M58LW032C 32 Mbit (2Mb x16, Uniform Block, Burst) 3V Supply Flash Memory FEATURES SUMMARY ■ WIDE x16 DATA BUS for HIGH BANDWIDTH ■ Figure 1. Packages SUPPLY VOLTAGE – VDD = 2.7 to 3.6V core supply voltage for Program, Erase and Read operations ■ – VDDQ = 1.8 to VDD for I/O Buffers SYNCHRONOUS/ASYNCHRONOUS READ – Synchronous Burst read – Asynchronous Random Read – Asynchronous Address Latch Controlled Read TSOP56 (N) 14 x 20 mm – Page Read ■ ACCESS TIME TBGA – Synchronous Burst Read up to 56MHz – Asynchronous Page Mode Read 90/25ns, 110/25ns – Random Read 90ns, 110ns ■ TBGA64 (ZA) 10 x 13 mm PROGRAMMING TIME – 16 Word Write Buffer – 12µs Word effective programming time ■ 32 UNIFORM 64 KWord MEMORY BLOCKS ■ ENHANCED SECURITY – Block Protection/ Unprotection – Smart Protection: irreversible block locking system – VPEN signal for Program Erase Enable – 128 bit Protection Register with 64 bit Unique Code in OTP area ■ PROGRAM and ERASE SUSPEND ■ COMMON FLASH INTERFACE ■ 100,000 PROGRAM/ERASE CYCLES per BLOCK ■ ELECTRONIC SIGNATURE – Manufacturer Code: 0020h – Device Code M58LW032C : 8822h April 2003 1/61 M58LW032C TABLE OF CONTENTS SUMMARY DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Figure 2. Logic Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Table 1. Signal Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Figure 3. TSOP56 Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Figure 4. TBGA64 Connections (Top view through package) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Figure 5. Block Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 SIGNAL DESCRIPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Address Inputs (A1-A21). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Data Inputs/Outputs (DQ0-DQ15). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Chip Enable (E). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Output Enable (G). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Write Enable (W). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Reset/Power-Down (RP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Latch Enable (L). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Clock (K).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Valid Data Ready (R). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Status/(Ready/Busy) (STS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Program/Erase Enable (VPEN). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 VDD Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 VDDQ Supply Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 VSS Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 VSSQ Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 BUS OPERATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Address Latch.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Bus Read. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Bus Write. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Output Disable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Power-Down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Standby. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Table 2. Bus Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 READ MODES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Asynchronous Read Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Asynchronous Latch Controlled Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Asynchronous Random Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Asynchronous Page Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Synchronous Read Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Synchronous Burst Read. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Single Synchronous Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2/61 M58LW032C CONFIGURATION REGISTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Read Select Bit (CR15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 X-Latency Bits (CR13-CR11). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Internal Clock Divider Bit (CR10). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Y-Latency Bit (CR9). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Valid Data Ready Bit (CR8). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Burst Type Bit (CR7). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Valid Clock Edge Bit (CR6). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Burst Length Bit (CR2-CR0). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Table 3. Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Table 4. Burst Type Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Figure 6. Burst Configuration X-1-1-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Figure 7. Burst Configuration X-2-2-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 COMMAND INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Read Memory Array Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Read Electronic Signature Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Read Query Command.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Read Status Register Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Clear Status Register Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Block Erase Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Word Program Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Write to Buffer and Program Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Program/Erase Suspend Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Program/Erase Resume Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Set Configuration Register Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Block Protect Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Blocks Unprotect Command.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Protection Register Program Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Configure STS Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Table 5. Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Table 6. Configuration Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Table 7. Read Electronic Signature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Table 8. Read Protection Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Figure 8. Protection Register Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Table 9. Program, Erase Times and Program Erase Endurance Cycles . . . . . . . . . . . . . . . . . . . 25 STATUS REGISTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Program/Erase Controller Status Bit (SR7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Erase Suspend Status Bit ( SR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Erase Status Bit (SR5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Program Status Bit (SR4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 VPEN Status Bit (SR3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Program Suspend Status Bit (SR2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Block Protection Status Bit (SR1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3/61 M58LW032C Reserved (SR0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Table 10. Status Register Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 MAXIMUM RATING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Table 11. Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 DC and AC PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Table 12. Operating and AC Measurement Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Figure 9. AC Measurement Input Output Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Figure 10. AC Measurement Load Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Table 13. Capacitance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Table 14. DC Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Figure 11. Asynchronous Bus Read AC Waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 15. Asynchronous Bus Read AC Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Figure 12. Asynchronous Latch Controlled Bus Read AC Waveforms . . . . . . . . . . . . . . . . . . . . . 33 Table 16. Asynchronous Latch Controlled Bus Read AC Characteristics . . . . . . . . . . . . . . . . . . . 33 Figure 13. Asynchronous Page Read AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Table 17. Asynchronous Page Read AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Figure 14. Asynchronous Write AC Waveform, Write Enable Controlled . . . . . . . . . . . . . . . . . . . 35 Figure 15. Asynchronous Latch Controlled Write AC Waveform, Write Enable Controlled . . . . . . 35 Table 18. Asynchronous Write and Latch Controlled Write AC Characteristics, Write Enable Controlled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Figure 16. Asynchronous Write AC Waveforms, Chip Enable Controlled . . . . . . . . . . . . . . . . . . . 37 Figure 17. Asynchronous Latch Controlled Write AC Waveforms, Chip Enable Controlled . . . . . 37 Table 19. Asynchronous Write and Latch Controlled Write AC Characteristics, Chip Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Figure 18. Synchronous Burst Read AC Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Figure 19. Synchronous Burst Read - Continuous - Valid Data Ready Output . . . . . . . . . . . . . . . 40 Table 20. Synchronous Burst Read AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Figure 20. Reset, Power-Down and Power-up AC Waveform. . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Table 21. Reset, Power-Down and Power-up AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . 41 PACKAGE MECHANICAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Figure 21. TSOP56 - 56 lead Plastic Thin Small Outline, 14 x 20 mm, Package Outline . . . . . . . Table 22. TSOP56 - 56 lead Plastic Thin Small Outline, 14 x 20 mm, Package Mechanical Data Figure 22. TBGA64 10x13mm - 8x8 ball array, 1mm pitch, Package Outline . . . . . . . . . . . . . . . . Table 23. TBGA64 10x13mm - 8x8 ball array, 1mm pitch, Package Mechanical Data . . . . . . . . . 42 42 43 43 PART NUMBERING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Table 24. Ordering Information Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 APPENDIX A. BLOCK ADDRESS TABLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Table 25. Block Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 APPENDIX B. COMMON FLASH INTERFACE - CFI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Table 26. Query Structure Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 4/61 M58LW032C Table 27. CFI - Query Address and Data Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 28. CFI - Device Voltage and Timing Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 29. Device Geometry Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 30. Block Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 31. Extended Query information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 47 47 48 49 APPENDIX C. FLOW CHARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Figure 23. Write to Buffer and Program Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . Figure 24. Program Suspend & Resume Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . Figure 25. Erase Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 26. Erase Suspend & Resume Flowchart and Pseudo Code. . . . . . . . . . . . . . . . . . . . . . . Figure 27. Block Protect Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 28. Blocks Unprotect Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 29. Protection Register Program Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . Figure 30. Command Interface and Program Erase Controller Flowchart (a) . . . . . . . . . . . . . . . . Figure 31. Command Interface and Program Erase Controller Flowchart (b) . . . . . . . . . . . . . . . . Figure 32. Command Interface and Program Erase Controller Flowchart (c). . . . . . . . . . . . . . . . 