50. Table 51. Table 52. Table 53. Table 54. Table 55. Table 56. Table 57. Table 58. Table 59. Table 60. Table 61. Table 62. Table 63. Table 64. Table 65. Table 66. Table 67. Table 68. Table 69. Table 70. Table 71. Table 72. Table 73. Table 74. Table 75. Table 76. Table 77. Table 78. Table 79. Table 80. Table 81. Table 82. Table 83. Table 84. Table 85. Table 86. Table 87. Table 88. Table 89. Table 90. Table 91. Table 92. Table 93. Table 94. Table 95. Table 96. Table 97. Table 98. List of tables Sector security status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Read Multiple Block response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . 90 Select request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 Select Block response format when Error_flag is NOT set. . . . . . . . . . . . . . . . . . . . . . . . . 91 Select response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Reset to Ready request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Reset to Ready response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . 92 Reset to ready response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Write AFI request format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Write AFI response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Write AFI response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Lock AFI request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Lock AFI response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Lock AFI response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 Write DSFID request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Write DSFID response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . . . 96 Write DSFID response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Lock DSFID request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Lock DSFID response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . . . . 97 Lock DSFID response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Get System Info request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Get System Info response format when Protocol_extension_flag = 0 and Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Get System Info response format when Protocol_extension_flag = 1 and Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Get System Info response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . 100 Get Multiple Block Security Status request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Get Multiple Block Security Status response format when Error_flag is NOT set . . . . . . 101 Sector security status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Get Multiple Block Security Status response format when Error_flag is set . . . . . . . . . . . 102 Write-sector Password request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Write-sector Password response format when Error_flag is NOT set . . . . . . . . . . . . . . . 103 Write-sector Password response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . 103 Lock-sector request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Sector security status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Lock-sector response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . . . 104 Lock-sector response format when Error_flag is set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Present-sector Password request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 Present-sector Password response format when Error_flag is NOT set . . . . . . . . . . . . . 106 Present-sector Password response format when Error_flag is set . . . . . . . . . . . . . . . . . . 106 Fast Read Single Block request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Fast Read Single Block response format when Error_flag is NOT set . . . . . . . . . . . . . . . 108 Sector security status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Fast Read Single Block response format when Error_flag is set . . . . . . . . . . . . . . . . . . . 108 Fast Inventory Initiated request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Fast Inventory Initiated response format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 Fast Initiate request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Fast Initiate response format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Fast Read Multiple Block request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Fast Read Multiple Block response format when Error_flag is NOT set. . . . . . . . . . . . . . 112 Sector security status if Option_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Fast Read Multiple Block response format when Error_flag is set . . . . . . . . . . . . . . . . . . 113 Doc ID 018932 Rev 8 9/143 List of tables Table 99. Table 100. Table 101. Table 102. Table 103. Table 104. Table 105. Table 106. Table 107. Table 108. Table 109. Table 110. Table 111. Table 112. Table 113. Table 114. Table 115. Table 116. Table 117. Table 118. Table 119. Table 120. Table 121. Table 122. Table 123. Table 124. Table 125. Table 126. Table 127. Table 128. Table 129. Table 130. Table 131. Table 132. Table 133. 10/143 M24LR16E-R Inventory Initiated request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Inventory Initiated response format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Initiate request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Initiate Initiated response format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 ReadCfg request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 ReadCfg response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . . . . . 116 ReadCfg response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 WriteEHCfg request format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 WriteEHCfg response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . . . 117 WriteEHCfg response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 WriteDOCfg request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 WriteDOCfg response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . . . 119 WriteDOCfg response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 SetRstEHEn request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 SetRstEHEn response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . . 120 SetRstEHEn response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 CheckEHEn request format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 CheckEHEn response format when Error_flag is NOT set . . . . . . . . . . . . . . . . . . . . . . . . 121 CheckEHEn response format when Error_flag is set . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 I2C operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 AC test measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 Input parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 I2C DC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 I2C AC characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 RF characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Energy harvesting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 SO8N – 8-lead plastic small outline, 150 mils body width, package data. . . . . . . . . . . . . 134 UFDFPN8 (MLP8) 8-lead ultra thin fine pitch dual flat package no lead 2 x 3 mm, data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TSSOP8 – 8-lead thin shrink small outline, package mechanical data. . . . . . . . . . . . . . . 136 Ordering information scheme for packaged devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 CRC definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 AFI coding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 Doc ID 018932 Rev 8 M24LR16E-R List of figures List of figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Figure 18. Figure 19. Figure 20. Figure 21. Figure 22. Figure 23. Figure 24. Figure 25. Figure 26. Figure 27. Figure 28. Figure 29. Figure 30. Figure 31. Figure 32. Figure 33. Figure 34. Figure 35. Figure 36. Figure 37. Figure 38. Figure 39. Figure 40. Figure 41. Figure 42. Figure 43. Figure 44. Figure 45. Figure 46. Figure 47. Logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 8-pin package connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 I2C Fast mode (fC = 400 kHz): maximum Rbus value versus bus parasitic capacitance (Cbus) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 I2C bus protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Circuit diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Memory sector organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 I²C timeout on Start condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Write mode sequences with I2C_Write_Lock bit = 1 (data write inhibited). . . . . . . . . . . . . 34 Write mode sequences with I2C_Write_Lock bit = 0 (data write enabled) . . . . . . . . . . . . . 36 Write cycle polling flowchart using ACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Read mode sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 I2C present password command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 I2C write password command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 100% modulation waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 10% modulation waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 1 out of 256 coding mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Detail of a time period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 1 out of 4 coding mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 1 out of 4 coding example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 SOF to select 1 out of 256 data coding mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 SOF to select 1 out of 4 data coding mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 EOF for either data coding mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Logic 0, high data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Logic 0, high data rate, fast commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Logic 1, high data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Logic 1, high data rate, fast commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Logic 0, low data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Logic 0, low data rate, fast commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Logic 1, low data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Logic 1, low data rate, fast commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Logic 0, high data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Logic 1, high data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Logic 0, low data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Logic 1, low data rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Start of frame, high data rate, one subcarrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Start of frame, high data rate, one subcarrier, fast commands. . . . . . . . . . . . . . . . . . . . . . 57 Start of frame, low data rate, one subcarrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Start of frame, low data rate, one subcarrier, fast commands . . . . . . . . . . . . . . . . . . . . . . 58 Start of frame, high data rate, two subcarriers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Start of frame, low data rate, two subcarriers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 End of frame, high data rate, one subcarrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 End of frame, high data rate, one subcarrier, fast commands . . . . . . . . . . . . . . . . . . . . . . 59 End of frame, low data rate, one subcarrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 End of frame, low data rate, one subcarrier, Fast commands . . . . . . . . . . . . . . . . . . . . . . 59 End of frame, high data rate, two subcarriers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 End of frame, low data rate, two subcarriers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 M24LR16E-R decision tree for AFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Doc ID 018932 Rev 8 11/143 List of figures Figure 48. Figure 49. Figure 50. Figure 51. Figure 52. Figure 53. Figure 54. Figure 55. Figure 56. Figure 57. Figure 58. Figure 59. Figure 60. Figure 61. Figure 62. Figure 63. Figure 64. Figure 65. Figure 66. Figure 67. Figure 68. Figure 69. Figure 70. Figure 71. Figure 72. Figure 73. Figure 74. Figure 75. Figure 76. Figure 77. Figure 78. Figure 79. Figure 80. Figure 81. Figure 82. Figure 83. Figure 84. Figure 85. Figure 86. Figure 87. Figure 88. Figure 89. 12/143 M24LR16E-R M24LR16E-R protocol timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 M24LR16E-R state transition diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Principle of comparison between the mask, the slot number and the UID . . . . . . . . . . . . . 74 Description of a possible anticollision sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 M24LR16 RF-Busy management following Inventory command . . . . . . . . . . . . . . . . . . . . 82 Stay Quiet frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . . . . . . . 83 Read Single Block frame exchange between VCD and M24LR16E-R. . . . . . . . . . . . . . . . 85 Write Single Block frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . 86 M24LR16 RF-Busy management following Write command . . . . . . . . . . . . . . . . . . . . . . . 87 M24LR16 RF-Wip management following Write command . . . . . . . . . . . . . . . . . . . . . . . . 88 Read Multiple Block frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . 90 Select frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . . . . . . . . . . 91 Reset to Ready frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . . . 92 Write AFI frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . . . . . . . . 94 Lock AFI frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . . . . . . . . 95 Write DSFID frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . . . . . 97 Lock DSFID frame exchange between VCD and M24LR16E-R. . . . . . . . . . . . . . . . . . . . . 98 Get System Info frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . 100 Get Multiple Block Security Status frame exchange between VCD and M24LR16E-R . . 102 Write-sector Password frame exchange between VCD and M24LR16E-R . . . . . . . . . . . 103 Lock-sector frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . . . . . 105 Present-sector Password frame exchange between VCD and M24LR16E-R . . . . . . . . . 107 Fast Read Single Block frame exchange between VCD and M24LR16E-R. . . . . . . . . . . 109 Fast Initiate frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . . . . . 111 Fast Read Multiple Block frame exchange between VCD and M24LR16E-R . . . . . . . . . 113 Initiate frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . . . . . . . . . 115 ReadCfg frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . . . . . . . 116 WriteEHCfg frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . . . . . 118 WriteDOCfg frame exchange between VCD and M24LR16E-R. . . . . . . . . . . . . . . . . . . . 119 SetRstEHEn frame exchange between VCD and M24LR16E-R . . . . . . . . . . . . . . . . . . . 121 CheckEHEn frame exchange between VCD and M24LR16E-R. . . . . . . . . . . . . . . . . . . . 122 AC test measurement I/O waveform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 I2C AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 ASK modulated signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 Vout min vs. Isink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Range 11 domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Range 10 domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Range 01 domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Range 00 domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 SO8N – 8-lead plastic small outline, 150 mils body width, package outline . . . . . . . . . . . 134 UFDFPN8 (MLP8) – 8-lead ultra thin fine pitch dual flat package no lead 2 × 3mm, package outline. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TSSOP8 – 8-lead thin shrink small outline, package outline . . . . . . . . . . . . . . . . . . . . . . 136 Doc ID 018932 Rev 8 M24LR16E-R 1 Description Description The M24LR16E-R device is a dual-interface, electrically erasable programmable memory (EEPROM). It features an I2C interface and can be operated from a VCC power supply. It is also a contactless memory powered by the received carrier electromagnetic wave. The M24LR16E-R is organized as 2048 × 8 bits in the I2C mode and as 512 × 32 bits in the ISO 15693 and ISO 18000-3 mode 1 RF mode. The M24LR16E-R also features an energy harvesting analog output, as well as a userconfigurable digital output pin toggling during either RF write in progress or RF busy mode. Figure 1. Logic diagram VCC Vout SCL SDA AC0 M24LR16E-R AC1 RF WIP/ #64: VSS MS19740V1 I2C uses a two-wire serial interface, comprising a bidirectional data line and a clock line. The devices carry a built-in 4-bit device type identifier code (1010) in accordance with the I2C bus definition. The device behaves as a slave in the I2C protocol, with all memory operations synchronized by the serial clock. Read and Write operations are initiated by a Start condition, generated by the bus master. The Start condition is followed by a device select code and Read/Write bit (RW) (as described in Table 2), terminated by an acknowledge bit. When writing data to the memory, the device inserts an acknowledge bit during the 9th bit time, following the bus master’s 8-bit transmission. When data is read by the bus master, the bus master acknowledges the receipt of the data byte in the same way. Data transfers are terminated by a Stop condition after an Ack for Write, and after a NoAck for Read. In the ISO15693/ISO18000-3 mode 1 RF mode, the M24LR16E-R is accessed via the 13.56 MHz carrier electromagnetic wave on which incoming data are demodulated from the received signal amplitude modulation (ASK: amplitude shift keying). When connected to an antenna, the operating power is derived from the RF energy and no external power supply is required. The received ASK wave is 10% or 100% modulated with a data rate of 1.6 Kbit/s Doc ID 018932 Rev 8 13/143 Description M24LR16E-R using the 1/256 pulse coding mode or a data rate of 26 Kbit/s using the 1/4 pulse coding mode. Outgoing data are generated by the M24LR16E-R load variation using Manchester coding with one or two subcarrier frequencies at 423 kHz and 484 kHz. Data are transferred from the M24LR16E-R at 6.6 Kbit/s in low data rate mode and 26 Kbit/s high data rate mode. The M24LR16E-R supports the 53 Kbit/s fast mode in high data rate mode using one subcarrier frequency at 423 kHz. The M24LR16E-R follows the ISO 15693 and ISO 18000-3 mode 1 recommendation for radio-frequency power and signal interface. The M24LR16E-R provides an Energy harvesting mode on the analog output pin Vout. When the Energy harvesting mode is activated, the M24LR16E-R can output the excess energy coming from the RF field on the Vout analog pin. In case the RF field strength is insufficient or when Energy harvesting mode is disabled, the analog output pin Vout goes into high-Z state and Energy harvesting mode is automatically stopped. The M24LR16E-R features a user configurable digital out pin RF WIP/BUSY that can be used to drive a micro controller interrupt input pin (available only when the M24LR16E-R is correctly powered on the Vcc pin). When configured in the RF write in progress mode (RF WIP mode), the RF WIP/BUSY pin is driven low for the entire duration of the RF internal write operation. When configured in the RF busy mode (RF BUSY mode), the RF WIP/BUSY pin is driven low for the entire duration of the RF command progress. The RF WIP/BUSY pin is an open drain output and must be connected to a pull-up resistor. Table 1. Signal names Signal name Function Vout Energy harvesting Output Analog output SDA Serial Data I/O SCL Serial Clock Input AC0, AC1 Antenna coils I/O VCC Supply voltage RF WIP/BUSY Digital signal VSS Ground Figure 2. Digital output 8-pin package connections Vout AC0 AC1 VSS 1 2 3 4 8 7 6 5 VCC RF WIP/BUSY SCL SDA 1. See Section 30 for package dimensions, and how to identify pin-1. 14/143 Direction Doc ID 018932 Rev 8 MS19742V1 M24LR16E-R Signal descriptions 2 Signal descriptions 2.1 Serial clock (SCL) This input signal is used to strobe all data in and out of the device. In applications where this signal is used by slave devices to synchronize the bus to a slower clock, the bus master must have an open drain output, and a pull-up resistor must be connected from Serial Clock (SCL) to VCC. (Figure 3 indicates how the value of the pull-up resistor can be calculated). In most applications, though, this method of synchronization is not employed, and so the pullup resistor is not necessary, provided that the bus master has a push-pull (rather than open drain) output. 2.2 Serial data (SDA) This bidirectional signal is used to transfer data in or out of the device. It is an open drain output that may be wire-OR’ed with other open drain or open collector signals on the bus. A pull up resistor must be connected from Serial Data (SDA) to VCC. (Figure 3 indicates how the value of the pull-up resistor can be calculated). 2.3 RF Write in progress / RF Busy (RF WIP/BUSY) This configurable output signal is used either to indicate that the M24LR16E-R is executing an internal write cycle from the RF channel or that an RF command is in progress. RF WIP and signals are available only when the M24LR16E-R is powered by the Vcc pin. It is an open drain output and a pull up resistor must be connected from RF WIP/BUSY to VCC. 2.4 Energy harvesting analog output (Vout) This analog output pin is used to deliver the analog voltage Vout available when the Energy harvesting mode is enabled and the RF field strength is sufficient. When the Energy harvesting mode is disabled or the RF field strength is not sufficient, the energy harvesting analog voltage output Vout is in High-Z state. 2.5 Antenna coil (AC0, AC1) These inputs are used to connect the device to an external coil exclusively. It is advised not to connect any other DC or AC path to AC0 or AC1. When correctly tuned, the coil is used to power and access the device using the ISO 15693 and ISO 18000-3 mode 1 protocols. 2.5.1 Device reset in RF mode To ensure a proper reset of the RF circuitry, the RF field must be turned off (100% modulation) for a minimum tRF_OFF period of time. Doc ID 018932 Rev 8 15/143 Signal descriptions 2.6 M24LR16E-R VSS ground VSS is the reference for the VCC supply voltage and Vout analog output voltage. 