EPCOS N87

Ferrites and accessories
SIFERRIT material N87
Date:
September 2006
Data Sheet
© EPCOS AG 2006. Reproduction, publication and dissemination of this publication, enclosures
hereto and the information contained therein without EPCOS’ prior express consent is prohibited.
SIFERRIT materials
N87
Material properties
Preferred application
Power transformers
Material
N87
Base material
MnZn
Symbol
Initial permeability
(T = 25 °C)
Unit
μi
2200
±25%
Flux density
BS (25 °C) mT
(H = 1200 A/m, f = 10 kHz) BS (100 °C) mT
Coercive field strength
(f = 10 kHz)
Hc (25 °C) A/m
Hc (100 °C)
Optimum frequency range
21
13
kHz
Hysteresis
material constant
ηB
Curie temperature
TC
Mean value of αF
at 25 … 55 °C
Density (typical values)
Relative core losses
(typical values)
490
390
25 …
500
10–6/mT <1.0
°C
>210
10–6/K
4
kg/m3
4850
PV
25 kHz, 200 mT, 100 °C
kW/m3
57
100 kHz, 200 mT, 100 °C
kW/m3
375
300 kHz, 100 mT, 100 °C
kW/m3
390
500 kHz, 50 mT, 100 °C
kW/m3
215
Ωm
10
Resistivity
ρ
Core shapes
Please read Cautions and warnings and
Important notes at the end of this document.
RM, P, PM, ETD, EFD, E,
ER, EP, EQ, ELP, U, Toroid
2
09/06
SIFERRIT materials
N87
Initial permeability μi
versus temperature
(measured on R34 toroids, B ≤0.25 mT)
Complex permeability
versus frequency
(measured on R34 toroids, B ≤0.25 mT)
FAL0596-E
10 4
µ s’
µi
µ s’ ; µ s’’
10
3
10
2
FAL0597-M
5000
3000
2000
µ s’’
10 1
1000
10 0 _ 2
10
10
_1
10 0
0
_ 60 _ 20
10 1 MHz 10 2
f
Amplitude permeability
versus AC field flux density
(measured on R34 toroids, B ≤0.25 mT)
FAL0598-V
6000
µa
4000
3000
2000
f < 10 kHz
25 ˚C
100 ˚C
1000
0
0
100
200
300
400 mT 500
B
Please read Cautions and warnings and
Important notes at the end of this document.
3
09/06
20
60 100 140 180
˚C 260
T
SIFERRIT materials
N87
Dynamic magnetization curves
(typical values)
(f = 10 kHz, T = 25 °C)
Dynamic magnetization curves
(typical values)
(f = 10 kHz, T = 100 °C)
FAL0599-4
500
FAL0600-B
500
mT
mT
B 400
B
300
300
200
200
100
100
0
-200 0
0
-200 0
200 400 600 800 1000 A/m 1400
H
DC magnetic bias
of P, RM, PM and E cores
(B ≤0.25 mT, f = 10 kHz, T = 25 °C)
DC magnetic bias
of P, RM, PM and E cores
(B ≤0.25 mT, f = 10 kHz, T = 100 °C)
FAL0601-J
10 4
FAL0602-S
10 4
5
µ rev
200 400 600 800 1000 A/m 1400
H
5
µ rev
µ e = 1000
500
500
5
µ e = 1000
5
200
200
100
10 2
50
5
10 1
5
5
10 0
10 1
50
5
10 1
10 0 _
10 1
100
10 2
10 2
10 0 _
10 1
A/m 10 4
HDC
Please read Cautions and warnings and
Important notes at the end of this document.
4
09/06
10 0
10 1
10 2
A/m 10 4
HDC
SIFERRIT materials
N87
Relative core losses
versus AC field flux density
(measured on R34 toroids)
Relative core losses
versus temperature
(measured on R34 toroids)
FAL0603-1
10 3
kW
m3
FAL0604-9
10 4
f = 100 kHz
kW/m 3
PV
PV
10 3
10
2
5
200 mT
10 2
100 mT
5
10 1
50 mT
10 1
f = 100 kHz
25 ˚C
100 ˚C
10 0
10 1
10 2
5
10 0
20
10 3
mT
B
Relative core losses
versus frequency
(measured on R34 toroids)
FAL0605-H
10 4
kW
m3
PV
10
200 mT
3
100 mT
10 2
50 mT
25 mT
10 1
10 0
10
25 ˚C
100 ˚C
_1
10 1
5
10 2
10 3
kHz
f
Please read Cautions and warnings and
Important notes at the end of this document.
5
09/06
25 mT
40
60
80
100 ˚C 120
T
SIFERRIT materials
Cautions and warnings
General
Based on IEC 60401-3, the data specified here are typical data for the material in question, which
have been determined principally on the basis of toroids (ring cores).
The purpose of such characteristic material data is to provide the user with improved means for
comparing different materials.
There is no direct relationship between characteristic material data and the data measured using
other core shapes and/or core sizes made of the same material. In the absence of further agreements with the manufacturer, only those specifications given for the core shape and/or core size in
question are binding.
Effects of core combination on AL value
Stresses in the core affect not only the mechanical but also the magnetic properties. It is apparent
that the initial permeability is dependent on the stress state of the core. The higher the stresses are
in the core, the lower is the value for the initial permeability. Thus the embedding medium should
have the greatest possible elasticity.
For detailed information see Data Book 2007, chapter “General – Definitions, 8.2”.
Heating up
Ferrites can run hot during operation at higher flux densities and higher frequencies.
6
09/06
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with
them than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or failure
before the end of their usual service life cannot be completely ruled out in the current state
of the art, even if they are operated as specified. In customer applications requiring a very
high level of operational safety and especially in customer applications in which the malfunction
or failure of an electronic component could endanger human life or health (e.g. in accident
prevention or life-saving systems), it must therefore be ensured by means of suitable design of
the customer application or other action taken by the customer (e.g. installation of protective
circuitry or redundancy) that no injury or damage is sustained by third parties in the event of
malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products.
Consequently, we cannot guarantee that all products named in this publication will always be
available.
The aforementioned does not apply in the case of individual agreements deviating from the
foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version
of the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP, MiniBlue,
MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, SIFERRIT, SIFI, SIKOREL,
SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
7
04/09