50 51 52 53 54 55 56 57 58 59 REVISION HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Table 32. Document Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 5/61 M58LW032C SUMMARY DESCRIPTION M58LW032C is a 32 Mbit (2Mb x16) non-volatile memory that can be read, erased and reprogrammed. These operations can be performed using a single low voltage (2.7V to 3.6V) core supply. On power-up the memory defaults to Read mode with an asynchronous bus where it can be read in the same way as a non-burst Flash memory. The memory is divided into 32 blocks of 1Mbit that can be erased independently so it is possible to preserve valid data while old data is erased. Program and Erase commands are written to the Command Interface of the memory. An on-chip Program/Erase Controller simplifies the process of programming or erasing the memory by taking care of all of the special operations that are required to update the memory contents. The end of a Program or Erase operation can be detected and any error conditions identified in the Status Register. The command set required to control the memory is consistent with JEDEC standards. The device supports synchronous burst read and asynchronous read from all blocks of the memory array; at power-up the device is configured for asynchronous read. In asynchronous mode an Address Latch input can be used to latch addresses in Latch Controlled mode. In synchronous burst mode, data is output on each clock cycle at frequencies of up to 56MHz. The Write Buffer allows the microprocessor to program from 1 to 16 Words in parallel, both speeding up the programming and freeing up the microprocessor to perform other work. A Word Program command is available to program a single Word. Erase can be suspended in order to perform either Read or Program in any other block and then resumed. Program can be suspended to Read data in any other block and then resumed. Each block can be programmed and erased over 100,000 cycles. The M58LW032C has several security features to increase data protection. 6/61 Block Protection, where each block can be individually protected against program or erase operations. All blocks are protected during power-up. The protection of the blocks is nonvolatile; after power-up the protection status of each block is restored to the state when power was last removed. ■ Program Erase Enable input VPEN, program or erase operations are not possible when the Program Erase Enable input VPEN is low. ■ Smart Protection, which allows protected blocks to be permanently locked. This feature is not described in the datasheet for security reasons. Please contact STMicroelectronics for further details. ■ 128 bit Protection Register, divided into two 64 bit segments: the first contains a unique device number written by ST, the second is user programmable. The user programmable segment can be protected. The Reset/Power-Down pin is used to apply a Hardware Reset to the memory and to set the device in power-down mode. The device features an Auto Low Power mode. If the bus becomes inactive during Asynchronous Read operations, the device automatically enters Auto Low Power mode. In this mode the power consumption is reduced to the Auto Low Power supply current. The STS signal is an open drain output that can be used to identify the Program/Erase Controller status. It can be configured in two modes: Ready/ Busy mode where a static signal indicates the status of the P/E.C, and Status mode where a pulsing signal indicates the end of a Program or Block Erase operation. In Status mode it can be used as a system interrupt signal, useful for saving CPU time. The memory is available in TSOP56 (14 x 20 mm) and TBGA64 (10 x 13mm, 1mm pitch) packages. ■ M58LW032C Figure 2. Logic Diagram Table 1. Signal Names A1-A21 Address inputs DQ0-DQ15 Data Inputs/Outputs E Chip Enable G Output Enable K Clock L Latch Enable R Valid Data Ready STS Status/(Ready/Busy) RP Reset/Power-Down STS VPEN Program/Erase Enable R W Write Enable VDD Supply Voltage VDDQ Input/Output Supply Voltage VSS Ground VSSQ Input/Output Ground NC Not Connected Internally VDD VDDQ 21 A1-A21 VPEN 16 W E DQ0-DQ15 M58LW032C G RP L K VSS VSSQ AI06208 7/61 M58LW032C Figure 3. TSOP56 Connections NC R A21 A20 A19 A18 A17 A16 VDD A15 A14 A13 A12 E VPEN RP A11 A10 A9 A8 VSS A7 A6 A5 A4 A3 A2 A1 1 56 14 43 M58LW032C 15 42 28 29 NC W G STS DQ15 DQ7 DQ14 DQ6 VSS DQ13 DQ5 DQ12 DQ4 VDDQ VSSQ DQ11 DQ3 DQ10 DQ2 VDD DQ9 DQ1 DQ8 DQ0 NC K NC L AI06209 8/61 M58LW032C Figure 4. TBGA64 Connections (Top view through package) 1 2 3 4 5 6 7 8 A A1 A6 A8 VPEN A13 VDD A18 NC B A2 VSS A9 E A14 NC A19 R C A3 A7 A10 A12 A15 NC A20 A21 D A4 A5 A11 RP NC NC A16 A17 E DQ8 DQ1 DQ9 DQ3 DQ4 NC DQ15 STS F K DQ0 DQ10 DQ11 DQ12 NC NC G G NC NC DQ2 VDDQ DQ5 DQ6 DQ14 W H L NC VDD VSS DQ13 VSSQ DQ7 NC AI06210b 9/61 M58LW032C Figure 5. Block Addresses Word (x16) Bus Width 1FFFFFh 1F0000h 1EFFFFh 1 Mbit or 64 KWords 1 Mbit or 64 KWords 1E0000h Total of 32 1 Mbit Blocks 01FFFFh 010000h 00FFFFh 1 Mbit or 64 KWords 1 Mbit or 64 KWords 000000h AI06254 Note: Also see Appendix A, Table 25 for a full listing of the Block Addresses. 10/61 M58LW032C SIGNAL DESCRIPTIONS See Figure 2, Logic Diagram and Table 11, Signal Names, for a brief overview of the signals connected to this device. Address Inputs (A1-A21). The Address Inputs are used to select the cells to access in the memory array during Bus Read operations either to read or to program data to. During Bus Write operations they control the commands sent to the Command Interface of the internal state machine. Chip Enable and Latch Enable must be low when selecting the addresses. The address inputs are latched on the rising edge of Chip Enable, Write Enable or Latch Enable, whichever occurs first in a Write operation. The address latch is transparent when Latch Enable is low, VIL. The address is internally latched in an Erase or Program operation. Data Inputs/Outputs (DQ0-DQ15). The Data Inputs/Outputs output the data stored at the selected address during a Bus Read operation, or are used to input the data during a program operation. During Bus Write operations they represent the commands sent to the Command Interface of the internal state machine. When used to input data or Write commands they are latched on the rising edge of Write Enable or Chip Enable, whichever occurs first. When Chip Enable and Output Enable are both low, V IL, the data bus outputs data from the memory array, the Electronic Signature, the Block Protection status, the CFI Information or the contents of the Status Register. The data bus is high impedance when the chip is deselected, Output Enable is high, VIH, or the Reset/Power-Down signal is low, V IL. When the Program/Erase Controller is active the Ready/Busy status is given on DQ7. Chip Enable (E). The Chip Enable, E, input activates the memory control logic, input buffers, decoders and sense amplifiers. Chip Enable, E, at VIH deselects the memory and reduces the power consumption to the Standby level, IDD1. Output Enable (G). The Output Enable, G, gates the outputs through the data output buffers during a read operation. When Output Enable, G, is at VIH the outputs are high impedance. Output Enable, G, can be used to inhibit the data output during a burst read operation. Write Enable (W). The Write Enable input, W, controls writing to the Command Interface, Input Address and Data latches. Both addresses and data can be latched on the rising edge of Write Enable (also see Latch Enable, L). Reset/PowerReset/Power-Down (RP). The Down pin can be used to apply a Hardware Reset to the memory. A Hardware Reset is achieved by holding Reset/ Power-Down Low, VIL, for at least tPLPH. When Reset/Power-Down is Low, VIL, the Status Register information is cleared and the power consumption is reduced to power-down level. The device is deselected and outputs are high impedance. If Reset/Power-Down goes low, V IL,during a Block Erase, a Write to Buffer and Program or a Block Protect/Unprotect the operation is aborted and the data may be corrupted. In this case the Ready/ Busy pin stays low, V IL, for a maximum timing of tPLPH + tPHRH, until the completion of the Reset/ Power-Down pulse. After Reset/Power-Down goes High, V IH, the memory will be ready for Bus Read and Bus Write operations after tPHQV. Note that Ready/Busy does not fall during a reset, see Ready/Busy Output section. In an application, it is recommended to associate Reset/Power-Down pin, RP, with the reset signal of the microprocessor. Otherwise, if a reset operation occurs while the memory is performing an Erase or Program operation, the memory may output the Status Register information instead of being initialized to the default Asynchronous Random Read. Latch Enable (L). The Bus Interface is configured to latch the Address Inputs on the rising edge of Latch Enable, L. In synchronous bus operations the address is latched on the active edge of the Clock when Latch Enable is Low, V IL or on the rising of Latch Enable, whichever occurs first. Once latched, the addresses may change without affecting the address used by the memory. When Latch Enable is Low, VIL, the latch is transparent. Clock (K). The Clock, K, is used to synchronize the memory with the external bus during Synchronous Bus Read operations. The Clock can be configured to have an active rising or falling edge. Bus signals are latched on the active edge of the Clock during synchronous bus operations. In Synchronous Burst Read mode the address is latched on the first active clock edge when Latch Enable is low, VIL, or on the rising edge of Latch Enable, whichever occurs first. During asynchronous bus operations the Clock is not used. Valid Data Ready (R). The Valid Data Ready output, R, is an open drain output that can be used to identify if the memory is ready to output data or not. The Valid Data Ready output is only active during Synchronous Burst Read operations when the Burst Length is set to Continuous. The Valid Data Ready output can be configured to be active on the clock edge of the invalid data read cycle or one cycle before. Valid Data Ready Low, V OL, in- 11/61 M58LW032C dicates that the data is not, or will not be valid. Valid Data Ready in a high-impedance state indicates that valid data is or will be available. Unless Synchronous Burst Read has been selected, Valid Data Ready is high-impedance. It may be tied to other components with the same Valid Data Ready signal to create a unique System Ready signal. The Valid Data Ready, R, output has an internal pull-up resistor of approximately 1 MΩ powered from VDDQ, designers should use an external pullup resistor of the correct value to meet the external timing requirements for Valid Data Ready rising. Refer to Figure 19. Status/(Ready/Busy) (STS). The STS signal is an open drain output that can be used to identify the Program/Erase Controller status. It can be configured in two modes: ■ Ready/Busy - the pin is Low, VOL, during Program and Erase operations and high impedance when the memory is ready for any Read, Program or Erase operation. ■ Status - the pin gives a pulsing signal to indicate the end of a Program or Block Erase operation. After power-up or reset the STS pin is configured in Ready/Busy mode. The pin can be configured for Status mode using the Configure STS command. When the Program/Erase Controller is idle, or suspended, STS can float High through a pull-up resistor. The use of an open-drain output allows the STS pins from several memories to be connected to a single pull-up resistor (a Low will indicate that one, or more, of the memories is busy). 