MAXIM MAX6613

19-2477; Rev 3; 12/10
Low-Voltage Analog Temperature
Sensor in an SC70 Package
The MAX6613 is a low-power precision analog output
temperature sensor in a tiny 5-pin SC70 package. The
MAX6613 operates over a 1.8V to 5.5V supply voltage
range, with a typical current consumption of only 7.5µA.
It is particularly well suited for portable applications
where minimizing battery cost and maximizing useful
battery life are crucial.
The MAX6613 provides an analog voltage output proportional to temperature. Accuracy is ±4.0°C (max)
over a range of TA = 0°C to +50°C and ±4.4°C (max)
from TA = -20°C to +80°C. Self-heating effects are negligible due to the low current consumption of the part.
Unlike many analog temperature sensors, the MAX6613
is stable with any capacitive load from 0pF to 1000pF,
providing broad flexibility in board-level design.
The operating temperature range varies with the voltage supply. The MAX6613 can be used over a -55°C to
+130°C range with a 2.5V to 5.5V supply voltage. For
applications with a supply voltage of 1.8V, the
MAX6613 can be used over a +25°C to +130°C temperature range.
Applications
Cellular Phones
Disk Drives
GPS Equipment
Printers
Medical Instruments
Fax Machines
Battery Management
HVAC
Features
♦ 1.8V to 5.5V Supply Voltage
♦ 4.0°C Accuracy
♦ Low Supply Consumption, 7.5µA (typ)
♦ -55°C to +130°C Temperature Range
♦ SC70 Package
♦ Pin Compatible to LM20
Ordering Information
PART
PINPACKAGE
TEMP RANGE
MAX6613MXK+T
TOP
MARK
-55°C to +130°C
5 SC70-5
ADJ
MAX6613MXK/V+T -55°C to +130°C
5 SC70-5
ADJ
+Denotes a lead(Pb)-free/RoHS-compliant package.
/V denotes an automotive qualified part.
Appliances
Typical Application Circuit
VCC
Pin Configuration
TOP VIEW
VCC
N.C.
VOUT
0.1μF
+
MICROCONTROLLER
VCC
1
GND 2
MAX6613
GND
GND
5
GND
4
VCC
ADC IN
MAX6613
100pF
GND
OUT 3
SC70
________________________________________________________________ Maxim Integrated Products
For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642,
or visit Maxim’s website at www.maxim-ic.com.
1
MAX6613
General Description
MAX6613
Low-Voltage Analog Temperature
Sensor in an SC70 Package
ABSOLUTE MAXIMUM RATINGS
(All voltages referenced to GND, unless otherwise noted.)
VCC to GND ..............................................................-0.3V to +6V
All Other Pins to GND.................................-0.3V to (VCC + 0.3V)
OUT Short to GND......................................................Continuous
Output Current ....................................................-1mA to +50mA
ESD Protection (Human Body Model)................................2000V
Continuous Power Dissipation (TA = +70°C)
5-Pin SC70 (derate 3.1mW/°C above +70°C) ...........246.9mW
Operating Temperature Range .........................-55°C to +130°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering 10s) ..................................+300°C
Soldering Temperature (reflow) .......................................+260°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
DC ELECTRICAL CHARACTERISTICS
(VCC = 1.8V to 5.5V, TA = -55°C to +130°C. Typical values are at TA = +25°C, unless otherwise noted.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
VCC = 2.7V, TA = 0°C to +50°C
Temperature-to-Voltage Error
(Notes 2, 3)
-4
+4
+4.4
VCC = 2.7V, TA = -55°C to +100°C
-4.5
+4.5
VCC = 2.7V, TA = +100°C to +125°C
-4.7
+4.7
VCC = 2.7V, TA = +125°C to +130°C
-5
Nonlinearity
TA = -55°C to +100°C
Sensor Gain (Temperature
Sensitivity or Average Slope)
TA = -20°C to +100°C (Note 3)
Supply Sensitivity (Note 3)
-10.98
IQ
±0.4
%
-11.23
-11.47
300
0 < IL < 16µA, TA = -55°C to +125°C
-2.5
0 < IL < 16µA, TA = 125°C to 130°C
-4.8
mV/°C
Ω
mV
TA = -20°C to +130°C, VCC ≤ 5.5V
1
3.3
TA = -55°C to -20°C, VCC ≤ 4.5V
1
4.7
mV/V
13
µA
1000
pF
1
No load
Long-Term Stability
TA = room temperature for 1000hr (Note 4)
Temperature Coefficient of
Supply Current
2
V
160
No sustained oscillations for capacitive
loads in this range (Note 4)
Note 1:
Note 2:
Note 3:
Note 4:
°C
+5
0 < IL < 16µA, TA = -55°C to +125°C
Capacitive Load
Power-Down Supply Current
UNITS
1.8455
0 < IL < 16µA, TA = +125°C to +130°C
TA = -55°C to -20°C, VCC ≤ 5.5V
Quiescent Current
MAX
-4.4
TA = 0°C
Load Regulation
TYP
VCC = 2.7V, TA = -20°C to +85°C
Output Voltage
Maximum Output Impedance
MIN
VCC < 0.8V
7.5
0
0.1
°C
15
nA/°C
0.1
µA
All parameters tested at room temperature. Values through temperature limits are guaranteed by design.
