ETC 48D12.500

12 Watt Dual Series DC/DC Converters
Features
Description
!
Low Noise Output
!
LC Type Input Filter
!
Six-Sided Shielded Steel Case
These 10 and 12 Watt Dual Output DC/DC converters are
designed for telecommunications, medical or industrial
equipment and instrumentation systems. The converters
feature very wide input voltage ranges.
!
Very Wide Input Voltage Ranges
(9-36, 18-54, and 24-72)
!
High Efficiency Operation
!
Long Term Output Fault Survival
!
5 Year Warranty
The converter consists of a hi-speed chopper circuit using
state of the art MOSFET technology, isolation transformer,
and high regulation linear post regulator. This provides for
very low noise and ultra stable output voltages.
Selection Chart
Model
Input Range
VDC
MIN
MAX
Outputs
VDC
Outputs
mA
±500
24D12.500
9.00
36.00
±12.0
24D15.400
9.00
36.00
±15.0
±400
28D5.1000
18.00
54.00
±5.0
±1000
48D12.500
24.00
72.00
±12.0
±500
48D15.400
24.00
72.00
±15.0
±400
12 Watt Dual Series Block Diagram
CROSS
COUPLED
FOLDBACK
CURRENT LIMIT
3 + OUTPUT
A
+ INPUT 1
- INPUT 2
LC
INPUT
FILTER
100µF
LOW TC
REFERENCE
PWM
CONTROL
4 CMN
100µF
SHIELDED ISOLATION
TRANSFORMER
CROSS
COUPLED
FOLDBACK
CURRENT LIMIT
5 - OUTPUT
SIX-SIDED SHIELDED STEEL CASE
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: [email protected]
1
4/8/99
STCO #970624-2, STCO #990408-1
PWM FEEDBACK
12 Watt Dual Series DC/DC Converters
Input Parameters*
Model
24D12.500
24D15.400
Units
Input Current Full Load
No Load
MIN
MAX
TYP
MAX
TYP
TYP
Efficiency
TYP
70
%
Switching Frequency
TYP
100
kHz
Maximum Input Overvoltage, 100ms
No damage
MAX
40
VDC
Turn-on Time, 1% Output Error
TYP
60
ms
Voltage Range
Reflected Ripple, 0-20MHz bw
9.00
36.00
20
45
VDC
mA P-P
710
40
700
40
Recommended Fuse
mA
(2)
Model
28D5.1000
18.00
54.00
20
50
600
40
48D12.500
48D15.400
Input Current Full Load
No Load
Efficiency
TYP
60
70
%
Switching Frequency
TYP
87
100
kHz
Maximum Input Overvoltage, 100ms
No damage
MAX
60
80
VDC
Turn-on Time, 1% Output Error
TYP
Voltage Range
Reflected Ripple, 0-20MHz bw
24.00
72.00
15
30
Units
MIN
MAX
TYP
MAX
TYP
TYP
VDC
mA P-P
360
24
350
24
60
Recommended Fuse
mA
ms
(2)
Output Parameters*
24D12.500
48D12.500
±12
0
±500
11.90
12.00
12.10
0.6
1.0
0.02
0.07
0.02
0.07
0.02
28D5.1000
Output Voltage
Line Regulation
Vin = Min-Max VDC
Short Term Stability (4)
MIN
MAX
MIN
TYP
MAX
TYP
MAX
TYP
MAX
TYP
MAX
TYP
Long Term Stability
TYP
Rated Current (3)
Voltage Range
100% Load
Output Balance
(Plus to Minus Output, Full Load)
Load Regulation 0-100% Load
±5
0
+1100/-900
4.95
5.00
5.05
0.05
0.10
24D15.400
48D15.400
±15
0
±400
14.90
15.00
15.10
Units
VDC
mA
VDC
%
0.02
0.07
A
%
%
%
0.3
%/kHrs
Transient Response (5)
TYP
20
µs
Dynamic Response (6)
TYP
20
mV peak
Input Ripple Rejection (7)
TYP
TYP
MAX
TYP
MAX
60
10
40
50
150
dB
Noise, 0-20MHz bw
Temperature Coefficient
100
300
Short Circuit Protection to
Common for all Outputs
mV P-P
50
150
ppm/°C
Continuous, 8 Hours Minimum Current Limit
NOTES
parameters measured at Tc=25°C, nominal input voltage
* All
and full rated load unless otherwise noted. Refer to the
CALEX Application Notes for the definition of terms,
measurement circuits and other information.