12/61 STS is not Low during a reset unless the reset was applied when the Program/Erase controller was active. Ready/Busy can rise before Reset/PowerDown rises. Program/Erase Enable (VPEN). The Program/ Erase Enable input, VPEN, is used to protect all blocks, preventing Program and Erase operations from affecting their data. Program/Erase Enable must be kept High during all Program/Erase Controller operations, otherwise the operations is not guaranteed to succeed and data may become corrupt. VDD Supply Voltage. VDD provides the power supply to the internal core of the memory device. It is the main power supply for all operations (Read, Program and Erase). VDDQ Supply Voltage. VDDQ provides the power supply to the I/O pins and enables all Outputs to be powered independently from VDD. VDDQ can be tied to VDD or can use a separate supply. It is recommended to power-up and power-down VDD and VDDQ together to avoid any condition that would result in data corruption. VSS Ground. Ground, VSS, is the reference for the core power supply. It must be connected to the system ground. VSSQ Ground. VSSQ ground is the reference for the input/output circuitry driven by V DDQ. VSSQ must be connected to V SS. Note: Each device in a system should have VDD and VDDQ decoupled with a 0.1µF ceramic capacitor close to the pin (high frequency, inherently low inductance capacitors should be as close as possible to the package). See Figure 10, AC Measurement Load Circuit. M58LW032C BUS OPERATIONS There are six standard bus operations that control the device. These are Address Latch, Bus Read, Bus Write, Output Disable, Power-Down and Standby. See Table 2, Bus Operations, for a summary. Typically glitches of less than 5ns on Chip Enable or Write Enable are ignored by the memory and do not affect Bus Write operations. Address Latch. Address latch operations input valid addresses. A valid bus operation involves setting the desired address on the Address Inputs, setting Chip Enable and Latch Enable Low, V IL and keeping Write Enable High, VIH; the address is latched on the rising edge of Address Latch. Bus Read. Bus Read operations are used to output the contents of the Memory Array, the Electronic Signature, the Status Register, the Common Flash Interface and the Block Protection Status. A valid bus operation involves setting the desired address on the Address Inputs, applying a Low signal, V IL, to Chip Enable, Output Enable and Latch Enable and keeping Write Enable High, V IH. The data read depends on the previous command written to the memory (see Command Interface section). See Figures 11, 12, 13, 18 and 19 Read AC Waveforms, and Tables 15, 16, 17 and 20 Read AC Characteristics, for details of when the output becomes valid. Bus Write. Bus Write operations write Commands to the memory or latch addresses and input data to be programmed. A valid Bus Write operation begins by setting the desired address on the Address Inputs and setting Latch Enable Low, V IL. The Address Inputs are latched by the Command Interface on the rising edge of Chip Enable or Write Enable, whichever occurs first. The Data Inputs/Outputs are latched by the Command Interface on the rising edge of Chip Enable or Write Enable, whichever occurs first. Output Enable must remain High, V IH, during the Bus Write operation. See Figures 14, 15, 16 and 17, Write AC Waveforms, and Tables 18 and 19, Write AC Characteristics, for details of the timing requirements. Output Disable. The The Data Inputs/Outputs are high impedance when the Output Enable is at VIH. Power-Down. The memory is in Power-Down mode when Reset/Power-Down, RP, is Low. The power consumption is reduced to the Power-Down level, IDD2, and the outputs are high impedance, independent of Chip Enable, Output Enable or Write Enable. Standby. Standby disables most of the internal circuitry, allowing a substantial reduction of the current consumption. The memory is in standby when Chip Enable is at VIH. The power consumption is reduced to the standby level IDD1 and the outputs are set to high impedance, independently from the Output Enable or Write Enable inputs. If Chip Enable switches to V IH during a program or erase operation, the device enters Standby mode when finished. Table 2. Bus Operations Operation E G W RP L A1-A21 DQ0-DQ15 Address Latch VIL X VIH VIH VIL Address Data Output or Hi-Z (2) Bus Read VIL VIL VIH VIH VIL Address Data Output Bus Write VIL VIH VIL VIH VIL Address Data Input Output Disable VIL VIH VIH VIH X X High Z Power-Down X X X VIL X X High Z Standby VIH X X VIH X X High Z Note: 1. X = Don’t Care VIL or VIH . 2. Depends on G 13/61 M58LW032C READ MODES Read operations can be performed in two different ways depending on the settings in the Configuration Register. If the clock signal is ‘don’t care’ for the data output, the read operation is asynchronous; if the data output is synchronized with clock, the read operation is synchronous. The read mode and format of the data output are determined by the Configuration Register. (See Configuration Register section for details). On Power-up or after a Hardware Reset the memory defaults to Asynchronous Read mode. Asynchronous Read Modes In Asynchronous Read operations the clock signal is ‘don’t care’. The device outputs the data corresponding to the address latched, that is the memory array, Status Register, Common Flash Interface, Electronic Signature or Block Protection Status depending on the command issued. CR15 in the Configuration Register must be set to ‘1’ for asynchronous operations. During Asynchronous Read operations, if the bus is inactive for a time equivalent to tAVQV, the device automatically enters Auto Low Power mode. In this mode the internal supply current is reduced to the Auto Low Power supply current, IDD5. The Data Inputs/Outputs will still output data if a Bus Read operation is in progress. Automatic Low Power is only available in Asynchronous Read modes. Asynchronous Read operations can be performed in three different ways, Asynchronous Latch Controlled Read, Asynchronous Random Read and Asynchronous Page Read. Asynchronous Latch Controlled Read. In Asynchronous Latch Controlled Read operations read the address is latched in the memory before the value is output on the data bus, allowing the address to change during the cycle without affecting the address that the memory uses. A valid bus operation involves setting the desired address on the Address Inputs, setting Chip Enable and Latch Enable Low, V IL and keeping Write Enable High, VIH; the address is latched on the rising edge of Address Latch. Once latched, the Address Inputs can change. Set Output Enable Low, VIL, to read the data on the Data Inputs/Outputs; see Figure 12, Asynchronous Latch Controlled Read AC Waveforms and Table 16, Asynchronous Latch Controlled Read AC Characteristics for details on when the output becomes valid. See Figures 12, Asynchronous Latch Controlled Read AC Waveforms, and Table 16, Asynchronous Latch Controlled Read AC Characteristics, for details. 14/61 Asynchronous Random Read. As the Latch Enable input is transparent when set Low, V IL, Asynchronous Random Read operations can be performed by holding Latch Enable Low, VIL throughout the bus operation. See Figures 11, Asynchronous Random Read AC Waveforms, and Table 15, Asynchronous Random Read AC Characteristics, for details. Asynchronous Page Read. In Asynchronous Page Read mode a Page of data is internally read and stored in a Page Buffer. Each memory page is 4 Words and has the same A3-A22, only A1 and A2 may change. The first read operation within the Page has the normal access time (tAVQV), subsequent reads within the same Page have much shorter access times (tAVQV1). If the Page changes then the normal, longer timings apply again. See Figures 13, Asynchronous Page Read AC Waveforms, and Table 17, Asynchronous Page Read AC Characteristics, for details. Synchronous Read Modes In Synchronous Read mode the data output is synchronized with the clock. CR15 in the Configuration Register must be set to ‘0’ for synchronous operations. Synchronous Burst Read. In Synchronous Burst Read mode the data is output in bursts synchronized with the clock. It is possible to perform burst reads across bank boundaries. Synchronous Burst Read mode can only be used to read the memory array. For other read operations, such as Read Status Register, Read CFI, Read Electronic Signature and Block Protection Status, Single Synchronous Read or Asynchronous Read must be used. In Synchronous Burst Read mode the flow of the data output depends on parameters that are configured in the Configuration Register. A valid Synchronous Burst Read operation begins when the address is set on the Address Inputs, Write Enable is High, VIH, and Chip Enable and Latch Enable are Low, V IL, during the active edge of the Clock. The address is latched on the first active clock edge when Latch Enable is low, or on the rising edge of Latch Enable, whichever occurs first. The data becomes available for output after the X-latency specified in the Burst Control Register has expired. The output buffers are activated by setting Output Enable Low, V IL. See Figures 6 and 7 for examples of Synchronous Burst Read operations. The number of Words to be output during a Synchronous Burst Read operation can be configured as 4 Words, 8 Words or Continuous (Burst Length M58LW032C bits CR2-CR0). In Synchronous Continuous Burst Read mode one Burst Read operation can access the entire memory sequentially. If the starting address is not associated with a page (4 Word) boundary the Valid Data Ready, R, output goes Low, V IL, to indicate that the data will not be ready in time and additional wait-states are required. The Valid Data Ready output timing (bit CR8) can be changed in the Configuration Register. The order of the data output can be modified through the Burst Type bit in the Configuration Register. The burst sequence can be sequential or interleaved. See Table 20, Synchronous Read AC Characteristics and Figure 18 and 19, Synchronous Burst Read AC Waveform for details. Single Synchronous Read. Single Synchronous Read operations are similar to Synchronous Burst Read operations except that only the first data output after the X latency is valid. Single Synchronous Reads are used to read the Status Register, CFI, Electronic Signature and Block Protection Status. 15/61 M58LW032C CONFIGURATION REGISTER The Configuration Register is used to configure the type of bus access that the memory will perform. The Configuration Register bits are described in Table 3. They specify the selection of the burst length, burst type, burst X and Y latencies and the Read operation. See figures 6 and 7 for examples of Synchronous Burst Read configurations. The Configuration Register is set through the Command Interface and will retain its information until it is re-configured, the device is reset, or the device goes into Reset/Power-Down mode. The Configuration Register is read using the Read Electronic Signature Command at address 05h. Read Select Bit (CR15). The Read Select bit, CR15, is used to switch between asynchronous and synchronous Bus Read operations. When the Read Select bit is set to ’1’, Bus Read operations are asynchronous; when the Read Select but is set to ’0’, Bus Read operations are synchronous. On reset or power-up the Read Select bit is set to ’1’ for asynchronous access. X-Latency Bits (CR13-CR11). The X-Latency bits are used during Synchronous Bus Read operations to set the number of clock cycles between the address being latched and the first data becoming available. For correct operation the X-Latency bits can only assume the values in Table 3, Configuration Register. Internal Clock Divider Bit (CR10). The Internal Clock Divider Bit is used to divide the internal clock by two. When CR10 is set to ‘1’ the internal clock is divided by two, which effectively means that the X and Y-Latency values are multiplied by two, that is the number of clock cycles between the address being latched and the first data becoming available will be twice the value set in CR13-CR11, and the number of clock cycles between consecutive reads will be twice the value set in CR9. For example 8-1-1-1 will become 16-2-2-2. When CR10 is set to ‘0’ the internal clock runs normally and the X and Y-Latency values are those set in CR13-CR11 and CR9. Y-Latency Bit (CR9). The Y-Latency bit is used during Synchronous Bus Read operations to set 16/61 the number of clock cycles between consecutive reads. The Y-Latency value depends on both