VOUT = -0.0000022 ✕ T2 - 0.01105 ✕ T + 1.8455 (T = temperature in degrees Celsius).
Guaranteed by design to 3 sigma.
Guaranteed by design.
_______________________________________________________________________________________
Low-Voltage Analog Temperature
Sensor in an SC70 Package
OUTPUT VOLTAGE vs. SUPPLY VOLTAGE
MAX6613 toc03
MAX6613 toc02
8
7
6
5
4
3
1
0
0
1.0
2.0
3.0
4.0
5.0
6.0
0
1.0
SUPPLY VOLTAGE (V)
SUPPLY CURRENT vs. TEMPERATURE
2.0
3.0
4.0
5.0
6.0
SUPPLY VOLTAGE (V)
STEP RESPONSE FROM +25°C TO +125°C
MAX6613 toc05
MAX6613 toc04
10.0
9.5
9.0
8.0
9
2
TEMPERATURE (°C)
8.5
SUPPLY CURRENT vs. SUPPLY VOLTAGE
10
SUPPLY CURRENT (μA)
OUTPUT VOLTAGE (V)
MAX6613 toc01
1.510
1.508
1.506
1.504
1.502
1.500
1.498
1.496
1.494
1.492
1.490
1.488
1.486
1.484
1.482
1.480
-40 -25 -10 5 20 35 50 65 80 95 110 125
SUPPLY CURRENT (μA)
OUTPUT VOLTAGE (V)
OUTPUT VOLTAGE vs. TEMPERATURE
2.3
2.2
2.1
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
1.55V
VOUT
VCC = 3.3V
VCC = 5V
200mV/div
7.5
VCC = 2.7V
7.0
6.5
6.0
430mV
5.5
5.0
-40 -25 -10 5 20 35 50 65 80 95 110 125
1s/div
TEMPERATURE (°C)
Pin Description
PIN
NAME
FUNCTION
1
N.C.
No Connection. Must be connected to ground or left unconnected.
2
GND
Ground. Should be connected to pin 5. May be left unconnected, if desired.
3
OUT
Voltage Output
4
VCC
Supply Voltage. Bypass to GND with a 0.1μF capacitor.
5
GND
Ground
_______________________________________________________________________________________
3
MAX6613
Typical Operating Characteristics
(RL = ∞Ω, TA = +30°C, unless otherwise noted.)
