Présente / Presents: DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com NG6D NHG RELAYS NG6D Operation condition R C US E158859 Patent NO.: 200420081938.2 17.5 6.5 12.5 Features Small size,light weight. PC board mounting Low coil power consumption 0.2W. Suitable for household electrical appliances, automation system, electronic equipment, instrument, meter, telecommunication facilities and remote control facilities. Insulation Resistance 1000M Dielectric Strength Between contacts Between contact and coil 50Hz 750V 50Hz 3000V surge voltage:6kV Item 6 of IEC255-5 Item 6 and 8 of IEC255-5 Functional:100m/s 2 11ms Survival:1000m/s2 6ms IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass min (at 500VDC) Item 7 of IEC255-5 10~50Hz Functional & Survival double amplitude 1.5mm 5N 235 2 3 0.5s -25~70 20% ~85% (at40 ) 3g IEC68-2-3Test Ca Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. Safety approvals Ordering Information Safety approval Load NG6D A DC12V 2 3 3 Coil rated voltage (V) DC:5,12,24 1 Part number NG6D 2 Contact arrangement A:1A Dimensions 0.5 0.020 1A (SPSTNO) Contact Material Silver Alloy Contact Rating (resistive) 5A/30VDC,250VAC Max. Switching Power 150W Max. Switching Voltage 30VDC 250VAC Contact Resistance or Voltage drop Electrical Mechanical 1250VA 100m 2 min Switching load:10mA/5V Max. Switching Current:5A Item 3.12 of IEC255-7 10 5 2-0.5 0.020 Item 3.30 of IEC255-7 10 7 6.5max. 0.244max. 3.5 Contact Arrangement 17.5max. 0.689max. 12.5max. 0.492max. Contact Data Operational life mm /inch Item 3.31 of IEC255-7 2.54 0.1 CAUTION: 1.13 0.044 5.08 2-0.8 0.031 4-0.3 0.012 0.200 7.62 0.138 1 UL & CUR 5A/250VAC,30VDC 5.08 0.200 0.300 Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not recommended for subsequent use in low level applications. Dimensions Coil Parameter 005-200 012-200 024-200 Rated voltage VDC Rated Max. 5 12 24 6.5 15.6 31.2 Coil resistance 10% 125 720 2880 Pickup voltage V (max) 70%of rated Volt 3.5 8.4 16.8 Release voltage VDC (min) 10%of rated Volt 0.5 1.2 2.4 Coil power consumption W 0.2 Operate Time ms Release Time ms 10 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.54 0.1 2.54 0.1 Dash numbers 4- 1.3 0.043 5 Wiring diagram (Bottom view) Mounting (Bottom view) 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. Ningbo Huauan Relay Corporation LTD.