JDSU MDX-01AD1042B

COMMUNICATIONS MODULES & SUBSYSTEMS
TM
WaveReady
100 GHz Dense Wavelength Division Multiplexing
Optical Add/Drop Module
Key Features
• MUX/DEMUX of one, four, or eight ITU 100 GHz spaced
channels onto a fiber pair
• Add/drop up to eight channels at remote sites
• Upgradeable to 32 channels per fiber
• Low pass-through insertion loss for C-band channels
• Fits into standard LGX™-mounting solutions
• Thermally stable passive optics require no power
Applications
• Improves capacity exhaust in
fiber-constrained situations
• Conserves or reclaims fiber with
DWDM
• Supports point-to-point
multichannel
• Supports linear (bus) add/drop and
hub-and-spoke ring architectures
Compliances
• Telcordia GR-1221
• RoHS compliant (exemptions 7b,
8a)
NORTH AMERICA : 800 498-JDSU (5378)
The JDSU WaveReady 100 GHz Optical Add/Drop Modules (OADM) comprise a
family of flexible, low-cost solutions to enable capacity expansion of existing fiber.
Through use of dense wavelength division multiplexing (DWDM) technology, a
single optical fiber can carry up to 32 discrete optical channels.
The 100 GHz DWDM OADM is configurable as both an OADM and a terminal
multiplexer and demultiplexer (MUX/DEMUX) to support a broad range of
architectures ranging from scalable point-to-point links to four-fiber protected
rings. Innovative band upgrade ports allow for in-service pay-as-you-grow
capacity scaling in multiples of one, four, or eight channels, allowing for lowest
first-day cost without limiting growth. Market standard LGX packaging is readily
deployed in existing LGX-compatible frames or can be adapted into the
WaveReady line of shelves.
The 100 GHz OADM is designed to operate with both the WaveReady line of
transponder and optical regenerator solutions and ITU transponder cards of
widely available transmission equipment.
WORLDWIDE : +800 5378-JDSU
WEBSITE : www.jdsu.com/test
100 GHZ DWDM OADM
2
Functional Diagrams
1-Channel DWDM OADM
East Input
4-Channel DWDM OADM
8-Channel DWDM OADM
Channel 1 Drop
Upgrade (Thru) Output
Line Input
Line Input
East Output
Channels 1-8 Drop
Channels 1-4 Drop
Channel 1 Add
Upgrade (Thru) Input
Upgrade (Thru) Output
Upgrade (Thru) Output
Upgrade (Thru) Input
West Input
Upgrade (Thru) Input
Channel 1 Drop
Line Output
Upgrade (Thru) Output
West Output
Line Output
Channels 1-4 Add
Channel 1 Add
Channels 1-8 Add
Upgrade (Thru) Input
Sample Configurations
Point-to-Point DWDM
OADM4
OADM4
OADM4
OADM4
OADM4
OADM4
Upgrade
Upgrade
Protected Linear (Bus) Network
HEADEND 1
HEADEND 2
RT1
RT2
OADM4
OADM8
OADM8
OADM1
OADM4
OADM4
OADM4
Upgrade
Upgrade
Protected Ring (Hub and Spoke)
HUB
RT1
OADM8
OADM8
Upgrade
Upgrade
RT4
OADM1
OADM4
RT3
OADM1
OADM4
RT2
OADM1
100 GHZ DWDM OADM
3
Specifications1
Parameter
Network Optical
Mux/add insertion loss
Demux/drop insertion loss
Upgrade path insertion loss
Optical pass-through insertion loss
Channel passband
Channel flatness
Channel loss uniformity
Isolation
Adjacent ITU 100 GHz channel
Non-adjacent ITU 100 GHz channel
Through channel add/drop
Optical return loss
Maximum input optical power
– Sum of all ports
Polarization dependent loss (PDL)
Polarization mode dispersion (PMD)
Physical
Size (H x W x L)
Optical connector type, all ports
Weight, approximate
Environmental
Operating ambient temperature
Storage temperature
Relative humidity, non-condensing
1-Channel2
4-Channel
8-Channel
Maximum
Typical
Maximum
Typical
Maximum
Maximum
Minimum
Minimum
1.4 dB
1.0 dB
1.4 dB
1.0 dB
0.9 dB
1.8 dB
±0.1 nm
0.5 dB
—
3.7 dB
2.6 dB
3.7 dB
2.6 dB
0.9 dB
1.8 dB
±0.1 nm
0.5 dB
1 dB
4.0 dB
3.2 dB
4.0 dB
3.2 dB
1.2 dB
2.4 dB
±0.1 nm
0.5 dB
1 dB
Minimum
Minimum
Minimum
Minimum
25 dB
50 dB
30 dB
40 dB
1W
25 dB
50 dB
30 dB
40 dB
1W
25 dB
50 dB
30 dB
40 dB
1W
Maximum
Maximum
0.2 dB
0.2 ps
0.2 dB
0.2 ps
0.2 dB
0.2 ps
129.5 x 28.4 x 160.3 mm
(5.10 x 1.12 x 6.31 in)
single-slot LGX
Duplex LC/PC
0.45 kg (1 lb)
129.5 x 28.4 x 160.3 mm
(5.10 x 1.12 x 6.31 in)
single-slot LGX
Duplex LC/PC
0.45 kg (1 lb)
129.5 x 57.7 x 160.3 mm
(5.10 x 2.27 x 6.31 in)
double-slot LGX
Duplex LC/PC
0.91 kg (2 lb)