the X-Latency value and the setting in CR9. When the Y-Latency is 1 the data changes each clock cycle; when the Y-Latency is 2 the data changes every second clock cycle. See Table 3, Configuration Register for valid combinations of the Y-Latency, the X-Latency and the Clock frequency. Valid Data Ready Bit (CR8). The Valid Data Ready bit controls the timing of the Valid Data Ready output pin, R. When the Valid Data Ready bit is ’0’ the Valid Data Ready output pin is driven Low for the active clock edge when invalid data is output on the bus. When the Valid Data Ready bit is ’1’ the Valid Data Ready output pin is driven Low one clock cycle prior to invalid data being output on the bus. Burst Type Bit (CR7). The Burst Type bit is used to configure the sequence of addresses read as sequential or interleaved. When the Burst Type bit is ’0’ the memory outputs from interleaved addresses; when the Burst Type bit is ’1’ the memory outputs from sequential addresses. See Tables 4, Burst Type Definition, for the sequence of addresses output from a given starting address in each mode. Valid Clock Edge Bit (CR6). The Valid Clock Edge bit, CR6, is used to configure the active edge of the Clock, K, during Synchronous Burst Read operations. When the Valid Clock Edge bit is ’0’ the falling edge of the Clock is the active edge; when the Valid Clock Edge bit is ’1’ the rising edge of the Clock is active. Burst Length Bit (CR2-CR0). The Burst Length bits set the maximum number of Words that can be output during a Synchronous Burst Read operation. Table 3, Configuration Register gives the valid combinations of the Burst Length bits that the memory accepts; Tables 4, Burst Type Definition, give the sequence of addresses output from a given starting address for each length. CR5 CR4 and CR3 are reserved for future use. M58LW032C Table 3. Configuration Register Address Bit Mnemonic Bit Name Reset Value 16 CR15 Read Select 1 15 14 to 12 11 10 9 8 7 6 to 4 3 to 1 Value 0 Synchronous Burst Read 1 Asynchronous Bus Read (default at power-up) CR14 CR13-CR11 CR10 CR9 CR8 CR7 CR6 Reserved X-Latency(2) Internal Clock Divider Reserved 010 X-Latency = 4, 4-1-1-1 (use only with Y-Latency = 1)(1) 011 X-Latency = 5, 5-1-1-1, 5-2-2-2 100 X-Latency = 6, 6-1-1-1, 6-2-2-2 101 X-Latency = 7, 7-1-1-1, 7-2-2-2 110 X-Latency = 8, 8-1-1-1, 8-2-2-2 XXX 0 X and Y-Latencies remains as set in CR13-CR11 and CR9 1 Divides internal clock, X and Y-Latencies multiplied by 2 0 Y-Latency = 1 1 Y-Latency = 2 0 R valid Low during valid Clock edge 1 R valid Low one cycle before valid Clock edge 0 Interleaved 1 Sequential 0 Falling Clock edge 1 Rising Clock edge X Y-Latency(3) X Valid Data Ready X Burst Type X Valid Clock Edge 001 X CR5-CR3 CR2-CR0 Description Reserved Burst Length XXX 001 4 Words 010 8 Words 111 Continuous Note: 1. 4 - 2 - 2 - 2 (represents X-Y-Y-Y) is not allowed. 2. X latencies can be calculated as: (t AVQV – tLLKH + tQVKH) + tSYSTEM MARGIN < (X -1) tK. (X is an integer number from 4 to 8 and tK is the clock period). 3. Y latencies can be calculated as: tKHQV + tSYSTEM MARGIN + tQVKH < Y tK. 4. tSYSTEM MARGIN is the time margin required for the calculation. 17/61 M58LW032C Table 4. Burst Type Definition Starting Address x4 Sequential x4 Interleaved x8 Sequential x8 Interleaved Continuous 0 0-1-2-3 0-1-2-3 0-1-2-3-4-5-6-7 0-1-2-3-4-5-6-7 0-1-2-3-4-5-6-7-8-9-10.. 1 1-2-3-0 1-0-3-2 1-2-3-4-5-6-7-0 1-0-3-2-5-4-7-6 1-2-3-4-5-6-7-8-9-10-11.. 2 2-3-0-1 2-3-0-1 2-3-4-5-6-7-0-1 2-3-0-1-6-7-4-5 2-3-4-5-6-7-8-9-10-11-12.. 3 3-0-1-2 3-2-1-0 3-4-5-6-7-0-1-2 3-2-1-0-7-6-5-4 3-4-5-6-7-8-9-10-11-12-13.. 4 – – 4-5-6-7-0-1-2-3 4-5-6-7-0-1-2-3 4-5-6-7-8-9-10-11-2-13-14.. 5 – – 5-6-7-0-1-2-3-4 5-4-7-6-1-0-3-2 5-6-7-8-9-10-11-12-13-14.. 6 – – 6-7-0-1-2-3-4-5 6-7-4-5-2-3-0-1 6-7-8-9-10-11-12-13-14-15.. 7 – – 7-0-1-2-3-4-5-6 7-6-5-4-3-2-1-0 7-8-9-10-11-12-13-14-15-16.. 8 – – – – 8-9-10-11-12-13-14-15-16-17.. Figure 6. Burst Configuration X-1-1-1 0 1 2 3 4 5 6 7 8 9 K ADD VALID L DQ 4-1-1-1 DQ DQ DQ DQ 5-1-1-1 6-1-1-1 7-1-1-1 8-1-1-1 VALID VALID VALID VALID VALID VALID VALID VALID VALID VALID VALID VALID VALID VALID VALID VALID VALID VALID VALID VALID AI05512 18/61 M58LW032C Figure 7. Burst Configuration X-2-2-2 0 1 2 3 4 5 6 7 8 9 K ADD VALID L DQ DQ DQ DQ NV 5-2-2-2 6-2-2-2 VALID NV VALID NV VALID NV VALID NV VALID NV NV VALID NV VALID NV VALID NV 7-2-2-2 8-2-2-2 NV=NOT VALID AI05513 19/61 M58LW032C COMMAND INTERFACE All Bus Write operations to the memory are interpreted by the Command Interface. Commands consist of one or more sequential Bus Write operations. The Commands are summarized in Table 5, Commands. Refer to Table 5 in conjunction with the text descriptions below. After power-up or a Reset operation the memory enters Read mode. Synchronous Read operations and Latch Controlled Bus Read operations can only be used to read the memory array. The Electronic Signature, CFI or Status Register will be read in asynchronous mode or single synchronous burst mode. Once the memory returns to Read Memory Array mode the bus will resume the setting in the Configuration Register automatically. Read Memory Array Command. The Read Memory Array command returns the memory to Read mode. One Bus Write cycle is required to issue the Read Memory Array command and return the memory to Read mode. Once the command is issued the memory remains in Read mode until another command is issued. From Read mode Bus Read commands will access the memory array. While the Program/Erase Controller is executing a Program, Erase, Block Protect, Blocks Unprotect or Protection Register Program operation the memory will not accept the Read Memory Array command until the operation completes. Read Electronic Signature Command. The Read Electronic Signature command is used to read the Manufacturer Code, the Device Code, the Block Protection Status, the Configuration Register and the Protection Register. One Bus Write cycle is required to issue the Read Electronic Signature command. Once the command is issued subsequent Bus Read operations read the Manufacturer Code, the Device Code, the Block Protection Status, the Configuration Register or the Protection Register until another command is issued. Refer to Table 7, Read Electronic Signature, Table 8, Read Protection Register and Figure 8, Protection Register Memory Map for information on the addresses. Read Query Command. The Read Query Command is used to read data from the Common Flash Interface (CFI) Memory Area. One Bus Write cycle is required to issue the Read Query Command. Once the command is issued subsequent Bus Read operations read from the Common Flash Interface Memory Area. See Appendix B, Tables 26, 27, 28, 29, 30 and 31 for details on the information contained in the Common Flash Interface (CFI) memory area. Read Status Register Command. The Read Status Register command is used to read the Status 20/61 Register. One Bus Write cycle is required to issue the Read Status Register command. Once the command is issued subsequent Bus Read operations read the Status Register until another command is issued. The Status Register information is present on the output data bus (DQ1-DQ7) when both Chip Enable and Output Enable are low, V IL. See the section on the Status Register and Table 10 for details on the definitions of the Status Register bits Clear Status Register Command. The Clear Status Register command can be used to reset bits SR1, SR3, SR4 and SR5 in the Status Register to ‘0’. One Bus Write is required to issue the Clear Status Register command. The bits in the Status Register are sticky and do not automatically return to ‘0’ when a new Write to Buffer and Program, Erase, Block Protect, Block Unprotect or Protection Register Program command is issued. If any error occurs then it is essential to clear any error bits in the Status Register by issuing the Clear Status Register command before attempting a new Program, Erase or Resume command. Block Erase Command. The Block Erase command can be used to erase a block. It sets all of the bits in the block to ‘1’. All previous data in the block is lost. If the block is protected then the Erase operation will abort, the data in the block will not be changed and the Status Register will output the error. Two Bus Write operations are required to issue the command; the second Bus Write cycle latches the block address in the internal state machine and starts the Program/Erase Controller. Once the command is issued subsequent Bus Read operations read the Status Register. See the section on the Status Register for details on the definitions of the Status Register bits. During the Erase operation the memory will only accept the Read Status Register command and the Program/Erase Suspend command. All other commands will be ignored. Typical Erase times are given in Table 9. See Appendix C, Figure 25, Block Erase Flowchart and Pseudo Code, for a suggested flowchart on using the Block Erase command. Word Program Command. The Word Program command is used to program a single word in the memory array. Two Bus Write operations are required to issue the command; the first write cycle sets up the Word Program command, the second write cycle latches the address and data to be programmed in the internal state machine and starts the Program/Erase Controller. M58LW032C If the block being programmed is protected an error will be set in the Status Register and the operation will abort without affecting the data in the memory array. The block must be unprotected using the Blocks Unprotect command. Write to Buffer and Program Command. The Write to Buffer and Program command is used to program the memory array. Up to 16 Words can be loaded into the Write Buffer and programmed into the memory. Each Write Buffer has the same A5-A21 addresses. Four successive steps are required to issue the command. 1. One Bus Write operation is required to set up the Write to Buffer and Program Command. Issue the set up command with the selected memory Block Address where the program operation should occur (any address in the block where the values will be programmed can be used). Any Bus Read operations will start to output the Status Register after the 1st cycle. 2. Use one Bus Write operation to write the same block address along with the value N on the Data Inputs/Output, where N+1 is the number of Words to be programmed. 3. Use N+1 Bus Write operations to load the address and data for each Word into the Write Buffer. See the constraints on the address combinations listed below. The addresses must have the same A5-A21. 