MURATA MEV1S1209SC

MEV Series
3kVDC Isolated 1W Single Output DC/DC Converters
Wide temperature performance at full
1 Watt load, –40°C to 85°C
No heatsink required
Parameter
Industry standard pinout
Voltage range
Reflected ripple current
5V & 12V input
Fully encapsulated with toroidal
magnetics
No external components required
No electrolytic or tantalum capacitors
PRODUCT OVERVIEW
The MEV series is the new high performance
version of our 1W NMV series. The MEV series
is more efficient and offers improved regulation
performance ≤5% for applications where a wide
output voltage variation can not be tolerated. They
are ideally suited for providing local supplies on
control system boards with the added benefit
of 3kVDC galvanic isolation to reduce switching
noise. The MEV series is currently available in an
industry SIP 7 package.
30
20
20
15
15
15
15
15
%
%
pF
kHrs
80.5
82.5
84
84.5
80
83
84
82
84
86
87
87
83.5
86
87
87
38
42
40
39
28
50
70
59
3583
3286
2886
2419
3308
3054
2705
2290
MTTF2
Isolation
Capacitance
mVp-p
Efficiency (Min.)
20
12
10
8
12
8
7
7
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external
capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the
additional external capacitance for reliable start up.
INPUT CHARACTERISTICS
5V, 9V, 12V, & 15V output
6
5
5.5
5
4.8
3.2
3.1
2.8
%
5.2
4
4.5
4.2
4.4
2.9
2.9
2.4
Ripple & Noise
(Max)1
233
227
226
225
98
96
94
94
Load Regulation
(Typ)
mA
200
111
84
67
200
111
84
67
UL 94V-0 package material
3kVDC isolation (1 minute)
Input Current at
Rated Load
mA
5
9
12
15
5
9
12
15
Efficiency (Typ.)
Power density 0.85W/cm3
V
5
5
5
5
12
12
12
12
Ripple & Noise
(Typ)1
Efficiency from 80%
V
MEV1S0505SC
MEV1S0509SC
MEV1S0512SC
MEV1S0515SC
MEV1S1205SC
MEV1S1209SC
MEV1S1212SC
MEV1S1215SC
Load Regulation
(Max)
RoHS compliant
Output
Voltage
FEATURES
Nominal Input
Voltage
Order Code
Output Current
SELECTION GUIDE
Conditions
Min.
Typ.
Max.
Continuous operation, 5V input types
Continuous operation, 12V input types
5V input types
12V input types
4.5
10.8
5
12
11
5
5.5
13.2
20
15
Units
Typ.
Max.
Units
1
W
1.05
1.2
%/%
Typ.
Max.
Units
V
mA p-p
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, MEV05 types
Input voltage VIN, MEV12 types
300°C
300mW
7V
15V
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated Power
Voltage Set Point Accuracy
Line regulation
TA=-40°C to 85°C
See tolerance envelope
High VIN to low VIN
Min.
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation test voltage
Resistance
Flash tested for 1 minute
Viso= 1000VDC
3000
10
VDC
GΩ
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching frequency
5V input types
12V input types
Min.
Typ.
Max.
60
75
Units
kHz
TEMPERATURE CHARACTERISTICS
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Parameter
Conditions
Min.
Specification
Storage
All output types
-40
-50
Case Temperature above
ambient
Cooling
5V output types
All other output types
Free air convection
Typ.
Max.
Units
85
125
20
20
°C
1. See Ripple & Noise characterisation method.
2. Calculated using MIL-HDBK-217F FN2 with nominal input voltage at full load.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KDC_MEVC.A01 Page 1 of 4
MEV Series
3kVDC Isolated 1W Single Output DC/DC Converters
TEMPERATURE DERATING GRAPH
TOLERANCE ENVELOPE
5%
85°C
1.0
0.5
0
-40
Output Voltage
Output Power (W)
1.5
Safe Operating Area
100
50
0
Ambient Temperature (°C)
150
2%
Typic
a
l Loa
VNOM
10
25
d Lin
50
e
0%
-4%
100
75
Output Load Current (%)
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MEV series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 3kVDC for 1 minute.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specific agency approvals, such as the MEV series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The MEV series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
RoHS COMPLIANT INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of
300°C for 10 seconds. The pin termination finish on the SIP package type is Tin Plate, Hot Dipped
over Matte Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in
this series are backward compatible with Sn/Pb soldering systems.
