ETC 12D12.250A

6 Watt Dual Series DC/DC Converters
Features
Description
!
Low Profile Copper Case (0.375" High)
!
Six-Sided Shielded Case
Ideal for industrial applications, these 6 Watt Dual Output
converters are suitable for use in telecommunications, medical
and other systems that require floating outputs.
!
Low Input/Output Noise Operation
!
700 VDC Input/Output Isolation
!
Short Circuit Protected Output
!
Fixed Frequency Operation Independent
of Line and Load
!
Highly Regulated/Low Drift Output
!
Rugged High Speed MOSFET Power Chopper
!
5 Year Warranty
These DC/DC converters operate at a fixed frequency that
is independent of line and load. The isolation transformer
provides 700 VDC isolation between input and output grounds
allowing the outputs to be floated above or below the input
ground. Designed for maximum performance, each unit has
an LC input filter, high speed MOSFET power chopper and
short circuit protected linear post regulators.
The copper case, measuring only 0.375" high, is shielded
on all six sides to minimize radiated noise. All converters in
this series are guaranteed under the CALEX 5 Year Warranty.
Selection Chart
Model
Input Range
VDC
MIN
MAX
Outputs
VDC
Outputs
mA
12D12.250A
11.16
13.20
±12
±250
12D15.200A
11.16
13.20
±15
±200
±250
24D12.250A
22.32
26.40
±12
24D15.200A
22.32
26.40
±15
±200
28D12.250A
26.04
30.80
±12
±250
28D15.200A
26.04
30.80
±15
±200
48D12.250A
44.64
52.80
±12
±250
48D15.200A
44.64
52.80
±15
±200
6 Watt Dual Output Series Block Diagram
SERIES
PASS
REGULATOR
3
+ OUTPUT
4
CMN
A
- INPUT 2
LC
INPUT
FILTER
FIXED
FREQUENCY
POWER
DRIVER
SERIES
PASS
REGULATOR
CASE
5
- OUTPUT
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: [email protected]
1
1.29.98
+ INPUT 1
6 Watt Dual Series DC/DC Converters
Input Parameters*
Model
12D12.250A
Voltage Range
Reflected Ripple, 0-20MHz bw
Input Current Full Load
No Load
Efficiency
Switching Frequency
Maximum Input Overvoltage, 100ms
No damage
Turn-on Time, 1% Output Error (2)
MIN
MAX
TYP
MAX
TYP
TYP
TYP
12D15.200A
780
45
64
769
50
65
TYP
Switching Frequency
Maximum Input Overvoltage, 100ms
No damage
Turn-on Time, 1% Output Error (2)
362
23
69
mA
%
kHz
30
VDC
3
ms
(3)
28D12.250A
Reflected Ripple, 0-20MHz bw
mA P-P
378
22
66
15
TYP
Units
VDC
75
MAX
Model
Input Current Full Load
No Load
Efficiency
24D15.200A
22.32
26.40
5
15
Recommended Fuse
Voltage Range
24D12.250A
11.16
13.20
10
25
MIN
MAX
TYP
MAX
TYP
TYP
TYP
28D15.200A
48D12.250A
26.04
30.80
7
15
325
22
66
48D15.200A
44.64
52.80
15
25
315
22
68
TYP
198
21
63
VDC
mA P-P
189
21
66
75
MAX
60
TYP
mA
%
kHz
35
3
Recommended Fuse
Units
VDC
ms
(3)
Output Parameters*
Output Voltage
12D15.200A 24D15.200A
28D15.200A 48D15.200A
±15
0
±200
14.90
15.00
15.10
0.6
1.0
Line Regulation
Vin = Min-Max VDC
Transient Response (6)
MIN
MAX
MIN
TYP
MAX
TYP
MAX
TYP
MAX
TYP
MAX
TYP
Dynamic Response (7)
TYP
10
Input Ripple Rejection (8)
TYP
TYP
MAX
TYP
MAX
65
10
40
Rated Current (4)
Voltage Range
100% Load
Output Balance
(Plus to Minus Output, Full Load)
Load Regulation 0-100%
Noise, 0-20MHz bw
Temperature Coefficient
0.02
0.10
0.05
0.10
never exceeds 1%
100
250
VDC
mA
VDC
%
%
%
A
µs
mV peak
dB
mV P-P
150
300
Short Circuit Protection to
Common for all Outputs
Units
ppm/°C
Continuous, 8 Hours Minimum Current Limit
NOTES
parameters measured at Tc=25°C, nominal input voltage
* All
and full rated load unless otherwise noted. Refer to the
CALEX Application Notes for the definition of terms,
measurement circuits and other information.
(2) Turn on time is defined as the time from the application of power
until the output is within 1% of its final value.
(3)
(4)
(5)
Determine the correct fuse size by calculating the maximum DC
current drain at low line input, maximum load and then adding 20
to 25 percent.
No minimum load required.
Short term stability is specified after a 30 minute warm-up at full
load and with constant line, load and ambient conditions.
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: [email protected]
2
1.29.98
Model
12D12.250A 24D12.250A
28D12.250A 48D12.250A
±12
0
±250
11.90
12.00
12.10
0.6
1.0
6 Watt Dual Series DC/DC Converters
General Specifications*
All Models
Isolation
Isolation Voltage
10µA Leakage
Input-Output
Input to Output
Capacitance
Environmental
Case Operating Range
No Derating
Storage Range
Thermal Impedance (9)
Units
MIN
700
VDC
TYP
75
pF
MIN
MAX
MIN
MAX
TYP
-40
85
-55
100
10
°C/Watt
1.7
oz
°C
°C
General
Unit Weight
Mounting Kits
TYP
BOTTOM VIEW
MS6 & MS15
SIDE VIEW
Mechanical tolerances unless otherwise noted:
X.XX dimensions: ±0.020 inches
(7)
(8)
(9)
X.XXX dimensions: ±0.005 inches
The transient response is specified as the time required for the
output to settle from a 100% step load change (Rise time of step
= 2 µSec.) to a 1% error band.
Dynamic response is the peak overshoot voltage during the
transient response time as defined in note 6 above.
The input ripple rejection is specified for DC to 120Hz ripple with
a modulation amplitude of 1% Vin.
The case thermal impedance is specified as the case temperature
rise over ambient per package watt dissipated.
Seal around terminals is not hermetic. Do not immerse units in any
liquid.
Pin
1
2
3
4
5
Function
+INPUT
-INPUT
+OUTPUT
CMN
-OUTPUT
A
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: [email protected]
3
1.29.98
(6)