2.7 Supply voltage (VCC) This pin can be connected to an external DC supply voltage. Note: An internal voltage regulator allows the external voltage applied on VCC to supply the M24LR16E-R, while preventing the internal power supply (rectified RF waveforms) to output a DC voltage on the VCC pin. 2.7.1 Operating supply voltage VCC Prior to selecting the memory and issuing instructions to it, a valid and stable VCC voltage within the specified [VCC(min), VCC(max)] range must be applied (see Table 119). To maintain a stable DC supply voltage, it is recommended to decouple the VCC line with a suitable capacitor (usually of the order of 10 nF) close to the VCC/VSS package pins. This voltage must remain stable and valid until the end of the transmission of the instruction and, for a Write instruction, until the completion of the internal I²C write cycle (tW). 2.7.2 Power-up conditions When the power supply is turned on, VCC rises from VSS to VCC. The VCC rise time must not vary faster than 1V/µs. 2.7.3 Device reset in I²C mode In order to prevent inadvertent write operations during power-up, a power-on reset (POR) circuit is included. At power-up (continuous rise of VCC), the device does not respond to any I²C instruction until VCC has reached the power-on reset threshold voltage (this threshold is lower than the minimum VCC operating voltage defined in Table 119). When VCC passes over the POR threshold, the device is reset and enters the Standby power mode. However, the device must not be accessed until VCC has reached a valid and stable VCC voltage within the specified [VCC(min), VCC(max)] range. In a similar way, during power-down (continuous decrease in VCC), as soon as VCC drops below the power-on reset threshold voltage, the device stops responding to any instruction sent to it. 2.7.4 Power-down conditions During power-down (continuous decay of VCC), the device must be in Standby power mode (mode reached after decoding a Stop condition, assuming that there is no internal write cycle in progress). 16/143 Doc ID 018932 Rev 8 M24LR16E-R Signal descriptions I2C Fast mode (fC = 400 kHz): maximum Rbus value versus bus parasitic capacitance (Cbus) Figure 3. Bus line pull-up resistor (k ) 100 10 4 kΩ When tLOW = 1.3 µs (min value for fC = 400 kHz), the Rbus × Cbus time constant must be below the 400 ns time constant line represented on the left. R bu s × C bu s = Here Rbus × Cbus = 120 ns 4 VCC Rbus 00 ns I²C bus master SCL M24xxx SDA 1 30 pF 10 100 Bus line capacitor (pF) Cbus 1000 ai14796b Figure 4. I2C bus protocol SCL SDA SDA Input Start Condition SCL 1 SDA MSB 2 SDA Change Stop Condition 3 7 8 9 ACK Start Condition SCL 1 SDA MSB 2 3 7 8 9 ACK Stop Condition AI00792B Doc ID 018932 Rev 8 17/143 Signal descriptions Table 2. M24LR16E-R Device select code Device type identifier(1) Device select code Chip Enable address RW b7 b6 b5 b4 b3 b2 b1 b0 1 0 1 0 E2(2) 1 1 RW 1. The most significant bit, b7, is sent first. 2. E2 is not connected to any external pin. It is however used to address the M24LR16E-R as described in Section 3 and Section 4. Table 3. b15 Table 4. b7 18/143 Address most significant byte b14 b13 b12 b11 b10 b9 b8 b3 b2 b1 b0 Address least significant byte b6 b5 b4 Doc ID 018932 Rev 8 M24LR16E-R User memory organization The M24LR16E-R is divided into 16 sectors of 32 blocks of 32 bits, as shown in Table 5. Figure 6 shows the memory sector organization. Each sector can be individually readand/or write-protected using a specific password command. Read and write operations are possible if the addressed data are not in a protected sector. The M24LR16E-R also has a 64-bit block that is used to store the 64-bit unique identifier (UID). The UID is compliant with the ISO 15963 description, and its value is used during the anticollision sequence (Inventory). This block is not accessible by the user and its value is written by ST on the production line. The M24LR16E-R includes an AFI register that stores the application family identifier, and a DSFID register that stores the data storage family identifier used in the anticollision algorithm. The M24LR16E-R has four 32-bit blocks that store an I2C password plus three RF password codes. Figure 5. Circuit diagram Vout Row decoder 3 User memory organization AC0 EEPROM RF WIP/BUSY Latch RF Logic I2 C SCL SDA AC1 RF VCC Power management Contact VCC VCC VSS MS19780V1 Doc ID 018932 Rev 8 19/143 User memory organization Figure 6. M24LR16E-R Memory sector organization Sector security status Sector Area 0 1 2 3 1 Kbit EEPROM sector 1 Kbit EEPROM sector 1 Kbit EEPROM sector 1 Kbit EEPROM sector 5 bits 12 13 14 15 1 Kbit EEPROM sector 1 Kbit EEPROM sector 1 Kbit EEPROM sector 1 Kbit EEPROM sector 5 bits I²C password RF password 1 RF password 2 RF password 3 8-bit DSFID 8-bit AFI 64-bit UID 8-bit configuration System 16-bit I²C Write Lock_bit 80-bit SSS System System 5 bits 5 bits 5 bits 5 bits 5 bits 5 bits System System System System System System MS19741V1 Sector details The M24LR16E-R user memory is divided into 16 sectors. Each sector contains 1024 bits. The protection scheme is described in Section 4: System memory area. In RF mode, a sector provides 32 blocks of 32 bits. Each read and write access is done by block. Read and write block accesses are controlled by a Sector Security Status byte that defines the access rights to the 32 blocks contained in the sector. If the sector is not protected, a Write command updates the complete 32 bits of the selected block. In I2C mode, a sector provides 128 bytes that can be individually accessed in Read and Write modes. When protected by the corresponding I2C_Write_Lock bit, the entire sector is write-protected. To access the user memory, the device select code used for any I2C command must have the E2 Chip Enable address at 0. 20/143 Doc ID 018932 Rev 8 M24LR16E-R User memory organization Table 5. Sector number Sector details RF block address I2C byte address Bits [31:24] Bits [23:16] Bits [15:8] Bits [7:0] 0 0 user user user user 1 4 user user user user 2 8 user user user user 3 12 user user user user 4 16 user user user user 5 20 user user user user 6 24 user user user user 7 28 user user user user 8 32 user user user user 9 36 user user user user 10 40 user user user user 11 44 user user user user 12 48 user user user user 13 52 user user user user 14 56 user user user user 15 60 user user user user 16 64 user user user user 17 68 user user user user 18 72 user user user user 19 76 user user user user 20 80 user user user user 21 84 user user user user 22 88 user user user user 23 92 user user user user 24 96 user user user user 25 100 user user user user 26 104 user user user user 27 108 user user user user 28 112 user user user user 29 116 user user user user 30 120 user user user user 31 124 user user user user 0 Doc ID 018932 Rev 8 21/143 User memory organization Table 5. Sector number 1 ... 22/143 M24LR16E-R Sector details (continued) RF block address I2C byte address Bits [31:24] Bits [23:16] Bits [15:8] Bits [7:0] 32 128 user user user user 33 132 user user user user 34 136 user user user user 35 140 user user user user 36 144 user user user user 37 148 user user user user 38 152 user user user user 39 156 user user user user ... ... ... ... ... ... ... ... ... ... ... ... Doc ID 018932 Rev 8 M24LR16E-R User memory organization Table 5. Sector number Sector details (continued) RF block address I2C byte address Bits [31:24] Bits [23:16] Bits [15:8] Bits [7:0] 480 1920 user user user user 481 1924 user user user user 482 1928 user user user user 483 1932 user user user user 484 1936 user user user user 485 1940 user user user user 486 1944 user user user user 487 1948 user user user user 488 1952 user user user user 489 1956 user user user user 490 1960 user user user user 491 1964 user user user user 492 1968 user user user user 493 1972 user user user user 494 1976 user user user user 495 1980 user user user user 496 1984 user user user user 497 1988 user user user user 498 1992 user user user user 499 1996 user user user user 500 2000 user user user user 501 2004 user user user user 502 2008 user user user user 503 2012 user user user user 504 2016 user user user user 505 2020 user user user user 506 2024 user user user user 507 2028 user user user user 508 2032 user user user user 509 2036 user user user user 510 2040 user user user user 511 2044 user user user user 15 Doc ID 018932 Rev 8 23/143 System memory area M24LR16E-R 4 System memory area 4.1 M24LR16E-R block security in RF mode The M24LR16E-R provides a special protection mechanism based on passwords. In RF mode, each memory sector of the M24LR16E-R can be individually protected by one out of three available passwords, and each sector can also have Read/Write access conditions set. Each memory sector of the M24LR16E-R is assigned with a Sector security status byte including a Sector Lock bit, two Password Control bits and two Read/Write protection bits, as shown in Table 7. Table 6 describes the organization of the Sector security status byte, which can be read using the Read Single Block and Read Multiple Block commands with the Option_flag set to 1. On delivery, the default value of the SSS bytes is set to 00h. Table 6. I2C Sector security status byte area byte address Bits [31:24] Bits [23:16] Bits [15:8] Bits [7:0] E2 = 1 0 SSS 3 SSS 2 SSS 1 SSS 0 E2 = 1 4 SSS 7 SSS 6 SSS 5 SSS 4 E2 = 1 8 SSS 11 SSS 10 SSS 9 SSS 8 E2 = 1 12 SSS 15 SSS 14 SSS 13 SSS 12 Table 7. Sector security status byte organization b7 b6 b5 0 0 0 b4 b3 Password control bits b2 b1 b0 Read / Write protection bits Sector Lock When the Sector Lock bit is set to 1, for instance by issuing a Lock-sector command, the two Read/Write protection bits (b1, b2) are used to set the Read/Write access of the sector as described in Table 8. Table 8. 24/143 Read / Write protection bit setting Sector access Sector access when password presented when password not presented Sector Lock b2, b1 0 xx Read Write Read Write 1 00 Read Write Read No Write 1 01 Read Write Read Write 1 10 Read Write No Read No Write 1 11 Read No Write No Read No Write Doc ID 018932 Rev 8 M24LR16E-R System memory area The next two bits of the Sector security status byte (b3, b4) are the password control bits. The value of these two bits is used to link a password to the sector, as defined in Table 9. Table 9. Password control bits b4, b3 Password 00 The sector is not protected by a password. 01 The sector is protected by password 1. 10 The sector is protected by password 2. 11 The sector is protected by password 3. The M24LR16E-R password protection is organized around a dedicated set of commands, plus a system area of three password blocks where the password values are stored. This system area is described in Table 10. Table 10. Password system area Add 1 Password 1 2 Password 2 3 Password 3 The dedicated commands for protection in RF mode are: ● Write-sector password: The Write-sector password command is used to write a 32-bit block into the password system area. This command must be used to update password values. After the write cycle, the new password value is automatically activated. It is possible to modify a password value after issuing a valid Present-sector password command. On delivery, the three default password values are set to 0000 0000h and are activated. ● Lock-sector: The Lock-sector command is used to set the sector security status byte of the selected sector. Bits b4 to b1 of the sector security status byte are affected by the Lock-sector command. The sector lock bit, b0, is set to 1 automatically. After issuing a Lock-sector command, the protection settings of the selected sector are activated. The protection of a locked block cannot be changed in RF mode. A Lock-sector command sent to a locked sector returns an error code. Doc ID 018932 Rev 8 25/143 System memory area ● M24LR16E-R Present-sector password: The Present-sector password command is used to present one of the three passwords to the M24LR16E-R in order to modify the access rights of all the memory sectors linked to that password (Table 8) including the password itself. If the presented password is correct, the access rights remain activated until the tag is powered off or until a new Present-sector password command is issued. If the presented password value is not correct, all the access rights of all the memory sectors are deactivated. ● Sector security status byte area access conditions in I2C mode: In I2C mode, read access to the sector security status byte area is always allowed. Write access depends on the correct presentation of the I2C password (see Section 5.16.1: I2C present password command description). To access the Sector security status byte area, the device select code used for any I2C command must have the E2 Chip Enable address at 1. An I2C write access to a sector security status byte re-initializes the RF access condition to the given memory sector. 4.1.1 Example of the M24LR16E-R security protection in RF mode Table 11 and Table 12 show the sector security protections before and after a valid Presentsector password command. Table 11 shows the sector access rights of an M24LR16E-R after power-up. After a valid Present-sector password command with password 1, the memory sector access is changed as shown in Table 12. Table 11. M24LR16E-R sector security protection after power-up Sector security status byte Sector address b4 b3 b2 b1 b0 0 Protection: standard Read No Write xxx 0 0 0 0 1 1 Protection: pswd 1 Read No Write xxx 0 1 0 0 1 2 Protection: pswd 1 Read Write xxx 0 1 0 1 1 3 Protection: pswd 1 No Read No Write xxx 0 1 1 0 1 4 Protection: pswd 1 No Read No Write xxx 0 1 1 1 1 Table 12. M24LR16E-R sector security protection after a valid presentation of password 1 Sector security status byte Sector address 26/143 b7b6b5 b7b6b5 b4 b3 b2 b1 b0 0 Protection: standard Read No Write xxx 0 0 0 0 1 1 Protection: pswd 1 Read Write xxx 0 1 0 0 1 2 Protection: pswd 1 Read Write xxx 0 1 0 1 1 3 Protection: pswd 1 Read Write xxx 0 1 1 0 1 4 Protection: pswd 1 Read No Write xxx 0 1 1 1 1 Doc ID 018932 Rev 8 M24LR16E-R 4.2 System memory area M24LR16E-R block security in I²C mode (I2C_Write_Lock bit area) In the I2C mode only, it is possible to protect individual sectors against Write operations. This feature is controlled by the I2C_Write_Lock bits stored in the 2 bytes of the I2C_Write_Lock bit area. I2C_Write_Lock bit area starts from location 2048 (see Table 13). To access the I2C_Write_Lock bit area, the device select code used for any I2C command must have the E2 Chip Enable address at 1. Using these 16 bits, it is possible to write-protect all the 16 sectors of the M24LR16E-R memory. Each bit controls the I2C write access to a specific sector as shown in Table 13. It is always possible to unprotect a sector in the I2C mode. When an I2C_Write_Lock bit is reset to 0, the corresponding sector is unprotected. When the bit is set to 1, the corresponding sector is write-protected. In I2C mode, read access to the I2C_Write_Lock bit area is always allowed. Write access depends on the correct presentation of the I2C password. On delivery, the default value of the eight bytes of the I2C_Write_Lock bit area is reset to 00h. m Table 13. I2C_Write_Lock bit I2C byte address E2 = 1 4.3 2048 Bits [15:8] Bits [7:0] sectors 15-8 sectors 7-0 Configuration byte and Control register The M24LR16E-R offers an 8-bit non-volatile Configuration byte located at I²C location 2320 of the system area used to store the RF WIP/BUSY pin and the energy harvesting configuration (see Table 14). The M24LR16E-R also offers an 8-bit volatile Control register located at I²C location 2336 of the system area used to store the energy harvesting enable bit as well as a FIELD_ON bit indicator (see Table 15). 4.3.1 RF WIP/BUSY pin configuration The M24LR16E-R features a configurable open drain output RF WIP/BUSY pin used to provide RF activity information to an external device. The RF WIP/BUSY pin functionality depends on the value of bit 3 of the Configuration byte. ● RF busy mode When bit 3 of the Configuration byte is set to 0, the RF WIP/BUSY pin is configured in RF busy mode. The purpose of this mode is to indicate to the I²C bus master whether the M24LR16E-R is busy in RF mode or not. In this mode, the RF WIP/BUSY pin is tied to 0 from the RF command Start Of Frame (SOF) until the end of the command execution. Doc ID 018932 Rev 8 27/143 System memory area M24LR16E-R If a bad RF command is received, the RF WIP/BUSY pin is tied to 0 from the RF command SOF until the reception of the RF command CRC. Otherwise, the RF WIP/BUSY pin is in high-Z state. When tied to 0, the RF WIP/BUSY signal returns to High-Z state if the RF field is cut-off. During execution of I²C commands, the RF WIP/BUSY pin remains in high-Z state. ● RF Write in progress When bit 3 of the Configuration byte is set to 1, the RF WIP/BUSY pin is configured in RF Write in progress mode. The purpose of this mode is to indicate to the I²C bus master that some data have been changed in RF mode. In this mode, the RF WIP/BUSY pin is tied to 0 for the duration of an internal write operation (i.e. between the end of a valid RF write command and the beginning of the RF answer). During execution of I²C write operations, the RF WIP/BUSY pin remains in high-Z state. 4.3.2 Energy harvesting configuration The M24LR16E-R features an Energy harvesting mode on the Vout analog output. The general purpose of the Energy harvesting mode is to deliver a part of the nonnecessary RF power received by the M24LR16E-R on the AC0-AC1 RF input in order to supply an external device. The current consumption on the analog voltage output Vout is limited to ensure that the M24LR16E-R is correctly supplied during the powering of the external device. When the Energy harvesting mode is enabled and the power delivered on the AC0-AC1 RF input exceeds the minimum required PAC0-AC1_min, the M24LR16E-R is able to deliver a limited and unregulated voltage on the Vout pin, assuming the current consumption on the Vout does not exceed the Isink_max maximum value. If one of the condition above is not met, the analog voltage output pin Vout is set in High-Z state. For robust applications using the Energy harvesting mode, four current fan-out levels can be chosen. ● Vout sink current configuration The sink current level is chosen by programming EH_cfg1 and EH_cfg0 into the Configuration byte (see Table 14). The minimum power level required on AC0-AC1 RF input PAC0-AC1_min, the delivered voltage Vout, as well as the maximum current consumption Isink_max on the Vout pin corresponding to the <EH_cfg1,EH_cfg0> bit values are described in Table 126. Table 14. I2C Configuration byte byte address Bit 7 Bit 6 Bit 5 Bit 4 E2=1 2320 X(1) X(1) X(1) X(1) Bit 3 RF WIP/BUSY 1. Bit 7 to Bit 4 are don’t care bits. 28/143 Doc ID 018932 Rev 8 Bit 2 BIT 1 BIT 0 EH_mode EH_cfg1 EH_cfg0 M24LR16E-R System memory area Energy harvesting enable control ● Delivery of Energy harvesting analog output voltage on the Vout pin depends on the value of the EH_enable bit of the volatile Control register (see Table 15). Table 15. Control register 2 I C byte address E2=1 2336 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 0(1) 0(1) 0(1) 0(1) 0(1) 0(1) BIT 1 BIT 0 FIELD_ON(1) EH_enable 1. Bit 7 to Bit 1 are read-only bits. ● – When set to 1, the EH_enable bit enables the Energy harvesting mode, meaning that the Vout analog output signal is delivered when the PAC0-AC1_min and Isink_max conditions corresponding to the chosen sink current configuration bit are met (see Table 126). – When set to 0, the EH_enable bit disable the Energy harvesting mode and the analog output Vout remains in set in High-Z state. Energy harvesting default mode control At power-up, in I²C or RF mode, the EH_enable bit is updated according to the value of the EH_mode bit stored in the non-volatile Configuration byte (see Table 16). In other words, the EH_mode bit is used to configure whether the Energy harvesting mode is enabled or not by default. Table 16. 4.3.3 EH_enable bit value after power-up Energy harvesting EH_mode value EH_enable after power-up 0 1 enabled 1 0 disabled after power-up FIELD_ON indicator bit The FIELD_ON bit indicator located as Bit 1 of the Control register is a read-only bit used to indicate when the RF power level delivered to the M24LR16E-R is sufficient to execute RF commands. Note: ● When FIELD_ON = 0, the M24LR16E-R is not able to execute any RF commands. ● When FIELD_ON =1, the M24LR16E-R is able to execute any RF commands. During read access to the Control register in RF mode, the FIELD_ON bit is always read at 1. Doc ID 018932 Rev 8 29/143 System memory area 4.3.4 M24LR16E-R Configuration byte access in I²C and RF modes In I²C mode, read and write accesses to the non-volatile Configuration byte are always allowed. To access the Configuration byte, the device select code used for any I²C command must have the E2 Chip enable address at 1. The dedicated commands to access the Configuration byte in RF mode are: ● Read configuration byte command (ReadCfg): The ReadCfg command is used to read the eight bits of the Configuration byte. ● Write energy harvesting configuration command (WriteEHCfg): The WriteEHCfg command is used to write the EH_mode, EH_cfg1 and EH_cfg0 bits into the Configuration byte. ● Write RF WIP/BUSY pin configuration command (WriteDOCfg): The WriteDOCfg command is used to write the RF WIP/BUSY bit into the Configuration byte. After any write access to the Configuration byte, the new configuration is automatically applied. 4.3.5 Control register access in I²C or RF mode In I²C mode, read and write accesses to the volatile Control register are always allowed. To access the Control register, the device select code used for any I²C command must have the E2 Chip enable address at 1. The dedicated commands to access the Control register in RF mode are: ● Check energy harvesting enable bit command (CheckEHEn): The CheckEHEn command is used to read the eight bits of the Control register. When it is run, the FIELD_ON bit is always read at 1. ● Set/reset energy harvesting enable bit command (SetRstEHEn): The SetRstEHEn command is used to set or reset the value of the EH_enable bit into the Control register. 