–5 to 70°C
–40 to 85°C
5 to 85%
1. All specifications are guaranteed over the life, operating temperatures, and wavelength range specified.
2 One-channel DWDM OADM provides add/drop functionality for two fiber pairs. Optical specifications for east and west interfaces are identical.
100 GHZ DWDM OADM
Ordering Information
For more information on this or other products and their availability, please contact your local JDSU account manager or
JDSU directly at 1-800-498-JDSU (5378) in North America, +1 800-5378-JDSU worldwide or via e-mail at [email protected].
Sample: MDX-04MD1001B
MDX-
10
Code
01AD
04MD
08MD
Channels
1
2
3
Channel Plan
Codes
61 —
—
60 01 0A
59 01 0A
58 01 0A
57 01 0A
56 —
—
55 02 0A
54 02 0A
53 02 0A
52 02 0A
51 —
—
50 03
0B
49 03
0B
48 03
0B
47 03
0B
46 —
—
45 04
0B
44 04
0B
43 04
0B
42 04
0B
41 —
—
40 —
—
39 —
—
38 05
0C
37 05
0C
36 05
0C
35 05
0C
34 —
—
33 06
0C
32 06
0C
31 06
0C
30 06
0C
29 —
—
28 07 0D
27 07 0D
26 07 0D
25 07 0D
24 —
—
23 08 0D
22 08 0D
21 08 0D
20 08 0D
19 —
—
18 —
—
B
ITU Number
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
Frequency (THz)
196.10
196.00
195.90
195.80
195.70
195.60
195.50
195.40
195.30
195.20
195.10
195.00
194.90
194.80
194.70
194.60
194.50
194.40
194.30
194.20
194.10
194.00
193.90
193.80
193.70
193.60
193.50
193.40
193.30
193.20
193.10
193.00
192.90
192.80
192.70
192.60
192.50
192.40
192.30
192.20
192.10
192.00
191.90
191.80
Wavelength (nm)
1528.77
1529.55
1530.33
1531.12
1531.9
1532.68
1533.47
1534.25
1535.04
1535.82
1536.61
1537.4
1538.19
1538.98
1539.77
1540.56
1541.35
1542.14
1542.94
1543.73
1544.53
1545.32
1546.12
1546.92
1547.72
1548.51
1549.32
1550.12
1550.92
1551.72
1552.52
1553.33
1554.13
1554.94
1555.75
1556.55
1557.36
1558.17
1558.98
1559.79
1560.61
1561.42
1562.23
1563.05
Note: Contact your JDSU representative for required ITU wavelengths in the range of 1563.86 to 1527.99 nm.
LATIN AMERICA
NORTH AMERICA : 800 498-JDSUTEL
(5378)
: +55 11 5503 3800
FAX : +55 11 5505 1598
ASIA PACIFIC
WORLDWIDE
: +800
5378-JDSU
TEL : +852
2892
0990
FAX : +852 2892 0770
Product specifications and descriptions in this document subject to change without notice. © 2008 JDS Uniphase Corporation
WEBSITE : www.jdsu.com
EMEA
WEBSITE : www.jdsu.com/test
TEL : +49 7121 86 2222
FAX : +49 7121 86 1222
September 2008
10143156 002 0908 DWDMOADM.DS.CMS.TM.AE