MEF1 Series - power, Murata

MEF1 Series
www.murata-ps.com
Isolated 1W Regulated Single Output DC/DC Converters
Operation to zero load
„
Output regulation <1%
„
„
Power density 0.85W/cm3
„
Single isolated output
UL 94V-0 package material
„
„
Footprint from 1.17cm2
„
1kVDC or 3.5kVDC isolation options
MEF1S0303SP3C
MEF1S0305SP3C
MEF1S0503SP3C
MEF1S0505SP3C
MEF1S1203SP3C
MEF1S1205SP3C
MEF1S2403SP3C
MEF1S2405SP3C
3.3
3.3
5
5
12
12
24
24
3.3
5
3.3
5
3.3
5
3.3
5
Input Current
(Typ.)
Ripple &
Noise (Max.)
%
%
pF
kHrs
63
68
65
69
65
69
64
68
66
71
68.5
73
69
73.5
69
73
40
30
40
50
40
60
35
45
495
867
665
1051
511
1044
580
834
63
68
65
69
65
69
64
68
66
71
68.5
73
69
73.5
69
73
40
30
40
50
40
60
35
45
495
867
665
1051
511
1044
580
834
mA
mVp-p
Efficiency
(Min.)
mA
303
11
35
460
200
9
35
430
303
8
30
290
200
10
40
275
303
11
35
120
200
10
35
115
303
13
40
60
200
13
40
55
3.5kVDC Isolation Part Numbers
303
11
35
460
200
9
35
430
303
8
30
290
200
10
40
275
303
11
35
120
200
10
35
115
303
13
40
60
200
13
40
55
Ripple &
Noise (Typ.)
MTTF1
Short circuit protection
„
3.3
5
3.3
5
3.3
5
3.3
5
Isolation
Capacitance
UL60950 recognised
„
V
3.3
3.3
5
5
12
12
24
24
Efficiency
(Typ.)
FEATURES
V
MEF1S0303SPC
MEF1S0305SPC
MEF1S0503SPC
MEF1S0505SPC
MEF1S1203SPC
MEF1S1205SPC
MEF1S2403SPC
MEF1S2405SPC
Output
Current
Order Code
Nominal
Input
Voltage
Output
Voltage
SELECTION GUIDE
„
3.3V, 5V, 12V & 24V input
INPUT CHARACTERISTICS
„
3.3V & 5V output
Parameter
Conditions
Min.
Typ.
Max.
Voltage range
Continuous operation, 3.3V input types
Continuous operation, 5V input types
Continuous operation, 12V input types
Continuous operation, 24V input types
3.135
4.75
11.4
22.8
3.3
5
12
24
5
3.465
5.25
12.6
25.2
20
mA p-p
Typ.
Max.
Units
0.3
± 2.5
±2
1
0.25
1
„
SMD construction
„
Fully encapsulated with toroidal magnetics
DESCRIPTION
Reflected ripple current
The MEF1 series of DC/DC converters is used
where a tightly regulated supply is required. They
are ideal for situations where the input voltage
is not tightly controlled. The single rail regulated
output makes the ideal choice to power sensors,
such as pressure transducers, hall effect sensors
and mass airflow sensors.
OUTPUT CHARACTERISTICS
Parameter
Voltage set point accuracy
Rated power
Line regulation
Load regulation
Conditions
3.3V Output
5V Output
TA= -40°C to 85°C
High VIN to low VIN
10% load to rated load
Min.
Units
V
%
W
%/%
%
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, MEF1S03 types
Input voltage VIN, MEF1S05 types
Input voltage VIN, MEF1S12 types
Input voltage VIN, MEF1S24 types
Continuous
260°C
450mW
4V
7V
18V
28V
1. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_MEF1.C02 Page 1 of 7
MEF1 Series
Isolated 1W Regulated Single Output DC/DC Converters
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
SPC Versions Flash tested for 1 second
SP3C Versions Flash tested for 1 minute
Viso= 1kVDC
1000
3500
10
Parameter
Conditions
Min.
Switching frequency
0303
5V input types
12V input types & 0305
24V input types
Isolation test voltage
Resistance
Typ.
Max.
Units
VDC
GΩ
GENERAL CHARACTERISTICS
Typ.
Max.
45
50
60
75
Units
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specification
Case temperature above ambient
Storage
Cooling
All output types
-40
-50
Typ.
Max.
Units
85
40
125
°C
Free air convection
TEMPERATURE DERATING GRAPH
RoHS COMPLIANCE INFORMATION
Output Power (W)
1.5
1.0
0.5
0
-40
This series is compatible with RoHS soldering
systems with a peak wave solder temperature of
260ºC for 10 seconds. The pin termination finish
on the SIP package type is Tin Plate, Hot Dipped
over Matte Tin over Nickel Preplate. This series
is backward compatible with Sn/Pb soldering
systems.