4.4 ISO 15693 system parameters The M24LR16E-R provides the system area required by the ISO 15693 RF protocol, as shown in Table 17. The first 32-bit block starting from I2C address 2304 stores the I2C password. This password is used to activate/deactivate the write protection of the protected sector in I2C mode. At power-on, all user memory sectors protected by the I2C_Write_Lock bits can be read but cannot be modified. To remove the write protection, it is necessary to use the I2C present password described in Figure 12. When the password is correctly presented — that is, when all the presented bits correspond to the stored ones — it is also possible to modify the I2C password using the I2C write password command described in Figure 13. The next three 32-bit blocks store the three RF passwords. These passwords are neither read- nor write- accessible in the I2C mode. 30/143 Doc ID 018932 Rev 8 M24LR16E-R System memory area The next byte stores the Configuration byte, at I²C location 2320. This Control register is used to store the three energy harvesting configuration bits and the RF WIP/BUSY configuration bit. The next two bytes are used to store the AFI, at I2C location 2322, and the DSFID, at I2C location 2323. These two values are used during the RF inventory sequence. They are readonly in the I2C mode. The next eight bytes, starting from location 2324, store the 64-bit UID programmed by ST on the production line. Bytes at I2C locations 2332 to 2335 store the IC Ref and the Mem_Size data used by the RF Get_System_Info command. The UID, Mem_Size and IC ref values are read-only data. Table 17. System parameter sector I2C byte address Bits [31:24] Bits [23:16] 2C Bits [15:8] password Bits [7:0] (1) E2 = 1 2304 I E2 = 1 2308 RF password 1(1) E2 = 1 2312 RF password 2(1) E2 = 1 2316 RF password 3 (1) E2 = 1 2320 DSFID (FFh) AFI (00h) ST reserved Configuration byte (F4h) E2 = 1 2324 UID UID UID UID E2 = 1 2328 UID (E0h) UID (02h) UID UID E2 = 1 2332 Mem_Size (03 01FFh) IC Ref (4Eh) 1. Delivery state: I2C password= 0000 0000h, RF password = 0000 0000h, Configuration byte = F4h Doc ID 018932 Rev 8 31/143 I2C device operation 5 M24LR16E-R I2C device operation The device supports the I2C protocol. This is summarized in Figure 4. Any device that sends data to the bus is defined as a transmitter, and any device that reads data is defined as a receiver. The device that controls the data transfer is known as the bus master, and the other as the slave device. A data transfer can only be initiated by the bus master, which also provides the serial clock for synchronization. The M24LR16E-R device is a slave in all communications. 5.1 Start condition Start is identified by a falling edge of serial data (SDA) while the serial clock (SCL) is stable in the high state. A Start condition must precede any data transfer command. The device continuously monitors (except during a write cycle) the SDA and the SCL for a Start condition, and does not respond unless one is given. 5.2 Stop condition Stop is identified by a rising edge of serial data (SDA) while the serial clock (SCL) is stable and driven high. A Stop condition terminates communication between the device and the bus master. A Read command that is followed by NoAck can be followed by a Stop condition to force the device into the Standby mode. A Stop condition at the end of a Write command triggers the internal write cycle. 5.3 Acknowledge bit (ACK) The acknowledge bit is used to indicate a successful byte transfer. The bus transmitter, whether it be bus master or slave device, releases the serial data (SDA) after sending eight bits of data. During the 9th clock pulse period, the receiver pulls the SDA low to acknowledge the receipt of the eight data bits. 5.4 Data input During data input, the device samples serial data (SDA) on the rising edge of the serial clock (SCL). For correct device operation, the SDA must be stable during the rising edge of the SCL, and the SDA signal must change only when the SCL is driven low. 5.5 I²C timeout During the execution of an I²C operation, RF communications are not possible. To prevent RF communication freezing due to inadvertent unterminated instructions sent to the I²C bus, the M24LR16E-R features a timeout mechanism that automatically resets the I²C logic block. 32/143 Doc ID 018932 Rev 8 I2C device operation M24LR16E-R 5.5.1 I²C timeout on Start condition I²C communication with the M24LR16E-R starts with a valid Start condition, followed by a device select code. If the delay between the Start condition and the following rising edge of the Serial Clock (SCL) that samples the most significant of the Device Select exceeds the tSTART_OUT time (see Table 123), the I²C logic block is reset and further incoming data transfer is ignored until the next valid Start condition. Figure 7. I²C timeout on Start condition SCL SDA tSTART_OUT Start condition MS19779V1 5.5.2 I²C timeout on clock period During data transfer on the I²C bus, the serial clock high pulse width High (tCHCL) or serial clock pulse width Low (tCLCH) exceeds the maximum value specified in Table 123, the I²C logic block is reset and any further incoming data transfer is ignored until the next valid Start condition. 5.6 Memory addressing To start communication between the bus master and the slave device, the bus master must initiate a Start condition. Following this, the bus master sends the device select code, shown in Table 2 (on Serial Data (SDA), most significant bit first). The device select code consists of a 4-bit device type identifier and a 3-bit Chip Enable “Address” (E2,1,1). To address the memory array, the 4-bit device type identifier is 1010b. Refer to Table 2. The eighth bit is the Read/Write bit (RW). It is set to 1 for Read and to 0 for Write operations. If a match occurs on the device select code, the corresponding device gives an acknowledgment on serial data (SDA) during the ninth bit time. If the device does not match the device select code, it deselects itself from the bus, and goes into Standby mode. Doc ID 018932 Rev 8 33/143 I2C device operation M24LR16E-R Table 18. Operating modes Mode Current address read RW bit Bytes 1 1 Initial sequence Start, device select, RW = 1 0 Start, device select, RW = 0, address Random address read 1 reStart, device select, RW = 1 1 Sequential read 1 ≥1 Byte write 0 1 Start, device select, RW = 0 Page write 0 ≤ 4 bytes Start, device select, RW = 0 Figure 8. Similar to current or random address read Write mode sequences with I2C_Write_Lock bit = 1 (data write inhibited) ACK Byte address Start Dev select Data in ACK Byte address ACK Byte address NO ACK Data in 1 Data in 2 R/W NO ACK NO ACK Data in N Stop Page Write (cont'd) Byte address NO ACK R/W ACK Page Write ACK Stop Dev select Start Byte Write ACK AI15115 34/143 Doc ID 018932 Rev 8 I2C device operation M24LR16E-R 5.7 Write operations Following a Start condition, the bus master sends a device select code with the Read/Write bit (RW) reset to 0. The device acknowledges this, as shown in Figure 8, and waits for two address bytes. The device responds to each address byte with an acknowledge bit, and then waits for the data byte. Writing to the memory may be inhibited if the I2C_Write_Lock bit = 1. A Write instruction issued with the I2C_Write_Lock bit = 1 and with no I2C_Password presented does not modify the memory contents, and the accompanying data bytes are not acknowledged, as shown in Figure 8. Each data byte in the memory has a 16-bit (two byte wide) address. The most significant byte (Table 3) is sent first, followed by the least significant byte (Table 4). Bits b15 to b0 form the address of the byte in memory. When the bus master generates a Stop condition immediately after the Ack bit (in the tenthbit time slot), either at the end of a byte write or a page write, the internal write cycle is triggered. A Stop condition at any other time slot does not trigger the internal write cycle. After the Stop condition, the delay tW, and the successful completion of a Write operation, the device’s internal address counter is incremented automatically, to point to the next byte address after the last one that was modified. During the internal write cycle, the serial data (SDA) signal is disabled internally, and the device does not respond to any requests. 5.8 Byte write After the device select code and the address bytes, the bus master sends one data byte. If the addressed location is write-protected by the I2C_Write_Lock bit (= 1), the device replies with NoAck, and the location is not modified. If the addressed location is not write-protected, the device replies with Ack. The bus master terminates the transfer by generating a Stop condition, as shown in Figure 9. 5.9 Page write The Page write mode allows up to four bytes to be written in a single write cycle, provided that they are all located in the same “row” in the memory: that is, the most significant memory address bits (b12-b2) are the same. If more bytes are sent than fit up to the end of the row, a condition known as “roll-over” occurs. This should be avoided, as data starts to become overwritten in an implementation-dependent way. The bus master sends from one to four bytes of data, each of which is acknowledged by the device if the I2C_Write_Lock bit = 0 or the I2C_Password was correctly presented. If the I2C_Write_Lock_bit = 1 and the I2C_password are not presented, the contents of the addressed memory location are not modified, and each data byte is followed by a NoAck. After each byte is transferred, the internal byte address counter (inside the page) is incremented. The transfer is terminated by the bus master generating a Stop condition. Doc ID 018932 Rev 8 35/143 I2C device operation Figure 9. M24LR16E-R Write mode sequences with I2C_Write_Lock bit = 0 (data write enabled) ACK Byte address Data in ACK Byte address ACK Byte address ACK ACK Data in 1 ACK Data in N Data in 2 Stop Dev Select Start Byte address ACK R/W ACK Page Write ACK Stop Dev Select Start Byte Write ACK R/W AI15116 Figure 10. Write cycle polling flowchart using ACK Write cycle in progress Start condition Device select with RW = 0 NO First byte of instruction with RW = 0 already decoded by the device ACK Returned YES NO Next operation is addressing the memory YES Send address and receive ACK ReStart Stop NO Start condition YES Data for the Write operation Device select with RW = 1 Continue the Write operation Continue the Random Read operation AI01847d 36/143 Doc ID 018932 Rev 8 I2C device operation M24LR16E-R 5.10 Minimizing system delays by polling on ACK During the internal write cycle, the device disconnects itself from the bus, and writes a copy of the data from its internal latches to the memory cells. The maximum I²C write time (tw) is shown in Table 123, but the typical time is shorter. To make use of this, a polling sequence can be used by the bus master. The sequence, as shown in Figure 10, is: 1. Initial condition: a write cycle is in progress. 2. Step 1: the bus master issues a Start condition followed by a device select code (the first byte of the new instruction). 3. Step 2: if the device is busy with the internal write cycle, no Ack is returned and the bus master goes back to Step 1. If the device has terminated the internal write cycle, it responds with an Ack, indicating that the device is ready to receive the second part of the instruction (the first byte of this instruction having been sent during Step 1). Doc ID 018932 Rev 8 37/143 I2C device operation M24LR16E-R Figure 11. Read mode sequences ACK Data out Stop Start Dev select NO ACK R/W ACK Start Dev select * Byte address Dev select * ACK ACK Data out 1 ACK NO ACK Data out N Byte address ACK Byte address ACK Dev select * Start Start ACK R/W ACK Data out R/W R/W Dev select * NO ACK Stop Start Dev select Sequential Random Read ACK Byte address R/W ACK Sequential Current Read ACK Start Random Address Read ACK Stop Current Address Read ACK Data out 1 R/W NO ACK Stop Data out N AI01105d 1. The seven most significant bits of the device select code of a random read (in the first and fourth bytes) must be identical. 38/143 Doc ID 018932 Rev 8 I2C device operation M24LR16E-R 5.11 Read operations Read operations are performed independently of the state of the I2C_Write_Lock bit. After the successful completion of a read operation, the device’s internal address counter is incremented by one, to point to the next byte address. 5.12 Random Address Read A dummy write is first performed to load the address into this address counter (as shown in Figure 11) but without sending a Stop condition. Then, the bus master sends another Start condition, and repeats the device select code, with the Read/Write bit (RW) set to 1. The device acknowledges this, and outputs the contents of the addressed byte. The bus master must not acknowledge the byte, and terminates the transfer with a Stop condition. 5.13 Current Address Read For the Current Address Read operation, following a Start condition, the bus master only sends a device select code with the Read/Write bit (RW) set to 1. The device acknowledges this, and outputs the byte addressed by the internal address counter. The counter is then incremented. The bus master terminates the transfer with a Stop condition, as shown in Figure 11, without acknowledging the byte. 5.14 Sequential Read This operation can be used after a Current Address Read or a Random Address Read. The bus master does acknowledge the data byte output, and sends additional clock pulses so that the device continues to output the next byte in sequence. To terminate the stream of bytes, the bus master must not acknowledge the last byte, and must generate a Stop condition, as shown in Figure 11. The output data come from consecutive addresses, with the internal address counter automatically incremented after each byte output. After the last memory address, the address counter “rolls-over”, and the device continues to output data from memory address 00h. 5.15 Acknowledge in Read mode For all Read commands, the device waits, after each byte read, for an acknowledgment during the ninth bit time. If the bus master does not drive Serial Data (SDA) low during this time, the device terminates the data transfer and switches to its Standby mode. Doc ID 018932 Rev 8 39/143 I2C device operation M24LR16E-R M24LR16E-R I2C password security 5.16 The M24LR16E-R controls I2C sector write access using the 32-bit-long I2C password and the 64-bit I2C_Write_Lock bit area. The I2C password value is managed using two I2C commands: I2C present password and I2C write password. 5.16.1 I2C present password command description The I2C present password command is used in I2C mode to present the password to the M24LR16E-R in order to modify the write access rights of all the memory sectors protected by the I2C_Write_Lock bits, including the password itself. If the presented password is correct, the access rights remain activated until the M24LR16E-R is powered off or until a new I2C present password command is issued. Following a Start condition, the bus master sends a device select code with the Read/Write bit (RW) reset to 0 and the Chip Enable bit E2 at 1. The device acknowledges this, as shown in Figure 12, and waits for two I2C password address bytes 09h and 00h. The device responds to each address byte with an acknowledge bit, and then waits for the four password data bytes, the validation code, 09h, and a resend of the four password data bytes. The most significant byte of the password is sent first, followed by the least significant bytes. It is necessary to send the 32-bit password twice to prevent any data corruption during the sequence. If the two 32-bit passwords sent are not exactly the same, the M24LR16E-R does not start the internal comparison. When the bus master generates a Stop condition immediately after the Ack bit (during the tenth bit time slot), an internal delay equivalent to the write cycle time is triggered. A Stop condition at any other time does not trigger the internal delay. During that delay, the M24LR16E-R compares the 32 received data bits with the 32 bits of the stored I2C password. If the values match, the write access rights to all protected sectors are modified after the internal delay. If the values do not match, the protected sectors remains protected. During the internal delay, the serial data (SDA) signal is disabled internally, and the device does not respond to any requests. Figure 12. I2C present password command Ack Start Device select code Ack Password address 09h Ack Password address 00h Ack Password [31:24] Ack Password [23:16] Password [15:8] Ack Password [7:0] R/W Ack Validation code 09h Password [31:24] Ack Password [23:16] Ack Password [15:8] Ack Password [7:0] Stop Ack Device select code = 1010 1 1 1 Ack generated during 9th bit time slot. 40/143 Ack ai15125c Doc ID 018932 Rev 8 I2C device operation M24LR16E-R I2C write password command description 5.16.2 The I2C write password command is used to write a 32-bit block into the M24LR16E-R I2C password system area. This command is used in I2C mode to update the I2C password value. It cannot be used to update any of the RF passwords. After the write cycle, the new I2C password value is automatically activated. The I2C password value can only be modified after issuing a valid I2C present password command. On delivery, the I2C default password value is set to 0000 0000h and is activated. Following a Start condition, the bus master sends a device select code with the Read/Write bit (RW) reset to 0 and the Chip Enable bit E2 at 1. The device acknowledges this, as shown in Figure 13, and waits for the two I2C password address bytes, 09h and 00h. The device responds to each address byte with an acknowledge bit, and then waits for the four password data bytes, the validation code, 07h, and a resend of the four password data bytes. The most significant byte of the password is sent first, followed by the least significant bytes. It is necessary to send twice the 32-bit password to prevent any data corruption during the write sequence. If the two 32-bit passwords sent are not exactly the same, the M24LR16E-R does not modify the I2C password value. When the bus master generates a Stop condition immediately after the Ack bit (during the tenth bit time slot), the internal write cycle is triggered. A Stop condition at any other time does not trigger the internal write cycle. During the internal write cycle, the serial data (SDA) signal is disabled internally, and the device does not respond to any requests. Figure 13. I2C write password command Ack Start Device select code Ack Password address 09h Ack Password address 00h Ack New password [31:24] Ack New password [23:16] Ack New password [15:8] Ack New password [7:0] R/W Validation code 07h Ack New password [31:24] Ack New password [23:16] Ack New password [15:8] Ack New password [7:0] Stop Ack Device select code = 1010 1 1 1 Ack generated during 9th bit time slot. ai15126b Doc ID 018932 Rev 8 41/143 M24LR16E-R memory initial state 6 M24LR16E-R M24LR16E-R memory initial state The device is delivered with all bits in the user memory array set to 1 (each byte contains FFh). The DSFID is programmed to FFh and the AFI is programmed to 00h. Configuration byte set to F4h: 42/143 ● Bit 7 to bit 4: all set to 1 ● Bit 3: set to 0 (RF BUSY mode on RF WIP/BUSY pin) ● Bit 2: set to 1 (Energy harvesting not activated by default) ● Bit 1 and bit 0: set to 0 Doc ID 018932 Rev 8 M24LR16E-R 7 RF device operation RF device operation The M24LR16E-R is divided into 16 sectors of 32 blocks of 32 bits, as shown in Table 5. Each sector can be individually read- and/or write-protected using a specific lock or password command. Read and Write operations are possible if the addressed block is not protected. During a Write, the 32 bits of the block are replaced by the new 32-bit value. The M24LR16E-R also has a 64-bit block that is used to store the 64-bit unique identifier (UID). The UID is compliant with the ISO 15963 description, and its value is used during the anticollision sequence (Inventory). This block is not accessible by the user and its value is written by ST on the production line. The M24LR16E-R also includes an AFI register in which the application family identifier is stored, and a DSFID register in which the data storage family identifier used in the anticollision algorithm is stored. The M24LR16E-R has three 32-bit blocks in which the password codes are stored and a 8bit Configuration byte in which the Energy harvesting mode and RF WIP/BUSY pin configuration is stored. 7.1 RF communication and energy harvesting Because current consumption can affect the AC signal delivered by the antenna, RF communications with M24LR16E-R are not guaranteed during voltage delivery on the energy harvesting analog output Vout. RF communication can disturb and possibly stop Energy Harvesting mode. Doc ID 018932 Rev 8 43/143 RF device operation 7.2 M24LR16E-R Commands The M24LR16E-R supports the following commands: 44/143 ● Inventory, used to perform the anticollision sequence. ● Stay quiet, used to put the M24LR16E-R in quiet mode, where it does not respond to any inventory command. ● Select, used to select the M24LR16E-R. After this command, the M24LR16E-R processes all Read/Write commands with Select_flag set. ● Reset to ready, used to put the M24LR16E-R in the ready state. ● Read block, used to output the 32 bits of the selected block and its locking status. ● Write block, used to write the 32-bit value in the selected block, provided that it is not locked. ● Read multiple blocks, used to read the selected blocks and send back their value. ● Write AFI, used to write the 8-bit value in the AFI register. ● Lock AFI, used to lock the AFI register. ● Write DSFID, used to write the 8-bit value in the DSFID register. ● Lock DSFID, used to lock the DSFID register. ● Get system info, used to provide the system information value ● Get multiple block security status, used to send the security status of the selected block. ● Initiate, used to trigger the tag response to the Inventory initiated sequence. ● Inventory initiated, used to perform the anticollision sequence triggered by the Initiate command. ● Write-sector password, used to write the 32 bits of the selected password. ● Lock-sector, used to write the sector security status bits of the selected sector. ● Present-sector password, enables the user to present a password to unprotect the user blocks linked to this password. ● Fast initiate, used to trigger the tag response to the Inventory initiated sequence. ● Fast inventory initiated, used to perform the anticollision sequence triggered by the Initiate command. ● Fast read single block, used to output the 32 bits of the selected block and its locking status. ● Fast read multiple blocks, used to read the selected blocks and send back their value. ● ReadCfg, used to read the 8-bit Configuration byte and send back its value. ● WriteEHCfg, used to write the energy harvesting configuration bits into the Configuration byte. ● WriteDOCfg, used to write the RF WIP/BUSY pin configuration bit into the Configuration byte. ● SetRstEHEn, used to set or reset the EH_enable bit into the volatile Control register. ● CheckEHEn, used to send back the value of the volatile Control register. Doc ID 018932 Rev 8 M24LR16E-R 7.3 RF device operation Initial dialog for vicinity cards The dialog between the vicinity coupling device or VCD (commonly the “RF reader”) and the vicinity integrated circuit card or VICC (M24LR16E-R) takes place as follows: ● activation of the M24LR16E-R by the RF operating field of the VCD, ● transmission of a command by the VCD, ● transmission of a response by the M24LR16E-R. These operations use the RF power transfer and communication signal interface described below (see Power transfer, Frequency and Operating field). This technique is called RTF (Reader talk first). 