4. Finally, use one Bus Write operation to issue the final cycle to confirm the command and start the Program operation. Invalid address combinations or failing to follow the correct sequence of Bus Write cycles will set an error in the Status Register and abort the operation without affecting the data in the memory array. The Status Register should be cleared before re-issuing the command. If the block being programmed is protected an error will be set in the Status Register and the operation will abort without affecting the data in the memory array. The block must be unprotected using the Blocks Unprotect command. See Appendix C, Figure 23, Write to Buffer and Program Flowchart and Pseudo Code, for a suggested flowchart on using the Write to Buffer and Program command. Program/Erase Suspend Command. The Program/Erase Suspend command is used to pause a Word Program, Write to Buffer and Program or Erase operation. The command will only be accepted during a Program or an Erase operation. It can be issued at any time during an Erase operation but will only be accepted during a Word Pro- gram or Write to Buffer and Program command if the Program/Erase Controller is running. One Bus Write cycle is required to issue the Program/Erase Suspend command and pause the Program/Erase Controller. Once the command is issued it is necessary to poll the Program/Erase Controller Status bit (SR7) to find out when the Program/Erase Controller has paused; no other commands will be accepted until the Program/ Erase Controller has paused. After the Program/ Erase Controller has paused, the memory will continue to output the Status Register until another command is issued. During the polling period between issuing the Program/Erase Suspend command and the Program/ Erase Controller pausing it is possible for the operation to complete. Once the Program/Erase Controller Status bit (SR7) indicates that the Program/Erase Controller is no longer active, the Program Suspend Status bit (SR2) or the Erase Suspend Status bit (SR6) can be used to determine if the operation has completed or is suspended. For timing on the delay between issuing the Program/Erase Suspend command and the Program/Erase Controller pausing see Table 9. During Program/Erase Suspend the Read Memory Array, Read Status Register, Read Electronic Signature, Read Query and Program/Erase Resume commands will be accepted by the Command Interface. Additionally, if the suspended operation was Erase then the Write to Buffer and Program, and the Program Suspend commands will also be accepted. When a program operation is completed inside a Block Erase Suspend the Read Memory Array command must be issued to reset the device in Read mode, then the Erase Resume command can be issued to complete the whole sequence. Only the blocks not being erased may be read or programmed correctly. See Appendix C, Figure 24, Program Suspend & Resume Flowchart and Pseudo Code, and Figure 26, Erase Suspend & Resume Flowchart and Pseudo Code, for suggested flowcharts on using the Program/Erase Suspend command. Program/Erase Resume Command. The Program/Erase Resume command can be used to restart the Program/Erase Controller after a Program/Erase Suspend operation has paused it. One Bus Write cycle is required to issue the Program/Erase Resume command. Once the command is issued subsequent Bus Read operations read the Status Register. Set Configuration Register Command. The Set Configuration Register command is used to write a new value to the Burst Configuration Control Register which defines the burst length, type, X and Y latencies, Synchronous/Asynchronous 21/61 M58LW032C Read mode and the valid Clock edge configuration. Two Bus Write cycles are required to issue the Set Configuration Register command. Once the command is issued the memory returns to Read mode as if a Read Memory Array command had been issued. The value for the Configuration Register is presented on A1-A16. CR0 is on A1, CR1 on A2, etc.; the other address bits are ignored. Block Protect Command. The Block Protect command is used to protect a block and prevent Program or Erase operations from changing the data in it. Two Bus Write cycles are required to issue the Block Protect command; the second Bus Write cycle latches the block address in the internal state machine and starts the Program/Erase Controller. Once the command is issued subsequent Bus Read operations read the Status Register. See the section on the Status Register for details on the definitions of the Status Register bits. During the Block Protect operation the memory will only accept the Read Status Register command. All other commands will be ignored. Typical Block Protection times are given in Table 9. The Block Protection bits are non-volatile, once set they remain set through reset and powerdown/power-up. They are cleared by a Blocks Unprotect command. See Appendix C, Figure 27, Block Protect Flowchart and Pseudo Code, for a suggested flowchart on using the Block Protect command. Blocks Unprotect Command. The Blocks Unprotect command is used to unprotect all of the blocks. Two Bus Write cycles are required to issue the Blocks Unprotect command; the second Bus Write cycle starts the Program/Erase Controller. Once the command is issued subsequent Bus Read operations read the Status Register. See the section on the Status Register for details on the definitions of the Status Register bits. During the Block Unprotect operation the memory will only accept the Read Status Register command. All other commands will be ignored. Typical Block Protection times are given in Table 9. See Appendix C, Figure 28, Block Unprotect Flowchart and Pseudo Code, for a suggested flowchart on using the Block Unprotect command. Protection Register Program Command. The Protection Register Program command is used to Program the 64 bit user segment of the Protection Register. The segment is programmed 16 bits at a 22/61 time. Two write cycles are required to issue the Protection Register Program command. ■ The first bus cycle sets up the Protection Register Program command. ■ The second latches the Address and the Data to be written to the Protection Register and starts the Program/Erase Controller. Read operations output the Status Register content after the programming has started. The user-programmable segment can be locked by programming bit 1 of the Protection Register Lock location to ‘0’ (see Table 8). Bit 0 of the Protection Register Lock location locks the factory programmed segment and is programmed to ‘0’ in the factory. The locking of the Protection Register is not reversible, once the lock bits are programmed no further changes can be made to the values stored in the Protection Register, see Figure 8, Protection Register Memory Map. Attempting to program a previously protected Protection Register will result in a Status Register error. The Protection Register Program cannot be suspended. See Appendix C, Figure 29, Protection Register Program Flowchart and Pseudo Code, for the flowchart for using the Protection Register Program command. Configure STS Command. The Configure STS command is used to configure the Status/(Ready/Busy) pin. After power-up or reset the STS pin is configured in Ready/Busy mode. The pin can be configured in Status mode using the Configure STS command (refer to Status/(Ready/Busy) section for more details. Two write cycles are required to issue the Configure STS command. ■ The first bus cycle sets up the Configure STS command. ■ The second specifies one of the four possible configurations (refer to Table 6, Configuration Codes): – Ready/Busy mode – Pulse on Erase complete mode – Pulse on Program complete mode – Pulse on Erase or Program complete mode The device will not accept the Configure STS command while the Program/Erase controller is busy or during Program/Erase Suspend. When STS pin is pulsing it remains Low for a typical time of 250ns. Any invalid Configuration Code will set an error in the Status Register. M58LW032C Command Cycles Table 5. Commands Bus Operations 1st Cycle Op. Addr. Data 2nd Cycle Subsequent Op. Addr. Data Read Memory Array ≥2 Write X FFh Read RA RD Read Electronic Signature ≥2 Write X 90h Read IDA(3) IDD(3) Read Status Register 2 Write X 70h Read X SRD Read Query ≥2 Write X 98h Read QA(4) QD(4) Clear Status Register 1 Write X 50h Block Erase 2 Write X 20h Write BA D0 Word Program 2 Write X 40h 10h Write PA PD BA E8h Write BA N Write to Buffer and Program 4 + N Write Program/Erase Suspend 1 Write X B0h Program/Erase Resume 1 Write X D0h Set Configuration Register 2 Write X 60h Write BCR 03h Block Protect 2 Write X 60h Write BA 01h Blocks Unprotect 2 Write X 60h Write X D0h Protection Register Program 2 Write X C0h Write PRA PRD Configure STS command 2 Write X B8h Write X CC Op. Write Final Addr. Data Op. Addr. Data PA PD Write X D0h Note: 1. X Don’t Care; RA Read Address, RD Read Data, IDA Identifier Address, IDD Identifier Data, SRD Status Register Data, PA Program Address; PD Program Data, QA Query Address, QD Query Data, BA Any address in the Block, BCR Configuration Register value, CC Configuration Code. 2. Base Address, refer to Figure 8 and Table 8 for more information. 3. For Identifier addresses and data refer to table 7, Read Electronic Signature. 4. For Query Address and Data refer to Appendix B, CFI. 23/61 M58LW032C Table 6. Configuration Codes Configuration Code DQ1 DQ2 Mode 00h 0 0 Ready/Busy 01h 0 1 Pulse on Erase complete 02h 1 0 Pulse on Program complete 03h 1 1 Pulse on Erase or Program complete STS Pin VOL during P/E operations Hi-Z when the memory is ready Description The STS pin is Low during Program and Erase operations and high impedance when the memory is ready for any Read, Program or Erase operation. Supplies a system interrupt pulse at the end of a Block Erase operation. Pulse Low then High when operation completed(2) Supplies a system interrupt pulse at the end of a Program operation. Supplies a system interrupt pulse at the end of a Block Erase or Program operation. Note: 1. DQ2-DQ7 are reserved 2. When STS pin is pulsing it remains Low for a typical time of 250ns. Table 7. Read Electronic Signature Code Address (A21-A1) Data (DQ15-DQ0) Manufacturer Code 000000h 0020h Device Code 000001h 8822h Block Protection Status SBA+02h 0000h (Block Unprotected) 0001h (Block Protected) Configuration Register 000005h BCR 000080h(2) PRD Protection Register Note: 1. SBA is the Start Base Address of each block, BCR is Configuration Register data, PRD is Protection Register Data. 2. Base Address, refer to Figure 8 and Table 8 for more information. Table 8. Read Protection Register Word Use A8 A7 A6 A5 A4 A3 A2 A1 Lock Factory, User 1 0 0 0 0 0 0 0 0 Factory (Unique ID) 1 0 0 0 0 0 0 1 1 Factory (Unique ID) 1 0 0 0 0 0 1 0 2 Factory (Unique ID) 1 0 0 0 0 0 1 1 3 Factory (Unique ID) 1 0 0 0 0 1 0 0 4 User 1 0 0 0 0 1 0 1 5 User 1 0 0 0 0 1 1 0 6 User 1 0 0 0 0 1 1 1 7 User 1 0 0 0 1 0 0 0 24/61 M58LW032C Figure 8. Protection Register Memory Map WORD ADDRESS 88h User Programmable 85h 84h Unique device number 81h 80h Protection Register Lock 1 0 AI05501 Table 9. Program, Erase Times and Program Erase Endurance Cycles M58LW032C Parameters Unit Typ(1,2) Max(2) Block (1Mb) Erase 1.2 4.8(4) s Chip Program (Write to Buffer) 24 72(4) s Chip Erase Time 37 110 (4) s 192 (3) 576 (4) µs Word/Byte Program Time (Word/Byte Program command) 16 48 (4) µs Program Suspend Latency Time 1 20 (5) µs Erase Suspend Latency Time 1 25 (5) µs Block Protect Time 18 30 (5) µs 0.75 1.2 (5) s Min Program Write Buffer Blocks Unprotect Time Program/Erase Cycles (per block) Data Retention Note: 1. 2. 3. 4. 5. 100,000 cycles 20 years Typical values measured at room temperature and nominal voltages. Sampled, but not 100% tested. Effective byte programming time 6µs, effective word programming time 12µs. Maximum value measured at worst case conditions for both temperature and VDD after 100,000 program/erase cycles. Maximum value measured at worst case conditions for both temperature and VDD. 25/61 M58LW032C STATUS REGISTER The Status Register provides information on the current or previous Program, Erase, Block Protect or Blocks Unprotect operation. The various bits in the Status Register convey information and errors on the operation. They are output on DQ7-DQ0. To read the Status Register the Read Status Register command can be issued. The Status Register is automatically read after Program, Erase, Block Protect, Blocks Unprotect and Program/Erase Resume commands. The Status Register can be read from any address. The Status Register can only be read using Asynchronous Bus Read or Single Synchronous Read operations. Once the memory returns to Read Memory Array mode the bus will resume the setting in the Configuration Register automatically. The contents of the Status Register can be updated during an Erase or Program operation by toggling the Output Enable pin or by dis-activating (Chip Enable, VIH) and then reactivating (Chip Enable and Output Enable, V IL) the device. Status Register bits SR5, SR4, SR3 and SR1 are associated with various error conditions and can only be reset with the Clear Status Register command. The Status Register bits are summarized in Table 10, Status Register Bits. Refer to Table 10 in conjunction with the following text descriptions. Program/Erase Controller Status Bit (SR7). The Program/Erase Controller Status bit indicates whether the Program/Erase Controller is active or inactive. When the Program/Erase Controller