MAX6613
Low-Voltage Analog Temperature
Sensor in an SC70 Package
Table 1. Linear and Quadratic Output Equation
PARAMETER
SYMBOL
Temperature Error
Based on:
OUT = 1.8639 - 0.0115 x Temp
(Note 4)
Temperature Error
Based on:
OUT = 1.8639 - 0.0115 x Temp 0.00000388 x Temp2 (Note 4)
CONDITIONS
MIN
TYP
VCC = 2.7V, TA = -55°C
0.6
7.9
VCC = 2.7V, TA = -20°C
-0.4
+5.8
VCC = 2.7V, TA = 0°C
-0.9
+4.5
VCC = 2.7V, TA = +50°C
-2.6
+3.0
VCC = 2.7V, TA = +85°C
-3.6
+3.5
VCC = 2.7V, TA = +100°C
-4.0
+3.7
VCC = 2.7V, TA = +125°C
-4.8
+4.2
VCC = 2.7V, TA = +130°C
-5.1
+4.2
VCC = 2.7V, TA = -55°C
-0.4
+6.9
VCC = 2.7V, TA = -20°C
-0.6
+5.7
VCC = 2.7V, TA = 0°C
-0.9
+4.5
VCC = 2.7V, TA = +50°C
-3.5
+2.1
VCC = 2.7V, TA = +85°C
-6.1
+1.0
VCC = 2.7V, TA = +100°C
-7.4
+0.4
VCC = 2.7V, TA = +125°C
-10.1
-1.0
VCC = 2.7V, TA = +130°C
-10.8
-1.5
Detailed Description
The MAX6613 analog output temperature sensor’s output voltage is a discrete function of its die temperature.
The maximum supply current is 13µA, and the supply
voltage range is from 2.5V to 5.5V for the -55°C to
+130°C temperature range, or 1.8V to 5.5V for the
+25°C to +130°C temperature range.
Transfer Function
The temperature-to-voltage transfer function is approximately linear and can be described by the quadratic
equation:
UNITS
°C
°C
where T is the die temperature of the MAX6613 in °C.
Therefore:
T = (1.8455 - VOUT) / 0.01123V
Compatibility with Other Temperature
Sensors
The MAX6613 can be used to replace temperature sensors using other output algorithms. Table 1 provides
information for a linear and quadratic output equation.
Contact the factory for performance information about
another equation.
VOUT = -0.0000022 ✕ T2 - 0.01105 ✕ T + 1.8455V
In many cases, a linear approximation can be applied:
VOUT = -0.01123 ✕ T + 1.8455V
4
MAX
_______________________________________________________________________________________
Low-Voltage Analog Temperature
Sensor in an SC70 Package
Sensing Circuit Board and
Ambient Temperature
A temperature sensor IC like the MAX6613 that senses
its own die temperature must be mounted on, or close
to, the object whose temperature it is intended to measure. Because there is a good thermal path between
the package’s metal lead and the IC die, the MAX6613
can accurately measure the temperature of the circuit
board to which it is soldered. If the sensor is intended
to measure the temperature of a heat-generating component on the circuit board, it should be mounted as
close as possible to that component and should share
supply and ground traces (if they are not noisy) with
that component where possible. This optimizes the
thermal connection from the component to the sensor.
The thermal path between the plastic package and the
die is not as good as the path through the lead, so the
MAX6613, like all temperature sensors in plastic packages, is less sensitive to the temperature of the surrounding air than to the temperature of its leads. It can
be successfully used to sense ambient temperature if
the circuit board is designed to track the ambient temperature.
As with any IC, the wiring and circuits must be kept
insulated and dry to avoid leakage and corrosion,
especially if the part is operated at cold temperatures
where condensation can occur.
The change in die temperature introduced by the part
due to self-heating is negligible.
Chip Information
PROCESS: BiCMOS
Package Information
For the latest package outline information and land patterns,
go to www.maxim-ic.com/packages. Note that a “+”, “#”, or
“-” in the package code indicates RoHS status only. Package
drawings may show a different suffix character, but the drawing
pertains to the package regardless of RoHS status.
PACKAGE
TYPE
PACKAGE
CODE
OUTLINE
NO.
LAND
PATTERN NO.
5 SC70
X5+1
21-0076
90-0188
_______________________________________________________________________________________
5
MAX6613
Applications Information
MAX6613
Low-Voltage Analog Temperature
Sensor in an SC70 Package
Revision History
REVISION
NUMBER
REVISION
DATE
0
5/02
1
11/03
2
1/06
3
12/10
DESCRIPTION
PAGES
CHANGED
Initial release
—
Fix error in equation
4
Update spec in table
2
Add lead-free and automotive part, style edits
1, 2, 3, 5, 6
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
6 _____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600
© 2010 Maxim Integrated Products
Maxim is a registered trademark of Maxim Integrated Products, Inc.