7.3.1 Power transfer Power is transferred to the M24LR16E-R by radio frequency at 13.56 MHz via coupling antennas in the M24LR16E-R and the VCD. The RF operating field of the VCD is transformed on the M24LR16E-R antenna to an AC voltage which is rectified, filtered and internally regulated. During communications, the amplitude modulation (ASK) on this received signal is demodulated by the ASK demodulator. 7.3.2 Frequency The ISO 15693 standard defines the carrier frequency (fC) of the operating field as 13.56 MHz ±7 kHz. 7.3.3 Operating field The M24LR16E-R operates continuously between the minimum and maximum values of the electromagnetic field H defined in Table 124. The VCD has to generate a field within these limits. Doc ID 018932 Rev 8 45/143 Communication signal from VCD to M24LR16E-R 8 M24LR16E-R Communication signal from VCD to M24LR16E-R Communications between the VCD and the M24LR16E-R takes place using the modulation principle of ASK (Amplitude shift keying). Two modulation indexes are used, 10% and 100%. The M24LR16E-R decodes both. The VCD determines which index is used. The modulation index is defined as [a – b]/[a + b], where a is the peak signal amplitude, and b the minimum signal amplitude of the carrier frequency. Depending on the choice made by the VCD, a “pause” is created as described in Figure 14 and Figure 15. The M24LR16E-R is operational for the 100% modulation index or for any degree of modulation index between 10% and 30% (see Table 124). Figure 14. 100% modulation waveform t1 t3 Carrier Amplitude t4 105% a 95% 60% t2 5% t b t1 t2 t3 t4 Min (µs) Max (µs) 9,44 6,0 2,1 t1 0 4,5 0 0,8 The clock recovery shall be operational after t4 max. ai15793 46/143 Doc ID 018932 Rev 8 M24LR16E-R Communication signal from VCD to M24LR16E-R Table 19. 10% modulation parameters Symbol Parameter definition Value hr 0.1 x (a – b) max hf 0.1 x (a – b) max Figure 15. 10% modulation waveform Carrier Amplitude t1 t2 t3 y hf a b hr y t t1 t2 t3 Min 6,0 µs 3,0 µs 0 Max 9,44 µs t1 4,5 µs Modulation Index 10% 30% y hf, hr 0,05 (a-b) 0,1 (a-b) max The VICC shall be operational for any value of modulation index between 10 % and 30 %. ai15794 Doc ID 018932 Rev 8 47/143 Data rate and data coding 9 M24LR16E-R Data rate and data coding The data coding implemented in the M24LR16E-R uses pulse position modulation. Both data coding modes that are described in the ISO15693 are supported by the M24LR16E-R. The selection is made by the VCD and indicated to the M24LR16E-R within the start of frame (SOF). 9.1 Data coding mode: 1 out of 256 The value of one single byte is represented by the position of one pause. The position of the pause on 1 of 256 successive time periods of 18.88 µs (256/fC) determines the value of the byte. In this case, the transmission of one byte takes 4.833 ms and the resulting data rate is 1.65 Kbits/s (fC/8192). Figure 16 illustrates this pulse position modulation technique. In this figure, data E1h (225 decimal) is sent by the VCD to the M24LR16E-R. The pause occurs during the second half of the position of the time period that determines the value, as shown in Figure 17. A pause during the first period transmits the data value 00h. A pause during the last period transmits the data value FFh (255 decimal). Figure 16. 1 out of 256 coding mode 9.44 µs Pulse Modulated Carrier 18.88 µs 0 1 2 3 . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 5 2 2 5 3 2 5 4 2 5 5 4.833 ms AI06656 48/143 Doc ID 018932 Rev 8 M24LR16E-R Data rate and data coding Figure 17. Detail of a time period 9.44 µs 18.88 µs Pulse Modulated Carrier . . . . . . . . 2 2 4 2 2 5 . . . . . 2 2 6 Time Period one of 256 9.2 . AI06657 Data coding mode: 1 out of 4 The value of two bits is represented by the position of one pause. The position of the pause on 1 of 4 successive time periods of 18.88 µs (256/fC) determines the value of the two bits. Four successive pairs of bits form a byte, where the least significant pair of bits is transmitted first. In this case, the transmission of one byte takes 302.08 µs and the resulting data rate is 26.48 Kbits/s (fC/512). Figure 18 illustrates the 1 out of 4 pulse position technique and coding. Figure 19 shows the transmission of E1h (225d - 1110 0001b) by the VCD. Doc ID 018932 Rev 8 49/143 Data rate and data coding M24LR16E-R Figure 18. 1 out of 4 coding mode Pulse position for "00" 9.44 µs 9.44 µs 75.52 µs Pulse position for "01" (1=LSB) 28.32 µs 9.44 µs 75.52 µs Pulse position for "10" (0=LSB) 47.20µs Pulse position for "11" 9.44 µs 75.52 µs 66.08 µs 9.44 µs 75.52 µs AI06658 Figure 19. 1 out of 4 coding example 10 00 01 11 75.52µs 75.52µs 75.52µs 75.52µs AI06659 50/143 Doc ID 018932 Rev 8 M24LR16E-R 9.3 Data rate and data coding VCD to M24LR16E-R frames Frames are delimited by a start of frame (SOF) and an end of frame (EOF). They are implemented using code violation. Unused options are reserved for future use. The M24LR16E-R is ready to receive a new command frame from the VCD 311.5 µs (t2) after sending a response frame to the VCD. The M24LR16E-R takes a power-up time of 0.1 ms after being activated by the powering field. After this delay, the M24LR16E-R is ready to receive a command frame from the VCD. 9.4 Start of frame (SOF) The SOF defines the data coding mode the VCD is to use for the following command frame. The SOF sequence described in Figure 20 selects the 1 out of 256 data coding mode. The SOF sequence described in Figure 21 selects the 1 out of 4 data coding mode. The EOF sequence for either coding mode is described in Figure 22. Figure 20. SOF to select 1 out of 256 data coding mode 9.44µs 9.44µs 37.76µs 37.76µs AI06661 Figure 21. SOF to select 1 out of 4 data coding mode 9.44µs 9.44µs 37.76µs 9.44µs 37.76µs AI06660 Doc ID 018932 Rev 8 51/143 Data rate and data coding M24LR16E-R Figure 22. EOF for either data coding mode 9.44µs 9.44µs 37.76µs AI06662 52/143 Doc ID 018932 Rev 8 M24LR16E-R 10 Communication signal from M24LR16E-R to VCD Communication signal from M24LR16E-R to VCD The M24LR16E-R has several modes defined for some parameters, owing to which it can operate in various noise environments and meet various application requirements. 10.1 Load modulation The M24LR16E-R is capable of communication to the VCD via an inductive coupling area whereby the carrier is loaded to generate a subcarrier with frequency fS. The subcarrier is generated by switching a load in the M24LR16E-R. The load-modulated amplitude received on the VCD antenna must be of at least 10 mV when measured as described in the test methods defined in International Standard ISO10373-7. 10.2 Subcarrier The M24LR16E-R supports the one-subcarrier and two-subcarrier response formats. These formats are selected by the VCD using the first bit in the protocol header. When one subcarrier is used, the frequency fS1 of the subcarrier load modulation is 423.75 kHz (fC/32). When two subcarriers are used, the frequency fS1 is 423.75 kHz (fC/32), and frequency fS2 is 484.28 kHz (fC/28). When using the two-subcarrier mode, the M24LR16E-R generates a continuous phase relationship between fS1 and fS2. 10.3 Data rates The M24LR16E-R can respond using the low or the high data rate format. The selection of the data rate is made by the VCD using the second bit in the protocol header. For fast commands, the selected data rate is multiplied by two. Table 20 shows the different data rates produced by the M24LR16E-R using the different response format combinations. Table 20. Response data rates Data rate One subcarrier Two subcarriers Standard commands 6.62 Kbit/s (fc/2048) 6.67 Kbit/s (fc/2032) Fast commands 13.24 Kbit/s (fc/1024) not applicable Standard commands 26.48 Kbit/s (fc/512) 26.69 Kbit/s (fc/508) Fast commands 52.97 Kbit/s (fc/256) not applicable Low High Doc ID 018932 Rev 8 53/143 Bit representation and coding 11 M24LR16E-R Bit representation and coding Data bits are encoded using Manchester coding, according to the following schemes. For the low data rate, same subcarrier frequency or frequencies is/are used. In this case, the number of pulses is multiplied by 4 and all times increase by this factor. For the Fast commands using one subcarrier, all pulse numbers and times are divided by 2. 11.1 Bit coding using one subcarrier 11.1.1 High data rate A logic 0 starts with eight pulses at 423.75 kHz (fC/32) followed by an unmodulated time of 18.88 µs, as shown in Figure 23. Figure 23. Logic 0, high data rate 37.76µs ai12076 For the fast commands, a logic 0 starts with four pulses at 423.75 kHz (fC/32) followed by an unmodulated time of 9.44 µs, as shown in Figure 24. Figure 24. Logic 0, high data rate, fast commands 18.88µs ai12066 A logic 1 starts with an unmodulated time of 18.88 µs followed by eight pulses at 423.75 kHz (fC/32), as shown in Figure 25. Figure 25. Logic 1, high data rate 37.76µs ai12077 For the Fast commands, a logic 1 starts with an unmodulated time of 9.44 µs followed by four pulses of 423.75 kHz (fC/32), as shown in Figure 26. Figure 26. Logic 1, high data rate, fast commands 18.88µs ai12067 54/143 Doc ID 018932 Rev 8 M24LR16E-R 11.1.2 Bit representation and coding Low data rate A logic 0 starts with 32 pulses at 423.75 kHz (fC/32) followed by an unmodulated time of 75.52 µs, as shown in Figure 27. Figure 27. Logic 0, low data rate 151.04µs ai12068 For the Fast commands, a logic 0 starts with 16 pulses at 423.75 kHz (fC/32) followed by an unmodulated time of 37.76 µs, as shown in Figure 28. Figure 28. Logic 0, low data rate, fast commands 75.52µs ai12069 A logic 1 starts with an unmodulated time of 75.52 µs followed by 32 pulses at 423.75 kHz (fC/32), as shown in Figure 29. Figure 29. Logic 1, low data rate 151.04µs ai12070 For the Fast commands, a logic 1 starts with an unmodulated time of 37.76 µs followed by 16 pulses at 423.75 kHz (fC/32), as shown in Figure 30. Figure 30. Logic 1, low data rate, fast commands 75.52µs Doc ID 018932 Rev 8 ai12071 55/143 Bit representation and coding M24LR16E-R 11.2 Bit coding using two subcarriers 11.2.1 High data rate A logic 0 starts with eight pulses at 423.75 kHz (fC/32) followed by nine pulses at 484.28 kHz (fC/28), as shown in Figure 31. Bit coding using two subcarriers is not supported for the Fast commands. Figure 31. Logic 0, high data rate 37.46µs ai12074 A logic 1 starts with nine pulses at 484.28 kHz (fC/28) followed by eight pulses at 423.75 kHz (fC/32), as shown in Figure 32. Bit coding using two subcarriers is not supported for the Fast commands. Figure 32. Logic 1, high data rate 37.46µs 11.2.2 ai12073 Low data rate A logic 0 starts with 32 pulses at 423.75 kHz (fC/32) followed by 36 pulses at 484.28 kHz (fC/28), as shown in Figure 33. Bit coding using two subcarriers is not supported for the Fast commands. Figure 33. Logic 0, low data rate 149.84µs ai12072 A logic 1 starts with 36 pulses at 484.28 kHz (fC/28) followed by 32 pulses at 423.75 kHz (fC/32) as shown in Figure 34. Bit coding using two subcarriers is not supported for the Fast commands. Figure 34. Logic 1, low data rate 149.84µs 56/143 Doc ID 018932 Rev 8 ai12075 M24LR16E-R 12 M24LR16E-R to VCD frames M24LR16E-R to VCD frames Frames are delimited by an SOF and an EOF. They are implemented using code violation. Unused options are reserved for future use. For the low data rate, the same subcarrier frequency or frequencies is/are used. In this case, the number of pulses is multiplied by 4. For the Fast commands using one subcarrier, all pulse numbers and times are divided by 2. 12.1 SOF when using one subcarrier 12.1.1 High data rate The SOF includes an unmodulated time of 56.64 µs, followed by 24 pulses at 423.75 kHz (fC/32), and a logic 1 that consists of an unmodulated time of 18.88 µs followed by eight pulses at 423.75 kHz, as shown in Figure 35. Figure 35. Start of frame, high data rate, one subcarrier 37.76µs 113.28µs ai12078 For the Fast commands, the SOF comprises an unmodulated time of 28.32 µs, followed by 12 pulses at 423.75 kHz (fC/32), and a logic 1 that consists of an unmodulated time of 9.44 µs followed by four pulses at 423.75 kHz, as shown in Figure 36. Figure 36. Start of frame, high data rate, one subcarrier, fast commands 56.64µs 18.88µs ai12079 12.1.2 Low data rate The SOF comprises an unmodulated time of 226.56 µs, followed by 96 pulses at 423.75 kHz (fC/32), and a logic 1 that consists of an unmodulated time of 75.52 µs followed by 32 pulses at 423.75 kHz, as shown in Figure 37. Figure 37. Start of frame, low data rate, one subcarrier 453.12µs 151.04µs ai12080 Doc ID 018932 Rev 8 57/143 M24LR16E-R to VCD frames M24LR16E-R For the Fast commands, the SOF comprises an unmodulated time of 113.28 µs, followed by 48 pulses at 423.75 kHz (fC/32), and a logic 1 that includes an unmodulated time of 37.76 µs followed by 16 pulses at 423.75 kHz, as shown in Figure 38. Figure 38. Start of frame, low data rate, one subcarrier, fast commands 226.56µs 75.52µs ai12081 12.2 SOF when using two subcarriers 12.2.1 High data rate The SOF comprises 27 pulses at 484.28 kHz (fC/28), followed by 24 pulses at 423.75 kHz (fC/32), and a logic 1 that includes nine pulses at 484.28 kHz followed by eight pulses at 423.75 kHz, as shown in Figure 39. Bit coding using two subcarriers is not supported for the Fast commands. Figure 39. Start of frame, high data rate, two subcarriers 112.39µs 12.2.2 37.46µs ai12082 Low data rate The SOF comprises 108 pulses at 484.28 kHz (fC/28), followed by 96 pulses at 423.75 kHz (fC/32), and a logic 1 that includes 36 pulses at 484.28 kHz followed by 32 pulses at 423.75 kHz, as shown in Figure 40. Bit coding using two subcarriers is not supported for the Fast commands. Figure 40. Start of frame, low data rate, two subcarriers 449.56µs 149.84µs ai12083 58/143 Doc ID 018932 Rev 8 M24LR16E-R M24LR16E-R to VCD frames 12.3 EOF when using one subcarrier 12.3.1 High data rate The EOF comprises a logic 0 that includes eight pulses at 423.75 kHz and an unmodulated time of 18.88 µs, followed by 24 pulses at 423.75 kHz (fC/32), and by an unmodulated time of 56.64 µs, as shown in Figure 41. Figure 41. End of frame, high data rate, one subcarrier 37.76µs 113.28µs ai12084 For the Fast commands, the EOF comprises a logic 0 that includes four pulses at 423.75 kHz and an unmodulated time of 9.44 µs, followed by 12 pulses at 423.75 kHz (fC/32) and an unmodulated time of 37.76 µs, as shown in Figure 42. Figure 42. End of frame, high data rate, one subcarrier, fast commands 18.88µs 56.64µs ai12085 12.3.2 Low data rate The EOF comprises a logic 0 that includes 32 pulses at 423.75 kHz and an unmodulated time of 75.52 µs, followed by 96 pulses at 423.75 kHz (fC/32) and an unmodulated time of 226.56 µs, as shown in Figure 43. Figure 43. End of frame, low data rate, one subcarrier 453.12µs 151.04µs ai12086 For the Fast commands, the EOF comprises a logic 0 that includes 16 pulses at 423.75 kHz and an unmodulated time of 37.76 µs, followed by 48 pulses at 423.75 kHz (fC/32) and an unmodulated time of 113.28 µs, as shown in Figure 44. Figure 44. End of frame, low data rate, one subcarrier, Fast commands 75.52µs 226.56µs ai12087 Doc ID 018932 Rev 8 59/143 M24LR16E-R to VCD frames M24LR16E-R 12.4 EOF when using two subcarriers 12.4.1 High data rate The EOF comprises a logic 0 that includes eight pulses at 423.75 kHz and nine pulses at 484.28 kHz, followed by 24 pulses at 423.75 kHz (fC/32) and 27 pulses at 484.28 kHz (fC/28), as shown in Figure 45. Bit coding using two subcarriers is not supported for the Fast commands. Figure 45. End of frame, high data rate, two subcarriers 37.46µs 12.4.2 112.39µs ai12088 Low data rate The EOF comprises a logic 0 that includes 32 pulses at 423.75 kHz and 36 pulses at 484.28 kHz, followed by 96 pulses at 423.75 kHz (fC/32) and 108 pulses at 484.28 kHz (fC/28), as shown in Figure 46. Bit coding using two subcarriers is not supported for the Fast commands. Figure 46. End of frame, low data rate, two subcarriers 149.84µs 449.56µs ai12089 60/143 Doc ID 018932 Rev 8 M24LR16E-R 13 Unique identifier (UID) Unique identifier (UID) The M24LR16E-R is uniquely identified by a 64-bit unique identifier (UID). This UID complies with ISO/IEC 15963 and ISO/IEC 7816-6. The UID is a read-only code and comprises: ● eight MSBs with a value of E0h, ● the IC manufacturer code “ST 02h” on 8 bits (ISO/IEC 7816-6/AM1), ● a unique serial number on 48 bits. Table 21. UID format MSB 63 LSB 56 55 0xE0 48 47 0x02 0 Unique serial number With the UID, each M24LR16E-R can be addressed uniquely and individually during the anticollision loop and for one-to-one exchanges between a VCD and an M24LR16E-R. Doc ID 018932 Rev 8 61/143 Application family identifier (AFI) 14 M24LR16E-R Application family identifier (AFI) The AFI (application family identifier) represents the type of application targeted by the VCD and is used to identify, among all the M24LR16E-Rs present, only the M24LR16E-Rs that meet the required application criteria. Figure 47. M24LR16E-R decision tree for AFI Inventory request received No AFI flag set ? Yes AFI value =0? No Yes AFI value = Internal value ? No Yes Answer given by the M24RF64 to the Inventory request No answer AI15130 The AFI is programmed by the M24LR16E-R issuer (or purchaser) in the AFI register. Once programmed and locked, it can no longer be modified. The most significant nibble of the AFI is used to code one specific or all application families. The least significant nibble of the AFI is used to code one specific or all application subfamilies. Subfamily codes different from 0 are proprietary. (See ISO 15693-3 documentation.) 62/143 Doc ID 018932 Rev 8 M24LR16E-R 15 Data storage format identifier (DSFID) Data storage format identifier (DSFID) The data storage format identifier indicates how the data is structured in the M24LR16E-R memory. The logical organization of data can be known instantly using the DSFID. It can be programmed and locked using the Write DSFID and Lock DSFID commands. 15.1 CRC The CRC used in the M24LR16E-R is calculated as per the definition in ISO/IEC 13239. The initial register contents are all ones: “FFFF”. The two-byte CRC is appended to each request and response, within each frame, before the EOF. The CRC is calculated on all the bytes after the SOF up to the CRC field. Upon reception of a request from the VCD, the M24LR16E-R verifies that the CRC value is valid. If it is invalid, the M24LR16E-R discards the frame and does not answer to the VCD. Upon reception of a response from the M24LR16E-R, it is recommended that the VCD verifies whether the CRC value is valid. If it is invalid, actions to be performed are left to the discretion of the VCD designer. The CRC is transmitted least significant byte first. Each byte is transmitted least significant bit first. Table 22. CRC transmission rules LSByte MSByte LSBit MSBit LSBit MSBit CRC 16 (8 bits) Doc ID 018932 Rev 8 CRC 16 (8 bits) 63/143 M24LR16E-R protocol description 16 M24LR16E-R M24LR16E-R protocol description The transmission protocol (or simply “the protocol”) defines the mechanism used to exchange instructions and data between the VCD and the M24LR16E-R in both directions. It is based on the concept of “VCD talks first”. This means that an M24LR16E-R does not start transmitting unless it has received and properly decoded an instruction sent by the VCD. The protocol is based on an exchange of: ● a request from the VCD to the M24LR16E-R, ● a response from the M24LR16E-R to the VCD. Each request and each response are contained in a frame. The frame delimiters (SOF, EOF) are described in Section 12. Each request consists of: ● a request SOF (see Figure 20 and Figure 21), ● flags, ● a command code, ● parameters depending on the command, ● application data, ● a 2-byte CRC, ● a request EOF (see Figure 22). Each response consists of: ● an answer SOF (see Figure 35 to Figure 40), ● flags, ● parameters depending on the command, ● application data, ● a 2-byte CRC, ● an answer EOF (see Figure 41 to Figure 46). The protocol is bit-oriented. The number of bits transmitted in a frame is a multiple of eight (8), that is an integer number of bytes. A single-byte field is transmitted least significant bit (LSBit) first. A multiple-byte field is transmitted least significant byte (LSByte) first and each byte is transmitted least significant bit (LSBit) first. The setting of the flags indicates the presence of the optional fields. When the flag is set (to one), the field is present. When the flag is reset (to zero), the field is absent. Table 23. VCD request frame format Request SOF Request_flags Table 24. Response SOF 64/143 Command code Parameters Data 2-byte CRC Request EOF M24LR16E-R Response frame format Response_flags Parameters Doc ID 018932 Rev 8 Data 2-byte CRC Response EOF M24LR16E-R M24LR16E-R protocol description Figure 48. M24LR16E-R protocol timing VCD Request frame (Table 23) Request frame (Table 23) Response frame (Table 24) M24LR16 E-R Timing <-t1-> Response frame (Table 24) <-t2-> Doc ID 018932 Rev 8 <-t1-> <-t2-> 65/143 M24LR16E-R states 17 M24LR16E-R M24LR16E-R states An M24LR16E-R can be in one of four states: ● Power-off ● Ready ● Quiet ● Selected Transitions between these states are specified in Figure 49 and Table 25. 