85°C
Safe Operating Area
100
50
0
Ambient Temperature (°C)
150
For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_MEF1.C02 Page 2 of 7
MEF1 Series
Isolated 1W Regulated Single Output DC/DC Converters
EFFICIENCY VS LOAD
5V Input
90
80
80
70
70
60
60
Efficiency (%)
Efficiency (%)
3.3V Input
90
50
40
MEF1S0303SPC
30
50
40
MEF1S0503SPC
30
MEF1S0305SPC
20
20
10
10
MEF1S0505SPC
0
0
0
10
20
30
40
50
60
70
80
90
0
100
10
20
30
40
12V Input
60
70
80
90
100
24V Input
90
90
80
80
70
70
60
60
Efficiency (%)
Efficiency (%)
50
Load (%)
Load (%)
50
40
30
40
30
MEF1S1205SPC
20
50
MEF1S2405SPC
20
MEF1S1203SPC
MEF1S2403SPC
10
10
0
0
0
10
20
30
40
50
60
Load (%)
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
Load (%)
www.murata-ps.com/support
KDC_MEF1.C02 Page 3 of 7
MEF1 Series
Isolated 1W Regulated Single Output DC/DC Converters
APPLICATION NOTES
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product
series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF.
Start-up time
μs
310
550
225
460
185
390
160
430
310
550
225
460
185
390
160
430
MEF1S0303SPC
MEF1S0305SPC
MEF1S0503SPC
MEF1S0505SPC
MEF1S1203SPC
MEF1S1205SPC
MEF1S2403SPC
MEF1S2405SPC
MEF1S0303SP3C
MEF1S0305SP3C
MEF1S0503SP3C
MEF1S0505SP3C
MEF1S1203SP3C
MEF1S1205SP3C
MEF1S2403SP3C
MEF1S2405SP3C
MEF1S0305SP3C
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less
C2
than 100mΩ at 100 kHz
C3
100nF multilayer ceramic capacitor, general purpose
R1
450Ω resistor, carbon film, ±1% tolerance
R2
50Ω BNC termination
T1
3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
DC/DC Converter
OSCILLOSCOPE
C1 C2 C3
+
SUPPLY
Input
-
+
R1
T1
R2
Y INPUT
Output
-
R LOAD
www.murata-ps.com/support
KDC_MEF1.C02 Page 4 of 7
MEF1 Series
Isolated 1W Regulated Single Output DC/DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MEF1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second for SPC versions and 3.5kVDC
for 1 minute for SP3C versions.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The MEF1 has been recognized by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system.
The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier
must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according
to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The MEF1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The MEF1 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional insulation, file number E151252 applies. The MEF1 Series of converters are not
internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below.
MEF1S03xxxC: 600mA
MEF1S05xxxC: 400mA
MEF1S12xxxC: 160mA
MEF1S24xxxC: 100mA
All fuses should be UL approved and rated to at least the maximum allowable DC input voltage.
www.murata-ps.com/support
KDC_MEF1.C02 Page 5 of 7
MEF1 Series
Isolated 1W Regulated Single Output DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS - SPC
SPC
SP3C
19.65 [0.774] MAX
19.65 [0.774] MAX
6.15 [0.242] MAX
10.15 [0.400] MAX
4.10±0.50 [0.161±0.020]
1
2
4
6
2.54 [0.100]
0.40 [0.016] MIN
0.40 [0.016] MIN
6.15 [0.242] MAX
10.15 [0.400] MAX
4.10±0.50 [0.161±0.020]
0.50 [0.020]
1
2
5
7
2.54 [0.100]
0.50 [0.020]
Pin
Function
1
2
4
6
+VIN
-Vin
-VOUT
+VOUT
PIN CONNECTIONS - SP3C
Pin
Function
1
2
5
7
+VIN
-VIN
-VOUT
+VOUT
5.08 [0.200]
5.08 [0.200]
1.45
1.00
2.52
1.54
[ ]
[ ]
0.057
0.039
12.70 [0.500]
0.099
0.061
1.45
1.00
[ ]
2.52
1.54
0.057
0.039
0.25 [0.010]
15.24 [0.600]
[ ]
0.099
0.061
Weight: 1.6g
All dimensions in mm (mm ±0.25mm) inches ±0.01. All pins on a 2.54 (0.1) pitch and within ±0.25 (0.1) of true position.
www.murata-ps.com/support
KDC_MEF1.C02 Page 6 of 7
MEF1 Series
Isolated 1W Regulated Single Output DC/DC Converters
PACKAGE SPECIFICATIONS (continued)
RECOMMENDED FOOTPRINT DETAILS
SPC
SP3C
1.15 (0.045)
Ø 1.00 (0.039)
1.15 (0.045)
Ø 1.00 (0.039)
4 HOLES
4 HOLES
0.1 (0.004)
0.1 (0.004)
2.54 (0.1)
2.54 (0.1)
2.54 (0.1)
2.54 (0.1)
All dimensions in mm ±0.25mm (inches ±0.01).
TUBE OUTLINE DIMENSIONS
7 Pin SIP Tube
5.00 (0.2)
9.30 (0.366)
18.00 (0.709)
12.43 (0.489)
0.50 (0.020)
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
All dimensions in mm ±0.25mm (inches ±0.01).
Tube length (7 Pin SIP) : 20.47 (520mm ±2mm).
Tube Quantity : 25
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2014 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_MEF1.C02 Page 7 of 7