(2) Determine the correct fuse size by calculating the maximum DC
current drain at low line input, maximum load then adding 20 to
25 percent.
(3)
(4)
(5)
(6)
No minimum load required.
Short term stability is specified after a 30 minute warm-up at full
load.
Transient response is defined as the time for the output to settle
from a 100% step load change to a 1% error band (rise time of
step = 2µSec).
Dynamic response is defined as the peak overshoot during a
transient as defined in note 5 above.
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: [email protected]
2
4/8/99
STCO #970624-2, STCO #990408-1
MODEL
12 Watt Dual Series DC/DC Converters
General Specifications *
All Models
Isolation
Isolation Voltage
10µA Leakage
Input-Output
Input to Output
Capacitance
Environmental
Case Operating Range
No Derating
Case Functional Range (8)
Storage Range
Thermal Impedance (9)
Units
MIN
500
VDC
TYP
120
pF
MIN
MAX
MIN
MAX
MIN
MAX
TYP
-25
80
-40
85
-55
100
6
°C/Watt
6.5
oz
°C
°C
°C
General
TYP
Mounting Kits
(7)
(8)
(9)
MK215-022 & MK215-08BDV
BOTTOM VIEW
The input ripple rejection is specified for DC to 120Hz ripple with
a modulation amplitude of 1% of Vin.
The functional temperature range is intended to give an additional
data point for use in evaluating this power supply. At the low
functional temperature the power supply will function with no
side effects, however sustained operation at the high functional
temperature will reduce expected operational life. The data
sheet specifications are not guaranteed over the functional
temperature range.
The case thermal impedance is specified as the case temperature
rise over ambient per package watt dissipated.
Mechanical tolerances unless otherwise noted:
X.XX dimensions: ±0.020 inches
X.XXX dimensions: ±0.005 inches
Pin
1
2
3
4
5
Typical Performance (Tc=25°C, Full Rated Load).
24D15.400 EFFICIENCY Vs. LINE INPUT
Function
+INPUT
-INPUT
+OUTPUT
CMN
-OUTPUT
48D15.400 EFFICIENCY Vs. LINE INPUT
72
A
75
100% FULL LOAD
70
EFFICIENCY (%)
EFFICIENCY (%)
100% FULL LOAD
68
50% FULL LOAD
66
64
10
15
20
25
30
SIDE VIEW
35
70
65
50% FULL LOAD
60
40
20
LINE INPUT (VOLTS)
30
40
50
60
70
80
LINE INPUT (VOLTS)
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: [email protected]
3
4/8/99
STCO #970624-2, STCO #990408-1
Unit Weight
12 Watt Dual Series DC/DC Converters
Typical Performance (Tc=25°C, Full Rated Load).
48D15.400 EFFICIECNY Vs. LOAD
24D INPUT CURRENT Vs. LINE INPUT
80
INPUT CURRENT (AMPS)
2.50
EFFICIENCY (%)
70
LINE = 24VDC
60
LINE = 48VDC
50
LINE = 72VDC
40
2.00
100% RATED LOAD
1.50
1.00
0.50
50% RATED LOAD
30
0.00
0
20
40
60
80
100
0
5
10
LOAD (%)
OUTPUT VOLTAGE Vs CASE TEMPERATURE
20
25
30
35
40
70
80
48D INPUT CURRENT Vs. LINE INPUT
1.2
INPUT CURRENT (AMPS)
0.2
NORMALIZED OUTPUT (%)
15
LINE INPUT (VOLTS)
0.1
NEGATIVE OUTPUT
0.0
POSITIVE OUTPUT
-0.1
1.0
0.8
0.6
100% RATED LOAD
0.4
0.2
50% RATED LOAD
0.0
-30
-20
-10
0
10
20
30
40
50
60
70
80
0
10
20
CASE TEMPERATURE (Deg C)
30
40
50
60
LINE INPUT (VOLTS)
OUTPUT VOLTAGE Vs. OUTPUT LOAD
OUTPUT IMPEDANCE Vs. FREQUENCY
120
100
+ OUTPUT
IMPEDANCE (OHMS)
80
- OUTPUT
60
40
.1
.01
A
20
0
.001
0
20
40
60
80
100
120
140
160
180
200
10
100
1K
10K
100K
1M
FREQUENCY (Hz)
OUTPUT LOAD (%)
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: [email protected]
4
4/8/99
STCO #970624-2, STCO #990408-1
OUTPUT VOLTAGE (%)
1