17.1 Power-off state The M24LR16E-R is in the Power-off state when it does not receive enough energy from the VCD. 17.2 Ready state The M24LR16E-R is in the Ready state when it receives enough energy from the VCD. When in the Ready state, the M24LR16E-R answers any request where the Select_flag is not set. 17.3 Quiet state When in the Quiet state, the M24LR16E-R answers any request except for Inventory requests with the Address_flag set. 17.4 Selected state In the Selected state, the M24LR16E-R answers any request in all modes (see Section 18): 66/143 ● Request in Select mode with the Select_flag set ● Request in Addressed mode if the UID matches ● Request in Non-Addressed mode as it is the mode for general requests Doc ID 018932 Rev 8 M24LR16E-R M24LR16E-R states Table 25. M24LR16E-R response depending on Request_flags Address_flag Flags 1 Addressed 0 Non addressed M24LR16E-R in Ready or Selected state (Devices in Quiet state do not answer) X M24LR16E-R in Selected state X M24LR16E-R in Ready, Quiet or Selected state (the device which matches the UID) X Error (03h) X Select_flag 1 Selected 0 Non selected X X X X Figure 49. M24LR16E-R state transition diagram Power-off In field Out of field after tRF_OFF Any other Command where Select_Flag is not set Ready (U iet qu ay St y ad re o tt se Re Out of RF field after tRF_OFF e er r ) ID wh o y et D) (U ad s UI ct le re is t o ag en Se t t Fl er se ct_ diff Re ele ect( S el S ID ) Out of RF field after tRF_OFF Select (UID) Quiet Stay quiet(UID) Any other command where the Address_Flag is set AND where Inventory_Flag is not set Selected Any other command AI06681b 1. The M24LR16E-R returns to the Power Off state if the tag is out of the RF field for at least tRF_OFF. Please refer to application note AN4125 for more information. 2. The intention of the state transition method is that only one M24LR16E-R should be in the Selected state at a time. Doc ID 018932 Rev 8 67/143 Modes 18 M24LR16E-R Modes The term “mode” refers to the mechanism used in a request to specify the set of M24LR16E-Rs that answers the request. 18.1 Addressed mode When the Address_flag is set to 1 (Addressed mode), the request contains the Unique ID (UID) of the addressed M24LR16E-R. Any M24LR16E-R that receives a request with the Address_flag set to 1 compares the received Unique ID to its own. If it matches, then the M24LR16E-R executes the request (if possible) and returns a response to the VCD as specified in the command description. If the UID does not match, then it remains silent. 18.2 Non-addressed mode (general request) When the Address_flag is cleared to 0 (Non-Addressed mode), the request does not contain a Unique ID. Any M24LR16E-R receiving a request with the Address_flag cleared to 0 executes it and returns a response to the VCD as specified in the command description. 18.3 Select mode When the Select_flag is set to 1 (Select mode), the request does not contain an M24LR16ER Unique ID. The M24LR16E-R in the Selected state that receives a request with the Select_flag set to 1 executes it and returns a response to the VCD as specified in the command description. Only M24LR16E-Rs in the Selected state answer a request where the Select_flag set to 1. The system design ensures in theory that only one M24LR16E-R can be in the Select state at a time. 68/143 Doc ID 018932 Rev 8 M24LR16E-R 19 Request format Request format The request consists of: ● an SOF, ● flags, ● a command code, ● parameters and data, ● a CRC, ● an EOF. Table 26. S O F 19.1 General request format Request_flags Command code Parameters Data CRC E O F Request flags In a request, the “flags” field specifies the actions to be performed by the M24LR16E-R and whether corresponding fields are present or not. The flags field consists of eight bits. Bit 3 (Inventory_flag) of the request flag defines the contents of the four MSBs (bits 5 to 8). When bit 3 is reset (0), bits 5 to 8 define the M24LR16E-R selection criteria. When bit 3 is set (1), bits 5 to 8 define the M24LR16E-R Inventory parameters. Table 27. Bit No Bit 1 Bit 2 Bit 3 Bit 4 Definition of request flags 1 to 4 Flag Subcarrier_flag Level (1) Data_rate_flag(2) Description 0 A single subcarrier frequency is used by the M24LR16E-R 1 Two subcarrier are used by the M24LR16E-R 0 Low data rate is used 1 High data rate is used 0 The meaning of flags 5 to 8 is described in Table 28 1 The meaning of flags 5 to 8 is described in Table 29 0 No Protocol format extension 1 Protocol format extension Inventory_flag Protocol_extension_flag(3) 1. Subcarrier_flag refers to the M24LR16E-R-to-VCD communication. 2. Data_rate_flag refers to the M24LR16E-R-to-VCD communication. 3. Protocol_extension_flag must be set to 1 for commands: Read Single Block, Read Multiple Block, Fast Read Multiple Block, Write Single Block, Get Multiple Block Security Status. Command Get System Info supports two options: a standard response format when Protocol_extension_flag is set to 0, and a rich response when protocol extension is set to 1. Doc ID 018932 Rev 8 69/143 Request format M24LR16E-R . Table 28. Request flags 5 to 8 when Bit 3 = 0 Bit No Flag Bit 5 Select flag(1) Bit 6 Level Description 0 Request is executed by any M24LR16E-R according to the setting of Address_flag 1 Request is executed only by the M24LR16E-R in Selected state 0 Request is not addressed. UID field is not present. The request is executed by all M24LR16E-Rs. 1 Request is addressed. UID field is present. The request is executed only by the M24LR16E-R whose UID matches the UID specified in the request. 0 Option not activated. 1 Option activated. Address flag(1) Bit 7 Bit 8 Option flag RFU 0 1. If the Select_flag is set to 1, the Address_flag is set to 0 and the UID field is not present in the request. Table 29. Bit No Flag Bit 5 AFI flag Bit 6 70/143 Request flags 5 to 8 when Bit 3 = 1 Level Description 0 AFI field is not present 1 AFI field is present 0 16 slots 1 1 slot Nb_slots flag Bit 7 Option flag 0 Bit 8 RFU 0 Doc ID 018932 Rev 8 M24LR16E-R 20 Response format Response format The response consists of: ● an SOF, ● flags, ● parameters and data, ● a CRC, ● an EOF. Table 30. S O F 20.1 General response format Response_flags Parameters Data CRC E O F Response flags In a response, the flags indicate how actions have been performed by the M24LR16E-R and whether corresponding fields are present or not. The response flags consist of eight bits. Table 31. Definitions of response flags 1 to 8 Bit No Bit 1 Flag Level Description 0 No error 1 Error detected. Error code is in the “Error” field. Error_flag Bit 2 RFU 0 Bit 3 RFU 0 Bit 4 Extension flag 0 Bit 5 RFU 0 Bit 6 RFU 0 Bit 7 RFU 0 Bit 8 RFU 0 No extension Doc ID 018932 Rev 8 71/143 Response format 20.2 M24LR16E-R Response error code If the Error_flag is set by the M24LR16E-R in the response, the Error code field is present and provides information about the error that occurred. Error codes not specified in Table 32 are reserved for future use. Table 32. Response error code definition Error code 72/143 Meaning 03h The option is not supported. 0Fh Error with no information given. 10h The specified block is not available. 11h The specified block is already locked and thus cannot be locked again. 12h The specified block is locked and its contents cannot be changed. 13h The specified block was not successfully programmed. 14h The specified block was not successfully locked. 15h The specified block is read-protected. Doc ID 018932 Rev 8 M24LR16E-R 21 Anticollision Anticollision The purpose of the anticollision sequence is to inventory the M24LR16E-Rs present in the VCD field using their unique ID (UID). The VCD is the master of communications with one or several M24LR16E-Rs. It initiates M24LR16E-R communication by issuing the Inventory request. The M24LR16E-R sends its response in the determined slot or does not respond. 21.1 Request parameters When issuing the Inventory Command, the VCD: ● sets the Nb_slots_flag as desired, ● adds the mask length and the mask value after the command field. ● The mask length is the number of significant bits of the mask value. ● The mask value is contained in an integer number of bytes. The mask length indicates the number of significant bits. LSB is transmitted first. ● If the mask length is not a multiple of 8 (bits), as many 0-bits as required are added to the mask value MSB so that the mask value is contained in an integer number of bytes. ● The next field starts at the next byte boundary. Table 33. Inventory request format MSB SOF LSB Request_ Command flags 8 bits 8 bits Optional AFI Mask length Mask value CRC 8 bits 8 bits 0 to 8 bytes 16 bits EOF In the example provided in Table 34 and Figure 50, the mask length is 11 bits. Five 0-bits are added to the mask value MSB. The 11-bit mask and the current slot number are compared to the UID. Table 34. Example of the addition of 0-bits to an 11-bit mask value (b15) MSB LSB (b0) 0000 0 100 1100 1111 0-bits added 11-bit mask value Doc ID 018932 Rev 8 73/143 Anticollision M24LR16E-R Figure 50. Principle of comparison between the mask, the slot number and the UID MSB LSB 0000 0100 1100 1111 b 16 bits Mask value received in the Inventory command MSB LSB 100 1100 1111 b 11 bits The Mask value less the padding 0s is loaded into the Tag comparator MSB LSB xxxx The Slot counter is calculated Nb_slots_flags = 0 (16 slots), Slot Counter is 4 bits The Slot counter is concatened to the Mask value Nb_slots_flags = 0 The concatenated result is compared with the least significant bits of the Tag UID. 4 bits MSB LSB xxxx 100 1100 1111 b 15 bits UID b63 b0 xxxx xxxx ..... xxxx xxxx x xxx xxxx xxxx xxxx b Bits ignored 64 bits Compare AI06682 The AFI field is present if the AFI_flag is set. The pulse is generated according to the definition of the EOF in ISO/IEC 15693-2. The first slot starts immediately after the request EOF is received. To switch to the next slot, the VCD sends an EOF. The following rules and restrictions apply: 74/143 ● If no M24LR16E-R answer is detected, the VCD may switch to the next slot by sending an EOF. ● If one or more M24LR16E-R answers are detected, the VCD waits until the complete frame has been received before sending an EOF for switching to the next slot. Doc ID 018932 Rev 8 M24LR16E-R 22 Request processing by the M24LR16E-R Request processing by the M24LR16E-R Upon reception of a valid request, the M24LR16E-R performs the following algorithm: ● NbS is the total number of slots (1 or 16) ● SN is the current slot number (0 to 15) ● LSB (value, n) function returns the n Less Significant Bits of value ● MSB (value, n) function returns the n Most Significant Bits of value ● “&” is the concatenation operator ● Slot_Frame is either an SOF or an EOF SN = 0 if (Nb_slots_flag) then NbS = 1 SN_length = 0 endif else NbS = 16 SN_length = 4 endif label1: if LSB(UID, SN_length + Mask_length) = LSB(SN,SN_length)&LSB(Mask,Mask_length) then answer to inventory request endif wait (Slot_Frame) if Slot_Frame = SOF then Stop Anticollision decode/process request exit endif if Slot_Frame = EOF if SN < NbS-1 then SN = SN + 1 goto label1 exit endif endif Doc ID 018932 Rev 8 75/143 Explanation of the possible cases 23 M24LR16E-R Explanation of the possible cases Figure 51 summarizes the main possible cases that can occur during an anticollision sequence when the number of slots is 16. The sequence of steps is as follows: Note: 76/143 ● The VCD sends an Inventory request, in a frame terminated by an EOF. The number of slots is 16. ● M24LR16E-R_1 transmits its response in Slot 0. It is the only one to do so, therefore no collision occurs and its UID is received and registered by the VCD. ● The VCD sends an EOF in order to switch to the next slot. ● In Slot 1, two M24LR16E-Rs, M24LR16E-R_2 and M24LR16E-R_3 transmit a response, thus generating a collision. The VCD records the event and registers that a collision was detected in Slot 1. ● The VCD sends an EOF in order to switch to the next slot. ● In Slot 2, no M24LR16E-R transmits a response. Therefore the VCD does not detect any M24LR16E-R SOF and switches to the next slot by sending an EOF. ● In Slot 3, another collision occurs due to responses from M24LR16E-R_4 and M24LR16E-R_5. ● The VCD sends a request (for instance a Read Block) to M24LR16E-R_1 whose UID has already been correctly received. ● All M24LR16E-Rs detect an SOF and exit the anticollision sequence. They process this request and since the request is addressed to M24LR16E-R_1, only M24LR16E-R_1 transmits a response. ● All M24LR16E-Rs are ready to receive another request. If it is an Inventory command, the slot numbering sequence restarts from 0. The decision to interrupt the anticollision sequence is made by the VCD. It could have continued to send EOFs until Slot 16 and only then sent the request to M24LR16E-R_1. Doc ID 018932 Rev 8 SOF Inventory EOF Request Slot 2 EOF EOF Slot 3 EOF SOF Response 2 Request to EOF M24RF64_1 Response 4 Response from M24RF64_1 M24RF64s Response 1 Comment t1 t2 No collision t1 Response 5 t2 Collision t3 No Response t1 t2 t1 Collision Time AI15117 77/143 Explanation of the possible cases Timing Response 3 M24LR16E-R Doc ID 018932 Rev 8 VCD Slot 1 Figure 51. Description of a possible anticollision sequence Slot 0 Inventory Initiated command 24 M24LR16E-R Inventory Initiated command The M24LR16E-R provides a special feature to improve the inventory time response of moving tags using the Initiate_flag value. This flag, controlled by the Initiate command, allows tags to answer to Inventory Initiated commands. For applications in which multiple tags are moving in front of a reader, it is possible to miss tags using the standard inventory command. The reason is that the inventory sequence has to be performed on a global tree search. For example, a tag with a particular UID value may have to wait the run of a long tree search before being inventoried. If the delay is too long, the tag may be out of the field before it has been detected. Using the Initiate command, the inventory sequence is optimized. When multiple tags are moving in front of a reader, the ones which are within the reader field are initiated by the Initiate command. In this case, a small batch of tags answers to the Inventory Initiated command, which optimizes the time necessary to identify all the tags. When finished, the reader has to issue a new Initiate command in order to initiate a new small batch of tags which are new inside the reader field. It is also possible to reduce the inventory sequence time using the Fast Initiate and Fast Inventory Initiated commands. These commands allow the M24LR16E-Rs to increase their response data rate by a factor of 2, up to 53 Kbit/s. 78/143 Doc ID 018932 Rev 8 M24LR16E-R Timing definition 25 Timing definition 25.1 t1: M24LR16E-R response delay Upon detection of the rising edge of the EOF received from the VCD, the M24LR16E-R waits for a time t1nom before transmitting its response to a VCD request or switching to the next slot during an inventory process. Values of t1 are given in Table 35. The EOF is defined in Figure 22. 25.2 t2: VCD new request delay t2 is the time after which the VCD may send an EOF to switch to the next slot when one or more M24LR16E-R responses have been received during an Inventory command. It starts from the reception of the EOF from the M24LR16E-Rs. The EOF sent by the VCD may be either 10% or 100% modulated regardless of the modulation index used for transmitting the VCD request to the M24LR16E-R. t2 is also the time after which the VCD may send a new request to the M24LR16E-R, as described in Figure 48. Values of t2 are given in Table 35. 25.3 t3: VCD new request delay when no response is received from the M24LR16E-R t3 is the time after which the VCD may send an EOF to switch to the next slot when no M24LR16E-R response has been received. The EOF sent by the VCD may be either 10% or 100% modulated regardless of the modulation index used for transmitting the VCD request to the M24LR16E-R. From the time the VCD has generated the rising edge of an EOF: ● If this EOF is 100% modulated, the VCD waits for a time at least equal to t3min before sending a new EOF. ● If this EOF is 10% modulated, the VCD waits for a time at least equal to the sum of t3min + the M24LR16E-R nominal response time (which depends on the M24LR16E-R data rate and subcarrier modulation mode) before sending a new EOF. Table 35. Timing values(1) Minimum (min) values Nominal (nom) values Maximum (max) values t1 318.6 µs 320.9 µs 323.3 µs t2 309.2 µs No tnom No tmax No tnom No tmax t3 t1max (2) + tSOF(3) 1. The tolerance of specific timings is ± 32/fC. 2. t1max does not apply for write-alike requests. Timing conditions for write-alike requests are defined in the command description. 3. tSOF is the time taken by the M24LR16E-R to transmit an SOF to the VCD. tSOF depends on the current data rate: High data rate or Low data rate. Doc ID 018932 Rev 8 79/143 Command codes 26 M24LR16E-R Command codes The M24LR16E-R supports the commands described in this section. Their codes are given in Table 36. Table 36. Command codes Command code standard 80/143 Function Command code custom Function 01h Inventory 2Ch Get Multiple Block Security Status 02h Stay Quiet B1h Write-sector Password 20h Read Single Block B2h Lock-sector 21h Write Single Block B3h Present-sector Password 23h Read Multiple Block C0h Fast Read Single Block 25h Select C1h Fast Inventory Initiated 26h Reset to Ready C2h Fast Initiate 27h Write AFI C3h Fast Read Multiple Block 28h Lock AFI D1h Inventory Initiated 29h Write DSFID D2h Initiate 2Ah Lock DSFID A0h ReadCfg 2Bh Get System Info A1h WriteEHCfg A2h SetRstEHEn A3h CheckEHEn A4h WriteDOCfg Doc ID 018932 Rev 8 M24LR16E-R 26.1 Command codes Inventory When receiving the Inventory request, the M24LR16E-R runs the anticollision sequence. The Inventory_flag is set to 1. The meaning of flags 5 to 8 is shown in Table 29. The request contains: ● the flags, ● the Inventory command code (see Table 36), ● the AFI if the AFI flag is set, ● the mask length, ● the mask value, ● the CRC. The M24LR16E-R does not generate any answer in case of error. Table 37. Inventory request format Request Request_flags Inventory SOF Optional AFI Mask length Mask value CRC16 8 bits 8 bits 8 bits 0 - 64 bits 16 bits 01h Request EOF The response contains: ● the flags, ● the Unique ID. Table 38. Inventory response format Response Response_ SOF flags 8 bits DSFID UID CRC16 8 bits 64 bits 16 bits Response EOF During an Inventory process, if the VCD does not receive an RF M24LR16E-R response, it waits for a time t3 before sending an EOF to switch to the next slot. t3 starts from the rising edge of the request EOF sent by the VCD. ● If the VCD sends a 100% modulated EOF, the minimum value of t3 is: t3min = 4384/fC (323.3µs) + tSOF ● If the VCD sends a 10% modulated EOF, the minimum value of t3 is: t3min = 4384/fC (323.3µs) + tNRT where: ● tSOF is the time required by the M24LR16E-R to transmit an SOF to the VCD, ● tNRT is the nominal response time of the M24LR16E-R. tNRT and tSOF are dependent on the M24LR16E-R-to-VCD data rate and subcarrier modulation mode. When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF starting the inventory command to the end of the M24LR16E-R response. If the M24LR16ER does not receive the corresponding slot marker, the RF WIP/BUSY pin remains at 0 until the next RF power-off. Doc ID 018932 Rev 8 81/143 Command codes M24LR16E-R When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. Figure 52. M24LR16 RF-Busy management following Inventory command 1) M24LR16 replies in slot n. RF_Busy is released after M24LR16 response. Slot 1 S Inventory E O O F command F Slot n E O F E O F E O F S E Ireply O O F M24LR16 F RF_Busy 2) Slot n never occurs. RF_Busy is only released by Power-off. Slot 1 S Inventory E O O F command F Slot n E O F Power-off E O F RF_Busy 3) VCD sends a Valid command before slot n. RF_Busy is released after M24LR16 response. Slot 1 S Inventory E O O F command F E O F S E INew O O F command F S Ireply O M24LR16 F E O F RF_Busy 4) VCD sends a Bad command before slot n. RF_Busy is released after VCD command. Slot 1 S Inventory E O O F command F E O F S E INew O O command F F RF_Busy MS19754V1 82/143 Doc ID 018932 Rev 8 M24LR16E-R 26.2 Command codes Stay Quiet Command code = 0x02 On receiving the Stay Quiet command, the M24LR16E-R enters the Quiet State if no error occurs, and does NOT send back a response. There is NO response to the Stay Quiet command even if an error occurs. When in the Quiet state: ● the M24LR16E-R does not process any request if the Inventory_flag is set, ● the M24LR16E-R processes any Addressed request. The M24LR16E-R exits the Quiet State when: ● it is reset (power off), ● receiving a Select request. It then goes to the Selected state, ● receiving a Reset to Ready request. It then goes to the Ready state. Table 39. Request SOF Stay Quiet request format Request flags Stay Quiet UID CRC16 8 bits 02h 64 bits 16 bits Request EOF The Stay Quiet command must always be executed in Addressed mode (Select_flag is reset to 0 and Address_flag is set to 1). Figure 53. Stay Quiet frame exchange between VCD and M24LR16E-R VCD SOF Stay Quiet request EOF M24LR16E-R Timing When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 during the Stay Quiet command. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. Doc ID 018932 Rev 8 83/143 Command codes 26.3 M24LR16E-R Read Single Block On receiving the Read Single Block command, the M24LR16E-R reads the requested block and sends back its 32-bit value in the response. The Protocol_extension_flag should be set to 1 for the M24LR16E-R to operate correctly. If the Protocol_extension_flag is at 0, the M24LR16E-R answers with an error code. The Option_flag is supported. Table 40. Read Single Block request format Request Request_ Read Single SOF flags Block 8 bits 20h UID(1) Block number CRC16 64 bits 16 bits 16 bits Request EOF 1. Gray means that the field is optional. Request parameters: ● Request flags ● UID (optional) ● Block number Table 41. Read Single Block response format when Error_flag is NOT set Response SOF Response_flags Sector security status(1) Data CRC16 8 bits 8 bits 32 bits 16 bits Response EOF 1. Gray means that the field is optional. Response parameters: ● Sector security status if Option_flag is set (see Table 42) ● Four bytes of block data Table 42. b7 Sector security status b6 b5 Reserved for future use. All at 0. Table 43. b4 b3 Password control bits b2 Read / Write protection bits 0: Current sector not locked 1: Current sector locked Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response parameter: 84/143 b0 Read Single Block response format when Error_flag is set Response SOF ● b1 Error code as Error_flag is set – 10h: the specified block is not available – 15h: the specified block is read-protected Doc ID 018932 Rev 8 Response EOF M24LR16E-R Command codes Figure 54. Read Single Block frame exchange between VCD and M24LR16E-R VCD Read Single Block request SOF EOF M24LR16E-R <-t1-> SOF Read Single Block response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Read Single Block command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. 