Status bit is Low, VOL, the Program/Erase Controller is active and all other Status Register bits are High Impedance; when the bit is High, V OH, the Program/Erase Controller is inactive. The Program/Erase Controller Status is Low immediately after a Program/Erase Suspend command is issued until the Program/Erase Controller pauses. After the Program/Erase Controller pauses the bit is High. During Program, Erase, Block Protect and Blocks Unprotect operations the Program/Erase Controller Status bit can be polled to find the end of the operation. The other bits in the Status Register should not be tested until the Program/Erase Controller completes the operation and the bit is High. After the Program/Erase Controller completes its operation the Erase Status, Program Status and Block Protection Status bits should be tested for errors. Erase Suspend Status Bit ( SR6). The Erase Suspend Status bit indicates that an Erase operation has been suspended and is waiting to be resumed. The Erase Suspend Status should only be considered valid when the Program/Erase Controller Status bit is High (Program/Erase Controller 26/61 inactive); after a Program/Erase Suspend command is issued the memory may still complete the operation rather than entering the Suspend mode. When the Erase Suspend Status bit is Low, V OL, the Program/Erase Controller is active or has completed its operation; when the bit is High, VOH, a Program/Erase Suspend command has been issued and the memory is waiting for a Program/ Erase Resume command. When a Program/Erase Resume command is issued the Erase Suspend Status bit returns Low. Erase Status Bit (SR5). The Erase Status bit can be used to identify if the memory has failed to verify that the block has erased correctly or that all blocks have been unprotected successfully. The Erase Status bit should be read once the Program/ Erase Controller Status bit is High (Program/Erase Controller inactive). When the Erase Status bit is Low, V OL, the memory has successfully verified that the block has erased correctly or all blocks have been unprotected successfully. When the Erase Status bit is High, VOH, the erase operation has failed. Depending on the cause of the failure other Status Register bits may also be set to High, VOH. ■ If only the Erase Status bit (SR5) is set High, VOH, then the Program/Erase Controller has applied the maximum number of pulses to the block and still failed to verify that the block has erased correctly or that all the blocks have been unprotected successfully. ■ If the failure is due to an erase or blocks unprotect with VPEN low, VOL, then VPEN Status bit (SR3) is also set High, VOH. ■ If the failure is due to an erase on a protected block then Block Protection Status bit (SR1) is also set High, VOH. ■ If the failure is due to a program or erase incorrect command sequence then Program Status bit (SR4) is also set High, VOH. Once set High, the Erase Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new Program or Erase command is issued, otherwise the new command will appear to fail. Program Status Bit (SR4). The Program Status bit is used to identify a Program or Block Protect failure. The Program Status bit should be read once the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). When the Program Status bit is Low, V OL, the memory has successfully verified that the Write Buffer has programmed correctly or the block is protected. When the Program Status bit is High, VOH, the program or block protect operation has M58LW032C failed. Depending on the cause of the failure other Status Register bits may also be set to High, VOH. ■ If only the Program Status bit (SR4) is set High, VOH, then the Program/Erase Controller has applied the maximum number of pulses to the byte and still failed to verify that the Write Buffer has programmed correctly or that the Block is protected. ■ If the failure is due to a program or block protect with VPEN low, VOL, then VPEN Status bit (SR3) is also set High, VOH. ■ If the failure is due to a program on a protected block then Block Protection Status bit (SR1) is also set High, VOH. ■ If the failure is due to a program or erase incorrect command sequence then Erase Status bit (SR5) is also set High, VOH. Once set High, the Program Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new Program or Erase command is issued, otherwise the new command will appear to fail. VPEN Status Bit (SR3). The VPEN Status bit can be used to identify if a Program, Erase, Block Protection or Block Unprotection operation has been attempted when VPEN is Low, VIL. When the VPEN Status bit is Low, VOL, no Program, Erase, Block Protection or Block Unprotection operations have been attempted with VPEN Low, VIL, since the last Clear Status Register command, or hardware reset. When the VPEN Status bit is High, VOH, a Program, Erase, Block Protection or Block Unprotection operation has been attempted with VPEN Low, VIL. Once set High, the VPEN Status bit can only be reset by a Clear Status Register command or a hardware reset. If set High it should be reset before a new Program, Erase, Block Protection or Block Unprotection command is issued, otherwise the new command will appear to fail. Program Suspend Status Bit (SR2). The Program Suspend Status bit indicates that a Program operation has been suspended and is waiting to be resumed. The Program Suspend Status should only be considered valid when the Program/Erase Controller Status bit is High (Program/Erase Controller inactive); after a Program/Erase Suspend command is issued the memory may still complete the operation rather than entering the Suspend mode. When the Program Suspend Status bit is Low, VOL, the Program/Erase Controller is active or has completed its operation; when the bit is High, VOH, a Program/Erase Suspend command has been issued and the memory is waiting for a Program/ Erase Resume command. When a Program/Erase Resume command is issued the Program Suspend Status bit returns Low. Block Protection Status Bit (SR1). The Block Protection Status bit can be used to identify if a Program or Erase operation has tried to modify the contents of a protected block. When the Block Protection Status bit is Low, V OL, no Program or Erase operations have been attempted to protected blocks since the last Clear Status Register command or hardware reset; when the Block Protection Status bit is High, VOH, a Program (Program Status bit SR4 set High) or Erase (Erase Status bit SR5 set High) operation has been attempted on a protected block. Once set High, the Block Protection Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new Program or Erase command is issued, otherwise the new command will appear to fail. Reserved (SR0). SR0 of the Status Register is reserved. Its value should be masked. 27/61 M58LW032C Table 10. Status Register Bits OPERATION SR7 SR6 SR5 SR4 SR3 SR2 SR1 RB Result (Hex) Program/Erase Controller active 0 Hi-Z VOL N/A Write Buffer not ready 0 Hi-Z VOL N/A Write Buffer ready 1 0 0 0 0 0 0 Hi-Z 80h Write Buffer ready in Erase Suspend 1 1 0 0 0 0 0 Hi-Z C0h Program suspended 1 0 0 0 0 1 0 Hi-Z 84h Program suspended in Erase Suspend 1 1 0 0 0 1 0 Hi-Z C4h Program/Block Protect completed successfully 1 0 0 0 0 0 0 Hi-Z 80h Program completed successfully in Erase Suspend 1 1 0 0 0 0 0 Hi-Z C0h Program/Block protect failure due to incorrect command sequence 1 0 1 1 0 0 0 Hi-Z B0h Program failure due to incorrect command sequence in Erase Suspend 1 1 1 1 0 0 0 Hi-Z F0h 1 0 0 1 1 0 0 Hi-Z 98h Program failure due to VPEN error in Erase Suspend 1 1 0 1 1 0 0 Hi-Z D8h Program failure due to Block Protection 1 0 0 1 0 0 1 Hi-Z 92h Program failure due to Block Protection in Erase Suspend 1 1 0 1 0 0 1 Hi-Z D2h Program/Block Protect failure due to cell failure 1 0 0 1 0 0 0 Hi-Z 90h Program failure due to cell failure in Erase Suspend 1 1 0 1 0 0 0 Hi-Z D0h Erase Suspended 1 1 0 0 0 0 0 Hi-Z C0h Erase/Blocks Unprotect completed successfully 1 0 0 0 0 0 0 Hi-Z 80h Erase/Blocks Unprotect failure due to incorrect command sequence 1 0 1 1 0 0 0 Hi-Z B0h Erase/Blocks Unprotect failure due to VPEN error 1 0 1 0 1 0 0 Hi-Z A8h Erase failure due to Block Protection 1 0 1 0 0 0 1 Hi-Z A2h Erase/Blocks Unprotect failure due to failed cells in Block 1 0 1 0 0 0 0 Hi-Z A0h Program/Block Protect failure due to VPEN error 28/61 M58LW032C MAXIMUM RATING Stressing the device above the ratings listed in Table 11, Absolute Maximum Ratings, may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the Operating sections of this specification is not implied. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. Refer also to the STMicroelectronics SURE Program and other relevant quality documents. Table 11. Absolute Maximum Ratings Value Symbol Parameter Unit Min Max TBIAS Temperature Under Bias –40 125 °C TSTG Storage Temperature –55 150 °C Input or Output Voltage –0.6 VDDQ +0.6 V Supply Voltage –0.6 5.0 V VIO VDD, VDDQ 29/61 M58LW032C DC AND AC PARAMETERS This section summarizes the operating and measurement conditions, and the DC and AC characteristics of the device. The parameters in the DC and AC characteristics Tables that follow, are derived from tests performed under the Measure- ment Conditions summarized in Table 12, Operating and AC Measurement Conditions. Designers should check that the operating conditions in their circuit match the measurement conditions when relying on the quoted parameters. Table 12. Operating and AC Measurement Conditions M58LW032C Units 90, 110 Parameter Min Max Supply Voltage (VDD) 2.7 3.6 V Input/Output Supply Voltage (VDDQ) 1.8 VDD V Grade 1 0 70 °C Grade 6 –40 85 °C Ambient Temperature (TA) Load Capacitance (CL) 30 pF Clock Rise and Fall Times 3 ns Input Rise and Fall Times 4 ns Input Pulses Voltages 0 to VDDQ V Input and Output Timing Ref. Voltages 0.5 VDDQ V Figure 9. AC Measurement Input Output Waveform Figure 10. AC Measurement Load Circuit 1.3V 1N914 VDDQ VDD 3.3kΩ VDDQ 0.5 VDDQ DEVICE UNDER TEST 0V DQS CL AI00610 0.1µF 0.1µF CL includes JIG capacitance AI03459 Table 13. Capacitance Symbol CIN COUT Parameter Input Capacitance Output Capacitance Note: 1. TA = 25°C, f = 1 MHz 2. Sampled only, not 100% tested. 30/61 Test Condition Typ Max Unit VIN = 0V 6 8 pF VOUT = 0V 8 12 pF M58LW032C Table 14. DC Characteristics Symbol Parameter Test Condition Min Max Unit ILI Input Leakage Current 0V≤ VIN ≤ VDDQ ±1 µA ILO Output Leakage Current 0V≤ VOUT ≤VDDQ ±5 µA IDD Supply Current (Random Read) E = VIL, G = VIH, fadd = 6MHz 20 mA IDDB Supply Current (Burst Read) E = VIL, G = VIH, fclock = 50MHz 30 mA IDD1 Supply Current (Standby) E = VIH, RP = VIH 40 µA IDD5 Supply Current (Auto Low-Power) E = VIL, RP = VIH 40 µA IDD2 Supply Current (Reset/Power-Down) RP = VIL 40 µA IDD3 Supply Current (Program or Erase, Block Protect, Block Unprotect) Program or Erase operation in progress 30 mA IDD4 Supply Current (Erase/Program Suspend) E = VIH 40 µA VIL Input Low Voltage –0.5 VDDQ x 0.3 V VIH Input High Voltage VDDQ x 0.7 VDDQ + 0.5 V VOL Output Low Voltage IOL = 100µA 0.2 V VOH Output High Voltage IOH = –100µA VLKO VDD Supply Voltage (Erase and Program lockout) VDDQ –0.2 V 2 V 31/61 M58LW032C Figure 11. Asynchronous Bus Read AC Waveforms tAVAV A1-A21 VALID tELQV tELQX tAXQX E L tGLQV tEHQZ tGLQX tEHQX G tAVQV tGHQZ tGHQX DQ0-DQ15 OUTPUT AI06255 Note: Asynchronous Read CR15 = 1 Table 15. Asynchronous Bus Read AC Characteristics. M58LW032C Symbol Parameter Unit 90 110 tAVAV Address Valid to Address Valid Min 90 110 ns tAVQV Address Valid to Output Valid Max 90 110 ns tELQX Chip Enable Low to Output Transition Min 0 0 ns tELQV Chip Enable Low to Output Valid Max 90 110 ns tGLQX Output Enable Low to Output Transition Min 0 0 ns tGLQV Output Enable Low to Output Valid Max 25 25 ns tEHQX Chip Enable High to Output Transition Min 0 0 ns tGHQX Output Enable High to Output Transition Min 0 0 ns tAXQX Address Transition to Output Transition Min 0 0 ns tEHQZ Chip Enable High to Output Hi-Z Max 25 25 ns tGHQZ Output Enable High to Output Hi-Z Max 20 20 ns 32/61 M58LW032C Figure 12. Asynchronous Latch Controlled Bus Read AC Waveforms A1-A21 VALID tAVLH tLHAX tAVLL L tLHLL tLLLH tEHLX tELLH tELLL E tGLQV tEHQZ tGLQX tEHQX G tLLQX tGHQZ tLLQV tGHQX DQ0-DQ15 OUTPUT AI06256b Note: Asynchronous Read CR15 = 1 Table 16. Asynchronous Latch Controlled Bus Read AC Characteristics M58LW032C Symbol Parameter Unit 90 110 tAVLL Address Valid to Latch Enable Low Min 0 0 ns tAVLH Address Valid to Latch Enable High Min 10 10 ns tLHLL Latch Enable High to Latch Enable Low Min 10 10 ns tLLLH Latch Enable Low to Latch Enable High Min 10 10 ns tELLL Chip Enable Low to Latch Enable Low Min 0 0 ns tELLH Chip Enable Low to Latch Enable High Min 10 10 ns tLLQX Latch Enable Low to Output Transition Min 0 0 ns tLLQV Latch Enable Low to Output Valid Min 90 110 ns tLHAX Latch Enable High to Address Transition Min 6 6 ns tGLQX Output Enable Low to Output Transition Min 0 0 ns tGLQV Output Enable Low to Output Valid Max 25 25 ns tEHLX Chip Enable High to Latch Enable Transition Min 0 0 ns Note: For other timings see Table 15, Asynchronous Bus Read Characteristics. 