For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KDC_MEVC.A01 Page 2 of 4
MEV Series
3kVDC Isolated 1W Single Output DC/DC Converters
RIPPLE & NOISE CHARACTERISATION METHOD
All measurement to be taken with the following components connected to the UUT as detailed below.
50 Ohm coax cable, solder connections one end, BNC plug at the other end.
C1
– 1μF X7R multilayer ceramic capacitor rated at minimum 3 x the output voltage of the UUT
C2
– 10μF tantalum capacitor rated at minimum 1.5 x the output voltage of the UUT with ESR of less
C3
– 100nF multilayer ceramic capacitor, general purpose
R1
– 450 Ohm resistor, carbon film, ±1%
than 100 milliohms at 100 kHz e.g. AVX TPS series.
R2
– 50 Ohm BNC termination
T1
– 3T of the coax cable through a ferrite toroid eg Ferroxcube TN32/19/13-3E25
RLOAD – Resistive load at the UUT maximum rating. Connections via twisted wires.
Differential Mode Noise Test Schematic
DC/DC Converter
OSCILLOSCOPE
C1 C2 C3
+
Input
SUPPLY
R1
R2
T1
+
Y INPUT
Output
-
-
R LOAD
EFFICIENCY VS LOAD
MEV 5V Input Voltage
MEV 12V Input Voltage
90
90
80
15V
12V
9V
5V
70
60
Efficiency (%)
Efficiency (%)
80
50
40
30
70
15V
12V
9V
5V
60
50
40
30
20
20
10
10
0
0
10
20
30
40
50
Load (%)
www.murata-ps.com
60
70
80
90
100
0
0
10
20
30
40
50
60
70
80
90
100
Load (%)
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KDC_MEVC.A01 Page 3 of 4
MEV Series
3kVDC Isolated 1W Single Output DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT DETAILS
4 HOLES
0.77 (19.50)
(1.15)
Ø 0.045
0.040 (1.00)
0.236
(6.00)
0.00394 (0.1)
0.1 (2.54)
0.394
(10.00)
MEV1S0505SC
0.0016
(0.40) Min.
XYYWWi
1 2
0.181 (4.60)
0.142 (3.60)
5
7
0.1 (2.54)
0.50 (0.020)
0.1 (2.54)
Unless otherwise stated all dimensions in inches (mm) ±0.5mm.
0.099 (2.52)
0.061 (1.54)
0.0118 (0.30)
0.0079 (0.20)
TUBE OUTLINE DIMENSIONS
0.049 (1.25)
0.6 (15.24)
Weight: 2.3g
1
2
5
7
Function
+VIN
-VIN
-VOUT
+VOUT
PIN CONNECTIONS
Pin
All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54) pitch and within ±0.01 (0.25) of true position.
Unless otherwise stated all dimensions in inches (mm) ±0.5mm.
Tube length : 20.47 (520mm ±2mm).
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
USA:
Mansfield (MA), Tel: (508) 339 3000, email: [email protected]
Canada:
Toronto, Tel: (866) 740 1232, email: [email protected]
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany: München, Tel: +49 (0)89-544334-0, email: [email protected]
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
www.murata-ps.com email: [email protected] ISO 9001 & ISO 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
www.murata-ps.com
Tube Quantity : 25
Singapore: Parkway Centre, Tel: +65 6348 9096, email: [email protected]
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KDC_MEVC.A01 Page 4 of 4