26.4 Write Single Block On receiving the Write Single Block command, the M24LR16E-R writes the data contained in the request to the requested block and reports whether the write operation was successful in the response. The Protocol_extension_flag should be set to 1 for the M24LR16E-R to operate correctly. If the Protocol_extension_flag is at 0, the M24LR16E-R answers with an error code. The Option_flag is supported. During the RF write cycle Wt, there should be no modulation (neither 100% nor 10%), otherwise, the M24LR16E-R may not program correctly the data into the memory. The Wt time is equal to t1nom + 18 × 302 µs. Table 44. Write Single Block request format Request Request_ SOF flags Write Single Block UID(1) Block number Data CRC16 21h 64 bits 16 bits 32 bits 16 bits 8 bits Request EOF 1. Gray means that the field is optional. Request parameters: ● Request flags ● UID (optional) ● Block number ● Data Table 45. Write Single Block response format when Error_flag is NOT set Response SOF Response_flags CRC16 8 bits 16 bits Response EOF Response parameter: ● No parameter. The response is send back after the writing cycle. Doc ID 018932 Rev 8 85/143 Command codes M24LR16E-R Table 46. Write Single Block response format when Error_flag is set Response SOF Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set: – 0Fh: error with no information given – 10h: the specified block is not available – 12h: the specified block is locked and its contents cannot be changed – 13h: the specified block was not successfully programmed Figure 55. Write Single Block frame exchange between VCD and M24LR16E-R VCD SOF Write Single Block request EOF Write Single Block response M24LR16ER <-t1-> SOF M24LR16ER <------------------- Wt ---------------> SOF EOF Write sequence when error Write Single Block response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Write Single Block command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin is tied to 0 for the duration of the internal write cycle (from the end of a valid write single block command to the beginning of the M24LR16E-R response). 86/143 Doc ID 018932 Rev 8 M24LR16E-R Command codes Figure 56. M24LR16 RF-Busy management following Write command 1) M24LR16 replies. RF_Busy is released after M24LR16 response. Wt S E Write O O F command F S E Ireply O O F M24LR16 F RF_Busy 2) M24LR16 replies when option flag is set. RF_Busy is released after M24LR16 response. Wt S E Write O O command F F E O F t1 S E Ireply O O M24LR16 F F RF_Busy 3) VCD sends a forbidden Write (sector lock, password-protected). RF_Busy is released after M24LR16 command. S E Write O O command F F t1 S E Ireply O O M24LR16 F F RF_Busy MS19756V1 Doc ID 018932 Rev 8 87/143 Command codes M24LR16E-R When configuring in the RF Write in progress mode, the RF WIP/BUSY pin is tied to 0 during the Write & verify sequence, as shown in Figure 57. Figure 57. M24LR16 RF-Wip management following Write command 1) M24LR16 replies. RF_Wip is released after M24LR16 response. Wt S E Write O O command F F S E Ireply O O M24LR16 F F RF_Wip 2) M24LR16 replies when option flag is set. RF_Wip is released after M24LR16 response. Wt S E Write O O F command F E O F t1 S E Ireply O O F M24LR16 F RF_Wip 3) VCD sends a forbidden Write (sector lock, password-protected). RF_Wip is released after M24LR16 command. S E Write O O F command F t1 S E Ireply O O F M24LR16 F RF_Wip MS19762V1 88/143 Doc ID 018932 Rev 8 M24LR16E-R 26.5 Command codes Read Multiple Block When receiving the Read Multiple Block command, the M24LR16E-R reads the selected blocks and sends back their value in multiples of 32 bits in the response. The blocks are numbered from 00h to 1FFh in the request and the value is minus one (–1) in the field. For example, if the “Number of blocks” field contains the value 06h, seven blocks are read. The maximum number of blocks is fixed at 32 assuming that they are all located in the same sector. If the number of blocks overlaps sectors, the M24LR16E-R returns an error code. The Protocol_extension_flag should be set to 1 for the M24LR16E-R to operate correctly. If the Protocol_extension_flag is at 0, the M24LR16E-R answers with an error code. The Option_flag is supported. Table 47. Read Multiple Block request format Read Request Request_ Multiple SOF flags Block UID(1) First block number Number of blocks CRC16 8 bits 64 bits 16 bits 8 bits 16 bits 23h Request EOF 1. Gray means that the field is optional. Request parameters: ● Request flags ● UID (optional) ● First block number ● Number of blocks Table 48. Read Multiple Block response format when Error_flag is NOT set Response Response_ SOF flags 8 bits Sector security status(1) Data CRC16 8 bits(2) 32 bits(2) 16 bits Response EOF 1. Gray means that the field is optional. 2. Repeated as needed. Response parameters: ● Sector security status if Option_flag is set (see Table 49) ● N blocks of data Table 49. b7 Sector security status b6 b5 Reserved for future use. All at 0. b4 b3 Password control bits b2 b1 Read / Write protection bits Doc ID 018932 Rev 8 b0 0: Current sector not locked 1: Current sector locked 89/143 Command codes M24LR16E-R Table 50. Read Multiple Block response format when Error_flag is set Response SOF Response_flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set: – 0Fh: error with no information given – 10h: the specified block is not available – 15h: the specified block is read-protected Figure 58. Read Multiple Block frame exchange between VCD and M24LR16E-R VCD SOF Read Multiple EOF Block request M24LR16E-R <-t1-> SOF Read Multiple EOF Block response When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Read Multiple Block command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. 26.6 Select When receiving the Select command: ● If the UID is equal to its own UID, the M24LR16E-R enters or stays in the Selected state and sends a response. ● If the UID does not match its own, the selected M24LR16E-R returns to the Ready state and does not send a response. The M24LR16E-R answers an error code only if the UID is equal to its own UID. If not, no response is generated. If an error occurs, the M24LR16E-R remains in its current state. Table 51. Select request format Request Request_ SOF flags 8 bits Select UID CRC16 25h 64 bits 16 bits Request parameter: ● 90/143 UID Doc ID 018932 Rev 8 Request EOF M24LR16E-R Command codes Table 52. Select Block response format when Error_flag is NOT set Response SOF Response_flags CRC16 8 bits 16 bits Response EOF Response parameter: ● No parameter Table 53. Select response format when Error_flag is set Response SOF Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set: – 03h: the option is not supported Figure 59. Select frame exchange between VCD and M24LR16E-R VCD M24LR16E-R SOF Select request EOF <-t1-> SOF Select response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Select command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. Doc ID 018932 Rev 8 91/143 Command codes 26.7 M24LR16E-R Reset to Ready On receiving a Reset to Ready command, the M24LR16E-R returns to the Ready state if no error occurs. In the Addressed mode, the M24LR16E-R answers an error code only if the UID is equal to its own UID. If not, no response is generated. Table 54. Reset to Ready request format Request Request_ Reset to SOF flags Ready UID(1) CRC16 8 bits 64 bits 16 bits 26h Request EOF 1. Gray means that the field is optional. Request parameter: ● UID (optional) Table 55. Reset to Ready response format when Error_flag is NOT set Response SOF Response_flags CRC16 8 bits 16 bits Response EOF Response parameter: ● No parameter Table 56. Reset to ready response format when Error_flag is set Response Response_flags SOF Error code CRC16 8 bits 16 bits 8 bits Response EOF Response parameter: ● Error code as Error_flag is set: – 03h: the option is not supported Figure 60. Reset to Ready frame exchange between VCD and M24LR16E-R VCD M24LR16E-R 92/143 SOF Reset to Ready request EOF <-t1-> Doc ID 018932 Rev 8 SOF Reset to Ready response EOF M24LR16E-R Command codes When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Reset to ready command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. 26.8 Write AFI On receiving the Write AFI request, the M24LR16E-R programs the 8-bit AFI value to its memory. The Option_flag is supported. During the RF write cycle Wt, there should be no modulation (neither 100% nor 10%), otherwise, the M24LR16E-R may not write correctly the AFI value into the memory. The Wt time is equal to t1nom + 18 × 302 µs. Table 57. Write AFI request format Request Request Write SOF _flags AFI 8 bits 27h UID(1) AFI CRC16 64 bits 8 bits 16 bits Request EOF 1. Gray means that the field is optional. Request parameter: ● Request flags ● UID (optional) ● AFI Table 58. Write AFI response format when Error_flag is NOT set Response SOF Response_flags CRC16 8 bits 16 bits Response EOF Response parameter: ● No parameter Table 59. Write AFI response format when Error_flag is set Response SOF Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set – 12h: the specified block is locked and its contents cannot be changed – 13h: the specified block was not successfully programmed Doc ID 018932 Rev 8 93/143 Command codes M24LR16E-R Figure 61. Write AFI frame exchange between VCD and M24LR16E-R VCD SOF Write AFI EOF request M24LR16E-R <-t1-> SOF EOF Write sequence when error M24LR16E-R <------------------ Wt --------------> SOF Write AFI EOF response Write AFI response When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Write AFI command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin is tied to 0 for the duration of the internal write cycle (from the end of a valid Write AFI command to the beginning of the M24LR16E-R response). 26.9 Lock AFI On receiving the Lock AFI request, the M24LR16E-R locks the AFI value permanently. The Option_flag is supported. During the RF write cycle Wt, there should be no modulation (neither 100% nor 10%), otherwise, the M24LR16E-R may not Lock correctly the AFI value in memory. The Wt time is equal to t1nom + 18 × 302 µs. Table 60. Lock AFI request format Request Request_ SOF flags 8 bits Lock AFI UID(1) CRC16 28h 64 bits 16 bits Request EOF 1. Gray means that the field is optional. Request parameter: ● Request Flags ● UID (optional) Table 61. Response SOF Lock AFI response format when Error_flag is NOT set Response_flags CRC16 8 bits 16 bits Response parameter: ● 94/143 No parameter Doc ID 018932 Rev 8 Response EOF M24LR16E-R Command codes Table 62. Lock AFI response format when Error_flag is set Response SOF Response_flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set – 11h: the specified block is already locked and thus cannot be locked again – 14h: the specified block was not successfully locked Figure 62. Lock AFI frame exchange between VCD and M24LR16E-R VCD SOF Lock AFI EOF request Lock AFI response M24LR16E-R <-t1-> SOF M24LR16E-R <----------------- Wt ------------SOF > EOF Lock sequence when error Lock AFI response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Lock AFI command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin is tied to 0 for the entire duration of the internal write cycle (from the end of valid Lock AFI command to the beginning of the M24LR16E-R response). Doc ID 018932 Rev 8 95/143 Command codes 26.10 M24LR16E-R Write DSFID On receiving the Write DSFID request, the M24LR16E-R programs the 8-bit DSFID value to its memory. The Option_flag is supported. During the RF write cycle Wt, there should be no modulation (neither 100% nor 10%), otherwise, the M24LR16E-R may not write correctly the DSFID value in memory. The Wt time is equal to t1nom + 18 × 302 µs. Table 63. Write DSFID request format Request Request_ Write SOF flags DSFID 8 bits 29h UID(1) DSFID CRC16 64 bits 8 bits 16 bits Request EOF 1. Gray means that the field is optional. Request parameter: ● Request flags ● UID (optional) ● DSFID Table 64. Write DSFID response format when Error_flag is NOT set Response SOF Response_flags CRC16 8 bits 16 bits Response EOF Response parameter: ● No parameter Table 65. Write DSFID response format when Error_flag is set Response Response_flags SOF Error code CRC16 8 bits 16 bits 8 bits Response parameter: ● 96/143 Error code as Error_flag is set – 12h: the specified block is locked and its contents cannot be changed – 13h: the specified block was not successfully programmed Doc ID 018932 Rev 8 Response EOF M24LR16E-R Command codes Figure 63. Write DSFID frame exchange between VCD and M24LR16E-R VCD SOF Write DSFID request EO F SO F Write DSFID response EO F Write sequence when error M24LR16E-R <-t1-> M24LR16E-R <---------------- Wt ------------ SO Write DSFID EOF > F response When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Write DSFID command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin is tied to 0 for the duration of the internal write cycle (from the end of a valid Write DSFID command to beginning of the M24LR16E-R response). 26.11 Lock DSFID On receiving the Lock DSFID request, the M24LR16E-R locks the DSFID value permanently. The Option_flag is supported. During the RF write cycle Wt, there should be no modulation (neither 100% nor 10%), otherwise, the M24LR16E-R may not lock correctly the DSFID value in memory. The Wt time is equal to t1nom + 18 × 302 µs. Table 66. Lock DSFID request format Request Request_ SOF flags 8 bits Lock DSFID UID(1) CRC16 2Ah 64 bits 16 bits Request EOF 1. Gray means that the field is optional. Request parameter: ● Request flags ● UID (optional) Table 67. Response SOF Lock DSFID response format when Error_flag is NOT set Response_flags CRC16 8 bits 16 bits Doc ID 018932 Rev 8 Response EOF 97/143 Command codes M24LR16E-R Response parameter: ● No parameter. Table 68. Lock DSFID response format when Error_flag is set Response Response_flags SOF Error code CRC16 8 bits 16 bits 8 bits Response EOF Response parameter: ● Error code as Error_flag is set: – 11h: the specified block is already locked and thus cannot be locked again – 14h: the specified block was not successfully locked . Figure 64. Lock DSFID frame exchange between VCD and M24LR16E-R VCD SOF Lock DSFID request EOF Lock DSFID response M24LR16E-R <-t1-> SOF EOF M24LR16E-R <---------------- Wt -------------> SOF Lock sequence when error Lock DSFID response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Lock DSFID command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin is tied to 0 for the duration of the internal write cycle (from the end of a valid Lock DSFID command to the beginning of the M24LR16E-R response). 98/143 Doc ID 018932 Rev 8 M24LR16E-R 26.12 Command codes Get System Info When receiving the Get System Info command, the M24LR16E-R sends back its information data in the response.The Option_flag is not supported. The Get System Info can be issued in both Addressed and Non Addressed modes. The Protocol_extension_flag can be set to 0 or 1. Table 70 and Table 72 show M24LR16E-R response to the Get System Info command depending on the value of the Protocol_extension_flag. Table 69. Get System Info request format Request Request Get System SOF _flags Info 8 bits 2Bh UID(1) CRC16 64 bits 16 bits Request EOF 1. Gray means that the field is optional. Request parameter: ● Request flags ● UID (optional) Table 70. Response SOF Get System Info response format when Protocol_extension_flag = 0 and Error_flag is NOT set Response _flags Information flags UID DSFID AFI IC ref. CRC16 00h 0Bh 64 bits 8 bits 8 bits 4Eh 16 bits Response EOF Response parameters: ● Information flags set to 0Ch. DSFID, AFI and IC reference fields are present. ● UID code on 64 bits ● DSFID value ● AFI value ● M24LR16E-R IC reference: the 8 bits are significant. Table 71. Response SOF Get System Info response format when Protocol_extension_flag = 1 and Error_flag is NOT set Response Information _flags flags 00h 0Fh UID DSFID 64 bits 8 bits Doc ID 018932 Rev 8 Memory size IC ref. 8 bits 0301FF 4Eh AFI CRC Response 16 EOF 16 bits 99/143 Command codes M24LR16E-R Response parameters: ● Information flags set to 0Fh. DSFID, AFI, Memory Size and IC reference fields are present. ● UID code on 64 bits ● DSFID value ● AFI value ● Memory size. The M24LR16E-R provides 512 blocks (01FFh) of 4 byte (03h) ● IC reference: the 8 bits are significant. Table 72. Get System Info response format when Error_flag is set Response SOF Response_flags Error code CRC16 01h 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set: – 03h: Option not supported . Figure 65. Get System Info frame exchange between VCD and M24LR16E-R VCD M24LR16E-R SOF Get System Info request EOF <-t1-> SOF Get System Info response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Get System Info command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. 100/143 Doc ID 018932 Rev 8 M24LR16E-R 26.13 Command codes Get Multiple Block Security Status When receiving the Get Multiple Block Security Status command, the M24LR16E-R sends back the sector security status. The blocks are numbered from 00h to 01FFh in the request and the value is minus one (–1) in the field. For example, a value of '06' in the “Number of blocks” field requests to return the security status of seven blocks. The Protocol_extension_flag should be set to 1 for the M24LR16E-R to operate correctly. If the Protocol_extension_flag is at 0, the M24LR16E-R answers with an error code. During the M24LR16E-R response, if the internal block address counter reaches 01FFh, it rolls over to 0000h and the Sector Security Status bytes for that location are sent back to the reader. Table 73. Get Multiple Block Security Status request format Request Request SOF _flags Get Multiple Block Security Status UID(1) First block number Number of blocks CRC16 2Ch 64 bits 16 bits 16 bits 16 bits 8 bits Request EOF 1. Gray means that the field is optional. Request parameter: ● Request flags ● UID (optional) ● First block number ● Number of blocks Table 74. Response SOF Get Multiple Block Security Status response format when Error_flag is NOT set Response_ flags Sector security status CRC16 8 bits 8 bits(1) 16 bits Response EOF 1. Repeated as needed. Response parameters: ● Sector security status (see Table 75) Table 75. b7 Sector security status b6 b5 Reserved for future use. All at 0. b4 b3 Password control bits b2 b1 Read / Write protection bits Doc ID 018932 Rev 8 b0 0: Current sector not locked 1: Current sector locked 101/143 Command codes M24LR16E-R Table 76. Get Multiple Block Security Status response format when Error_flag is set Response SOF Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set: – 03h: the option is not supported – 10h: the specified block is not available Figure 66. Get Multiple Block Security Status frame exchange between VCD and M24LR16E-R VCD SOF Get Multiple Block EOF Security Status M24LR16E-R <-t1-> SOF Get Multiple Block Security Status EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Get Multiple Block Security Status command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. 26.14 Write-sector Password On receiving the Write-sector Password command, the M24LR16E-R uses the data contained in the request to write the password and reports whether the operation was successful in the response. The Option_flag is supported. During the RF write cycle time, Wt, there must be no modulation at all (neither 100% nor 10%), otherwise, the M24LR16E-R may not correctly program the data into the memory. The Wt time is equal to t1nom + 18 × 302 µs. After a successful write, the new value of the selected password is automatically activated. It is not required to present the new password value until M24LR16E-R power-down. Table 77. Request SOF Write-sector Password request format Request _flags Writesector password IC Mfg code UID(1) Password number Data CRC16 8 bits B1h 02h 64 bits 8 bits 32 bits 16 bits 1. Gray means that the field is optional. 102/143 Doc ID 018932 Rev 8 Request EOF M24LR16E-R Command codes Request parameter: ● Request flags ● UID (optional) ● Password number (01h = Pswd1, 02h = Pswd2, 03h = Pswd3, other = Error) ● Data Table 78. Write-sector Password response format when Error_flag is NOT set Response SOF Response_flags CRC16 8 bits 16 bits Response EOF Response parameter: ● no parameter. Table 79. Write-sector Password response format when Error_flag is set Response SOF Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set: – 10h: the password number is incorrect – 12h: the session was not opened before the password update – 13h: the specified block was not successfully programmed – 0Fh: the presented password is incorrect . Figure 67. Write-sector Password frame exchange between VCD and M24LR16E-R VCD M24LR16E-R M24LR16E-R SOF Writesector Password request EOF <-t1-> SOF Write-sector Password response EOF <---------------- Wt -------------> SOF Doc ID 018932 Rev 8 Write sequence when error Writesector Password response EOF 103/143 Command codes M24LR16E-R When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Write-sector Password command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin is tied to 0 for the duration of the internal write cycle (from the end of a valid Write sector password command to the beginning of the M24LR16E-R response). 26.15 Lock-sector On receiving the Lock-sector command, the M24LR16E-R sets the access rights and permanently locks the selected sector. The Option_flag is supported. A sector is selected by giving the address of one of its blocks in the Lock-sector request (Sector number field). For example, addresses 0 to 31 are used to select sector 0 and addresses 32 to 63 are used to select sector 1. Care must be taken when issuing the Locksector command as all the blocks belonging to the same sector are automatically locked by a single command. The Protocol_extension_flag should be set to 1 for the M24LR16E-R to operate correctly. If the Protocol_extension_flag is at 0, the M24LR16E-R answers with an error code. During the RF write cycle Wt, there should be no modulation (neither 100% nor 10%), otherwise, the M24LR16E-R may not correctly lock the memory block. The Wt time is equal to t1nom + 18 × 302 µs. Table 80. Request SOF Lock-sector request format Request _flags Locksector IC Mfg code UID(1) Sector number Sector security status CRC16 8 bits B2h 02h 64 bits 16 bits 8 bits 16 bits Request EOF 1. Gray means that the field is optional. Request parameters: ● Request flags ● (optional) UID ● Sector number ● Sector security status (refer to Table 81) Table 81. b7 b6 b5 0 0 0 Table 82. Response SOF 104/143 Sector security status b4 b3 password control bits b2 b1 Read / Write protection bits b0 1 Lock-sector response format when Error_flag is NOT set Response_flags CRC16 8 bits 16 bits Doc ID 018932 Rev 8 Response EOF M24LR16E-R Command codes Response parameter: ● No parameter Table 83. Lock-sector response format when Error_flag is set Response SOF Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set: – 10h: the specified block is not available – 11h: the specified block is already locked and thus cannot be locked again – 14h: the specified block was not successfully locked Figure 68. Lock-sector frame exchange between VCD and M24LR16E-R VCD SOF Lock-sector EOF request M24LR16E-R <-t1-> SOF Lock-sector EOF response Lock sequence when error M24LR16E-R <--------------- Wt -----------> SOF Lock-sector EOF response When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Lock-sector command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin is tied to 0 for the duration of the internal write cycle (from the end of a valid Lock sector command to the beginning of the M24LR16E-R response). 