33/61 M58LW032C Figure 13. Asynchronous Page Read AC Waveforms A1-A2 VALID A3-A21 VALID VALID tAVQV tELQV tAXQX tELQX E L tAVQV1 tGLQV tGLQX tEHQZ tAXQX1 tEHQX G tGHQZ tGHQX DQ0-DQ15 OUTPUT OUTPUT AI06257 Note: Asynchronous Read CR15 = 1 Table 17. Asynchronous Page Read AC Characteristics M58LW032C Symbol Parameter Unit 90, 110 tAXQX1 Address Transition to Output Transition Min 6 ns tAVQV1 Address Valid to Output Valid Max 25 ns Note: For other timings see Table 15, Asynchronous Bus Read Characteristics. 34/61 M58LW032C Figure 14. Asynchronous Write AC Waveform, Write Enable Controlled A1-A21 VALID tAVWH tWHAX E L tWHEH tELWL G tWLWH tGHWL tWHGL tWHWL W tDVWH DQ0-DQ15 INPUT tWHDX RB tVPHWH tWHBL VPEN AI06258 Figure 15. Asynchronous Latch Controlled Write AC Waveform, Write Enable Controlled A1-A21 VALID tAVLH L tELLL tLHAX tLLLH tLHGL tWLLH tLHWH E tELWL tWHEH G tGHWL tWLWH tWHWL tWHGL W tDVWH DQ0-DQ15 INPUT tWHDX RB tVPHWH tWHBL VPEN AI06259 35/61 M58LW032C Table 18. Asynchronous Write and Latch Controlled Write AC Characteristics, Write Enable Controlled. M58LW032C Symbol Parameter Unit 90, 110 tAVLH Address Valid to Latch Enable High Min 10 ns tAVWH Address Valid to Write Enable High Min 50 ns tDVWH Data Input Valid to Write Enable High Min 50 ns tELWL Chip Enable Low to Write Enable Low Min 0 ns tELLL Chip Enable Low to Latch Enable Low Min 0 ns tLHAX Latch Enable High to Address Transition Min 6 ns tLHGL Latch Enable High to Output Enable Low Min 95 ns tLHWH Latch Enable High to Write Enable High Min 0 ns tLLLH Latch Enable low to Latch Enable High Min 10 ns tLLWH Latch Enable Low to Write Enable High Min 50 ns Program/Erase Enable High to Write Enable High Min 0 ns tWHAX Write Enable High to Address Transition Min 0 ns tWHBL Write Enable High to Ready/Busy low Max 500 ns tWHDX Write Enable High to Input Transition Min 0 ns tWHEH Write Enable High to Chip Enable High Min 0 ns tGHWL Output Enable High to Write Enable Low Min 20 ns tWHGL Write Enable High to Output Enable Low Min 35 ns tWHWL Write Enable High to Write Enable Low Min 30 ns tWLWH Write Enable Low to Write Enable High Min 70 ns tWLLH Write Enable Low to Latch Enable High Min 10 ns tVPHWH 36/61 M58LW032C Figure 16. Asynchronous Write AC Waveforms, Chip Enable Controlled A1-A21 VALID tAVEH tEHAX W tWLEL tEHWH G tGHEL tELEH tEHEL tEHGL E L tDVEH DQ0-DQ15 INPUT tEHDX RB tVPHEH tEHBL VPEN AI06260 Figure 17. Asynchronous Latch Controlled Write AC Waveforms, Chip Enable Controlled A1-A21 VALID tAVLH tLHAX tAVEH tEHAX L tWLLL tLLLH tLHEH tELLH tLHGL W tWLEL tEHWH G tGHEL tELEH tEHEL tEHGL E tDVEH DQ0-DQ15 INPUT tEHDX RB tVPHEH tEHBL VPEN AI06261 37/61 M58LW032C Table 19. Asynchronous Write and Latch Controlled Write AC Characteristics, Chip Enable Controlled M58LW032C Symbol Parameter Unit 90, 110 tAVLH Address Valid to Latch Enable High Min 10 ns tAVEH Address Valid to Chip Enable High Min 50 ns tDVEH Data Input Valid to Chip Enable High Min 50 ns tEHAX Chip Enable High to Address Transition Min 0 ns tEHBL Chip Enable High to Ready/Busy low Max 500 ns tEHDX Chip Enable High to Input Transition Min 0 ns tEHWH Chip Enable High to Write Enable High Min 0 ns tEHGL Chip Enable High to Output Enable Low Min 35 ns tEHEL Chip Enable High to Chip Enable Low Min 30 ns tELEH Chip Enable Low to Chip Enable High Min 70 ns tELLH Chip Enable Low to Latch Enable High Min 10 ns tGHEL Output Enable High to Chip Enable Low Min 20 ns tLHAX Latch Enable High to Address Transition Min 6 ns tLHGL Latch Enable High to Output Enable Low Min 35 ns tLHEH Latch Enable High to Chip Enable High Min 0 ns tLLLH Latch Enable low to Latch Enable High Min 10 ns tLLEH Latch Enable Low to Chip Enable High Min 50 ns Program/Erase Enable High to Chip Enable High Min 0 ns tWLEL Write Enable Low to Chip Enable Low Min 0 ns tWLLL Write Enable Low to Latch Enable Low Min 0 ns tVPHEH 38/61 DQ0-DQ15 G E L A1-A21 K VALID tAVKH tAVLH tELKH tELLH tLLLH tLLKH tKHLL 0 1 tLHAX tKHAX 2 tQVKH tKHQV tGLKH X-1 Q1 X tKHQX Q2 X+Y Q3 X+2Y tGHQZ tGHQX tEHQZ tEHQX X+2Y+1 X+2Y+2 AI06262 M58LW032C Figure 18. Synchronous Burst Read AC Waveform Note: Valid Clock Edge = Rising (CR6 = 1) 39/61 M58LW032C Figure 19. Synchronous Burst Read - Continuous - Valid Data Ready Output K Output (2) V V V NV NV V V tRLKH R (3) AI05510 Note: 1. Valid Data Ready = Valid Low during valid clock edge (CR8 = 0) 2. V= Valid output, NV= Not Valid output. 3. R is an open drain output with an internal pull up resistor of 1MΩ. Depending on the Valid Data Ready pin capacitance load an external pull up resistor must be chosen according to the system clock period. Table 20. Synchronous Burst Read AC Characteristics M58LW032C Symbol Unit Parameter 90, 110 tAVKH Address Valid to Active Clock Edge Min 7 ns tAVLH Address Valid to Latch Enable High Min 10 ns tELKH Chip Enable Low to Active Clock Edge Min 10 ns tELLH Chip Enable Low to Latch Enable High Min 10 ns tGLKH Output Enable Low to Valid Clock Edge Min 20 ns tKHAX Valid Clock Edge to Address Transition Min 5 ns tKHLL Valid Clock Edge to Latch Enable Low Min 0 ns tKHLH Valid Clock Edge to Latch Enable High Min 0 ns tKHQX Valid Clock Edge to Output Transition Min 3 ns tLLKH Latch Enable Low to Valid Clock Edge Min 6 ns tLLLH Latch Enable Low to Latch Enable High Min 7 ns tKHQV Valid Clock Edge to Output Valid Max 15 ns tQVKH Output Valid to Active Clock Edge Min 5 ns tRLKH Valid Data Ready Low to Valid Clock Edge Min 5 ns Note: For other timings see Table 15, Asynchronous Bus Read Characteristics. 40/61 M58LW032C Figure 20. Reset, Power-Down and Power-up AC Waveform W E, G DQ0-DQ15 tPHQV RB tPLRH RP tVDHPH tPLPH VDD, VDDQ Power-Up and Reset Reset during Program or Erase AI05521 Table 21. Reset, Power-Down and Power-up AC Characteristics M58LW032C Symbol Parameter Unit 90 110 tPHQV Reset/Power-Down High to Data Valid Max 130 150 ns tPLPH Reset/Power-Down Low to Reset/Power-Down High Min 100 100 ns tPLRH Reset/Power-Down Low to Ready High Max 30 30 µs Supply Voltages High to Reset/Power-Down High Min 0 0 µs tVDHPH 41/61 M58LW032C PACKAGE MECHANICAL Figure 21. TSOP56 - 56 lead Plastic Thin Small Outline, 14 x 20 mm, Package Outline A2 1 N e E B N/2 D1 A CP D DIE C A1 TSOP-a α L Note: Drawing is not to scale. Table 22. TSOP56 - 56 lead Plastic Thin Small Outline, 14 x 20 mm, Package Mechanical Data mm inches Symbol Typ Min A Typ Min 1.20 Max 0.0472 A1 0.05 0.15 0.0020 0.0059 A2 0.95 1.05 0.0374 0.0413 B 0.17 0.27 0.0067 0.0106 C 0.10 0.21 0.0039 0.0083 D 19.80 20.20 0.7795 0.7953 D1 18.30 18.50 0.7205 0.7283 E 13.90 14.10 0.5472 0.5551 – – – – L 0.50 0.70 0.0197 0.0276 α 0° 5° 0° 5° N 56 e CP 42/61 Max 0.50 0.0197 56 0.10 0.0039 M58LW032C Figure 22. TBGA64 10x13mm - 8x8 ball array, 1mm pitch, Package Outline D D1 FD FE E SD SE E1 ddd BALL "A1" A e b A2 A1 BGA-Z23 Note: Drawing is not to scale. Table 23. TBGA64 10x13mm - 8x8 ball array, 1mm pitch, Package Mechanical Data millimeters inches Symbol Typ Min A A1 Max Typ Min 1.200 0.300 0.200 A2 0.350 0.0472 0.0118 0.0079 0.850 b 0.400 0.500 Max 0.0138 0.0335 0.0157 0.0197 D 10.000 9.900 10.100 0.3937 0.3898 0.3976 D1 7.000 – – 0.2756 – – ddd 0.100 0.0039 e 1.000 – – 0.0394 – – E 13.000 12.900 13.100 0.5118 0.5079 0.5157 E1 7.000 – – 0.2756 – – FD 1.500 – – 0.0591 – – FE 3.000 – – 0.1181 – – SD 0.500 – – 0.0197 – – SE 0.500 – – 0.0197 – – 43/61 M58LW032C PART NUMBERING Table 24. Ordering Information Scheme Example: M58LW032C 110 N 1 T Device Type M58 Architecture L = Page Mode, Burst Operating Voltage W = VDD = 2.7V to 3.6V; VDDQ = 1.8 to VDD Device Function 032C = 32 Mbit (x16), Uniform Block Speed 90 = 90ns 110 = 110ns Package N = TSOP56: 14 x 20 mm ZA = TBGA64: 10 x 13mm, 1mm pitch Temperature Range 1 = 0 to 70 °C 6 = –40 to 85 °C Option Blank = Standard Packing T = Tape & Reel Packing E = Lead-free Package, Standard Packing F = Lead-free Package, Tape & Reel Packing Note: Devices are shipped from the factory with the memory content bits erased to ’1’. For a list of available options (Speed, Package, etc...) or for further information on any aspect of this device, please contact the ST Sales Office nearest to you. 44/61 M58LW032C APPENDIX A. BLOCK ADDRESS TABLE Table 25. Block Addresses Block Number Address Range (x16 Bus Width) 32 1F0000h-1FFFFFh 31 1E0000h-1EFFFFh 30 1D0000h-1DFFFFh 29 1C0000h-1CFFFFh 28 1B0000h-1BFFFFh 27 1A0000h-1AFFFFh 26 190000h-19FFFFh 25 180000h-18FFFFh 24 170000h-17FFFFh 23 160000h-16FFFFh 22 150000h-15FFFFh 21 140000h-14FFFFh 20 130000h-13FFFFh 19 120000h-12FFFFh 18 110000h-11FFFFh 17 100000h-10FFFFh 16 0F0000h-0FFFFFh 15 0E0000h-0EFFFFh 14 0D0000h-0DFFFFh 13 0C0000h-0CFFFFh 12 0B0000h-0BFFFFh 11 0A0000h-0AFFFFh 10 090000h-09FFFFh 9 080000h-08FFFFh 8 070000h-07FFFFh 7 060000h-06FFFFh 6 050000h-05FFFFh 5 040000h-04FFFFh 4 030000h-03FFFFh 3 020000h-02FFFFh 2 010000h-01FFFFh 1 000000h-00FFFFh 45/61 M58LW032C APPENDIX B. COMMON FLASH INTERFACE - CFI The Common Flash Interface is a JEDEC approved, standardized data structure that can be read from the Flash memory device. It allows a system software to query the device to determine various electrical and timing parameters, density information and functions supported by the memory. The system can interface easily with the de- vice, enabling the software to upgrade itself when necessary. When the CFI Query Command (RCFI) is issued the device enters CFI Query mode and the data structure is read from the memory. Tables 26, 27, 28, 29, 30 and 31 show the addresses used to retrieve the data. Table 26. Query Structure Overview Offset Sub-section Name Description 00h Manufacturer Code 01h Device Code 10h CFI Query Identification String Command set ID and algorithm data offset 1Bh System Interface Information Device timing and voltage information 27h Device Geometry Definition Flash memory layout P(h)(1) Primary Algorithm-specific Extended Query Table Additional information specific to the Primary Algorithm (optional) A(h)(2) Alternate Algorithm-specific Extended Query Table Additional information specific to the Alternate Algorithm (optional) Block Status Register Block-related Information (SBA+02)h Note: 1. Offset 15h defines P which points to the Primary Algorithm Extended Query Address Table. 2. Offset 19h defines A which points to the Alternate Algorithm Extended Query Address Table. 3. SBA is the Start Base Address for each block. Table 27. CFI - Query Address and Data Output Data Address A21-A1 Instruction 10h 51h "Q" 11h 52h "R" 12h 59h "Y" 13h 01h 14h 00h 15h 31h 16h 00h 17h 00h 18h 00h 19h 00h 1Ah(2) 00h Query ASCII String 51h; "Q" 52h; "R" 59h; "Y" Primary Vendor: Command Set and Control Interface ID Code Primary algorithm extended Query Address Table: P(h) Alternate Vendor: Command Set and Control Interface ID Code Alternate Algorithm Extended Query address Table Note: 1. Query Data are always presented on DQ7-DQ0. DQ15-DQ8 are set to ’0’. 2. Offset 19h defines A which points to the Alternate Algorithm Extended Query Address Table. 