26.16 Present-sector Password On receiving the Present-sector Password command, the M24LR16E-R compares the requested password with the data contained in the request and reports whether the operation has been successful in the response. The Option_flag is supported. During the comparison cycle equal to Wt, there should be no modulation (neither 100% nor 10%), otherwise, the M24LR16E-R the Password value may not be correctly compared. The Wt time is equal to t1nom + 18 × 302 µs. After a successful command, the access to all the memory blocks linked to the password is changed as described in Section 4.1: M24LR16E-R block security in RF mode. Doc ID 018932 Rev 8 105/143 Command codes M24LR16E-R Table 84. Present-sector Password request format Request SOF Request _flags Presentsector Password IC Mfg code UID(1) Password number Password CRC16 8 bits B3h 02h 64 bits 8 bits 32 bits 16 bits Request EOF 1. Gray means that the field is optional. Request parameter: ● Request flags ● UID (optional) ● Password Number (0x01 = Pswd1, 0x02 = Pswd2, 0x03 = Pswd3, other = Error) ● Password Table 85. Present-sector Password response format when Error_flag is NOT set Response SOF Response_flags CRC16 8 bits 16 bits Response EOF Response parameter: ● No parameter. The response is send back after the write cycle. Table 86. Present-sector Password response format when Error_flag is set Response SOF Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response parameter: ● 106/143 Error code as Error_flag is set: – 10h: the password number is incorrect – 0Fh: the present password is incorrect Doc ID 018932 Rev 8 Response EOF M24LR16E-R Command codes Figure 69. Present-sector Password frame exchange between VCD and M24LR16E-R VCD M24LR16E-R M24LR16E-R Presentsector password SOF response EOF OR error 0F (bad password) <-t1-> SOF Presentsector password response EOF <---------------- Wt ------------> SOF sequence when error Presentsector password response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Present Sector Password command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY remains in high-Z state. Doc ID 018932 Rev 8 107/143 Command codes 26.17 M24LR16E-R Fast Read Single Block On receiving the Fast Read Single Block command, the M24LR16E-R reads the requested block and sends back its 32-bit value in the response. The Option_flag is supported. The data rate of the response is multiplied by 2. The Protocol_extension_flag should be set to 1 for the M24LR16E-R to operate correctly. If the Protocol_extension_flag is at 0, the M24LR16E-R answers with an error code. The subcarrier_flag should be set to 0, otherwise the M24LR16E-R answers with an error code. Table 87. Fast Read Single Block request format Request Request_ SOF flags Fast Read IC Mfg Single code Block 8 bits C0h 02h UID(1) Block number CRC16 64 bits 16 bits 16 bits Request EOF 1. Gray means that the field is optional. Request parameters: ● Request flags ● UID (optional) ● Block number Table 88. Fast Read Single Block response format when Error_flag is NOT set Response Response SOF _flags Sector security status(1) Data CRC16 8 bits 32 bits 16 bits 8 bits Response EOF 1. Gray means that the field is optional. Response parameters: ● Sector security status if Option_flag is set (see Table 89) ● Four bytes of block data Table 89. b7 Sector security status b6 b5 Reserved for future used. All at 0. Table 90. b3 Password control bits b2 b1 Read / Write protection bits b0 0: Current sector not locked 1: Current sector locked Fast Read Single Block response format when Error_flag is set Response Response_flags SOF 8 bits 108/143 b4 Error code CRC16 8 bits 16 bits Doc ID 018932 Rev 8 Response EOF M24LR16E-R Command codes Response parameter: ● Error code as Error_flag is set: – 10h: the specified block is not available – 15h: the specified block is read protected . Figure 70. Fast Read Single Block frame exchange between VCD and M24LR16E-R VCD SOF Fast Read Single Block request EOF <-t1-> SOF M24LR16E-R Fast Read Single Block response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Fast Read Single block command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. 26.18 Fast Inventory Initiated Before receiving the Fast Inventory Initiated command, the M24LR16E-R must have received an Initiate or a Fast Initiate command in order to set the Initiate_ flag. If not, the M24LR16E-R does not answer to the Fast Inventory Initiated command. The subcarrier_flag should be set to 0, otherwise the M24LR16E-R answers with an error code. On receiving the Fast Inventory Initiated request, the M24LR16E-R runs the anticollision sequence. The Inventory_flag must be set to 1. The meaning of flags 5 to 8 is shown in Table 29. The data rate of the response is multiplied by 2. The request contains: ● the flags, ● the Inventory command code, ● the AFI if the AFI flag is set, ● the mask length, ● the mask value, ● the CRC. The M24LR16E-R does not generate any answer in case of error. Table 91. Fast Inventory Initiated request format Request Request SOF _flags 8 bits Fast Inventory Initiated C1h IC Mfg Optional Mask Mask value code AFI length 02h 8 bits Doc ID 018932 Rev 8 8 bits 0 - 64 bits CRC16 Request EOF 16 bits 109/143 Command codes M24LR16E-R The Response contains: ● the flags, ● the Unique ID. Table 92. Fast Inventory Initiated response format Response Response DSFID SOF _flags 8 bits 8 bits UID CRC16 64 bits 16 bits Response EOF During an Inventory process, if the VCD does not receive an RF M24LR16E-R response, it waits for a time t3 before sending an EOF to switch to the next slot. t3 starts from the rising edge of the request EOF sent by the VCD. ● If the VCD sends a 100% modulated EOF, the minimum value of t3 is: t3min = 4384/fC (323.3µs) + tSOF ● If the VCD sends a 10% modulated EOF, the minimum value of t3 is: t3min = 4384/fC (323.3µs) + tNRT where: ● tSOF is the time required by the M24LR16E-R to transmit an SOF to the VCD ● tNRT is the nominal response time of the M24LR16E-R tNRT and tSOF are dependent on the M24LR16E-R-to-VCD data rate and subcarrier modulation mode. When configured in the RF busy mode, the RF WIP/BUSY pin is driven to 0 from the SOF starting the inventory command to the end of the M24LR16E-R response.If the M24LR16ER does not receive the corresponding slot marker, the RF WIP/BUSY pin remains at 0 till the next RF power-off. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. 110/143 Doc ID 018932 Rev 8 M24LR16E-R 26.19 Command codes Fast Initiate On receiving the Fast Initiate command, the M24LR16E-R sets the internal Initiate_flag and sends back a response only if it is in the Ready state. The command has to be issued in the Non Addressed mode only (Select_flag is reset to 0 and Address_flag is reset to 0). If an error occurs, the M24LR16E-R does not generate any answer. The Initiate_flag is reset after a power-off of the M24LR16E-R. The data rate of the response is multiplied by 2. The subcarrier_flag should be set to 0, otherwise the M24LR16E-R answers with an error code. The request contains: ● No data Table 93. Request SOF Fast Initiate request format Request_flags Fast Initiate IC Mfg Code CRC16 8 bits C2h 02h 16 bits Request EOF The response contains: ● the flags, ● the Unique ID. Table 94. Fast Initiate response format Response Response DSFID SOF _flags 8 bits 8 bits UID CRC16 64 bits 16 bits Response EOF Figure 71. Fast Initiate frame exchange between VCD and M24LR16E-R VCD SOF Fast Initiate request EOF M24LR16E-R <-t1-> SOF Fast Initiate response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Fast Initiate command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. Doc ID 018932 Rev 8 111/143 Command codes 26.20 M24LR16E-R Fast Read Multiple Block On receiving the Fast Read Multiple Block command, the M24LR16E-R reads the selected blocks and sends back their value in multiples of 32 bits in the response. The blocks are numbered from 00h to 1FFh in the request and the value is minus one (–1) in the field. For example, if the “Number of blocks” field contains the value 06h, seven blocks are read. The maximum number of blocks is fixed to 32 assuming that they are all located in the same sector. If the number of blocks overlaps sectors, the M24LR16E-R returns an error code. The Protocol_extension_flag should be set to 1 for the M24LR16E-R to operate correctly. If the Protocol_extension_flag is at 0, the M24LR16E-R answers with an error code. The Option_flag is supported. The data rate of the response is multiplied by 2. The subcarrier_flag should be set to 0, otherwise the M24LR16E-R answers with an error code. Table 95. Fast Read Multiple Block request format Request Request_ SOF flags Fast Read Multiple Block IC Mfg code UID(1) C3h 02h 64 bits 8 bits First Number Request block of CRC16 EOF number blocks 16 bits 8 bits 16 bits 1. Gray means that the field is optional. Request parameters: ● Request flag ● UID (Optional) ● First block number ● Number of blocks Table 96. Fast Read Multiple Block response format when Error_flag is NOT set Response Response_ SOF flags 8 bits Sector security status(1) Data CRC16 8 bits(2) 32 bits(2) 16 bits 1. Gray means that the field is optional. 2. Repeated as needed. Response parameters: ● Sector security status if Option_flag is set (see Table 97) ● N block of data Table 97. b7 Sector security status if Option_flag is set b6 b5 Reserved for future use. All at 0. 112/143 b4 b3 Password control bits b2 b1 Read / Write protection bits Doc ID 018932 Rev 8 b0 0: Current sector not locked 1: Current sector locked Response EOF M24LR16E-R Command codes Table 98. Fast Read Multiple Block response format when Error_flag is set Response SOF Response_flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set: – 03h: the option is not supported – 10h: block address not available – 15h: block read-protected Figure 72. Fast Read Multiple Block frame exchange between VCD and M24LR16E-R VCD SOF Fast Read Multiple Block request M24LR16E-R EOF <-t1-> SOF Fast Read Multiple Block response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Fast Read Multiple Block command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. 26.21 Inventory Initiated Before receiving the Inventory Initiated command, the M24LR16E-R must have received an Initiate or a Fast Initiate command in order to set the Initiate_ flag. If not, the M24LR16E-R does not answer to the Inventory Initiated command. On receiving the Inventory Initiated request, the M24LR16E-R runs the anticollision sequence. The Inventory_flag must be set to 1. The meaning of flags 5 to 8 is given in Table 29. The request contains: ● the flags, ● the Inventory Command code, ● the AFI if the AFI flag is set, ● the mask length, ● the mask value, ● the CRC. The M24LR16E-R does not generate any answer in case of error. Doc ID 018932 Rev 8 113/143 Command codes Table 99. M24LR16E-R Inventory Initiated request format IC Optional Mask Mfg AFI length code Request Request Inventory SOF _flags Initiated 8 bits D1h 02h 8 bits 8 bits Mask value CRC16 0 - 64 bits 16 bits Request EOF The response contains: ● the flags, ● the Unique ID. Table 100. Inventory Initiated response format Response Response SOF _flags 8 bits DSFID UID CRC16 8 bits 64 bits 16 bits Response EOF During an Inventory process, if the VCD does not receive an RF M24LR16E-R response, it waits for a time t3 before sending an EOF to switch to the next slot. t3 starts from the rising edge of the request EOF sent by the VCD. ● If the VCD sends a 100% modulated EOF, the minimum value of t3 is: t3min = 4384/fC (323.3µs) + tSOF ● If the VCD sends a 10% modulated EOF, the minimum value of t3 is: t3min = 4384/fC (323.3µs) + tNRT where: ● tSOF is the time required by the M24LR16E-R to transmit an SOF to the VCD ● tNRT is the nominal response time of the M24LR16E-R tNRT and tSOF are dependent on the M24LR16E-R-to-VCD data rate and subcarrier modulation mode. When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF starting the inventory command to the end of the M24LR16E-R response. If the M24LR16ER does not receive the corresponding slot marker, the RF WIP/BUSY pin remains at 0 till the next RF power-off. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. 114/143 Doc ID 018932 Rev 8 M24LR16E-R 26.22 Command codes Initiate On receiving the Initiate command, the M24LR16E-R sets the internal Initiate_flag and sends back a response only if it is in the ready state. The command has to be issued in the Non Addressed mode only (Select_flag is reset to 0 and Address_flag is reset to 0). If an error occurs, the M24LR16E-R does not generate any answer. The Initiate_flag is reset after a power-off of the M24LR16E-R. The request contains: ● No data Table 101. Initiate request format Request Request_flags SOF Initiate IC Mfg code CRC16 D2h 02h 16 bits 8 bits Request EOF The response contains: ● the flags, ● the Unique ID. . Table 102. Initiate Initiated response format Response Response SOF _flags 8 bits DSFID UID CRC16 8 bits 64 bits 16 bits Response EOF Figure 73. Initiate frame exchange between VCD and M24LR16E-R VCD M24LR16E-R SOF Initiate request EOF <-t1-> SOF Initiate response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Initiate command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. Doc ID 018932 Rev 8 115/143 Command codes 26.23 M24LR16E-R ReadCfg On receiving the ReadCfg command, the M24LR16E-R reads the Configuration byte and sends back its 8-bit value in the response. The Protocol_extension_flag should be set to 0 for the M24LR16E-R to operate correctly. If the Protocol_extension_flag is at 1, the M24LR16E-R answers with an error code. The Option_flag is not supported. The Inventory_flag must be set to 0. Table 103. ReadCfg request format Request Request_ SOF flags ReadCfg IC Mfg code UID(1) CRC16 A0h 02h 64 bits 16 bits 8 bits Request EOF 1. Gray means that the field is optional. Request parameters: ● UID (optional) Table 104. ReadCfg response format when Error_flag is NOT set Response SOF Response_flags Data CRC16 8 bits 8 bits 16 bits Response EOF Response parameters: ● One byte of data: Configuration byte Table 105. ReadCfg response format when Error_flag is set Response SOF Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set – 03h: the option is not supported – 0Fh: error with no information given Figure 74. ReadCfg frame exchange between VCD and M24LR16E-R VCD SOF ReadCfg request EOF M24LR16E-R 116/143 <-t1-> SOF Doc ID 018932 Rev 8 ReadCfg response EOF M24LR16E-R Command codes When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the ReadCfg command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. 26.24 WriteEHCfg On receiving the WriteEHCfg command, the M24LR16E-R writes the data contained in the request to the Configuration byte and reports whether the write operation was successful in the response. The Protocol_extension_flag should be set to 0 for the M24LR16E-R to operate correctly. If the Protocol_extension_flag is at 1, the M24LR16E-R answers with an error code. The Option_flag is supported, the Inventory_flag is not supported. During the RF write cycle Wt, there should be no modulation (neither 100% nor 10%), otherwise, the M24LR16E-R may not program correctly the data into the Configuration byte. The Wt time is equal to t1nom + 18 × 302 µs. Table 106. WriteEHCfg request format Request Request_ WriteEHCfg SOF flags 8 bits IC Mfg code UID(1) Data CRC16 02h 64 bits 8 bits 16 bits A1h Request EOF 1. Gray means that the field is optional. Request parameters: ● Request flags ● UID (optional) ● Data: during WriteEHCfg command, bit 3 of the data is ignored (see Table 14). Table 107. WriteEHCfg response format when Error_flag is NOT set Response SOF Response_flags CRC16 8 bits 16 bits Response EOF Response parameter: ● No parameter. The response is send back after the writing cycle. Table 108. WriteEHCfg response format when Error_flag is set Response SOF Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set: – 13h: the specified block was not successfully programmed Doc ID 018932 Rev 8 117/143 Command codes M24LR16E-R Figure 75. WriteEHCfg frame exchange between VCD and M24LR16E-R VCD SOF WriteEHCfg request EOF WriteEHCfg response M24LR16ER <-t1-> SOF M24LR16ER <------------------- Wt ---------------> SOF EOF WriteEHCfg sequence when error WriteEHCfg response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the WriteEHCfg command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin is tied to 0 for the entire duration of the internal write cycle (from the end of a valid WriteEHCfg command to the beginning of the M24LR16E-R response). 26.25 WriteDOCfg On receiving the WriteDOCfg command, the M24LR16E-R writes the data contained in the request to the Configuration byte and reports whether the write operation was successful in the response. The Protocol_extension_flag should be set to 0 for the M24LR16E-R to operate correctly. If the Protocol_extension_flag is at 1, the M24LR16E-R answers with an error code. The Option_flag is supported, the Inventory_flag is not supported. During the RF write cycle Wt, there should be no modulation (neither 100% nor 10%), otherwise, the M24LR16E-R may not program correctly the data into the Configuration byte. The Wt time is equal to t1nom + 18 × 302 µs. Table 109. WriteDOCfg request format Request SOF Request_ flags WriteDOCfg IC Mfg code UID(1) Data CRC16 8 bits A4h 02h 64 bits 8 bits 16 bits Request EOF 1. Gray means that the field is optional. Request parameters: 118/143 ● Request flag ● UID (optional) ● Data: during a WriteDOCfg command, bits 2 to 0 of the data are ignored (see Table 14). Doc ID 018932 Rev 8 M24LR16E-R Command codes Table 110. WriteDOCfg response format when Error_flag is NOT set Response SOF Response_flags CRC16 8 bits 16 bits Response EOF Response parameter: ● No parameter. The response is sent back after the writing cycle. Table 111. WriteDOCfg response format when Error_flag is set Response SOF Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set: – 13h: the specified block was not successfully programmed Figure 76. WriteDOCfg frame exchange between VCD and M24LR16E-R VCD SOF WriteDOCfg request EOF WriteDOCfg response M24LR16E-R <-t1-> SOF EOF M24LR16E-R <----------------- Wt --------------> SOF WriteDOCfg sequence when error WriteDOCfg response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the WriteEHCfg command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin is tied to 0 for the entire duration of the internal write cycle (from the end of a valid WriteDOCfg command to the beginning of the M24LR16E-R response). Doc ID 018932 Rev 8 119/143 Command codes 26.26 M24LR16E-R SetRstEHEn On receiving the SetRstEHEn command, the M24LR16E-R sets or resets the EH_enable bit in the volatile Control register. The Protocol_extension_flag should be set to 0 for the M24LR16E-R to operate correctly. If the Protocol_extension_flag is at 1, the M24LR16E-R answers with an error code. The Option_flag and the Inventory_flag are not supported. Table 112. SetRstEHEn request format Request Request_ SetRstEHEn SOF flags 8 bits IC Mfg code UID(1) Data CRC16 02h 64 bits 8 bits 16 bits A2h Request EOF 1. Gray means that the field is optional. Request parameters: ● Request flags ● UID (optional) ● Data: during a SetRstEHEn command, bits 7 to 1 are ignored. Bit 0 is the EH_enable bit. Table 113. SetRstEHEn response format when Error_flag is NOT set Response SOF Response_flags CRC16 8 bits 16 bits Response EOF Response parameter: ● No parameter. The response is sent back after t1. Table 114. SetRstEHEn response format when Error_flag is set Response SOF Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response parameter: ● Error code as Error_flag is set: – 120/143 03h: the option is not supported Doc ID 018932 Rev 8 Response EOF M24LR16E-R Command codes Figure 77. SetRstEHEn frame exchange between VCD and M24LR16E-R VCD SOF SetRstEHEn request EOF M24LR16E-R <-t1-> SOF SetRstEHEn response EOF WriteEHCfg sequence when no error M24LR16E-R <-t1-> SOF SetRstEHEn response EOF WriteEHCfg sequence when error When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the SetRstEHEn command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. 26.27 CheckEHEn On receiving the CheckEHEn command, the M24LR16E-R reads the Control register and sends back its 8-bit value in the response. The Protocol_extension_flag should be set to 0 for the M24LR16E-R to operate correctly. If the Protocol_extension_flag is at 1, the M24LR16E-R answers with an error code. The Option_flag is not supported. The Inventory_flag must be set to 0. Table 115. CheckEHEn request format Request Request_ SOF flags CheckEHEn IC Mfg code UID(1) CRC16 A3h 02h 64 bits 16 bits 8 bits Request EOF 1. Gray means that the field is optional. Request parameters: ● UID (optional) Table 116. CheckEHEn response format when Error_flag is NOT set Response SOF Response_flags Data CRC16 8 bits 8 bits 16 bits Response EOF Response parameters: ● One byte of data: volatile Control register (see Table 15) Doc ID 018932 Rev 8 121/143 Command codes M24LR16E-R Table 117. CheckEHEn response format when Error_flag is set Response SOF Response_ flags Error code CRC16 8 bits 8 bits 16 bits Response EOF Response parameter: ● Error code as Error_flag is set – 03h: the option is not supported Figure 78. CheckEHEn frame exchange between VCD and M24LR16E-R VCD SOF CheckEHEn request EOF <-t1-> SOF M24LR16E-R CheckEHEn response EOF When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the CheckEHEn command to the end of the M24LR16E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin remains in high-Z state. 122/143 Doc ID 018932 Rev 8 M24LR16E-R 27 Maximum rating Maximum rating Stressing the device above the rating listed in Table 118 may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the operating sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect the device reliability. Refer also to the STMicroelectronics SURE Program and other relevant quality documents. Table 118. Absolute maximum ratings Symbol TA Parameter Ambient operating temperature TSTG, Storage conditions hSTG, tSTG Min. Max. Unit –40 85 °C 15 25 °C 6(1) months Sawn wafer on UV tape kept in its original packing form TSTG Storage temperature UFDFPN8 (MLP8), SO8, TSSOP8 TLEAD Lead temperature during soldering UFDFPN8 (MLP8), SO8, TSSOP8 VIO I2C input or output range –0.50 6.5 V VCC I2C supply voltage –0.50 6.5 V DC output current on pin SDA or RF WIP/BUSY (when equal to 0) 5 mA RF supply current AC0 - AC1 50 mA 27 V 11 V IOL_MAX ICC(3) RF input voltage amplitude peak VMAX_1(3) to peak between AC0 and AC1, GND pad left floating VMAX_2(3) VESD –65 150 see note (2) VAC0-VAC1 AC voltage between AC0 and GND, or AC1 and GND VAC0-GND, or VAC1-GND Electrostatic discharge voltage (human body model)(4) AC0, AC1 1000 Other pads 3500 Electrostatic discharge voltage (Machine model) -1 °C °C V 400 1. Counted from ST shipment date. 2. Compliant with JEDEC Std J-STD-020C (for small body, Sn-Pb or Pb assembly), the ST ECOPACK® 7191395 specification, and the European directive on Restrictions on Hazardous Substances (RoHS) 2002/95/EU. 3. Based on characterization, not tested in production. 4. AEC-Q100-002 (compliant with JEDEC Std JESD22-A114A, C1 = 100 pF, R1 = 1500 Ω, R2 = 500 Ω) Doc ID 018932 Rev 8 123/143 I2C DC and AC parameters 28 M24LR16E-R I2C DC and AC parameters This section summarizes the operating and measurement conditions, and the DC and AC characteristics of the device in I2C mode. The parameters in the DC and AC characteristic tables that follow are derived from tests performed under the measurement conditions summarized in the relevant tables. Designers should check that the operating conditions in their circuit match the measurement conditions when relying on the quoted parameters. Table 119. I2C operating conditions Symbol VCC TA Parameter Min. Max. Unit Supply voltage 1.8 5.5 V Ambient operating temperature –40 85 °C Min. Max. Unit Table 120. AC test measurement conditions Symbol CL Parameter Load capacitance 100 Input rise and fall times pF 50 ns Input levels 0.2VCC to 0.8VCC V Input and output timing reference levels 0.3VCC to 0.7VCC V Figure 79. AC test measurement I/O waveform Input Levels Input and Output Timing Reference Levels 0.8VCC 0.7VCC 0.3VCC 0.2VCC AI00825B Table 121. Input parameters Symbol Parameter Max. Unit CIN Input capacitance (SDA) - 8 pF CIN Input capacitance (other pins) - 6 pF Pulse width ignored (Input filter on SCL and SDA) - 80 ns tNS(1) 1. Characterized only. 124/143 Min. Doc ID 018932 Rev 8 I2C DC and AC parameters M24LR16E-R Table 122. I2C DC characteristics Symbol Parameter Test condition Min. Max. Unit ILI Input leakage current (SCL, SDA) VIN = VSS or VCC device in Standby mode ±2 µA ILO_Vout Vout output leakage current external voltage applied on Vout: VSS or VCC ±5 µA SDA in Hi-Z, external voltage applied on SDA: VSS or VCC ±2 µA VCC = 1.8 V, fc = 100 kHz (rise/fall time < 50 ns) 50 VCC = 1.8 V, fc = 400 kHz (rise/fall time < 50 ns) 100 VCC = 2.5 V, fc = 400 kHz (rise/fall time < 50 ns) 200 VCC = 5.5 V, fc = 400 kHz (rise/fall time < 50 ns) 400 VCC = 1.8 - 5.5 V 220 VIN = VSS or VCC VCC = 1.8 V 30 VIN = VSS or VCC VCC = 2.5 V 30 VIN = VSS or VCC VCC = 5.5 V 40 ILO ICC ICC0 ICC1 VIL VIH VOL Output leakage current Supply current (Read)(1) Supply current (Write)(1) Standby supply current Input low voltage (SDA, SCL) Input high voltage (SDA, SCL) Output low voltage µA VCC = 1.8 V –0.45 0.25VCC VCC = 2.5 V –0.45 0.25VCC VCC = 5.5 V –0.45 0.3VCC VCC = 1.8 V 0.75VCC VCC+1 VCC = 2.5 V 0.75VCC VCC+1 VCC = 5.5 V 0.7VCC VCC+1 IOL = 2.1 mA, VCC = 1.8 V or IOL = 3 mA, VCC = 5.5 V 0.4 µA µA V V V 1. SCL, SDA connected to Ground or VCC. SDA connected to VCC through a pull-up resistor. Doc ID 018932 Rev 8 125/143 I2C DC and AC parameters M24LR16E-R Table 123. I2C AC characteristics Test conditions specified in Table 119 Symbol Alt. fC fSCL Parameter Clock frequency Min. Max. Unit 25 400 kHz (1) µs µs tCHCL tHIGH Clock pulse width high 0.6 20000 tCLCH tLOW Clock pulse width low 1.3 20000(2) I²C timeout on Start condition 40 tSTART_OU ms T tXH1XH2(3) tR Input signal rise time 20 300 ns tXL1XL2(3) tF Input signal fall time 20 300 ns tDL1DL2 tF SDA (out) fall time 20 100 ns tDXCX tSU:DAT Data in set up time 100 ns tCLDX tHD:DAT Data in hold time 0 ns ns tCLQX tDH Data out hold time 100 tCLQV(4)(5) tAA Clock low to next data valid (access time) 100 tCHDX(6) tSU:STA Start condition set up time 900 600 ns ns 35000(7) tDLCL tHD:STA Start condition hold time 0.6 tCHDH tSU:STO Stop condition set up time 600 ns 1300 ns tDHDL tBUF tW Time between Stop condition and next Start condition I²C write time 5 µs ms 1. tCHCL timeout. 2. tCLCH timeout. 3. Values recommended by the I²C-bus Fast-Mode specification. 4. To avoid spurious Start and Stop conditions, a minimum delay is placed between SCL=1 and the falling or rising edge of SDA. 5. tCLQV is the time (from the falling edge of SCL) required by the SDA bus line to reach 0.8VCC in a compatible way with the I2C specification (which specifies tSU:DAT (min) = 100 ns), assuming that the Rbus × Cbus time constant is less than 500 ns (as specified in Figure 3). 6. For a reStart condition, or following a write cycle. 7. tDLCL timeout 126/143 Doc ID 018932 Rev 8 I2C DC and AC parameters M24LR16E-R Figure 80. I2C AC waveforms tXL1XL2 tCHCL tXH1XH2 tCLCH SCL tDLCL tXL1XL2 SDA In tCHDX tCLDX tXH1XH2 Start condition SDA Input SDA tDXCX Change tCHDH tDHDL Start Stop condition condition SCL SDA In tW tCHDH tCHDX Stop condition Write cycle Start condition tCHCL SCL tCLQV SDA Out tCLQX Data valid tDL1DL2 Data valid AI00795e Doc ID 018932 Rev 8 127/143 RF electrical parameters 29 M24LR16E-R RF electrical parameters This section summarizes the operating and measurement conditions, and the DC and AC characteristics of the device in RF mode. The parameters in the DC and AC Characteristic tables that follow are derived from tests performed under the Measurement Conditions summarized in the relevant tables. Designers should check that the operating conditions in their circuit match the measurement conditions when relying on the quoted parameters. Table 124. RF characteristics(1) (2) Symbol fCC Parameter Condition External RF signal frequency Operating field according to ISO MICARRIER 10% carrier modulation index (3) MI=(A-B)/(A+B) tRFSBL TA = -40 °C to 85 °C tRFR, tRFF 100% rise and fall time Unit 150 5000 mA/ m 15 30 H_ISO > 1000 mA/m 10 30 0.5 3.0 µs 7.1 9.44 µs 95 100 % 0.5 3.5 µs 7 9.44 µs 1 ms 10% minimum pulse width for bit 100% carrier modulation index Max 150 mA/m > H_ISO > 1000 mA/m 10% rise and fall time MICARRIER Typ 13.553 13.56 13.567 MHz H_ISO tRFR, tRFF Min MI=(A-B)/(A+B)(4) % tRFSBL 100% minimum pulse width for bit tMIN CD Minimum time from carrier generation to first data From H-field min fSH Subcarrier frequency high FCC/32 423.75 kHz fSL Subcarrier frequency low FCC/28 484.28 kHz t1 Time for M24LR16E-R response 4224/FS 318.6 320.9 323.3 µs t2 Time between commands 4224/FS 309 311.5 314 µs Wt RF write time (including internal Verify) ICC_RF Operating current (Read)(5) VAC0-VAC1 (4 V peak to peak) (6) CTUN Internal tuning capacitor in SO8 VBACK Backscattered level as defined by ISO test 128/143 f = 13.56 MHz 24.8 ISO10373-7 10 Doc ID 018932 Rev 8 5.75 ms 20 µA 27.5 30.2 pF mV M24LR16E-R RF electrical parameters Table 124. RF characteristics(1) (2) (continued) Symbol Parameter VMAX_1(3) RF input voltage amplitude between AC0 and AC1, GND pad left floating, VAC0-VAC1 peak to peak(7) VMAX_2(3) AC voltage between AC0 and GND or between AC1 and GND Inventory and Read operations VMIN_1(3) RF input voltage amplitude between AC0 and AC1, GND pad left floating, VAC0-VAC1 peak to peak(7) VMIN_2(3) AC voltage between AC0 and GND or between AC1 and GND tRF_OFF Condition Min Typ Max Unit 20 V 8.5 V 4 4.5 V Write operations 4.5 5 V Inventory and Read operations 1.8 2 V Write operations 2 2.2 V -1 RF OFF time Chip reset 2 ms 1. TA = –40 to 85 °C. Characterized only. 2. All timing characterizations were performed between 0 °C and 50 °C on a reference antenna with the following characteristics: External size: 75 mm x 48 mm Number of turns: 5 Width of conductor: 0.5 mm Space between two conductors: 0.3 mm Value of the tuning capacitor in SO8: 27.5 pF (M24LR16E-R) Value of the coil: 5 µH Tuning frequency: 13.56 MHz. 3. 15% (or more) carrier modulation index offers a better signal/noise ratio and therefore a wider operating range with a better noise immunity. 4. Temperature range 0 °C to 90 °C 5. Characterized on bench. 6. Characterized only, at room temperature only, measured at VAC0-VAC1 = 1 V peak to peak. 7. Characterized only, at room temperature only. Table 125. Operating conditions Symbol TA Parameter Ambient operating temperature Min. Max. Unit –40 85 °C Figure 81 shows an ASK modulated signal from the VCD to the M24LR16E-R. The test condition for the AC/DC parameters are: ● Close coupling condition with tester antenna (1 mm) ● M24LR16E-R performance measured at the tag antenna ● M24LR16E-R synchronous timing, transmit and receive Doc ID 018932 Rev 8 129/143 RF electrical parameters M24LR16E-R Figure 81. ASK modulated signal A B tRFF tRFR fCC tRFSBL tMIN CD MS19784V1 Table 126 below summarizes respectively the minimum AC0-AC1 input power level PAC0AC1_min required for the Energy harvesting mode, the corresponding maximum current consumption Isink_max and variation of the analog voltage Vout for the various Energy harvesting fan-out configurations defined by bits b0 and b1 of the Configuration byte. Table 126. Energy harvesting(1) (2) Range Hmin(3) Pmin(4) Vout@I=0 Vout@Isink_max Isink_max@Pmin 00 3.5 A/m 100 mW 2.7 V min 4.5 V max 1.7 V 6 mA 01 2.4 A/m 66 mW 2.7 V min 4.5 V max 1.9 V 3 mA 10 1.6 A/m 33 mW 2.7 V min 4.5 V max 2.1 V 1 mA 11 1.0 A/m 18 mW 2.7 V min 4.5 V max 2.3 V 300 µA 1. Characterized only 2. Valid from -40 °C to +85 °C 3. Hmin characterized according to ISO10373-7 test method 4. Pmin calculated from DC measurements 130/143 Doc ID 018932 Rev 8 M24LR16E-R RF electrical parameters Figure 82. Vout min vs. Isink 7PVU 7 7 7 7 7 N" N" N" N" *TJOL MS19777V1 Figure 83. Range 11 domain Field (H) 3.5 A/m 2.4 A/m 1.3 A/m 0.8 A/m 300 μA 1 mA 3 mA 6 mA Output current MS19758V1 Doc ID 018932 Rev 8 131/143 RF electrical parameters M24LR16E-R Figure 84. Range 10 domain Field (H) 3.5 A/m 2.4 A/m 1.3 A/m 0.8 A/m 300 μA 1 mA 3 mA 6 mA Output current MS19759V1 Figure 85. Range 01 domain Field (H) 3.5 A/m 2.4 A/m 1.3 A/m 0.8 A/m 300 μA 1 mA 3 mA 6 mA Output current MS19760V1 132/143 Doc ID 018932 Rev 8 M24LR16E-R RF electrical parameters Figure 86. Range 00 domain Field (H) 3.5 A/m 2.4 A/m 1.3 A/m 0.8 A/m 300 μA 1 mA 3 mA 6 mA Output current MS19761V1 Doc ID 018932 Rev 8 133/143 Package mechanical data 30 M24LR16E-R Package mechanical data In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK® packages, depending on their level of environmental compliance. ECOPACK® specifications, grade definitions and product status are available at: www.st.com. ECOPACK® is an ST trademark. Figure 87. SO8N – 8-lead plastic small outline, 150 mils body width, package outline h x 45˚ A2 A c ccc b e 0.25 mm GAUGE PLANE D k 8 E1 E 1 A1 L L1 SO-A 1. Drawing is not to scale. Table 127. SO8N – 8-lead plastic small outline, 150 mils body width, package data inches(1) millimeters Symbol Typ Min A Max Typ 1.75 Max 0.0689 A1 0.10 A2 1.25 b 0.28 0.48 0.0110 0.0189 c 0.17 0.23 0.0067 0.0091 ccc 0.25 0.0039 0.0098 0.0492 0.10 0.0039 D 4.90 4.80 5.00 0.1929 0.1890 0.1969 E 6.00 5.80 6.20 0.2362 0.2283 0.2441 E1 3.90 3.80 4.00 0.1535 0.1496 0.1575 e 1.27 – – 0.0500 – – h 0.25 0.50 k 0° 8° 0° 8° L 0.40 1.27 0.0157 0.0500 L1 1.04 0.0410 1. Values in inches are converted from mm and rounded to 4 decimal digits. 134/143 Min Doc ID 018932 Rev 8 M24LR16E-R Package mechanical data Figure 88. UFDFPN8 (MLP8) – 8-lead ultra thin fine pitch dual flat package no lead 2 × 3mm, package outline MB e D MC e b L1 L3 E b L1 L3 E2 Pin 1 E2 K K L L A D2 D2 eee A1 ZW_MEe 1. Drawing is not to scale. 2. The central pad (E2 × D2 area in the above illustration) is internally pulled to VSS. It must not be allowed to be connected to any other voltage or signal line on the PCB, for example during the soldering process. 3. The circle in the top view of the package indicates the position of pin 1. Table 128. UFDFPN8 (MLP8) 8-lead ultra thin fine pitch dual flat package no lead 2 x 3 mm, data inches(1) millimeters Symbol Typ Min Max Typ Min Max A 0.550 0.450 0.600 0.0217 0.0177 0.0236 A1 0.020 0.000 0.050 0.0008 0.0000 0.0020 b 0.250 0.200 0.300 0.0098 0.0079 0.0118 D 2.000 1.900 2.100 0.0787 0.0748 0.0827 1.200 1.600 0.0472 0.0630 2.900 3.100 0.1142 0.1220 1.200 1.600 0.0472 0.0630 D2 (rev MC) E 3.000 E2 (rev MC) e 0.500 0.1181 0.0197 K 0.300 L 0.300 L1 0.0118 0.500 0.0118 0.150 0.0197 0.0059 L3 0.300 0.0118 eee(2) 0.080 0.0031 1. Values in inches are converted from mm and rounded to 4 decimal digits. 2. Applied for exposed die paddle and terminals. Exclude embedding part of exposed die paddle from measuring. Doc ID 018932 Rev 8 135/143 Package mechanical data M24LR16E-R Figure 89. TSSOP8 – 8-lead thin shrink small outline, package outline D 8 5 c E1 1 E 4 α A1 A L A2 L1 CP b e TSSOP8AM 1. Drawing is not to scale. Table 129. TSSOP8 – 8-lead thin shrink small outline, package mechanical data inches(1) millimeters Symbol Typ Min A Max 0.05 0.15 0.8 1.05 b 0.19 c 0.09 1 CP Max 0.0472 0.002 0.0059 0.0315 0.0413 0.3 0.0075 0.0118 0.2 0.0035 0.0079 0.0394 0.1 0.0039 D 3 2.9 3.1 0.1181 0.1142 0.122 e 0.65 - - 0.0256 - - E 6.4 6.2 6.6 0.252 0.2441 0.2598 E1 4.4 4.3 4.5 0.1732 0.1693 0.1772 L 0.6 0.45 0.75 0.0236 0.0177 0.0295 L1 1 0° 8° a N 0.0394 0° 8° 8 8 1. Values in inches are converted from mm and rounded to 4 decimal digits. 136/143 Min 1.2 A1 A2 Typ Doc ID 018932 Rev 8 M24LR16E-R 31 Part numbering Part numbering Table 130. Ordering information scheme for packaged devices Example: M24LR16E-R MN 6 T /2 Device type M24LR = dual interface EEPROM 16 = memory size in Kbit E = support for energy harvesting Operating voltage R = VCC = 1.8 to 5.5 V Package MN = SO8N (150 mils width) MC = UFDFPN8 (MLP8) DW = TSSOP8 Device grade 6 = industrial: device tested with standard test flow over –40 to 85 °C Option T = Tape and reel packing Capacitance /2 = 27.5 pF Doc ID 018932 Rev 8 137/143 Anticollision algorithm (informative) Appendix A M24LR16E-R Anticollision algorithm (informative) The following pseudocode describes how anticollision could be implemented on the VCD, using recursivity. A.1 Algorithm for pulsed slots function function function function push (mask, address); pushes on private stack pop (mask, address); pops from private stack pulse_next_pause; generates a power pulse store(M24LR16E-R_UID); stores M24LR16E-R_UID function poll_loop (sub_address_size as integer) pop (mask, address) mask = address & mask; generates new mask ; send the request mode = anticollision send_Request (Request_cmd, mode, mask length, mask value) for sub_address = 0 to (2^sub_address_size - 1) pulse_next_pause if no_collision_is_detected ; M24LR16E-R is inventoried then store (M24LR16E-R_UID) else ; remember a collision was detected push(mask,address) endif next sub_address if stack_not_empty ; if some collisions have been detected and then ; not yet processed, the function calls itself poll_loop (sub_address_size); recursively to process the last stored collision endif end poll_loop main_cycle: mask = null address = null push (mask, address) poll_loop(sub_address_size) end_main_cycle 138/143 Doc ID 018932 Rev 8 M24LR16E-R CRC (informative) Appendix B B.1 CRC (informative) CRC error detection method The cyclic redundancy check (CRC) is calculated on all data contained in a message, from the start of the flags through to the end of Data. The CRC is used from VCD to M24LR16ER and from M24LR16E-R to VCD. Table 131. CRC definition CRC definition CRC type ISO/IEC 13239 Length 16 bits Polynomial 16 X + X12 + X5 + 1 = 8408h Direction Preset Residue Backward FFFFh F0B8h To add extra protection against shifting errors, a further transformation on the calculated CRC is made. The one’s complement of the calculated CRC is the value attached to the message for transmission. To check received messages, the two CRC bytes are often also included in the recalculation, for ease of use. In this case, the expected value for the generated CRC is the residue F0B8h. B.2 CRC calculation example This example in C language illustrates one method of calculating the CRC on a given set of bytes comprising a message. C-example to calculate or check the CRC16 according to ISO/IEC 13239 #define #define #define POLYNOMIAL0x8408// PRESET_VALUE0xFFFF CHECK_VALUE0xF0B8 x^16 + x^12 + x^5 + 1 #define #define #define NUMBER_OF_BYTES4// Example: 4 data bytes CALC_CRC1 CHECK_CRC0 void main() { unsigned int current_crc_value; unsigned char array_of_databytes[NUMBER_OF_BYTES + 2] = {1, 2, 3, 4, 0x91, 0x39}; int number_of_databytes = NUMBER_OF_BYTES; int calculate_or_check_crc; int i, j; calculate_or_check_crc = CALC_CRC; // calculate_or_check_crc = CHECK_CRC;// This could be an other example if (calculate_or_check_crc == CALC_CRC) { Doc ID 018932 Rev 8 139/143 CRC (informative) M24LR16E-R number_of_databytes = NUMBER_OF_BYTES; } else // check CRC { number_of_databytes = NUMBER_OF_BYTES + 2; } current_crc_value = PRESET_VALUE; for (i = 0; i < number_of_databytes; i++) { current_crc_value = current_crc_value ^ ((unsigned int)array_of_databytes[i]); for (j = 0; j < 8; j++) { if (current_crc_value & 0x0001) { current_crc_value = (current_crc_value >> 1) ^ POLYNOMIAL; } else { current_crc_value = (current_crc_value >> 1); } } } if (calculate_or_check_crc == CALC_CRC) { current_crc_value = ~current_crc_value; printf ("Generated CRC is 0x%04X\n", current_crc_value); // stream // } else { if { current_crc_value is now ready to be appended to the data (first LSByte, then MSByte) // check CRC (current_crc_value == CHECK_VALUE) printf ("Checked CRC is ok (0x%04X)\n", current_crc_value); } else { printf ("Checked CRC is NOT ok (0x%04X)\n", current_crc_value); } } } 140/143 Doc ID 018932 Rev 8 M24LR16E-R Application family identifier (AFI) (informative) Appendix C Application family identifier (AFI) (informative) The AFI (application family identifier) represents the type of application targeted by the VCD and is used to extract from all the M24LR16E-Rs present only the M24LR16E-R meeting the required application criteria. It is programmed by the M24LR16E-R issuer (the purchaser of the M24LR16E-R). Once locked, it cannot be modified. The most significant nibble of the AFI is used to code one specific or all application families, as defined in Table 132. The least significant nibble of the AFI is used to code one specific or all application subfamilies. Subfamily codes different from 0 are proprietary. Table 132. AFI coding(1) AFI AFI most significant nibble least significant nibble ‘0’ ‘0’ All families and subfamilies No applicative preselection ‘X’ '0 All subfamilies of family X Wide applicative preselection 'X '‘Y’ Only the Yth subfamily of family X ‘0’ ‘Y’ Proprietary subfamily Y only ‘1 '‘0’, ‘Y’ Transport Mass transit, bus, airline,... '2 '‘0’, ‘Y’ Financial IEP, banking, retail,... '3 '‘0’, ‘Y’ Identification Access control,... '4 '‘0’, ‘Y’ Telecommunication Public telephony, GSM,... ‘5’ ‘0’, ‘Y’ Medical '6 '‘0’, ‘Y’ Multimedia '7 '‘0’, ‘Y’ Gaming 8 '‘0’, ‘Y’ Data Storage '9 '‘0’, ‘Y’ Item management 'A '‘0’, ‘Y’ Express parcels 'B '‘0’, ‘Y’ Postal services 'C '‘0’, ‘Y’ Airline bags 'D '‘0’, ‘Y’ RFU 'E '‘0’, ‘Y’ RFU ‘F’ ‘0’, ‘Y’ RFU Meaning VICCs respond from Examples / Note Internet services.... Portable files,... 1. X = '1' to 'F', Y = '1' to 'F' Doc ID 018932 Rev 8 141/143 Revision history M24LR16E-R Revision history Table 133. Document revision history Date Revision 24-Jun-2011 1 Initial release. 28-Jul-2011 2 Updated Description, Table 118: Absolute maximum ratings, Table 126: Energy harvesting. Added figures 52, 56, 57, 82 to 86. 29-Jul-2011 3 Updated IC Ref data. 29-Jul-2011 4 Updated IC Ref data from 4Fh to 4Eh. 5 Updated: – Table 126: Energy harvesting – Section 5.6: Memory addressing – Figure 12: I2C present password command – Figure 13: I2C write password command 6 Updated: – Table 118: Absolute maximum ratings – Table 122: I2C DC characteristics – Table 124: RF characteristics – Table 126: Energy harvesting – Figure 81: ASK modulated signal – Figure 82: Vout min vs. Isink – Figure 83: Range 11 domain – Figure 84: Range 10 domain – Figure 85: Range 01 domain – Figure 86: Range 00 domain 7 Modified Table 10: Password system area on page 25 (Removed “Add” column). Modified Table 126: Energy harvesting on page 130 (4.5 V max instead of 4.0 V max). 8 Updated Table 5: Sector details on page 21 and Figure 49: M24LR16E-R state transition diagram. Updated clock pulse width values in Table 123: I2C AC characteristics on page 126. 09-Aug-2011 09-Nov-2011 13-Dec-2011 12-Jun-2012 142/143 Changes Doc ID 018932 Rev 8 M24LR16E-R Please Read Carefully: Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST’s terms and conditions of sale. Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no liability whatsoever relating to the choice, selection or use of the ST products and services described herein. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such third party products or services or any intellectual property contained therein. UNLESS OTHERWISE SET FORTH IN ST’S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. UNLESS EXPRESSLY APPROVED IN WRITING BY TWO AUTHORIZED ST REPRESENTATIVES, ST PRODUCTS ARE NOT RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY, DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. ST PRODUCTS WHICH ARE NOT SPECIFIED AS "AUTOMOTIVE GRADE" MAY ONLY BE USED IN AUTOMOTIVE APPLICATIONS AT USER’S OWN RISK. Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any liability of ST. ST and the ST logo are trademarks or registered trademarks of ST in various countries. Information in this document supersedes and replaces all information previously supplied. The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners. © 2012 STMicroelectronics - All rights reserved STMicroelectronics group of companies Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Philippines - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America www.st.com Doc ID 018932 Rev 8 143/143