46/61 M58LW032C Table 28. CFI - Device Voltage and Timing Specification Address A21-A1 Data Description 1Bh 27h (1) VDD Min, 2.7V 1Ch 36h (1) VDD max, 3.6V 1Dh 00h (2) VPP min – Not Available 1Eh 00h (2) VPP max – Not Available 1Fh 04h 2n µs typical time-out for Word, DWord prog – Not Available 20h 08h 2n µs, typical time-out for max buffer write 21h 0Ah 2n ms, typical time-out for Erase Block 22h 00h (3) 23h 04h 2n x typical for Word Dword time-out max – Not Available 24h 04h 2n x typical for buffer write time-out max 25h 04h 2n x typical for individual block erase time-out maximum 26h 00h (3) 2n x typical for chip erase max time-out – Not Available 2n ms, typical time-out for chip erase – Not Available Note: 1. Bits are coded in Binary Code Decimal, bit7 to bit4 are scaled in Volts and bit3 to bit0 in mV. 2. Bit7 to bit4 are coded in Hexadecimal and scaled in Volts while bit3 to bit0 are in Binary Code Decimal and scaled in 100mV. 3. Not supported. Table 29. Device Geometry Definition Address A21-A1 Data Description 27h 16h n where 2n is number of bytes memory Size 28h 01h Device Interface 29h 00h Organization Sync./Async. 2Ah 05h 2Bh 00h 2Ch 01h 2Dh 1Fh 2Eh 00h 2Fh 00h 30h 02h Maximum number of bytes in Write Buffer, 2n Bit7-0 = number of Erase Block Regions in device Number (n-1) of Erase Blocks of identical size; n=64 Erase Block Region Information x 256 bytes per Erase block (128K bytes) 47/61 M58LW032C Table 30. Block Status Register Address A21-A1 Data Selected Block Information 0 Block UnProtected 1 Block Protected 0 Last erase operation ended successfully (2) 1 Last erase operation not ended successfully (2) 0 Reserved for future features bit0 (BA+2)h(1) bit1 bit7-2 Note: 1. BA specifies the block address location, A21-A17. 2. Not Supported. 48/61 M58LW032C Table 31. Extended Query information Address offset Address A21-A2 Data (Hex) x16 Bus Width (P)h 31h 50h "P" (P+1)h 32h 52h "R" (P+2)h 33h 49h "I" (P+3)h 34h 31h Major version number (P+4)h 35h 31h Minor version number (P+5)h 36h CEh (P+6)h 37h 01h (P+7)h 38h 00h (P+8)h 39h 00h Optional Feature: (1=yes, 0=no) bit0, Chip Erase Supported (0=no) bit1, Suspend Erase Supported (1=yes) bit2, Suspend Program Supported (1=yes) bit3, Protect/UnProtect Supported (1=yes) bit4, Queue Erase Supported (0=no) bit5, Instant Individual Block locking (0=no) bit6, Protection bits supported (1=yes) bit7, Page Read supported (1=yes) bit8, Synchronous Read supported (1=yes) bits 9 to 31 reserved for future use (P+9)h 3Ah 01h (P+A)h 3Bh 01h (P+B)h 3Ch 00h (P+C)h 3Dh 33h VDD OPTIMUM Program/Erase voltage conditions (P+D)h 3Eh 00h VPP OPTIMUM Program/Erase voltage conditions (P+E)h 3Fh 01h OTP protection: No. of protection register fields (P+F)h 40h 80h Protection Register’s start address, least significant bits (P+10)h 41h 00h Protection Register’s start address, most significant bits (P+11)h 42h 03h n where 2n is number of factory reprogrammed bytes (P+12)h 43h 03h n where 2n is number user programmable bytes (P+13)h 44h 03h Page Read: 2n Bytes (n = bits 0-7) (P+14)h 45h 03h Synchronous mode configuration fields (P+15)h 46h 01h n where 2n+1 is the number of Words for the burst Length = 4 (P+16)h 47h 02h n where 2n+1 is the number of Words for the burst Length = 8 (P+17)h 48h 07h Burst Continuous Description Query ASCII string - Extended Table Function allowed after Suspend: Program allowed after Erase Suspend (1=yes) Bit 7-1 reserved for future use Block Status Register bit0, Block Protect Bit status active (1=yes) bit1, Block Lock-Down Bit status active (not available) bits 2 to 15 reserved for future use Note: 1. Bit7 to bit4 are coded in Hexadecimal and scaled in Volt while bit3 to bit0 are in Binary Code Decimal and scaled in mV. 49/61 M58LW032C APPENDIX C. FLOW CHARTS Figure 23. Write to Buffer and Program Flowchart and Pseudo Code Start Write to Buffer E8h Command, Block Address Read Status Register NO SR7 = 1 NO Write to Buffer Timeout YES YES Note 1: N+1 is number of Words to be programmed Write N(1), Block Address Try Again Later Write Buffer Data, Start Address X=0 X=N YES NO Note 2: Next Program Address must have same A5-A21. Write Next Buffer Data, Next Program Address(2) X=X+1 Program Buffer to Flash Confirm D0h Read Status Register SR7 = 1 NO YES Note 3: A full Status Register Check must be done to check the program operation's success. Full Status Register Check(3) End AI06263b 50/61 M58LW032C Figure 24. Program Suspend & Resume Flowchart and Pseudo Code Start Write B0h Program/Erase Suspend Command: – write B0h – write 70h Write 70h do: – read status register Read Status Register SR7 = 1 NO while SR7 = 1 YES SR2 = 1 NO Program Complete If SR2 = 0, Program completed YES Read Memory Array command: – write FFh – one or more data reads from other blocks Write FFh Read data from another block Write D0h Write FFh Program Continues Read Data Program Erase Resume Command: – write D0h to resume erasure – if the program operation completed then this is not necessary. The device returns to Read Array as normal (as if the Program/Erase Suspend command was not issued). AI00612b 51/61 M58LW032C Figure 25. Erase Flowchart and Pseudo Code Start Erase command: – write 20h – write D0h to Block Address (A12-A17) (memory enters read Status Register after the Erase command) Write 20h Write D0h to Block Address NO Read Status Register Suspend SR7 = 1 YES NO Suspend Loop do: – read status register – if Program/Erase Suspend command given execute suspend erase loop while SR7 = 1 YES SR3 = 0 NO VPEN Invalid Error (1) NO Command Sequence Error NO Erase Error (1) NO Erase to Protected Block Error If SR3 = 1, VPEN invalid error: – error handler YES SR4, SR5 = 0 If SR4, SR5 = 1, Command Sequence error: – error handler YES SR5 = 0 If SR5 = 1, Erase error: – error handler YES SR1 = 0 If SR1 = 1, Erase to Protected Block Error: – error handler YES End AI00613C Note: 1. If an error is found, the Status Register must be cleared (Clear Status Register Command) before further Program or Erase operations. 52/61 M58LW032C Figure 26. Erase Suspend & Resume Flowchart and Pseudo Code Start Write B0h Program/Erase Suspend Command: – write B0h – write 70h Write 70h do: – read status register Read Status Register SR7 = 1 NO while SR7 = 1 YES SR6 = 1 NO Erase Complete If SR6 = 0, Erase completed YES Read Memory Array command: – write FFh – one or more data reads from other blocks Write FFh Read data from another block or Program Write D0h Write FFh Erase Continues Read Data Program/Erase Resume command: – write D0h to resume the Erase operation – if the Program operation completed then this is not necessary. The device returns to Read mode as normal (as if the Program/Erase suspend was not issued). AI00615b 53/61 M58LW032C Figure 27. Block Protect Flowchart and Pseudo Code Start Write 60h Block Address Block Protect Command – write 60h, Block Adress – write 01h, Block Adress Write 01h Block Address do: – read status register Read Status Register SR7 = 1 NO while SR7 = 1 YES SR3 = 1 YES VPEN Invalid Error If SR3 = 1, VPEN Invalid Error YES Invalid Command Sequence Error If SR4 = 1, SR5 = 1 Invalid Command Sequence Error YES Block Protect Error NO SR4, SR5 = 1,1 NO SR4 = 1 If SR4 = 1, Block Protect Error NO Write FFh Read Memory Array Command: – write FFh Block Protect Sucessful AI06157b 54/61 M58LW032C Figure 28. Blocks Unprotect Flowchart and Pseudo Code Start Write 60h Blocks Unprotect Command – write 60h, Block Adress – write D0h, Block Adress Write D0h do: – read status register Read Status Register SR7 = 1 NO while SR7 = 1 YES SR3 = 1 YES VPEN Invalid Error If SR3 = 1, VPEN Invalid Error YES Invalid Command Sequence Error If SR4 = 1, SR5 = 1 Invalid Command Sequence Error YES Blocks Unprotect Error NO SR4, SR5 = 1,1 NO SR5 = 1 If SR5 = 1, Blocks Unprotect Error NO Write FFh Read Memory Array Command: – write FFh Blocks Unprotect Sucessful AI06158b 55/61 M58LW032C Figure 29. Protection Register Program Flowchart and Pseudo Code Start Write C0h Protection Register Program Command – write C0h – write Protection Register Address, Protection Register Data Write PR Address, PR Data do: – read status register Read Status Register SR7 = 1 NO while SR7 = 1 YES YES SR3, SR4 = 1,1 VPEN Invalid Error If SR3 = 1, SR4 = 1 VPEN Invalid Error NO YES Protection Register Program Error If SR1 = 0, SR4 = 1 Protection Register Program Error YES Protection Register Program Error If SR1 = 1, SR4 = 1 Program Error due to Protection Register Protection SR1, SR4 = 0,1 NO SR1, SR4 = 1,1 NO Write FFh Read Memory Array Command: – write FFh PR Program Sucessful AI06159b Note: PR = Protection Register 56/61 M58LW032C Figure 30. Command Interface and Program Erase Controller Flowchart (a) WAIT FOR COMMAND WRITE 90h NO YES READ SIGNATURE 98h NO YES CFI QUERY 70h NO YES READ STATUS READ ARRAY NO 50h YES CLEAR STATUS E8h NO YES PROGRAM BUFFER LOAD 20h(1) NO YES ERASE SET-UP NO PROGRAM COMMAND ERROR FFh D0h YES NO YES D0h NO YES C A ERASE COMMAND ERROR B Note 1. The Erase command (20h) can only be issued if the flash is not already in Erase Suspend. AI03618 57/61 M58LW032C Figure 31. Command Interface and Program Erase Controller Flowchart (b) A B ERASE READ STATUS YES (READ STATUS) Program/Erase Controller READY Status bit in the Status Register ? NO READ ARRAY B0h YES NO YES FFh READ STATUS NO ERASE SUSPEND NO YES ERASE SUSPENDED READY ? NO READ STATUS YES WAIT FOR COMMAND WRITE READ STATUS YES 70h NO READ SIGNATURE YES 90h NO CFI QUERY YES 98h NO PROGRAM BUFFER LOAD YES E8h NO PROGRAM COMMAND ERROR NO D0h YES c D0h YES READ STATUS (ERASE RESUME) NO READ ARRAY AI03619 58/61 M58LW032C Figure 32. Command Interface and Program Erase Controller Flowchart (c). B C PROGRAM READ STATUS YES READY ? (READ STATUS) Program/Erase Controller Status bit in the Status Register NO READ ARRAY B0h NO YES YES NO READ STATUS FFh PROGRAM SUSPEND NO YES PROGRAM SUSPENDED READY ? NO YES WAIT FOR COMMAND WRITE READ STATUS YES READ STATUS 70h NO READ SIGNATURE YES 90h NO CFI QUERY YES 98h NO READ ARRAY NO D0h YES READ STATUS (PROGRAM RESUME) AI00618 59/61 M58LW032C REVISION HISTORY Table 32. Document Revision History Date Version Revision Details 11-Mar-2002 -01 First Issue (Data Brief) 10-Jul-2002 -02 Document expanded to full Product Preview 06-Aug-2002 2.1 Revision numbering modified: a minor revision will be indicated by incrementing the digit after the dot, and a major revision, by incrementing the digit before the dot (revision version 02 equals 2.0). Word Effective Programming Time modified. Program Write Buffer and Block Erase Time parameters modified in Table 9. Speed Class 90ns added. VDD, VDDQ, VSS and VSSQ signal descriptions modified. 02-Sep-2002 2.2 Figure 12, Asynchronous Latch Controlled Bus Read AC Waveforms, modified. 2.3 REVISION HISTORY moved to after the appendices. Table 9, Program, Erase Times and Program Erase Endurance Cycles table modified. All DU connections changed to NC in Table 4, TBGA64 Connections (Top view through package). VIL max and VIH min modified in Table 14, DC Characteristics. Block Protect setup command address modified in Table 5, Commands. Data and Descriptions clarified in CFI Table 31, Extended Query information. 3.0 Document promoted to full datasheet. Summary Description clarified, Bus Operations clarified, Smart Protection added, Read Modes section added, Status Register and Configuration Register bit nomenclature modified, VPEN Invalid Error clarified in Flowcharts. Lead-free packing options added to Ordering Information Scheme. 16-Dec-2002 29-Apr-2003 60/61 M58LW032C Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics. The ST logo is registered trademark of STMicroelectronics All other names are the property of their respective owners © 2003 STMicroelectronics - All Rights Reserved STMicroelectronics GROUP OF COMPANIES Australia - Brazil - Canada - China - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan - Malaysia - Malta Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States www.st.com 61/61